Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 549 - 556
1 Apr 2007
Udofia I Liu F Jin Z Roberts P Grigoris P

Finite element analysis was used to examine the initial stability after hip resurfacing and the effect of the procedure on the contact mechanics at the articulating surfaces. Models were created with the components positioned anatomically and loaded physiologically through major muscle forces. Total micromovement of less than 10 μm was predicted for the press-fit acetabular components models, much below the 50 μm limit required to encourage osseointegration. Relatively high compressive acetabular and contact stresses were observed in these models. The press-fit procedure showed a moderate influence on the contact mechanics at the bearing surfaces, but produced marked deformation of the acetabular components. No edge contact was predicted for the acetabular components studied.

It is concluded that the frictional compressive stresses generated by the 1 mm to 2 mm interference-fit acetabular components, together with the minimal micromovement, would provide adequate stability for the implant, at least in the immediate post-operative situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 839 - 839
1 Jun 2006
ROBERTS P GRIGORIS P


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 25 - 27
1 Jan 1993
Grigoris P Roberts P McMinn D Villar R

We describe a simple, retroperitoneal approach for the removal of acetabular components that have migrated into the pelvis. The dense fibrous tissue layer which surrounds the implant protects the iliac vessels during removal of the cup by this method.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 265 - 269
1 Mar 1992
Roberts P Walters A McMinn D

In 78 consecutive patients, we performed fine-needle aspiration of the hip before revision surgery. At the revision operation biopsies were taken from the capsule and joint tissues. The aspirate and the homogenised soft-tissue specimens were cultured using a radiometric technique. Fifteen hips proved to be infected and 63 sterile on culture of the tissues taken during revision surgery; 94% of the aspiration results were correct. The sensitivity of the technique was 87% and the specificity 95%. Fine-needle aspiration combined with a radiometric culture technique is a simple and reliable method of diagnosing infection of hip prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 899 - 901
1 Nov 1991
McMinn D Roberts P Forward G

A new approach to the hip is described that allows better exposure for difficult revision surgery without the need for trochanteric osteotomy. A V-shaped myofascial flap consisting of the proximal part of vastus lateralis and its fascia with gluteus medius and minimus, is reflected off the greater trochanter and proximal femur giving access to the entire capsule of the hip. If the leg has been significantly lengthened by the revision procedure, abductor tension can be adjusted at closure by altering the reattachment of the flap, analogous to a V-Y-plasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 762 - 769
1 Sep 1991
Roberts P Chan D Grimer R Sneath R Scales J

Over a 16-year period, 135 custom-made distal femoral prostheses, based on a fully constrained Stanmore-type knee replacement, were used in the treatment of primary malignant or aggressive benign tumours. Survivorship analysis showed a cumulative success rate of 72% at five years and 64% at seven years. Intact prostheses in 91% of the surviving patients gave good or excellent functional results. Deep infection was the major complication, occurring in 6.8% of cases; clinical aseptic loosening occurred in 6.0%. Revision surgery was carried out for loosening and infection, and the early results are encouraging. We conclude that prosthetic replacement of the distal femur can meet the objectives of limb salvage surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 620 - 621
1 Jul 1990
Roberts P Carnes S

The orthopaedic scooter is an alternative to crutches. It gives the patient greater freedom on level smooth surfaces and uses less energy.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 213 - 221
1 May 1977
Roberts P Price C

Nineteen chondrosarcomas are reported arising in proximal phalanges or metacarpal bones of the hand mainly in elderly patients, predominantly women. The usual clinical presentation was of a progressively painful large tumour, often arising in a dormant lesion near the metacarpo-phalangeal joint. Radiologically most showed some bone expansion with a poorly defined area of destruction and a considerable soft-tissue swelling. Histologically, malignancy was usually obvious, but confusion might arise from the inclusion of bland areas of chondromatous tissue that probably represented the original lesion. Four tumours, initially curetted and grafted, recurred locally and necessitated amputation of the digit or ray. Amputation was the primary treatment for fourteen other tumours and was curative except in one patient who eventually needed amputation through the forearm for a large second recurrence. One tumour was satisfactorily controlled by excision of the affected phalanx. None of these nineteen tumours is known to have metastasised. Correct treatment implies a carefully considered balance between conservation of function and complete removal of all tumour tissue.