header advert
Results 1 - 20 of 78
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1445 - 1449
1 Nov 2013
Sonnadara R McQueen S Mironova P Safir O Nousiainen M Ferguson P Alman B Kraemer W Reznick R

Valid and reliable techniques for assessing performance are essential to surgical education, especially with the emergence of competency-based frameworks. Despite this, there is a paucity of adequate tools for the evaluation of skills required during joint replacement surgery. In this scoping review, we examine current methods for assessing surgeons’ competency in joint replacement procedures in both simulated and clinical environments. The ability of many of the tools currently in use to make valid, reliable and comprehensive assessments of performance is unclear. Furthermore, many simulation-based assessments have been criticised for a lack of transferability to the clinical setting. It is imperative that more effective methods of assessment are developed and implemented in order to improve our ability to evaluate the performance of skills relating to total joint replacement. This will enable educators to provide formative feedback to learners throughout the training process to ensure that they have attained core competencies upon completion of their training. This should help ensure positive patient outcomes as the surgical trainees enter independent practice.

Cite this article: Bone Joint J 2013;95-B:1445–9.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 817 - 823
1 Jul 2019
Vigdorchik J Eftekhary N Elbuluk A Abdel MP Buckland AJ Schwarzkopf RS Jerabek SA Mayman DJ

Aims

While previously underappreciated, factors related to the spine contribute substantially to the risk of dislocation following total hip arthroplasty (THA). These factors must be taken into consideration during preoperative planning for revision THA due to recurrent instability. We developed a protocol to assess the functional position of the spine, the significance of these findings, and how to address different pathologies at the time of revision THA.

Patients and Methods

Prospectively collected data on 111 patients undergoing revision THA for recurrent instability from January 2014 to January 2017 at two institutions were included (protocol group) and matched 1:1 to 111 revisions specifically performed for instability not using this protocol (control group). Mean follow-up was 2.8 years. Protocol patients underwent standardized preoperative imaging including supine and standing anteroposterior (AP) pelvis and lateral radiographs. Each case was scored according to the Hip-Spine Classification in Revision THA.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 44 - 49
1 Jan 2016
Sheth NP Melnic CM Paprosky WG

Given the increasing number of total hip arthroplasty procedures being performed annually, it is imperative that orthopaedic surgeons understand factors responsible for instability. In order to treat this potentially complex problem, we recommend correctly classifying the type of instability present based on component position, abductor function, impingement, and polyethylene wear. Correct classification allows the treating surgeon to choose the appropriate revision option that ultimately will allow for the best potential outcome.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):44–9.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims

Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years.

Patients and Methods

A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 230 - 234
1 Mar 1997
Leunig M Werlen S Ungersböck A Ito K Ganz R

Since January 1993 we have carried out MR arthrography on 23 patients with clinical symptoms and signs of abnormality of the acetabular labrum. Most of the patients were young adults. Such symptoms are known precursors of osteoarthritis, and therefore early and accurate evaluation is required.

We assessed the value of MR arthrography of the hip as a minimally-invasive diagnostic technique, in a prospective study and compared the findings with those at subsequent operations. All the patients complained of groin pain; 22 had a positive acetabular impingement test and 15 had radiological evidence of hip dysplasia.

In 21 of the patients, MR arthrography suggested either degeneration or a tear of the labrum or both. These findings were confirmed at operation in 18 patients, but there was no abnormality of the labrum in the other three. In two of the patients, MR arthrography erroneously suggested an intact labrum. Both MR arthrography and intraoperative inspection located lesions of the superior labrum most often, and these appeared slightly larger on arthrography than at operation.

We consider that MR arthrography is a promising diagnostic technique for the evaluation of abnormalities of the acetabular labrum.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1167 - 1171
1 Sep 2014
Khan O Witt J

The cam-type deformity in femoroacetabular impingement is a 3D deformity. Single measurements using radiographs, CT or MRI may not provide a true estimate of the magnitude of the deformity. We performed an analysis of the size and location of measurements of the alpha angle (α°) using a CT technique which could be applied to the 3D reconstructions of the hip. Analysis was undertaken in 42 patients (57 hips; 24 men and 18 women; mean age 38 years (16 to 58)) who had symptoms of femoroacetabular impingement related to a cam-type abnormality. An α° of > 50° was considered a significant indicator of cam-type impingement. Measurements of the α° were made at different points around the femoral head/neck junction at intervals of 30°: starting at the nine o’clock (posterior), ten, eleven and twelve o’clock (superior), one, two and ending at three o’clock (anterior) position.

The mean maximum increased α° was 64.6° (50.8° to 86°). The two o’clock position was the most common point to find an increased α° (53 hips; 93%), followed by one o’clock (48 hips; 84%). The largest α° for each hip was found most frequently at the two o’clock position (46%), followed by the one o’clock position (39%). Generally, raised α angles extend over three segments of the clock face.

Single measurements of the α°, whether pre- or post-operative, should be viewed with caution as they may not be representative of the true size of the deformity and not define whether adequate correction has been achieved following surgery.

Cite this article: Bone Joint J 2014;96-B:1167–71.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 191 - 194
1 Mar 1996
McCaskie AW Brown AR Thompson JR Gregg PJ

Three radiological methods are commonly used to assess the outcome of total hip replacement (THR). They aim to record the appearance of lucent areas and migration of the prosthesis in a reproducible manner. Two of them were designed to monitor the implant through time and one to grade the quality of cementing. We have measured the level of inter- and intraobserver agreement in all three systems.

We randomised 30 patients to receive either finger packing or retrograde gun cementing during Charnley hip replacements. The postoperative departmental radiographs were evaluated in a blinded study by two orthopaedic trainees, two consultants and two experts in THR. The trainees and consultants repeated the exercise at least two weeks later. We used the unweighted kappa statistic to establish the levels of agreement.

In general, intraobserver agreement was moderate but interobserver agreement was poor, with levels similar to or less than those expected by chance. Our results indicate that such systems cannot provide reliable data from centres in different parts of the world, with various levels of surgeon evaluating radiographs at differing time intervals. We discuss the problem and suggest some methods of improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 724 - 730
1 Jun 2008
Hartofilakidis G Georgiades G Babis GC Yiannakopoulos CK

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16).

Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis.

In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 922 - 928
1 Aug 2022
Png ME Petrou S Fernandez MA Achten J Parsons N McGibbon A Gould J Griffin XL Costa ML

Aims. The aim of this study was to compare the cost-effectiveness of cemented hemiarthroplasty (HA) versus hydroxyapatite-coated uncemented HA for the treatment of displaced intracapsular hip fractures in older adults. Methods. A within-trial economic evaluation was conducted based on data collected from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized controlled trial in the UK. Resource use was measured over 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from the NHS and personal social service perspective. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was represented graphically using confidence ellipses and cost-effectiveness acceptability curves. Results. The base-case analysis showed that cemented implants were cost-saving (mean cost difference -£961 (95% confidence interval (CI) -£2,292 to £370)) and increased QALYs (mean QALY difference 0.010 (95% CI 0.002 to 0.017)) when compared to uncemented implants. The probability of the cemented implant being cost-effective approximated between 95% and 97% at alternative cost-effectiveness thresholds held by decision-makers, and its net monetary benefit was positive. The findings remained robust against all the pre-planned sensitivity analyses. Conclusion. This study shows that cemented HA is cost-effective compared with hydroxyapatite-coated uncemented HA in older adults with displaced intracapsular hip fractures. Cite this article: Bone Joint J 2022;104-B(8):922–928


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1252 - 1258
1 Dec 2023
Tanabe H Baba T Ozaki Y Yanagisawa N Homma Y Nagao M Kaneko K Ishijima M

Aims. Lateral femoral cutaneous nerve (LFCN) injury is a potential complication after the direct anterior approach for total hip arthroplasty (DAA-THA). The aim of this study was to determine how the location of the fasciotomy in DAA-THA affects LFCN injury. Methods. In this trial, 134 patients were randomized into a lateral fasciotomy (n = 67) or a conventional fasciotomy (n = 67) group. This study was a dual-centre, double-blind, prospective randomized controlled two-arm trial with parallel group design and a 1:1 allocation ratio. The primary endpoint was the presence of LFCN injury, which was determined by the presence of numbness, decreased sensation, tingling, jolt-like sensation, or pain over the lateral aspect of the thigh, excluding the surgical scar, using a patient-based questionnaire. The secondary endpoints were patient-reported outcome measures (PROMs) using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ), and the Forgotten Joint Score-12 (FJS-12). Assessments were obtained three months after surgery. Results. The incidence of LFCN injury tended to be lower in the lateral fasciotomy group (p = 0.089). In the lateral fasciotomy group, there were no significant differences in the mean PROM scores between patients with and without LFCN injury (FJS-12: 54.42 (SD 15.77) vs 65.06 (SD 26.14); p = 0.074; JHEQ: 55.21 (SD 12.10) vs 59.72 (SD 16.50); p = 0.288; WOMAC: 82.45 (SD 6.84) vs 84.40 (SD 17.91); p = 0.728). In the conventional fasciotomy group, there were significant differences in FJS-12 and JHEQ between patients with and without LFCN injury (FJS-12: 43.21 (SD 23.08) vs 67.28 (SD 20.47); p < 0.001; JHEQ: 49.52 (SD 13.97) vs 59.59 (SD 15.18); p = 0.012); however, there was no significant difference in WOMAC (76.63 (SD 16.81) vs 84.16 (SD 15.94); p = 0.107). Conclusion. The incidence of LFCN injury at three months after THA was comparable between the lateral and conventional fasciotomy groups. Further studies are needed to assess the long-term effects of these approaches. Cite this article: Bone Joint J 2023;105-B(12):1252–1258


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 656 - 661
1 Jul 2024
Bolbocean C Hattab Z O'Neill S Costa ML

Aims. Cemented hemiarthroplasty is an effective form of treatment for most patients with an intracapsular fracture of the hip. However, it remains unclear whether there are subgroups of patients who may benefit from the alternative operation of a modern uncemented hemiarthroplasty – the aim of this study was to investigate this issue. Knowledge about the heterogeneity of treatment effects is important for surgeons in order to target operations towards specific subgroups who would benefit the most. Methods. We used causal forest analysis to compare subgroup- and individual-level treatment effects between cemented and modern uncemented hemiarthroplasty in patients aged > 60 years with an intracapsular fracture of the hip, using data from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized clinical trial. EuroQol five-dimension index scores were used to measure health-related quality of life at one, four, and 12 months postoperatively. Results. Our analysis revealed a complex landscape of responses to the use of a cemented hemiarthroplasty in the 12 months after surgery. There was heterogeneity of effects with regard to baseline characteristics, including age, pre-injury health status, and lifestyle factors such as alcohol consumption. This heterogeneity was greater at the one-month mark than at subsequent follow-up timepoints, with particular regard to subgroups based on age. However, for all subgroups, the effect estimates for quality of life lay within the confidence intervals derived from the analysis of all patients. Conclusion. The use of a cemented hemiarthroplasty is expected to increase health-related quality of life compared with modern uncemented hemiarthroplasty for all subgroups of patients aged > 60 years with a displaced intracapsular fracture of the hip. Cite this article: Bone Joint J 2024;106-B(7):656–661


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 659 - 664
1 Apr 2021
Doi N Kinoshita K Sakamoto T Minokawa A Setoguchi D Yamamoto T

Aims. Injury to the lateral femoral cutaneous nerve (LFCN) is one of the known complications after periacetabular osteotomy (PAO) performed using the anterior approach, reported to occur in between 1.5% and 65% of cases. In this study, we performed a prospective study on the incidence of LFCN injury as well as its clinical outcomes based on the Harris Hip Score (HHS), Short-Form 36 Health Survey (SF-36), and Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ). Methods. The study included 42 consecutive hips in 42 patients (three male and 39 female) who underwent PAO from May 2016 to July 2018. We prospectively evaluated the incidence of LFCN injury at ten days, three months, six months, and one year postoperatively. We also evaluated the clinical scores, including the HHS, SF-36, and JHEQ scores, at one year postoperatively. Results. LFCN injury was observed in 31 of 42 (74%) patients at ten days, of which 11 resolved completely by one year. Incidence decreased gradually, to 25 of 42 (60%) patients at three months, 24 of 42 patients (57%) at six months, and 20 of 42 (48%) patients at one year postoperatively. There was no significant difference in the HHS between patients with and without LFCN injury at one year postoperatively. Regarding the SF-36 and JHEQ, a significant difference in the mental score was recognized between patients with and without LFCN injury, but there were no significant differences in the other clinical scores. Conclusion. The incidence of LFCN injury was 74% at ten days after PAO, and subsequently decreased to 48% at one year. LFCN injury did not influence the hip function as assessed by the HHS, but had a negative impact on mental health at one year. Cite this article: Bone Joint J 2021;103-B(4):659–664


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 665 - 671
1 Apr 2021
Osawa Y Seki T Okura T Takegami Y Ishiguro N Hasegawa Y

Aims. We compared the clinical outcomes of curved intertrochanteric varus osteotomy (CVO) with bone impaction grafting (BIG) with CVO alone for the treatment of osteonecrosis of the femoral head (ONFH). Methods. This retrospective comparative study included 81 patients with ONFH; 37 patients (40 hips) underwent CVO with BIG (BIG group) and 44 patients (47 hips) underwent CVO alone (CVO group). Patients in the BIG group were followed-up for a mean of 12.2 years (10.0 to 16.5). Patients in the CVO group were followed-up for a mean of 14.5 years (10.0 to 21.0). Assessment parameters included the Harris Hip Score (HHS), Oxford Hip Score (OHS), Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ), complication rates, and survival rates, with conversion to total hip arthroplasty (THA) and radiological failure as the endpoints. Results. There were no significant differences in preoperative and postoperative HHS or postoperative OHS and JHEQ between the BIG group and the CVO group. Complication rates were comparable between groups. Ten-year survival rates with conversion to THA and radiological failure as the endpoints were not significantly different between groups. Successful CVO (postoperative coverage ratio of more than one-third) exhibited better ten-year survival rates with radiological failure as the endpoint in the BIG group (91.4%) than in the CVO group (77.7%), but this difference was not significant (p = 0.079). Conclusion. Long-term outcomes of CVO with BIG were favourable when proper patient selection and accurate surgery are performed. However, this study did not show improvements in treatment results with the concomitant use of BIG. Cite this article: Bone Joint J 2021;103-B(4):665–671


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 536 - 539
1 May 2019
Cassidy RS O hEireamhoin S Beverland DE

Aims. The aim of this retrospective audit was to determine the route of referral or presentation of patients requiring revision following primary total hip arthroplasty (THA). Patients and Methods. A total of 4802 patients were implanted with an Orthopaedic Data Evaluation Panel (ODEP) 10A* cementless implant (Corail/Pinnacle) between 2005 and 2015; 80 patients with a mean age of 67.8 years (. sd. 10.8) underwent a subsequent revision. The primary outcome measure was route of referral for revision. Results. Of the 80 revisions, 31 (38.8%) took place within the first year and 69 (86.3%) took place within six years. Only two of the 80 patients were picked up at a routine review clinic, one for infection and the other for liner dissociation. A total of 36 revised patients (45.0%) were reviewed following self-referral. Of the remaining 44 revised patients (55.0%), 15 (18.8%) were General Practitioner referrals, 13 (16.3%) were other hospital referrals, six (7.5%) were inpatients, six (7.5%) were Emergency Department referrals, and two (2.5%) were readmitted from their homes. No revisions were carried out on asymptomatic patients. Conclusion. Our experience suggests that if there is a robust system in place for self-referral, patients with an ODEP 10A* hip implant can, if asymptomatic, be safely discharged at the time of their first postoperative review. Cite this article: Bone Joint J 2019;101-B:536–539


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims

To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time.

Methods

We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 792 - 801
1 Aug 2024
Kleeman-Forsthuber L Kurkis G Madurawe C Jones T Plaskos C Pierrepont JW Dennis DA

Aims

Spinopelvic pathology increases the risk for instability following total hip arthroplasty (THA), yet few studies have evaluated how pathology varies with age or sex. The aims of this study were: 1) to report differences in spinopelvic parameters with advancing age and between the sexes; and 2) to determine variation in the prevalence of THA instability risk factors with advancing age.

Methods

A multicentre database with preoperative imaging for 15,830 THA patients was reviewed. Spinopelvic parameter measurements were made by experienced engineers, including anterior pelvic plane tilt (APPT), spinopelvic tilt (SPT), sacral slope (SS), lumbar lordosis (LL), and pelvic incidence (PI). Lumbar flexion (LF), sagittal spinal deformity, and hip user index (HUI) were calculated using parameter measurements.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1196 - 1201
1 Nov 2022
Anderson CG Brilliant ZR Jang SJ Sokrab R Mayman DJ Vigdorchik JM Sculco PK Jerabek SA

Aims

Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods.

Methods

In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 504 - 510
1 May 2023
Evans JT Salar O Whitehouse SL Sayers A Whitehouse MR Wilton T Hubble MJW

Aims

The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for primary total hip arthroplasty (THA). In 2004, the 44/00/125 stem was released for use in ‘cement-in-cement’ revision cases. It has, however, been used ‘off-label’ as a primary stem when patient anatomy requires a smaller stem with a 44 mm offset. We aimed to investigate survival of this implant in comparison to others in the range when used in primary THAs recorded in the NJR.

Methods

We analyzed 328,737 primary THAs using the Exeter V40 stem, comprising 34.3% of the 958,869 from the start of the NJR to December 2018. Our exposure was the stem, and the outcome was all-cause construct revision. We stratified analyses into four groups: constructs using the 44/00/125 stem, those using the 44/0/150 stem, those including a 35.5/125 stem, and constructs using any other Exeter V40 stem.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 540 - 547
1 Jun 2024
Nandra RS Elnahal WA Mayne A Brash L McBryde CW Treacy RBC

Aims

The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years.

Methods

The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken.