Aims. The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral locked plate and a six-pin monorail
fixator on its anteromedial surface. A corticotomy was performed
at the appropriate level. During the third stage, i.e. at the end
of the distraction phase, the transported fragment was aligned and
fixed to the plate with two to four screws. An iliac crest autograft
was added to the docking site and the fixator was removed. Functional
outcome was assessed using the Association for the Study and Application
of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes
were assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. The mean age of patients was 38.1 years (. sd. 12.7). There
were 13 men and one woman. The mean size of the defect was 6.4 cm
(. sd. 1.3). the mean follow-up was 33.2 months (24 to 50).
The mean external fixator index was 21.2 days/cm (. sd. 1.5).
The complication rate was 0.5 (7/14) per patient. According to the
classification of Paley, there were five problems and two obstacles
but no true complications. The ASAMI bone score was excellent in
all patients. The functional ASAMI scores were excellent in eight
and good in six patients. The mean MSTS composite score was 83.9%
(. sd. 7.1), with an