We describe a technique for arthroscopy of the wrist which is carried out without traction and with the arm lying horizontally on the operating table. The wrist is not immobilised, which makes it possible to assess the extent of instability after a ligamentous tear. In a prospective study of 30 patients we compared this technique with
We used magnetic resonance (MR) myelography in ten patients with injuries to the brachial plexus and compared the findings with those obtained by
In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the
We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which
Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on
We studied the stability of cemented all-polyethylene keeled glenoid components by radiostereometric analysis (RSA) in 16 shoulders which had received a total shoulder replacement. There were 14 women (one bilateral) and one man with a mean age of 64 years. The diagnosis was osteoarthritis in eight and rheumatoid arthritis in seven. Two of the shoulders were excluded from the RSA study because of loosening of the tantalum markers. Three tantalum markers were inserted in the glenoid socket, two in the coracoid process and two in the acromion. The polyethylene keeled glenoid component was marked with three to five tantalum markers.
Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p <
0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by
In 13 patients (18 fingers) we used two types of external fixator as progressive static splints for the preoperative correction of the deformities of severe Dupuytren’s disease before
We have treated 22 patients with an elbow contracture using a static progressive turnbuckle splint for a mean of 4.5 ± 1.8 months. All had failed to improve with supervised physiotherapy and splinting. The mean range of flexion before splintage was from 32 ± 10° to 108 ± 19° and afterwards from 26 ± 10° (p = 0.02) to 127 ± 12° (p = 0.0001). A total of 11 patients gained a ‘functional arc of movement,’ defined as at least 30° to 130°. In eight patients movement improved with turnbuckle splinting, but the functional arc was not achieved. Six of these were satisfied and did not wish to proceed with surgical treatment and two had release of the elbow contracture. In three patients movement did not improve with the use of the turnbuckle splint and one subsequently had surgical treatment. Our findings have shown that turnbuckle splinting is a safe and effective treatment which should be considered in patients whose established elbow contractures have failed to respond to
We have treated 16 patients with recurrent complex elbow instability using a hinged external fixator. All patients had instability, dislocation or subluxation of the ulnohumeral joint. The injuries were open in eight patients and were associated with 20 other fractures and five peripheral nerve injuries. Two patients had received initial treatment from us; 14 had previously had a mean of 2.1 unsuccessful surgical procedures (1 to 6). The fixator was applied at a mean of 4.8 weeks (0 to 9) after the injury and remained on the elbow for a mean of 8.5 weeks (6 to 11). After treatment we found the mean range of flexion-extension to be 105° (65 to 140). At a final follow-up of 23 months (14 to 40), the mean Morrey score was 84 (49 to 96): this translated into one poor, three fair, ten good and two excellent results. Complications included one fractured humeral pin, one temporary palsy of the radial nerve, one recurrent instability, one wound infection, one severe pin-track infection and one patient with reflex sympathetic dystrophy. Although technically demanding, the use of the fixator is an important advance in the management of recurrent complex elbow instability after failure of
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
Frozen shoulder is commonly encountered in general
orthopaedic practice. It may arise spontaneously without an obvious
predisposing cause, or be associated with a variety of local or
systemic disorders. Diagnosis is based upon the recognition of the
characteristic features of the pain, and selective limitation of
passive external rotation. The macroscopic and histological features
of the capsular contracture are well-defined, but the underlying
pathological processes remain poorly understood. It may cause protracted
disability, and imposes a considerable burden on health service
resources. Most patients are still managed by physiotherapy in primary
care, and only the more refractory cases are referred for specialist
intervention. Targeted therapy is not possible and treatment remains predominantly
symptomatic. However, over the last ten years, more active interventions
that may shorten the clinical course, such as capsular distension
arthrography and arthroscopic capsular release, have become more popular. This review describes the clinical and pathological features
of frozen shoulder. We also outline the current treatment options,
review the published results and present our own treatment algorithm.
Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p <
0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved.
We hypothesised that a large acromial cover with
an upwardly tilted glenoid fossa would be associated with degenerative
rotator cuff tears (RCTs), and conversely, that a short acromion
with an inferiorly inclined glenoid would be associated with glenohumeral
osteoarthritis (OA). This hypothesis was tested using a new radiological parameter,
the critical shoulder angle (CSA), which combines the measurements
of inclination of the glenoid and the lateral extension of the acromion
(the acromion index). The CSA was measured on standardised radiographs of three groups:
1) a control group of 94 asymptomatic shoulders with normal rotator
cuffs and no OA; 2) a group of 102 shoulders with MRI-documented
full-thickness RCTs without OA; and 3) a group of 102 shoulders
with primary OA and no RCTs noted during total shoulder replacement.
The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0°
(29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in
the OA group. Of patients with a CSA >
35°, 84% were in the RCT
group and of those with a CSA <
30°, 93% were in the OA group. We therefore concluded that primary glenohumeral OA is associated
with significantly smaller degenerative RCTs with significantly
larger CSAs than asymptomatic shoulders without these pathologies.
These findings suggest that individual quantitative anatomy may
imply biomechanics that are likely to induce specific types of degenerative
joint disorders. Cite this article:
This study was performed to determine whether
pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient
to achieve bony union and restore alignment in scaphoid nonunion.
A total of 65 patients who underwent cancellous bone graft and K-wire
fixation were included in this study. The series included 61 men
and four women with a mean age of 34 years (15 to 72) and mean delay
to surgery of 28.7 months (3 to 240). The patients were divided
into an unstable group (A) and stable group (B) depending on the
pre-operative radiographs. Unstable nonunion was defined as a lateral
intrascaphoid angle >
45°, or a radiolunate angle >
10°. There were
34 cases in group A and 31 cases in group B. Bony union was achieved
in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B
(p = 0.439). Comparison of the post-operative radiographs between
the two groups showed no significant differences in lateral intrascaphoid
angle (p = 0.657) and scaphoid length
(p = 0.670) and height (p = 0.193). The radiolunate angle was significantly
different
(p = 0.020) but the mean value in both groups was <
10°. Comparison
of the dorsiflexion and palmar flexion of movement of the wrist
and the mean Mayo wrist score at the final clinical visit in each
group showed no significant difference (p = 0.190, p = 0.587 and
p = 0.265, respectively). Cancellous bone graft and K-wire fixation
were effective in the treatment of stable and unstable scaphoid
nonunion. Cite this article:
We undertook a prospective study in 51 male patients aged between 17 and 27 years to ascertain whether immobilisation after primary traumatic anterior dislocation of the shoulder in external rotation was more effective than immobilisation in internal rotation in preventing recurrent dislocation in a physically active population. Of the 51 patients, 24 were randomised to be treated by a traditional brace in internal rotation and 27 were immobilised in external rotation of 15° to 20°. After immobilisation, the patients undertook a standard regime of physiotherapy and were then assessed clinically for evidence of instability. When reviewed at a mean of 33.4 months (24 to 48) ten from the external rotation group (37%) and ten from the internal rotation group (41.7%) had sustained a futher dislocation. There was no statistically significant difference (p = 0.74) between the groups. Our findings show that external rotation bracing may not be as effective as previously reported in preventing recurrent anterior dislocation of the shoulder.
Bone loss involving articular surface is a challenging
problem faced by the orthopaedic surgeon. In the hand and wrist,
there are articular defects that are amenable to autograft reconstruction
when primary fixation is not possible. In this article, the surgical
techniques and clinical outcomes of articular reconstructions in
the hand and wrist using non-vascularised osteochondral autografts
are reviewed.
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
Dislocation of the shoulder may occur during
seizures in epileptics and other patients who have convulsions. Following
the initial injury, recurrent instability is common owing to a tendency
to develop large bony abnormalities of the humeral head and glenoid
and a susceptibility to further seizures. Assessment is difficult
and diagnosis may be missed, resulting in chronic locked dislocations
with protracted morbidity. Many patients have medical comorbidities,
and successful treatment requires a multidisciplinary approach addressing
the underlying seizure disorder in addition to the shoulder pathology.
The use of bony augmentation procedures may have improved the outcomes
after surgical intervention, but currently there is no evidence-based
consensus to guide treatment. This review outlines the epidemiology
and pathoanatomy of seizure-related instability, summarising the
currently-favoured options for treatment, and their results.