1 Jul 2015
Ganesan S Karampalis C Garrido E Tsirikos AI

Acute angulation at the thoracolumbar junction with segmental subluxation of the spine occurring at the level above an anteriorly hypoplastic vertebra in otherwise normal children is a rare condition described as infantile developmental thoracolumbar kyphosis. Three patient series with total of 18 children have been reported in the literature. We report five children who presented with thoracolumbar kyphosis and discuss the treatment algorithm. We reviewed the medical records and spinal imaging at initial clinical presentation and at minimum two-year follow-up. The mean age at presentation was eight months (two to 12). All five children had L2 anterior vertebral body hypoplasia. The kyphosis improved spontaneously in three children kept under monitoring. In contrast, the deformity was progressive in two patients who were treated with bracing. The kyphosis and segmental subluxation corrected at latest follow-up (mean age 52 months; 48 to 60) in all patients with near complete reconstitution of the anomalous vertebra. The deformity and radiological imaging on a young child can cause anxiety to both parents and treating physicians. Diagnostic workup and treatment algorithm in the management of infantile developmental thoracolumbar kyphosis is proposed. Observation is indicated for non-progressive kyphosis and bracing if there is evidence of kyphosis and segmental subluxation deterioration beyond walking age. Surgical stabilisation of the spine can be reserved for severe progressive deformities unresponsive to conservative treatment.

Cite this article: Bone Joint J 2015;97-B:982–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1546 - 1550
1 Nov 2012
Longo UG Loppini M Romeo G Maffulli N Denaro V

Wrong-level surgery is a unique pitfall in spinal surgery and is part of the wider field of wrong-site surgery. Wrong-site surgery affects both patients and surgeons and has received much media attention. We performed this systematic review to determine the incidence and prevalence of wrong-level procedures in spinal surgery and to identify effective prevention strategies. We retrieved 12 studies reporting the incidence or prevalence of wrong-site surgery and that provided information about prevention strategies. Of these, ten studies were performed on patients undergoing lumbar spine surgery and two on patients undergoing lumbar, thoracic or cervical spine procedures. A higher frequency of wrong-level surgery in lumbar procedures than in cervical procedures was found. Only one study assessed preventative strategies for wrong-site surgery, demonstrating that current site-verification protocols did not prevent about one-third of the cases. The current literature does not provide a definitive estimate of the occurrence of wrong-site spinal surgery, and there is no published evidence to support the effectiveness of site-verification protocols. Further prevention strategies need to be developed to reduce the risk of wrong-site surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1393 - 1398
1 Oct 2012
Mattila M Jalanko T Puisto V Pajulo O Helenius IJ

We compared the clinical, radiological and quality-of-life outcomes between hybrid and total pedicle screw instrumentation in patients undergoing surgery for neuromuscular scoliosis. A matched comparison using prospectively collected data was undertaken. A total of 66 patients underwent posterior or anteroposterior correction and fusion with hybrid (n = 33, mean age at surgery 15.8 years (9.10 to 19.6)) or total pedicle screw instrumentation (n = 33, mean age 14.7 years (7.0 to 20.7)) with a minimum follow-up of two years. The major curve pre-operatively was a mean of 87° (sd 29, 25° to 141°) and 81° (sd 18, 47° to 116°) in the hybrid and total pedicle screw groups, respectively (p = 0.29) and at a minimum of two years it was 33° (sd 20; 2° to 87°) and 20° (sd 12; 1° to 55°), respectively (p = 0.0016). The mean correction of the major curve was 59% (41% to 88%) in the hybrid and 75% (43% to 99%) in the total pedicle screw groups at two-year follow-up (p = 0.0011). The mean operating time was 7.45 hours (sd 2.18) and 6.04 hours (sd 1.71) in the hybrid and total pedicle screw groups, respectively (p = 0.001), and the mean intra-operative blood loss was 3760 ml (sd 2790) and 1785 ml (sd 1110), respectively (p = 0.001).