The aim of this study to compare 30-day survival and recovery of mobility between patients mobilized early (on the day of, or day after surgery for a hip fracture) and patients mobilized late (two days or more after surgery), and to determine whether the presence of dementia influences the association between the timing of mobilization, 30-day survival, and recovery. Analysis of the National Hip Fracture Database and hospital records for 126,897 patients aged ≥ 60 years who underwent surgery for a hip fracture in England and Wales between 2014 and 2016. Using logistic regression, we adjusted for covariates with a propensity score to estimate the association between the timing of mobilization, survival, and recovery of walking ability.Aims
Methods
To identify the prevalence of neuropathic pain after lower limb fracture surgery, assess associations with pain severity, quality of life and disability, and determine baseline predictors of chronic neuropathic pain at three and at six months post-injury. Secondary analysis of a UK multicentre randomized controlled trial (Wound Healing in Surgery for Trauma; WHiST) dataset including adults aged 16 years or over following surgery for lower limb major trauma. The trial recruited 1,547 participants from 24 trauma centres. Neuropathic pain was measured at three and six months using the Doleur Neuropathique Questionnaire (DN4); 701 participants provided a DN4 score at three months and 781 at six months. Overall, 933 participants provided DN4 for at least one time point. Physical disability (Disability Rating Index (DRI) 0 to 100) and health-related quality-of-life (EuroQol five-dimension five-level; EQ-5D-5L) were measured. Candidate predictors of neuropathic pain included sex, age, BMI, injury mechanism, concurrent injury, diabetes, smoking, alcohol, analgaesia use pre-injury, index surgery location, fixation type, Injury Severity Score, open injury, and wound care.Aims
Methods
The Edinburgh Trauma Triage Clinic (TTC) streamlines outpatient
care through consultant-led ‘virtual’ triage of referrals and the
direct discharge of minor fractures from the Emergency Department.
We compared the patient outcomes for simple fractures of the radial
head, little finger metacarpal, and fifth metatarsal before and
after the implementation of the TTC. A total of 628 patients who had sustained these injuries over
a one-year period were identified. There were 337 patients in the
pre-TTC group and 289 in the post-TTC group. The Disabilities of
the Arm, Shoulder and Hand Score (QuickDASH) or Foot and Ankle Disability
Index (FADI), EuroQol-5D (EQ-5D), visual analogue scale (VAS) pain
score, satisfaction rates, and return to work/sport were assessed
six months post-injury. The development of late complications was
excluded by an electronic record evaluation at three years post-injury.
A cost analysis was performed.Aims
Patients and Methods
The aim of this study was to evaluate near-infrared spectroscopy
(NIRS) as a continuous, non-invasive monitor for acute compartment
syndrome (ACS). NIRS sensors were placed on 86 patients with, and 23 without
(controls), severe leg injury. NIRS values were recorded for up
to 48 hours. Longitudinal data were analyzed using summary and graphical
methods, bivariate comparisons, and multivariable multilevel modelling.Aims
Patients and Methods
Fracture clinics are often characterised by the referral of large
numbers of unselected patients with minor injuries not requiring
investigation or intervention, long waiting times and recurrent
unnecessary reviews. Our experience had been of an unsustainable
system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order
to rationalise and regulate access to our fracture service. The
British Orthopaedic Association’s guidelines have required a prospective evaluation
of this change of practice, and we report our experience and results. We review the management of all 12 069 patients referred to our
service in the calendar year 2014, with a minimum of one year follow-up
during the calendar year 2015. Aims
Patients and Methods
The PROximal Fracture of the Humerus Evaluation by Randomisation
(PROFHER) randomised clinical trial compared the operative and non-operative
treatment of adults with a displaced fracture of the proximal humerus
involving the surgical neck. The aim of this study was to determine
the long-term treatment effects beyond the two-year follow-up. Of the original 250 trial participants, 176 consented to extended
follow-up and were sent postal questionnaires at three, four and
five years after recruitment to the trial. The Oxford Shoulder Score
(OSS; the primary outcome), EuroQol 5D-3L (EQ-5D-3L), and any recent
shoulder operations and fracture data were collected. Statistical
and economic analyses, consistent with those of the main trial were
applied.Aims
Patients and Methods
This study identifies early risk factors for symptomatic nonunion
of displaced midshaft fractures of the clavicle that aid identification
of an at risk group who may benefit from surgery. We performed a retrospective study of 88 patients aged between
16 and 60 years that were managed non-operatively. Aims
Methods
The most widely used classification system for
acetabular fractures was developed by Judet, Judet and Letournel over
50 years ago primarily to aid surgical planning. As population demographics
and injury mechanisms have altered over time, the fracture patterns
also appear to be changing. We conducted a retrospective review
of the imaging of 100 patients with a mean age of 54.9 years (19
to 94) and a male to female ratio of 69:31 seen between 2010 and
2013 with acetabular fractures in order to determine whether the
current spectrum of injury patterns can be reliably classified using
the original system. Three consultant pelvic and acetabular surgeons and one senior
fellow analysed anonymous imaging. Inter-observer agreement for
the classification of fractures that fitted into defined categories
was substantial, (κ = 0.65, 95% confidence interval (CI) 0.51 to
0.76) with improvement to near perfect on inclusion of CT imaging
(κ = 0.80, 95% CI 0.69 to 0.91). However, a high proportion of injuries
(46%) were felt to be unclassifiable by more than one surgeon; there
was moderate agreement on which these were (κ = 0.42 95% CI 0.31
to 0.54). Further review of the unclassifiable fractures in this cohort
of 100 patients showed that they tended to occur in an older population
(mean age 59.1 years; 22 to 94 Cite this article:
This study compares the cost-effectiveness of
treating dorsally displaced distal radial fractures with a volar
locking plate and percutaneous fixation. It was performed from the
perspective of the National Health Service (NHS) using data from
a single-centre randomised controlled trial. In total 130 patients
(18 to 73 years of age) with a dorsally displaced distal radial
fracture were randomised to treatment with either a volar locking
plate (n = 66) or percutaneous fixation (n = 64). The methodology
was according to National Institute for Health and Care Excellence guidance
for technology appraisals. . There were no significant differences in quality of life scores
between groups at any time point in the study. Both groups returned
to baseline one year post-operatively. NHS costs for the plate group were significantly higher (p <
0.001, 95% confidence interval 497 to 930). For an additional £713,
fixation with a volar locking plate offered 0.0178 additional quality-adjusted
life years in the year after surgery. The incremental cost-effectiveness
ratio (ICER) for plate fixation relative to percutaneous fixation
at list price was £40 068. When adjusting the prices of the implants
for a 20% hospital discount, the ICER was £31 898. Patients who
underwent plate fixation did not return to work earlier. We found no evidence to support the cost-effectiveness, from
the perspective of the NHS, of fixation using a volar locking plate
over percutaneous fixation for the operative treatment of a dorsally
displaced radial fracture. Cite this article:
The National Institute for Health and Clinical
Excellence (NICE) guidelines from 2011 recommend the use of cemented
hemi-arthroplasty for appropriate patients with an intracapsular
hip fracture. In our institution all patients who were admitted
with an intracapsular hip fracture and were suitable for a hemi-arthroplasty
between April 2010 and July 2012 received an uncemented prosthesis
according to our established departmental routine practice. A retrospective
analysis of outcome was performed to establish whether the continued
use of an uncemented stem was justified. Patient, surgical and outcome
data were collected on the National Hip Fracture database. A total
of 306 patients received a Cathcart modular head on a Corail uncemented
stem as a hemi-arthroplasty. The mean age of the patients was 83.3
years ( Cite this article:
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed. At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.
Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions. There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection. The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants. We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement.
There remains uncertainty about the most effective surgical approach in the treatment of complex fractures of the acetabulum. We have reviewed the experience of a single surgeon using the extended iliofemoral approach, as described by Letournel. A review of the database of such fractures identified 106 patients operated on using this approach with a minimum follow-up of two years. All data were collected prospectively. The fractures involved both columns in 64 (60%). Operation was undertaken in less than 21 days after injury in 71 patients (67%) and in 35 (33%) the procedure was carried out later than this. The reduction of the fracture was measured on plain radiographs taken after operation and defined as anatomical (0 to 1 mm of displacement); imperfect (2 to 3 mm) or poor (>
3 mm). The functional outcome was measured by the modified Merle d’Aubigné and Postel score. The mean follow-up was for 6.3 years (2 to 17). All patients achieved union of the fractures. The reduction was graded as anatomical in 76 (72%) of the patients, imperfect in 23 (22%), and poor in six (6%). The mean Merle d’Aubigné and Postel score was 15 (5 to 18) with 68 patients (64%) showing good or excellent and 38 (36%) fair or poor results. Function correlated significantly with the accuracy of the reduction (p <
0.009). Significant heterotopic ossification developed in 32 patients (30%) and was associated with a worse mean Merle d’Aubigné and Postel score of 13.7. The extended iliofemoral approach can be performed safely in selected complex acetabular fractures with an acceptable clinical outcome and rate of complications. Effective prophylaxis against heterotopic ossification should be strongly considered.
Limb-injury severity scores are designed to assess orthopaedic and vascular injuries. In Gustilo type-IIIA and type-IIIB injuries they have poor sensitivity and specificity to predict salvage or outcome. We have designed a trauma score to grade the severity of injury to the covering tissues, the bones and the functional tissues, grading the three components from one to five. Seven comorbid conditions known to influence the management and prognosis have been given a score of two each. The score was validated in 109 consecutive open injuries of the tibia, 42 type-IIIA and 67 type-IIIB. The total score was used to assess the possibilities of salvage and the outcome was measured by dividing the injuries into four groups according to their scores as follows: group I scored less than 5, group II 6 to 10, group III 11 to 15 and group IV 16 or more. A score of 14 to indicate amputation had the highest sensitivity and specificity. Our trauma score compared favourably with the Mangled Extremity Severity score in sensitivity (98% and 99%), specificity (100% and 17%), positive predictive value (100% and 97.5%) and negative predictive value (70% and 50%), respectively. A receiver-operating characteristic curve constructed for 67 type-IIIB injuries to assess the efficiency of the scores to predict salvage, showed that the area under the curve for this score was better (0.988 (± 0.013 The scoring system was found to be simple in application and reliable in prognosis for both limb-salvage and outcome measures in type-IIIA and type-IIIB open injuries of the tibia.