Keel MJB Ecker TM Cullmann JL Bergmann M Bonel HM Büchler L Siebenrock KA Bastian JD

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five ‘windows’ for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called ‘Pararectus’ approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (. sd. 2.6) vs 0.1 mm (. sd. 0.3), p < 0.001; and mean gap 11.5 mm (. sd. 6.5) vs 0.8 mm (. sd. 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims

This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days.

Methods

We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 83 - 91
1 Jan 2019
Whitehouse MR Berstock JR Kelly MB Gregson CL Judge A Sayers A Chesser TJ

Aims

The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality.

Patients and Methods

Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 693 - 702
1 Jun 2018
Jayakumar P Overbeek CL Vranceanu A Williams M Lamb S Ring D Gwilym S

Aims

Outcome measures quantifying aspects of health in a precise, efficient, and user-friendly manner are in demand. Computer adaptive tests (CATs) may overcome the limitations of established fixed scales and be more adept at measuring outcomes in trauma. The primary objective of this review was to gain a comprehensive understanding of the psychometric properties of CATs compared with fixed-length scales in the assessment of outcome in patients who have suffered trauma of the upper limb. Study designs, outcome measures and methodological quality are defined, along with trends in investigation.

Materials and Methods

A search of multiple electronic databases was undertaken on 1 January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”, and “anatomical regions”. Studies involving adults suffering trauma to the upper limb, and undergoing any intervention, were eligible. Those involving the measurement of outcome with any CATs were included. Identification, screening, and eligibility were undertaken, followed by the extraction of data and quality assessment using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) criteria. The review is reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg

istered (PROSPERO: CRD42016053886).


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1125 - 1131
1 Sep 2017
Rickman M Varghese VD

In the time since Letournel popularised the surgical treatment of acetabular fractures, more than 25 years ago, there have been many changes within the field, related to patients, surgical technique, implants and post-operative care. However, the long-term outcomes appear largely unchanged. Does this represent stasis or have the advances been mitigated by other negative factors? In this article we have attempted to document the recent changes within the surgery of patients with a fracture involving the acetabulum, outline contemporary management, and identify the major problem areas where further research is most needed.

Cite this article: Bone Joint J 2017;99-B:1125–31


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims

We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy.

Materials and Methods

Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).

Cite this article: Bone Joint J 2013;95-B:1406–9.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (sd 33 900) vs 12 800 cycles (sd 6100); p = 0.007) and mean axial stiffness (220 N/mm (sd 80) vs 70 N/mm (sd 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (sd 0.9) vs 5.1 Nm/° (sd 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (sd 25 600) vs 52 400 cycles (sd 22 500); p = 0.04).

The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients.

Cite this article: Bone Joint J 2014;96-B:114–21.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating.

This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK.

Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen.

There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively.

This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.

Cite this article: Bone Joint J 2015;97-B:94–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 391 - 397
1 Mar 2012
Parker MJ Bowers TR Pryor GA

In a randomised trial involving 598 patients with 600 trochanteric fractures of the hip, the fractures were treated with either a sliding hip screw (n = 300) or a Targon PF intramedullary nail (n = 300). The mean age of the patients was 82 years (26 to 104). All surviving patients were reviewed at one year with functional outcome assessed by a research nurse blinded to the treatment used. The intramedullary nail was found to have a slightly increased mean operative time (46 minutes (sd 12.3) versus 49 minutes (sd 12.7), p < 0.001) and an increased mean radiological screening time (0.3 minutes (sd 0.2) versus 0.5 minutes (sd 0.3), p <  0.001). Operative difficulties were more common with the intramedullary nail. There was no statistically significant difference between implants for wound healing complications (p = 1), or need for post-operative blood transfusion (p = 1), and medical complications were similarly distributed in both groups. There was a tendency to fewer revisions of fixation or conversion to an arthroplasty in the nail group, although the difference was not statistically significant (nine versus three cases, p = 0.14). The extent of shortening, loss of hip flexion, mortality and degree of residual pain were similar in both groups. The recovery of mobility was superior for those treated with the intramedullary nails (p = 0.01 at one year from injury).

In summary, both implants produced comparable results but there was a tendency to better return of mobility for those treated with the intramedullary nail.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm3) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations.

In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans.

Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°.

The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 246 - 249
1 Feb 2010
Jain AK Dhammi IK Singh AP Mishra P

The optimal method for the management of neglected traumatic bifacetal dislocation of the subaxial cervical spine has not been established. We treated four patients in whom the mean delay between injury and presentation was four months (1 to 5). There were two dislocations at the C5-6 level and one each at C4-5 and C3-4. The mean age of the patients was 48.2 years (27 to 60). Each patient presented with neck pain and restricted movement of the cervical spine. Three of the four had a myelopathy.

We carried out a two-stage procedure under the same anaesthetic. First, a posterior soft-tissue release and partial facetectomy were undertaken. This allowed partial reduction of the dislocation which was then supplemented by interspinous wiring and corticocancellous graft. Next, through an anterior approach, discectomy, tricortical bone grafting and anterior cervical plating were carried out.

All the patients achieved a nearly anatomical reduction and sagittal alignment. The mean follow-up was 2.6 years (1 to 4). The myelopathy settled completely in the three patients who had a pre-operative neurological deficit. There was no graft dislodgement or graft-related problems. Bony fusion occurred in all patients and a satisfactory reduction was maintained.

The posteroanterior procedure for neglected traumatic bifacetal dislocation of the subaxial cervical spine is a good method of achieving sagittal alignment with less risk of iatrogenic neurological injury, a reduced operating time, decreased blood loss, and a shorter hospital stay compared with other procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1201 - 1207
1 Sep 2009
Lefaivre KA Starr AJ Barker BP Overturf S Reinert CM

We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta.

There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (sd 6.5). All but one patient had iliosacral screws implanted, 18 had screws in the anterior column, six had plates at the symphysis pubis and 12 had anterior external fixators. The mean maximum horizontal or vertical displacement was improved from 30.8 mm (sd 2.7) to a mean of 7.1 mm (sd 0.7). The reduction was assessed as excellent in ten patients, good in 18, and fair in the remainder. There was no significant influence on the quality of the reduction caused by obesity (p = 0.34), the type of fracture (p = 0.41) or delay to surgery (p = 0.83).

The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 91 - 96
1 Jan 2009
Labbe J Peres O Leclair O Goulon R Scemama P Jourdel F

We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1391 - 1396
1 Oct 2005
Griffin DB Beaulé PE Matta JM

There remains uncertainty about the most effective surgical approach in the treatment of complex fractures of the acetabulum. We have reviewed the experience of a single surgeon using the extended iliofemoral approach, as described by Letournel.

A review of the database of such fractures identified 106 patients operated on using this approach with a minimum follow-up of two years. All data were collected prospectively. The fractures involved both columns in 64 (60%). Operation was undertaken in less than 21 days after injury in 71 patients (67%) and in 35 (33%) the procedure was carried out later than this. The reduction of the fracture was measured on plain radiographs taken after operation and defined as anatomical (0 to 1 mm of displacement); imperfect (2 to 3 mm) or poor (> 3 mm). The functional outcome was measured by the modified Merle d’Aubigné and Postel score. The mean follow-up was for 6.3 years (2 to 17).

All patients achieved union of the fractures. The reduction was graded as anatomical in 76 (72%) of the patients, imperfect in 23 (22%), and poor in six (6%). The mean Merle d’Aubigné and Postel score was 15 (5 to 18) with 68 patients (64%) showing good or excellent and 38 (36%) fair or poor results. Function correlated significantly with the accuracy of the reduction (p < 0.009). Significant heterotopic ossification developed in 32 patients (30%) and was associated with a worse mean Merle d’Aubigné and Postel score of 13.7.

The extended iliofemoral approach can be performed safely in selected complex acetabular fractures with an acceptable clinical outcome and rate of complications. Effective prophylaxis against heterotopic ossification should be strongly considered.