Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1340 - 1343
1 Oct 2007
Patil S Gandhi J Curzon I Hui ACW

Stable fractures of the ankle can be successfully treated non-operatively by a below-knee plaster cast. In some centres, patients with this injury are routinely administered low-molecular-weight heparin, to reduce the risk of deep-vein thrombosis (DVT). We have assessed the incidence of DVT in 100 patients in the absence of any thromboprophylaxis. A colour Doppler duplex ultrasound scan was done at the time of the removal of the cast.

Five patients did develop DVT, though none had clinical signs suggestive of it. One case involved the femoral and another the popliteal vein. No patient developed pulmonary embolism. As the incidence of DVT after ankle fractures is low, we do not recommend routine thromboprophylaxis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1117 - 1122
1 Aug 2005
Fuchs S Heyse T Rudofsky G Gosheger G Chylarecki C

There is a high risk of venous thromboembolism when patients are immobilised following trauma. The combination of low-molecular-weight heparin (LMWH) with graduated compression stockings is frequently used in orthopaedic surgery to try and prevent this, but a relatively high incidence of thromboembolic events remains. Mechanical devices which perform continuous passive motion imitate contractions and increase the volume and velocity of venous flow.

In this study 227 trauma patients were randomised to receive either treatment with the Arthroflow device and LMWH or only with the latter. The Arthroflow device passively extends and plantarflexes the feet. Patients were assessed initially by venous-occlusion plethysmography, compression ultrasonography and continuous wave Doppler, which were repeated weekly without knowledge of the category of randomisation. Those who showed evidence of deep-vein thrombosis underwent venography for confirmation. The incidence of deep-vein thrombosis was 25% in the LMWH group compared with 3.6% in those who had additional treatment with the Arthroflow device (p < 0.001). There were no substantial complications or problems of non-compliance with the Arthroflow device. Logistic regression analysis of the risk factors of deep-vein thrombosis showed high odds ratios for operation (4.1), immobilisation (4.3), older than 40 years of age (2.8) and obesity (2.2).