Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1457 - 1461
1 Nov 2008
Lee K Chung J Song E Seon J Bai L

We describe the surgical technique and results of arthroscopic subtalar release in 17 patients (17 feet) with painful subtalar stiffness following an intra-articular calcaneal fracture of Sanders’ type II or III. The mean duration from injury to arthroscopic release was 11.3 months (6.4 to 36) and the mean follow-up after release was 16.8 months (12 to 25). The patient was positioned laterally and three arthroscopic portals were placed anterolaterally, centrally and posterolaterally. The sinus tarsi and lateral gutter were debrided of fibrous tissue and the posterior talocalcaneal facet was released. In all, six patients were very satisfied, eight were satisfied and three were dissatisfied with their results. The mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from a mean of 49.4 points (35 to 66) pre-operatively to a mean of 79.6 points (51 to 95). All patients reported improvement in movement of the subtalar joint. No complications occurred following operation, but two patients subsequently required subtalar arthrodesis for continuing pain. In the majority of patients a functional improvement in hindfoot function was obtained following arthroscopic release of the subtalar joint for stiffness and pain secondary to Sanders type II and III fractures of the calcaneum


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 447 - 453
1 Apr 2019
Sanders FRK Backes M Dingemans SA Hoogendoorn JM Schep NWL Vermeulen J Goslings JC Schepers T

Aims

The aim of this study was to evaluate the functional outcome in patients undergoing implant removal (IR) after fracture fixation below the level of the knee.

Patients and Methods

All adult patients (18 to 75 years) undergoing IR after fracture fixation below the level of the knee between November 2014 and September 2016 were included as part of the WIFI (Wound Infections Following Implant Removal Below the Knee) trial, performed in 17 teaching hospitals and two university hospitals in The Netherlands. In this multicentre prospective cohort, the primary outcome was the difference in functional status before and after IR, measured by the Lower Extremity Functional Scale (LEFS), with a minimal clinically important difference of nine points.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 5 - 11
1 Jan 2017
Vulcano E Myerson MS

The last decade has seen a considerable increase in the use of in total ankle arthroplasty (TAA) to treat patients with end-stage arthritis of the ankle. However, the longevity of the implants is still far from that of total knee and hip arthroplasties.

The aim of this review is to outline a diagnostic and treatment algorithm for the painful TAA to be used when considering revision surgery.

Cite this article: Bone Joint J 2017;99-B:5–11.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1088 - 1093
1 Aug 2013
Hsu W Lai L Chang H Hsu RW

It has been suggested that extracorporeal shockwave therapy is a safe and effective treatment for pain relief from recalcitrant plantar fasciopathy (PF). However, the changes in gait and associated biomechanical parameters have not been well characterised. We recruited 12 female patients with recalcitrant PF who had a mean age of 59 years (50 to 70) and mean body mass index of 25 kg/m2 (22 to 30). The patients reported a mean duration of symptoms of 9.3 months (6 to 15). Shockwave therapy consisting of 1500 impulses (energy flux density 0.26 mJ/mm2) was applied for three sessions, each three weeks apart. A pain visual analogue scale (VAS) rating, plantar pressure assessment and motion analysis were carried out before and nine weeks after first shock wave therapy. It was demonstrated that patients increased their walking velocity and cadence as well indicating a decrease in pain after shockwave therapy. In the symptomatic foot, the peak contact pressure over the forefoot increased and the contact area over the digits decreased. The total foot impulse also decreased as did stance duration. The duration the centre of pressure remained in the hindfoot increased in the symptomatic foot after shockwave therapy. The differences in centre of pressure trajectory at baseline decreased at final follow-up. In conclusion, shockwave therapy not only decreased the pain VAS rating but also improved the gait parameters of the symptomatic foot in PF patients.

Cite this article: Bone Joint J 2013;95-B:1088–93.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1659 - 1663
1 Dec 2010
Barg A Knupp M Hintermann B

The aim of this study was to compare the outcome of bilateral sequential total ankle replacement (TAR) with that of unilateral TAR. We reviewed 23 patients who had undergone sequential bilateral TAR under a single anaesthetic and 46 matched patients with a unilateral TAR. There were no significant pre-operative differences between the two groups in terms of age, gender, body mass index, American Society of Anaesthesiologists classification and aetiology of the osteoarthritis of the ankle. Clinical and radiological follow-up was carried out at four months, one and two years.

After four months, patients with simultaneous bilateral TAR reported a significantly higher mean pain score than those with a unilateral TAR. The mean American Orthopaedic Foot and Ankle Society hindfoot score and short-form 36 physical component summary score were better in the unilateral group. However, this difference disappeared at the one-and two-year follow-ups.

Bilateral sequential TAR under one anaesthetic can be offered to patients with bilateral severe ankle osteoarthritis. However, they should be informed of the long recovery period.