Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 478 - 484
1 Apr 2020
Daniels AM Wyers CE Janzing HMJ Sassen S Loeffen D Kaarsemaker S van Rietbergen B Hannemann PFW Poeze M van den Bergh JP

Aims. Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Methods. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture. Results. A total of nine (29%) scaphoid fractures and 12 (39%) other fractures were diagnosed in 20 patients (65%) using HR-pQCT across the four observers. The interobserver agreement was 91% for the identification of a scaphoid fracture (95% confidence interval (CI) 0.76 to 1.00) and 80% for other fractures (95% CI 0.72 to 0.87). The mean ICC for the classification of a scaphoid fracture in the seven patients diagnosed with scaphoid fracture by all four observers was 73% (95% CI 0.42 to 0.94). Conclusion. We conclude that the diagnosis of scaphoid and other fractures is reliable when using HR-pQCT in patients with a clinically-suspected fracture. Cite this article: Bone Joint J 2020;102-B(4):478–484


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 262 - 267
1 Mar 2024
de Villeneuve Bargemon J Mari R Mathoulin C Prenaud C Merlini L

Aims

Patients with midcarpal instability are difficult to manage. It is a rare condition, and few studies have reported the outcomes of surgical treatment. No prospective or retrospective study has reported the results of arthroscopic palmar capsuloligamentous suturing. Our aim was to report the results of a prospective study of arthroscopic suture of this ligament complex in patients with midcarpal instability.

Methods

This prospective single-centre study was undertaken between March 2012 and May 2022. The primary outcome was to evaluate the functional outcomes of arthroscopic palmar midcarpal suture. The study included 12 patients, eight male and four female, with a mean age of 27.5 years (19 to 42). They were reviewed at three months, six months, and one year postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 657 - 662
1 Jun 2023
Meaike JJ Meaike JD Collins MS Bishop AT Shin AY

Aims

The benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid.

Methods

A retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 711 - 717
1 Apr 2021
Feitz R van der Oest MJW van der Heijden EPA Slijper HP Selles RW Hovius SER

Aims

Patients with a triangular fibrocartilage complex (TFCC) injury report ulnar-sided wrist pain and impaired function. The surgical procedure of TFCC reinsertion aims to improve function in patients with this injury in whom conservative treatment has failed. The purpose of this study was to investigate the outcomes of open TFCC reinsertion.

Methods

The study involved 274 patients who underwent open repair of the TFCC between December 2013 and December 2018. The patients completed the Patient-Rated Wrist Evaluation (PRWE) questionnaire, and scored pain and function using a visual analogue scale (VAS). Range of motion (ROM) was assessed by experienced hand therapists.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims

The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.

Methods

A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 137 - 143
1 Jan 2020
Dias R Johnson NA Dias JJ

Aims

Carpal malalignment after a distal radial fracture occurs due to loss of volar tilt. Several studies have shown that this has an adverse influence on function. We aimed to investigate the magnitude of dorsal tilt that leads to carpal malalignment, whether reduction of dorsal tilt will correct carpal malalignment, and which measure of carpal malalignment is the most useful.

Methods

Radiographs of patients with a distal radial fracture were prospectively collected and reviewed. Measurements of carpal malalignment were recorded on the initial radiograph, the radiograph following reduction of the fracture, and after a further interval. Linear regression modelling was used to assess the relationship between dorsal tilt and carpal malalignment. Receiver operating characteristic (ROC) analysis was used to identify which values of dorsal tilt led to carpal malalignment.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 818 - 823
1 Jun 2015
Plant CE Hickson C Hedley H Parsons NR Costa ML

We conducted an observational radiographic study to determine the inter- and intra-observer reliability of the AO classification of fractures of the distal radius. Plain posteroanterior and lateral radiographs of 456 patients with an acute fracture of the distal radius were classified by a consultant orthopaedic hand specialist and two specialist trainees, and the k coefficient for the inter- and intra-observer reliability of the type, group and subgroup classification was calculated.

Only the type of fracture (A, B or C) was found to provide substantial intra-observer reliability (k type 0.65). The inclusion of ‘group’ and ‘subgroup’ into the classification reduced the inter-observer reliability to fair (kgroup 0.29, ksubgroup = 0.28) and the intra-observer reliability to moderate (kgroup 0.53, ksubgroup 0.49). Disagreement was found to arise between specific subgroups, which may be amenable to clarification.

Cite this article: Bone Joint J 2015; 97-B:818–23.