The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 71 - 75
1 Jan 2015
Hoell S Borgers L Gosheger G Dieckmann R Schulz D Gerss J Hardes J

The purpose of this study was to evaluate whether the serum level of interleukin 6 (IL-6) could be used to identify the persistence of infection after the first stage of a two-stage revision for periprosthetic joint infection.

Between 2010 and 2011, we prospectively studied 55 patients (23 men, 32 women; mean age 69.5 years; 36 to 86) with a periprosthetic joint infection. Bacteria were identified in two intra-operative tissue samples during re-implantation in 16 patients. These cases were classified as representing persistent infection.

To calculate a precise cut-off value which could be used in everyday clinical practice, a 3 x 2 contingency table was constructed and manually defined.

We found that a serum IL-6 ≥ 13 pg/mL can be regarded as indicating infection: its positive-predictive value is 90.9%. A serum IL-6 ≤ 8 pg/mL can be regarded as indicating an absence of infection: its negative predictive value is 92.1%.

The serum IL-6 level seems to be a reasonable marker for identifying persistent infection after the first stage of a revision joint arthroplasty and before attempting re-implantation.

Cite this article: Bone Joint J 2015;97-B:71–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1237 - 1242
1 Sep 2009
Tanaka S Nishino J Matsui T Komiya A Nishimura K Tohma S

We examined the usefulness of neutrophil CD64 expression in detecting local musculoskeletal infection and the impact of antibiotics on its expression. Of 141 patients suspected of musculoskeletal infection, 46 were confirmed by microbiological culture to be infected and 95 had infection excluded. The median CD64 count of patients with localised infection was 2230 molecules per cell (interquartile range (IQR) 918 to 4592) and that of the patients without infection was 937 molecules per cell (IQR 648 to 1309) (p < 0.001). The level of CD64 correlated with the CRP level in patients with infection, but not in those without infection (r = 0.59, p < 0.01). Receiver operator characteristic curve analysis revealed that CD64 was a good predictor of local infection. When the patients were subdivided into two groups based on the administration of antibiotics at the time of CD64 sampling, the sensitivity for detecting infection was better in those who had not received antibiotics.

These results suggest that measurement of CD64 expression is a useful marker for local musculoskeletal infection.