Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 860 - 866
1 Jul 2019
Nicholson JA Searle HKC MacDonald D McBirnie J

Aims. The aim of this study was to investigate the influence of age on the cost-effectiveness of arthroscopic rotator cuff repair. Patients and Methods. A total of 112 patients were prospectively monitored for two years after arthroscopic rotator cuff repair using the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH), the Oxford Shoulder Score (OSS), and the EuroQol five-dimension questionnaire (EQ-5D). Complications and use of healthcare resources were recorded. The incremental cost-effectiveness ratio (ICER) was used to express the cost per quality-adjusted life-year (QALY). Propensity score-matching was used to compare those aged below and above 65 years of age. Satisfaction was determined using the Net Promoter Score (NPS). Linear regression was used to identify variables that influenced the outcome at two years postoperatively. Results. A total of 92 patients (82.1%) completed the follow-up. Their mean age was 59.5 years (. sd. 9.7, 41 to 78). There were significant improvements in the mean DASH (preoperative 47.6 vs one-year 15.3; p < 0.001) and OSS scores (26.5 vs 40.5; p < 0.001). Functional improvements were maintained with no significant change between one and two years postoperatively. The mean preoperative EQ-5D was 0.54 increasing to 0.81 at one year (p < 0.001) and maintained at 0.86, two years postoperatively. There was no significant difference between those aged below or above 65 years of age with regards to postoperative shoulder function or EQ-5D gains. Smoking was the only characteristic that significantly adversely influenced the EQ-5D at two years postoperatively (p = 0.005). A total of 87 were promoters and five were passive, giving a mean NPS of 95 (87/92). The total mean cost per patient was £3646.94 and the mean EQ-5D difference at one year was 0.2691, giving a mean ICER of £13 552.36/QALY. At two years, this decreased further to £5694.78/QALY. This was comparable for those aged below or above 65 years of age (£5209.91 vs £5525.67). Smokers had an ICER that was four times more expensive. Conclusion. Arthroscopic rotator cuff repair results in excellent patient satisfaction and cost-effectiveness, regardless of age. Cite this article: Bone Joint J 2019;101-B:860–866


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 55 - 62
1 Jan 2019
Rombach I Merritt N Shirkey BA Rees JL Cook JA Cooper C Carr AJ Beard DJ Gray AM

Aims. The aims of this study were to compare the use of resources, costs, and quality of life outcomes associated with subacromial decompression, arthroscopy only (placebo surgery), and no treatment for subacromial pain in the United Kingdom National Health Service (NHS), and to estimate their cost-effectiveness. Patients and Methods. The use of resources, costs, and quality-adjusted life-years (QALYs) were assessed in the trial at six months and one year. Results were extrapolated to two years after randomization. Differences between treatment arms, based on the intention-to-treat principle, were adjusted for covariates and missing data were handled using multiple imputation. Incremental cost-effectiveness ratios were calculated, with uncertainty around the values estimated using bootstrapping. Results. Cumulative mean QALYs/mean costs of health care service use and surgery per patient from baseline to 12 months were estimated as 0.640 (standard error (. se. ) 0.024)/£3147 (. se. 166) in the decompression arm, 0.656 (. se. 0.020)/£2830 (. se. 183) in the arthroscopy only arm and 0.522 (. se. 0.029)/£1451 (. se. 151) in the no treatment arm. Statistically significant differences in cumulative QALYs and costs were found at six and 12 months for the decompression versus no treatment comparison only. The probabilities of decompression being cost-effective compared with no treatment at a willingness-to-pay threshold of £20 000 per QALY were close to 0% at six months and approximately 50% at one year, with this probability potentially increasing for the extrapolation to two years. Discussion. The evidence for cost-effectiveness at 12 months was inconclusive. Decompression could be cost-effective in the longer-term, but results of this analysis are sensitive to the assumptions made about how costs and QALYs are extrapolated beyond the follow-up of the trial


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims

Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS).

Methods

Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims

Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning.

Methods

A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims

The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair.

Patients and Methods

All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1648 - 1655
1 Dec 2016
Murphy J Gray A Cooper C Cooper D Ramsay C Carr A

Aims

A trial-based comparison of the use of resources, costs and quality of life outcomes of arthroscopic and open surgical management for rotator cuff tears in the United Kingdom NHS was performed using data from the United Kingdom Rotator Cuff Study (UKUFF) randomised controlled trial.

Patients and Methods

Using data from 273 patients, healthcare-related use of resources, costs and quality-adjusted life years (QALYs) were estimated at 12 months and 24 months after surgery on an intention-to-treat basis with adjustment for covariates. Uncertainty about the incremental cost-effectiveness ratio for arthroscopic versus open management at 24 months of follow-up was incorporated using bootstrapping. Multiple imputation methods were used to deal with missing data.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 799 - 805
1 Jun 2017
Ketola S Lehtinen JT Arnala I

Aims

Rotator cuff tendinopathy has a multifactorial origin. Rejecting the mechanistic theory has also led to abandoning operative treatment at initial presentation in the first line. Physiotherapy exercise programmes are the accepted first line treatment. The aim of this study was to assess the long-term additional benefits of subacromial decompression in the treatment of rotator cuff tendinopathy.

Patients and Methods

This randomised controlled trial of 140 patients (52 men, 88 women, mean age 47.1 years; 18 to 60) with rotator cuff tendinopathy extended previous work up to a maximum of 13 years. The patients were randomised into two treatment groups: arthroscopic acromioplasty and a supervised exercise treatment and a similar supervised exercise treatment alone. Self-reported pain on a visual analogue scale (VAS) was the primary outcome measure. Secondary measures were disability, working ability, pain at night, Shoulder Disability Questionnaire score and the number of painful days during the three months preceding the final assessment.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 245 - 249
1 Feb 2017
Barnes LAF Kim HM Caldwell J Buza J Ahmad CS Bigliani LU Levine WN

Aims

Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years.

Patients and Methods

We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 70 - 74
1 Jan 2014
Judge A Murphy RJ Maxwell R Arden NK Carr AJ

We explored the trends over time and the geographical variation in the use of subacromial decompression and rotator cuff repair in 152 local health areas (Primary Care Trusts) across England. The diagnostic and procedure codes of patients undergoing certain elective shoulder operations between 2000/2001 and 2009/2010 were extracted from the Hospital Episode Statistics database. They were grouped as 1) subacromial decompression only, 2) subacromial decompression with rotator cuff repair, and 3) rotator cuff repair only.

The number of patients undergoing subacromial decompression alone rose by 746.4% from 2523 in 2000/2001 (5.2/100 000 (95% confidence interval (CI) 5.0 to 5.4) to 21 355 in 2009/2010 (40.2/100 000 (95% CI 39.7 to 40.8)). Operations for rotator cuff repair alone peaked in 2008/2009 (4.7/100 000 (95% CI 4.5 to 4.8)) and declined considerably in 2009/2010 (2.6/100 000 (95% CI 2.5 to 2.7)).

Given the lack of evidence for the effectiveness of these operations and the significant increase in the number of procedures being performed in England and elsewhere, there is an urgent need for well-designed clinical trials to determine evidence of clinical effectiveness.

Cite this article: Bone Joint J 2014;96-B:70–4.