Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar
The shape of the flexion gap in 20 normal knees was evaluated by axial
Radiological residual acetabular dysplasia (RAD) has been reported in up to 30% of children who had successful brace treatment of infant developmental dysplasia of the hip (DDH). Predicting those who will resolve and those who may need corrective surgery is important to optimize follow-up protocols. In this study we have aimed to identify the prevalence and predictors of RAD at two years and five years post-bracing. This was a single-centre, prospective longitudinal cohort study of infants with DDH managed using a published, standardized Pavlik harness protocol between January 2012 and December 2016. RAD was measured at two years’ mean follow-up using acetabular index-lateral edge (AI-L) and acetabular index-sourcil (AI-S), and at five years using AI-L, AI-S, centre-edge angle (CEA), and acetabular depth ratio (ADR). Each hip was classified based on published normative values for normal, borderline (1 to 2 standard deviations (SDs)), or dysplastic (> 2 SDs) based on sex, age, and laterality.Aims
Methods
This study aimed to evaluate rasterstereography of the spine as a diagnostic test for adolescent idiopathic soliosis (AIS), and to compare its results with those obtained using a scoliometer. Adolescents suspected of AIS and scheduled for radiographs were included. Rasterstereographic scoliosis angle (SA), maximal vertebral surface rotation (ROT), and angle of trunk rotation (ATR) with a scoliometer were evaluated. The area under the curve (AUC) from receiver operating characteristic (ROC) plots were used to describe the discriminative ability of the SA, ROT, and ATR for scoliosis, defined as a Cobb angle > 10°. Test characteristics (sensitivity and specificity) were reported for the best threshold identified using the Youden method. AUC of SA, ATR, and ROT were compared using the bootstrap test for two correlated ROC curves method.Aims
Methods
A
Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy.Aims
Methods
The Uppföljningsprogram för cerebral pares (CPUP) Hip Score distinguishes between children with cerebral palsy (CP) at different levels of risk for displacement of the hip. The score was constructed using data from Swedish children with CP, but has not been confirmed in any other population. The aim of this study was to determine the calibration and discriminatory accuracy of this score in children with CP in Scotland. This was a total population-based study of children registered with the Cerebral Palsy Integrated Pathway Scotland. Displacement of the hip was defined as a migration percentage (MP) of > 40%. Inclusion criteria were children in Gross Motor Function Classification System (GMFCS) levels III to V. The calibration slope was estimated and Kaplan-Meier curves produced for five strata of CPUP scores to compare the observed with the predicted risk of displacement of the hip at five years. For discriminatory accuracy, the time-dependent area under the receiver operating characteristic curve (AUC) was estimated. In order to analyze differences in the performance of the score between cohorts, score weights, and subsequently the AUC, were re-estimated using the variables of the original score: the child’s age at the first examination, GMFCS level, head shaft angle, and MP of the worst hip in a logistic regression with imputation of outcomes for those with incomplete follow-up.Aims
Methods
We have previously developed a
The accurate assessment of compartmental involvement in degenerative arthritis of the knee is important when planning operative treatment. Standard
Axial radiographs were obtained under valgus and external rotation stress at 45° of knee flexion with and without contraction of the quadriceps muscle in order to assess the dynamics of patellar subluxation or dislocation. The
After a unicompartmental Oxford knee replacement, a clear lateral
Aims. To assess the long-term effect of distal trochanteric transfer
(DTT) on the clinical and
It is difficult to establish the diagnosis of an injured shoulder if only one
We studied the development of ball-and-socket deformity of the ankle by arthrography and
We compared goniometric assessment of passive ankle movement with
There is no consensus on the benefit of arthroscopically
assisted reduction of the articular surface combined with fixation
using a volar locking plate for the treatment of intra-articular
distal radial fractures. In this study we compared the functional
and
A series of 75 patients who had undergone anterior cervical fusion between 1965 and 1977 were reviewed. The patients were divided into two groups: those in Group A had had the level of fusion indicated by cine
Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal. This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts.Aims
Methods
The medial displacement osteotomy of Chiari has an established place in the management of older children and adults with severe hip dysplasia. The results claimed for the operation are, however, variable. There have also been reports of sciatic nerve lesions. In this study ten cadavers were operated upon. Chiari osteotomy was performed upon five, and five acted as controls. The hemipelvis was removed from each cadaver; each specimen was deep-frozen and sectioned transversely. The distance of the sciatic nerve from the nearest bony point was measured in each section and the results were recorded graphically. A further
We compared the usefulness of
A group of patients were studied 10 years after stopping work in a high-pressure environment.
Impaction bone grafting for the reconstitution
of bone stock in revision hip surgery has been used for nearly 30 years.
Between 1995 and 2001 we used this technique in acetabular reconstruction,
in combination with a cemented component, in 304 hips in 292 patients
revised for aseptic loosening. The only additional supports used
were stainless steel meshes placed against the medial wall or laterally
around the acetabular rim to contain the graft. All Paprosky grades
of defect were included. Clinical and
A
A method is described which provides standardised reproducible
We recorded inter- and intra-observer variations in the classification of ankle fractures by the Lauge Hansen and Weber systems.
Eleven articulated scoliotic spines were examined radiographically and morphometrically. Measurement of the curve on anteroposterior radiographs of the specimens gave a mean Cobb angle of 70 degrees, though true anteroposterior radiographs of the deformity revealed a mean Cobb angle of 99 degrees (41% greater). Lateral radiographs gave the erroneous impression that there was a mean kyphosis of 41 degrees while true lateral projections revealed a mean apical lordosis of 14 degrees. Morphometric measurements confirmed the presence of a lordosis at bony level, the apical vertebral bodies being significantly taller anteriorly (P less than 0.02). There were significant correlations (P less than 0.01) between the true size of the lateral scoliosis, the amount of axial rotation and the size of the apical lordosis. This study illustrates the three-dimensional nature of the deformity in scoliosis and its property of changing in character and magnitude according to the plane of
To assess the effect of improved methods of femoral cementing on the loosening rates in young patients, we reviewed 50 'second-generation' cemented hip arthroplasties in 44 patients aged 50 years or less. The femoral stems were all collared and rectangular in cross-section with rounded corners. The cement was delivered by a gun into a medullary canal occluded distally with a cement plug. A clinical and
A computerised image analyser has been used experimentally to determine its possible usefulness in quantifying bone density. Rats were prepared for this purpose and ash weight/volume readings were obtained on femora which had been radiographed and studied to estimate
We report two new
We investigated a new method of stress
Assessment of bony union after anterior fusion of the lumbar spine has previously relied on the skilled interpretation of plain radiograph. A biplanar
Twenty patients were examined by standard
We have reviewed a series of 94 Chiari pelvic osteotomies carried out from 1966 to 1982. In 83 hips the indication for surgery had been pain, and of these patients 73 (88%) had appreciable relief within one year of operation. The other 11 hips were all in children and were painless; in them the osteotomy had successfully stabilised progressive subluxation of the hip. At review after a mean follow-up of 10 years (range, 2 to 18 years) 68 previously painful hips were reassessed. Although function of the hips had deteriorated slowly with time, four of the seven cases with 18 years' follow-up had good function and only minor symptoms. A detailed analysis of the
We treated 50 patients with fractures of the waist of the scaphoid in a below-elbow plaster cast for up to 13 weeks. Displacement of the fragments was assessed independently by two observers using MRI and radiographs performed within two weeks of injury. The MRI assessments showed that only the measurement of sagittal translation of the fragments and an overall assessment of displacement had satisfactory inter- and intra-observer reproducibility and revealed that nine of the 50 fractures were displaced. Only three of the 49 fractures with adequate follow-up failed to unite, and all were displaced with more than 1 mm of translation in the sagittal plane. If the MRI assessment of displacement of the fracture was used as the measurement of choice, assessment of displacement on the initial scaphoid series of radiographs showed a sensitivity of between 33% and 47% and a positive predictive value of between 27% and 86%. Neither observer was able correctly to identify more than 33% to 47% of the displaced fractures from the plain radiographs. Although the overall assessment of displacement and gapping and translation in the coronal plane on the plain radiographs influenced the rate of union, none of these parameters identified all three fractures which failed to unite. We conclude that the assessment of displacement of scaphoid fractures on MRI can probably be used to assess the likelihood of union although the small number of nonunions limits the power of the study. In contrast, the assessment of displacement on routine
A diastasis between the femoral head and the acetabulum can be achieved for a short while by the application of manual traction on the lower extremity. The intra-articular low-pressure area can be visualised radiographically and is known as a "vacuum phenomenon". The resulting arthrogram clearly outlines the shape, thickness and extent of the cartilage. In the presence of an effusion the diastasis occurs without a vacuum phenomenon. This simple, non-invasive and inoffensive method of traction
The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these measurements and to determine if they should be used clinically. A 10% sample was randomly generated from 3670 consecutive adult
patients who had presented to University Hospitals of Leicester
NHS Trust between 2007 and 2010 with a fracture of the distal radius.
Radiographs of the 367 patients were assessed by two independent
reviewers. Four measurements of displacement of the fracture were recorded
and the inter-observer correlation assessed using the intra-class
correlation coefficient.Aims
Patients and Methods
Threaded acetabular components are widely used in cementless total hip replacement, despite a poor understanding of the nature of the bone-implant interface. We have examined one case in which the threaded titanium ring appeared to be well incorporated with no discernible radiolucency. Microradiography and histology surprisingly showed that the threads were entirely encapsulated in fibrous tissue. This raises doubt about the relevance of plain
We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress
Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only three femoral components had definitely loosened, none were probably loose and 24 were graded as possibly loose. In contrast, the incidence of
We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and
This study aimed to determine the diagnostic performance of radiographic
criteria to detect aseptic acetabular loosening after revision total
hip arthroplasty (THA). Secondary aims were to determine the predictive
values of different thresholds of migration and to determine the
predictive values of radiolucency criteria. Acetabular component migration to re-revision was measured retrospectively
using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements
(Sutherland method) in two groups: Group A, 52 components (48 patients) found
not loose at re-revision and Group B, 42 components (36 patients)
found loose at re-revision between 1980 and 2015. The presence and
extent of radiolucent lines was also assessed.Aims
Patients and Methods
We made a study of 49 total hip arthroplasties at five years, comparing the Charnley hip score, the Nottingham Health Profile (NHP) score and the appearance on serial radiographs. Each of the three investigations was performed by an independent observer with no knowledge of the results of the other two studies. The eight patients with
We took posteroanterior weight-bearing radiographs, both with the joint fully extended and in 30° of flexion, in a consecutive series of 50 knees in 37 patients referred for the primary assessment of pain and/or stiffness. These radiographs were reported ‘blind’ both by an orthopaedic surgeon and a radiologist. Direct measurement of the joint space, together with grading of the severity of erosion according to the Ahlback criteria, was undertaken. Any other abnormality present was also documented. The radiographs of the knees in 30° of flexion consistently showed more advanced erosion in both the medial (p = 0.001) and the lateral (p = 0.0001) tibiofemoral compartments, when compared with those of knees in full extension. The Ahlback classification of 25 joints was altered, in some cases by several grades, by the flexed position of the joint. In every case in which another abnormality was identified on the radiograph in full extension, it was also noted on that of the knee in 30° of flexion. In a further four cases, additional pathology could only be seen in the flexed knee. Every patient was able to complete the radiological examination without difficulty. Our study supports the adoption of a weight-bearing view in 30° of flexion as the standard posteroanterior radiograph for the assessment of tibiofemoral osteoarthritis in patients over 50 years of age.
We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value. Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p <
0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.
In Norway total joint replacement after hip dysplasia
is reported more commonly than in neighbouring countries, implying
a higher prevalence of the condition. We report on the prevalence
of radiological features associated with hip dysplasia in a population
of
2081 19-year-old Norwegians. The radiological measurements used
to define hip dysplasia were Wiberg’s centre-edge (CE) angle at
thresholds of <
20° and <
25°, femoral head extrusion index
<
75%, Sharp’s angle >
45°, an acetabular depth to width ratio
<
250 and the sourcil shape assessed subjectively. The whole
cohort underwent clinical examination of their range of hip movement,
body mass index (BMI), and Beighton hypermobility score, and were
asked to complete the EuroQol (EQ-5D) and Western Ontario and McMaster
Universities Osteoarthritis Index (WOMAC). The prevalence of hip
dysplasia in the cohort varied from 1.7% to 20% depending on the
radiological marker used. A Wiberg’s CE angle <
20° was seen
in 3.3% of the cohort: 4.3% in women and 2.4% in men. We found no
association between subjects with multiple radiological signs indicative
of dysplasia and BMI, Beighton score, EQ-5D or WOMAC. Although there
appears to be a high prevalence of hip dysplasia among 19-year-old
Norwegians, this is dependent on the radiological parameters applied. Cite this article:
We have evaluated the reliability of the measurement of radiological indicators in developmental dysplasia of the hip. Three observers each independently assessed 60 pelvic radiographs from infants aged from 3 to 36 months. Errors from the true value of a single measurement made by a single observer (E1), of the average of two measurements by a single observer (E2), and of the average of two single measurements by two different observers (E3) were established for the acetabular index of Hilgenreiner, for the assessment of superior and lateral femoral displacement and for indicators of pelvic alignment. The errors for the assessment of the acetabular index were E1 ± 5°, E2 ± 5°, and E3 ± 3.5°. There was a significant correlation between the presence of an acetabular notch on the radiograph and an increased error in measurement (p = 0.01). Yamamuro’s measurement of lateral femoral displacement was more reliable than the Hilgenreiner distance. The errors of indicators of pelvic alignment showed a correlation with the age of the infant; the quotient of pelvic rotation was more reliable after seven months of age (p <
0.0001). The errors of the measurement of the symphysis os-ischium angle tended to increase with age and those of the measurement of the index of pelvic tilt decreased with skeletal maturation (p = 0.002).
We have assessed the value of using a simple apparatus, the Carpal Box, in patients with suspected scaphoid fracture, to produce elongated and magnified radiographs of the carpus. The interobserver agreement between 60 observers of standard scaphoid radiographs and longitudinal and transverse Carpal Box radiographs (X-CB) was compared in 11 patients. Three-phase bone scanning was used as a comparative standard. If at least 75% of the observers agreed and the result was confirmed by three-phase bone scanning, the outcome was termed reliable. Scaphoid radiographs and the longitudinal X-CB films were reliable in four patients and the transverse X-CB films in six patients. The bone scan suggested a scaphoid fracture in five of the 11 patients. Agreement in the interpretation of the standard scaphoid radiographs was acceptable in only 36% of patients: in interpretation of transverse Carpal Box radiographs this figure increased to 55%.