Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 478 - 484
1 Apr 2020
Daniels AM Wyers CE Janzing HMJ Sassen S Loeffen D Kaarsemaker S van Rietbergen B Hannemann PFW Poeze M van den Bergh JP

Aims. Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Methods. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture. Results. A total of nine (29%) scaphoid fractures and 12 (39%) other fractures were diagnosed in 20 patients (65%) using HR-pQCT across the four observers. The interobserver agreement was 91% for the identification of a scaphoid fracture (95% confidence interval (CI) 0.76 to 1.00) and 80% for other fractures (95% CI 0.72 to 0.87). The mean ICC for the classification of a scaphoid fracture in the seven patients diagnosed with scaphoid fracture by all four observers was 73% (95% CI 0.42 to 0.94). Conclusion. We conclude that the diagnosis of scaphoid and other fractures is reliable when using HR-pQCT in patients with a clinically-suspected fracture. Cite this article: Bone Joint J 2020;102-B(4):478–484


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims. The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function. Methods. We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis. Results. According to Eaton-Glickel classification, 11, 17, 17, and eight hands were stage 0 to I, II, III, and IV, respectively. The interobserver reliability for determining the stage of arthritis was moderate for radiographs (k = 0.41) and substantial for CT scans (k = 0.67). In a binary categorical analysis using SUVmax, pain (p < 0.001) and PRWHE scores (p = 0.004) were significantly higher in hands with higher SUVmax. Using multivariate linear regression to estimate the pain VAS, only SUVmax (B 0.172 (95% confidence interval (CI) 0.065 to 0.279; p = 0.002) showed a significant association. Estimating the variation of PRWHE scores using the same model, only SUVmax (B 1.378 (95% CI, 0.082 to 2.674); p = 0.038) showed a significant association. Conclusion. The CT scans of SPECT/CT provided better interobserver reliability than routine radiographs for evaluating the severity of arthritis. A higher SUVmax in SPECT/CT was associated with more pain and functional disabilities of basal joint arthritis of the thumb. This approach could be used to complement radiographs for the evaluation of patients with this condition. Cite this article: Bone Joint J 2021;103-B(8):1380–1385


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1386 - 1391
2 Aug 2021
Xiao J Liu B Li L Shi H Wu F

Aims

The primary aim of this study was to assess if traumatic triangular fibrocartilage complex (TFCC) tears can be treated successfully with immobilization alone. Our secondary aims were to identify clinical factors that may predict a poor prognosis.

Methods

This was a retrospective analysis of 89 wrists in 88 patients between January 2015 and January 2019. All patients were managed conservatively initially with either a short-arm or above-elbow custom-moulded thermoplastic splint for six weeks. Outcome measures recorded included a visual analogue scale for pain, Patient-Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand score, and the modified Mayo Wrist Score (MMWS). Patients were considered to have had a poor outcome if their final MMWS was less than 80 points, or if they required eventual surgical intervention. Univariate and logistic regression analyses were used to identify independent predictors for a poor outcome.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1200 - 1209
14 Sep 2020
Miyamura S Lans J He JJ Murase T Jupiter JB Chen NC

Aims

We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations.

Methods

We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 704 - 710
1 Apr 2021
van den Berge BA Werker PMN Broekstra DC

Aims

With novel promising therapies potentially limiting progression of Dupuytren’s disease (DD), better patient stratification is needed. We aimed to quantify DD development and progression after seven years in a population-based cohort, and to identify factors predictive of disease development or progression.

Methods

All surviving participants from our previous prevalence study were invited to participate in the current prospective cohort study. Participants were examined for presence of DD and Iselin’s classification was applied. They were asked to complete comprehensive questionnaires. Disease progression was defined as advancement to a further Iselin stage or surgery. Potential predictive factors were assessed using multivariable regression analyses. Of 763 participants in our original study, 398 were available for further investigation seven years later.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims

The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius.

Methods

We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims

The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.

Methods

A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims

Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion.

Methods

Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 229 - 234
1 Feb 2015
Choi W Lee HJ Kim D Lee C Lee BG Kim J Lee K

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (sd 0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (sd 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (sd 12.2) in group 1 and 10.5 (sd 13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (sd 14.04) in group 1 and 82.6 (sd 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson’s correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient –0.26, p = 0.02).

We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome.

Cite this article: Bone Joint J 2015;97-B:229–34.