Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims

Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques.

Methods

In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test.