Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in
Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during
Aims. Conventional patient-reported surveys, used for patients undergoing
Aims. This study aimed to describe practice variation in the use of
Aims. A significant reduction in wear at five and ten years was previously reported when comparing Durasul highly cross-linked polyethylene with nitrogen-sterilized Sulene polyethylene in
Aims. Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after
Aims. Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients’ pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted
Aims. The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after
Aims. The aim of this study was to compare the early postoperative mortality and morbidity in older patients with a fracture of the femoral neck, between those who underwent
Aims. The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following
Aims. Excessive posterior pelvic tilt (PT) may increase the risk of anterior instability after
Aims. Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after
Aims. Osteoporosis can determine surgical strategy for
Aims. Surgery is often delayed in patients who sustain a hip fracture and are treated with a
Aims. Dual-mobility acetabular components (DMCs) have improved
Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative
Aims. We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods. We retrospectively reviewed 170 patients who underwent 187
Aims.
Aims.
Aims. Spinopelvic mobility plays an important role in functional acetabular component position following
Aims. Lateral femoral cutaneous nerve (LFCN) injury is a potential complication after the direct anterior approach for
Aims. Pelvic incidence (PI) is a position-independent spinopelvic parameter traditionally used by spinal surgeons to determine spinal alignment. Its relevance to the arthroplasty surgeon in assessing patient risk for
Aims. This study aimed to use intraoperative free electromyography to examine how the placement of a retractor at different positions along the anterior acetabular wall may affect the femoral nerve during
Aims. Head-taper corrosion is a cause of failure in
Aims. Patients with spinal pathology who undergo
Aims. Use of the direct anterior approach (DAA) for
Aims. Iliopsoas pathology is a relatively uncommon cause of pain following
Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to
Aims.
Aims. Despite few good-quality studies on the subject,
Aims. Dislocation is the most common indication for further surgery following
Aims. The aim of this study was to report our experience at 3.5 years with outpatient
Aims. The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after
Aims. The direct anterior (DA) approach has been associated with rapid patient recovery after
Aims. Previous research has demonstrated increased early complication rates following
In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a primary total hip arthroplasty (THA) for osteoarthritis (OA). Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1 September 1999 to 31 December 2022 were analyzed. Collared cementless femoral components and cemented components were identified, and the three most commonly used components in each group were analyzed. We identified a total of 11,278 collared cementless components and 47,835 cemented components. Hazard ratios (HRs) from Cox proportional hazards models, adjusting for age and sex, were obtained to compare the revision rates between the groups.Aims
Methods
The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.Aims
Methods
Aims. The complex relationship between acetabular component position and spinopelvic mobility in patients following
Aims. Optimal exposure through the direct anterior approach (DAA) for
Aims. Previous studies have reported an increased risk for postoperative complications in the Medicaid population undergoing
Aims. The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis composite (APC) reconstruction of the proximal femur following primary tumour resection provides more stability than
Aims. Although periarticular injection plays an important role in multimodal pain management following
Aims. A variety of surgical approaches are used for
Aims. Several radiological methods of measuring anteversion of the acetabular component after
Aims. Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and internal fixation (ORIF), or with acute
Aims. Whether patient-reported pain differs among surgical approaches in
Aims. While previously underappreciated, factors related to the spine contribute substantially to the risk of dislocation following
Aims. Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or
Aims. This study reports the mid-term results of