Aims. In patients with a failed radial head arthroplasty (RHA), simple
Aims. The aim of this study was to investigate whether on-demand
We have reviewed our experience of the
Aims. The aim of this study was to evaluate the functional outcome in patients undergoing implant
Aims. Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and
Aims. The purpose of this study was to determine the impact of the
We hypothesised that the
Methods. In this study of patients who underwent internal fixation without
fusion for a burst thoracolumbar or lumbar fracture, we compared
the serial changes in the injured disc height (DH), and the fractured
vertebral body height (VBH) and kyphotic angle between patients
in whom the implants were removed and those in whom they were not. Radiological
parameters such as injured DH, fractured VBH and kyphotic angle
were measured. Functional outcomes were evaluated using the Greenough
low back outcome scale and a VAS scale for pain. Results. Between June 1996 and May 2012, 69 patients were analysed retrospectively;
47 were included in the implant
Our aim was to compare the one-year post-operative
outcomes following retention or
We studied 55 patients who had undergone elective
We have had experience of an 18-month-old boy with a cardiomyopathy who died a few minutes after
Arthrodesis after the
Several authors have reported complications from screw
The primary aim of this study was to define the standard minimum
follow-up required to produce a reliable estimate of the rate of
re-operation after radial head arthroplasty (RHA). The secondary
objective was to define the leading reasons for re-operation. Four electronic databases, between January 2000 and March 2017
were searched. Articles reporting reasons for re-operation (Group
I) and results (Group II) after RHA were included. In Group I, a
meta-analysis was performed to obtain the standard minimum follow-up,
the mean time to re-operation and the reason for failure. In Group
II, the minimum follow-up for each study was compared with the standard
minimum follow-up.Aims
Materials and Methods
Twenty-nine patients with thirty pseudarthroses after
The incidence of refracture following the
We report four patients who sustained secondary fractures of the posterior wall of the tibial shaft during the
Total
Bone weakness leading to refracture is a recognised complication of the
1. A twenty-six-year-old woman was paraplegic because of a benign giant-cell tumour which had destroyed the body of the twelfth thoracic vertebra completely and the bodies of the eleventh thoracic and first lumbar vertebrae partially. The tumour had expanded into both pleural cavities and displaced the aorta forward and to the left. The extent and topography of the tumour were evaluated before operation by angiography. The function of the spinal cord had not been improved significantly by laminectomy. It was therefore decided to attempt extirpation of the tumour by removing all remaining parts of the three vertebrae involved. 2. After the
We used single-photon absorptiometry to assess the forearm bones after the
Most surgeons favour removing forearm plates
in children. There is, however, no long-term data regarding the complications
of retaining a plate. We present a prospective case series of 82
paediatric patients who underwent plating of their forearm fracture
over an eight-year period with a minimum follow-up of two years.
The study institution does not routinely remove forearm plates.
A total of 116 plates were used: 79 one-third tubular plates and 37 dynamic
compression plates (DCP). There were 12 complications: six plates
(7.3%) were removed for pain or stiffness and there were six (7.3%)
implant-related fractures. Overall, survival of the plates was 85%
at 10 years. Cox regression analysis identified radial plates (odds
ratio (OR) 4.4, p = 0.03) and DCP fixation (OR 3.2, p = 0.02) to
be independent risk factors of an implant-related fracture. In contrast
ulnar plates were more likely to cause pain or irritation necessitating
removal (OR 5.6, p = 0.04). The complications associated with retaining a plate are different,
but do not occur more frequently than the complications following
removal of a plate in children.
The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA). A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other.Aims
Methods
The purpose of this study was to compare the
amount of acetabular bone removed during hip resurfacing (HR) and cementless
total hip replacement (THR), after controlling for the diameter
of the patient’s native femoral head. Based on a power analysis,
64 consecutive patients (68 hips) undergoing HR or THR were prospectively
enrolled in the study. The following data were recorded intra-operatively:
the diameter of the native femoral head, the largest reamer used,
the final size of the acetabular component, the size of the prosthetic
femoral head and whether a decision was made to increase the size
of the acetabular component in order to accommodate a larger prosthetic femoral
head. Results were compared using two-sided, independent samples
Student’s
We retrospectively identified 18 consecutive patients with synovial chrondromatosis of the shoulder who had arthroscopic treatment between 1989 and 2004. Of these, 15 were available for review at a mean follow-up of 5.3 years (2.3 to 16.5). There were seven patients with primary synovial chondromatosis, but for the remainder, the condition was a result of secondary causes. The mean Constant score showed that pain and activities of daily living were the most affected categories, being only 57% and 65% of the values of the normal side. Surgery resulted in a significant improvement in the mean Constant score in these domains from 8.9 (4 to 15) to 11.3 (2 to 15) and from 12.9 (5 to 20) to 18.7 (11 to 20), respectively (unpaired We found that arthroscopic debridement of the glenohumeral joint and open debridement and tenodesis of the long head of biceps, when indicated, are safe and effective in relieving symptoms at medium-term review.
Intrapelvic migration of the acetabular component of a total hip replacement, with severe acetabular destruction making reconstruction impossible, is very rare. We present a patient in whom the component was removed using a laparotomy and a transperitoneal approach with subsequent salvage using a saddle prosthesis and a total femoral replacement.
Resurfacing arthroplasty of the hip is being performed more frequently in the United Kingdom. The majority of these patients are younger than 55 years of age, and in this group the key benefits include conservation of femoral bone stock and the potential reduction in the rate of dislocation afforded by the larger resurfacing head. Early aseptic loosening is well recognised in patients younger than 55 years of age, and proponents of resurfacing believe that the improved wear characteristics of the metal-on-metal bearing may improve the long-term survival of this implant. There has been some concern, however, that resurfacing may not be conservative of acetabular bone. We compared a series of 33 consecutive patients who had a hybrid total hip arthroplasty with an uncemented acetabular component and a cemented femoral implant, with 35 patients undergoing a Birmingham hip resurfacing arthroplasty. We compared the diameter of the implanted acetabulum in both groups and, because they were not directly comparable, we corrected for patient size by measuring the diameter of the contralateral femoral head. The data were analysed using unpaired There was a significantly larger acetabulum in the Birmingham arthroplasty group (mean diameter 56.6 mm
Instruments used in surgery which rotate or vibrate at a high frequency can produce potentially contaminated aerosols. Such tools are in use in cemented hip revision arthroplasties. We aimed to measure the extent of the environmental and body contamination caused by an ultrasound device and a high-speed cutter. On a human cadaver we carried out a complete surgical procedure including draping and simulated blood flow contaminated with Environmental contamination was present in an area of 6 x 8 m for both devices. The concentration of contamination was lower for the ultrasound device. Both the ultrasound and the high-speed cutter contaminated all members of the surgical team. The devices tested produced aerosols which covered the whole operating theatre and all personnel present during the procedure. In contaminated and infected patients, infectious agents may be present in these aerosols. We therefore recommend the introduction of effective measures to control infection and thorough disinfection of the operating theatre after such procedures.
The upper three-quarters of the fibula is commonly used as a non-vascularised autograft. Subsequent to this isolated weakness of extensor hallucis longus may occur. We have studied 26 patients in whom the upper and middle thirds of the fibula had been harvested as a graft through Henry’s posterolateral approach. Isolated weakness of extensor hallucis longus was found after operation in ten patients but not in the remainder. EMG and nerve-conduction studies confirmed injury of the nerve to extensor hallucis longus in those with weakness. We dissected 40 cadaver limbs and found that those in which the nerve to extensor hallucis longus ran close to the fibular periosteum were at risk. The injury is mostly incomplete and recovery occurs within four to six months.
We reviewed 17 patients after arthroscopic resection for anterior impingement in the ankle. All had had painful limitation of dorsiflexion which had failed to respond to conservative treatment. Review at an average of 39 months showed very significant improvements in levels of pain, swelling, stiffness, limping and activity. There was a significant improvement in the range of dorsiflexion but not of plantar flexion. One poor result was due to a superficial infection, and two other patients had residual numbness of the foot which persisted for several months.
In immature long bones, radical excision of malignant tumours of the metaphysis may necessitate sacrifice of the adjacent epiphysis. To preserve the adjacent joint while allowing a safe margin of excision, we used physeal distraction before removing the tumour. From July 1984 to August 1992, we operated on 20 patients by this method. After a mean follow-up of 54 months there was no local recurrence in the epiphyseal region. Three patients had developed pulmonary metastases.
Lesions within the articular cartilage layer of synovial joints do not heal spontaneously. Some repair cells may appear, but their failure to become established may be related to problems of adhesion to proteoglycan-rich surfaces. We therefore investigated whether controlled enzymatic degradation of surface proteoglycan molecules to a depth of about 1 μm, using chondroitinase ABC, would improve coverage by repair cells. We created superficial lesions (1.0 × 0.2 × 5 mm) in the articular cartilage of mature rabbit knees and treated the surfaces with 1 U/ml of chondroitinase ABC for four minutes. The defects were studied by histomorphometry and electron microscopy at one, three and six months. At one month, untreated lesions were covered to a mean extent of 28% by repair cells; this was enhanced to a mean of 53% after enzyme treatment. By three months, the mean coverage of both control and chondroitinase-ABC-treated defects had diminished dramatically to 0.2% and 13%, respectively, but at six months both untreated and treated lesions had a similar coverage of about 30%, not significantly different from that achieved in untreated knees at one month. These findings suggest that, with time, chondrocytes near the surface of the defect may compensate for the loss of proteoglycans produced by enzyme treatment, thereby restoring the inhibitory properties of the matrix as regards cell adhesion. This supposition was confirmed by electron microscopy. Our results have an important bearing on attempts made to induce healing responses by transplanting chondrogenic cells or by applying growth factors.
Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant
Aims. The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect. Methods. A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs. Results. Statistically significant improvement from pre- to postoperation was seen in all VAS and ASES scores for each group, but no statistical differences were seen between the postoperative scores according to the differences in the features of the calcific deposits. When residual calcification was observed postoperatively, the mean ASES and VAS (rest) scores improved significantly to 95.0 (SD 5.6) and 0.0 (SD 0.0), respectively (p = 0.006 and p < 0.001), and did not differ from those who had the complete
Aims. Management of displaced paediatric supracondylar elbow fractures remains widely debated and actual practice is unclear. This national trainee collaboration aimed to evaluate surgical and postoperative management of these injuries across the UK. Methods. This study was led by the South West Orthopaedic Research Division (SWORD) and performed by the Supra Man Collaborative. Displaced paediatric supracondylar elbow fractures undergoing surgery between 1 January 2019 and 31 December 2019 were retrospectively identified and their anonymized data were collected via Research Electronic Data Capture (REDCap). Results. A total of 972 patients were identified across 41 hospitals. Mean age at injury was 6.3 years (1 to 15), 504 were male (52%), 583 involved the left side (60%), and 538 were Gartland type 3 fractures (55%). Median time from injury to theatre was 16 hours (interquartile range (IQR) 6.6 to 22), 300 patients (31%) underwent surgery on the day of injury, and 91 (9%) underwent surgery between 10:00 pm and 8:00 am. Overall, 910 patients (94%) had Kirschner (K)-wire) fixation and these were left percutaneous in 869 (95%), while 62 patients (6%) had manipulation under anaesthetic (MUA) and casting. Crossed K-wire configuration was used as fixation in 544 cases (59.5%). Overall, 208 of the fixation cases (61%) performed or supervised by a paediatric orthopaedic consultant underwent lateral-only fixation, whereas 153 (27%) of the fixation cases performed or supervised by a non-paediatric orthopaedic consultant used lateral-only fixation. In total, 129 percutaneous wires (16%) were removed in theatre. Of the 341 percutaneous wire fixations performed or supervised by a paediatric orthopaedic consultant, 11 (3%) underwent wire
Aims. Paediatric fractures are highly prevalent and are most often treated with plaster. The application and