Advertisement for orthosearch.org.uk
Results 1 - 50 of 775
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 597 - 603
1 May 2014
Nomura T Naito M Nakamura Y Ida T Kuroda D Kobayashi T Sakamoto T Seo H

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs. Cite this article: Bone Joint J 2014; 96-B:597–603


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 47 - 50
1 Jan 2010
Konan S Rayan F Haddad FS

The radiological evaluation of the anterolateral femoral head is an essential tool for the assessment of the cam type of femoroacetabular impingement. CT, MRI and frog lateral plain radiographs have all been suggested as imaging options for this type of lesion. The alpha angle is accepted as a reliable indicator of the cam type of impingement and may also be used as an assessment for the successful operative correction of the cam lesion. We studied the alpha angles of 32 consecutive patients with femoroacetabular impingement. The angle measured on frog lateral radiographs using templating tools was compared with that measured on CT scans in order to assess the reliability of the frog lateral view in analysing the alpha angle in cam impingement. A high interobserver reliability was noted for the assessment of the alpha angle on the frog lateral view with an intraclass correlation coefficient of 0.83. The mean alpha angle measured on the frog lateral view was 58.71° (32° to 83.3°) and that by CT was 65.11° (30° to 102°). A poor intraclass correlation coefficient (0.08) was noted between the measurements using the two systems. The frog lateral plain radiograph is not reliable for measuring the alpha angle. Various factors may be responsible for this such as the projection of the radiograph, the positioning of the patient and the quality of the image. CT may be necessary for accurate measurement of the alpha angle


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 147 - 150
1 Jan 1992
Ballock R Mackersie R Abitbol J Cervilla V Resnick D Garfin

Plain radiographs of 67 acute spinal compression fractures in 49 patients were analysed by subjective and objective criteria, using CT scans as the diagnostic standard for the diagnosis of burst fracture. Discriminant analysis correctly predicted the type of fracture in 88% of cases. Burst fractures, however, were almost as frequently misdiagnosed as being wedge compression fractures using this technique, compared with the reading of 25 films from patients without previous information. A quarter of the injuries would have been misdiagnosed had reliance been placed solely on the plain radiographs. CT scans of all patients with acute spinal compression fractures should be considered to decrease this potentially serious diagnostic error


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1501 - 1508
1 Nov 2010
Donell ST Darrah C Nolan JF Wimhurst J Toms A Barker THW Case CP Tucker JK

Metal-on-metal total hip replacement has been targeted at younger patients with anticipated long-term survival, but the effect of the production of metal ions is a concern because of their possible toxicity to cells. We have reviewed the results of the use of the Ultima hybrid metal-on-metal total hip replacement, with a cemented polished tapered femoral component with a 28 mm diameter and a cobalt-chrome (CoCr) modular head, articulating with a 28 mm CoCr acetabular bearing surface secured in a titanium alloy uncemented shell. Between 1997 and 2004, 545 patients with 652 affected hips underwent replacement using this system. Up to 31 January 2008, 90 (13.8%) hips in 82 patients had been revised. Pain was the sole reason for revision in 44 hips (48.9%) of which 35 had normal plain radiographs. Peri-prosthetic fractures occurred in 17 hips (18.9%) with early dislocation in three (3.3%) and late dislocation in 16 (17.8%). Infection was found in nine hips (10.0%). At operation, a range of changes was noted including cavities containing cloudy fluid under pressure, necrotic soft tissues with avulsed tendons and denuded osteonecrotic upper femora. Corrosion was frequently observed on the retrieved cemented part of the femoral component. Typically, the peri-operative findings confirmed those found on pre-operative metal artefact reduction sequence MRI and histological examination showed severe necrosis. Metal artefact reduction sequence MRI proved to be useful when investigating these patients with pain in the absence of adverse plain radiological features


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 153 - 153
1 Jan 2000
WROBLEWSKI BM


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 431 - 435
1 May 1999
Pradhan R

In total hip replacement, orientation of the cup is critical to the stability of the prosthesis. A new method to determine the angle of planar anteversion is described. A simple mathematical formula uses the measurements taken from anteroposterior radiographs to calculate the planar anteversion without reference to tables or charts.

An experimental study in vitro has shown the efficacy of the formula in giving results which are within a clinically acceptable range.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 369 - 375
1 Mar 2017
Ross M Wiemann M Peters SE Benson R Couzens GB

Aims. The aims of this study were: firstly, to investigate the influence of the thickness of cartilage at the sigmoid notch on the inclination of the distal radioulnar joint (DRUJ), and secondly, to compare the sensitivity and specificity of MRI with plain radiographs for the assessment of the inclination of the articular surface of the DRUJ in the coronal plane. . Patients and Methods. Contemporaneous MRI images and radiographs of 100 wrists from 98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male, 53%) with no history of a fracture involving the wrist or surgery to the wrist, were reviewed. The thickness of the cartilage at the sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ were determined. . Results. The assessment using MRI scans and cortical bone correlated well with radiographs, with a kappa value of 0.83. The mean difference between the inclination using the cortex and cartilage on MRI scans was 12°, leading to a change of Tolat type of inclination in 66% of wrists. No reverse oblique (Type 3) inclinations were found when using the cartilage to assess inclination. . Conclusion . These data revealed that when measuring the inclination of the DRUJ using cartilage, reverse oblique inclinations might not exist. The data suggest that performing an ulna shortening osteotomy might be reasonable even in distal radioulnar joints where the plain radiographic appearance suggests an unfavourable reverse oblique inclination in the coronal plane. We recommend using MRI to validate radiographs in those that appear to be reverse oblique (Tolat Type 3), as the true inclination might be different, thereby removing one possible contraindication to ulnar shortening. Cite this article: Bone Joint J 2017;99-B:369–75


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1533 - 1537
1 Nov 2013
Farshad M Aichmair A Hughes AP Herzog RJ Farshad-Amacker NA

The purpose of this study was to devise a simple but reliable radiological method of identifying a lumbosacral transitional vertebra (LSTV) with a solid bony bridge on sagittal MRI, which could then be applied to a lateral radiograph.

The vertical mid-vertebral angle (VMVA) and the vertical anterior vertebral angle (VAVA) of the three most caudal segments of the lumbar spine were measured on MRI and/or on a lateral radiograph in 92 patients with a LSTV and 94 controls, and the differences per segment (Diff-VMVA and Diff-VAVA) were calculated. The Diff-VMVA of the two most caudal vertebrae was significantly higher in the control group (25° (sd 8) than in patients with a LSTV (type 2a+b: 16° (sd 9), type 3a+b: -9° (sd 10), type 4: -5° (sd 7); p < 0.001). A Diff-VMVA of ≤ +10° identified a LSTV with a solid bony bridge (type 3+4) with a sensitivity of 100% and a specificity of 89% on MRI and a sensitivity of 94% and a specificity of 74% on a lateral radiograph. A sensitivity of 100% could be achieved with a cut-off value of 28° for the Diff-VAVA, but with a lower specificity (76%) on MRI than with Diff-VMVA.

Using this simple method (Diff-VMVA ≤ +10°), solid bony bridging of the posterior elements of a LSTV, and therefore the first adjacent mobile segment, can be easily identified without the need for additional imaging.

Cite this article: Bone Joint J 2013;95-B:1533–7.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 568 - 574
1 May 2023
Kobayashi H Ito N Nakai Y Katoh H Okajima K Zhang L Tsuda Y Tanaka S

Aims. The aim of this study was to report the patterns of symptoms and insufficiency fractures in patients with tumour-induced osteomalacia (TIO) to allow the early diagnosis of this rare condition. Methods. The study included 33 patients with TIO who were treated between January 2000 and June 2022. The causative tumour was detected in all patients. We investigated the symptoms and evaluated the radiological patterns of insufficiency fractures of the rib, spine, and limbs. Results. The mean age of the patients was 57 years (24 to 87), and the mean duration of pain from onset to time of presentation was 3.9 years (0.75 to 23). The primary symptoms were low back pain (ten patients), chest wall pain (eight patients), and hip pain (eight patients). There were symptoms at more sites at the time of presentation compared with that at the time of the onset of symptoms. Bone scans showed the uptake of tracer in the rib (100%), thoracic and lumbar vertebrae (83%), proximal femur (62%), distal femur (66%), and proximal tibia (72%). Plain radiographs or MRI scans identified femoral neck fractures in 14 patients, subchondral insufficiency fractures of the femoral head and knee in ten and six patients, respectively, distal femoral fractures in nine patients, and proximal tibial fractures in 12 patients. Thoracic or lumbar vertebral fractures were identified in 23 of 29 patients (79.3%) when using any imaging study, and a biconcave deformity was the most common type of fracture. Conclusion. Insufficiency fractures in patients with TIO caused spinal pain, chest wall pain, and periarticular pain in the lower limbs. Vertebral fractures tended to be biconcave deformities, and periarticular fractures of the hips and knees included subchondral insufficiency fractures and epiphyseal or metaphyseal fractures. In patients with a tumour, the presence of one or more of these symptoms and an insufficiency fracture should suggest the diagnosis of TIO. Cite this article: Bone Joint J 2023;105-B(5):568–574


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1578 - 1584
1 Dec 2019
Batailler C Weidner J Wyatt M Pfluger D Beck M

Aims. A borderline dysplastic hip can behave as either stable or unstable and this makes surgical decision making challenging. While an unstable hip may be best treated by acetabular reorientation, stable hips can be treated arthroscopically. Several imaging parameters can help to identify the appropriate treatment, including the Femoro-Epiphyseal Acetabular Roof (FEAR) index, measured on plain radiographs. The aim of this study was to assess the reliability and the sensitivity of FEAR index on MRI compared with its radiological measurement. Patients and Methods. The technique of measuring the FEAR index on MRI was defined and its reliability validated. A retrospective study assessed three groups of 20 patients: an unstable group of ‘borderline dysplastic hips’ with lateral centre edge angle (LCEA) less than 25° treated successfully by periacetabular osteotomy; a stable group of ‘borderline dysplastic hips’ with LCEA less than 25° treated successfully by impingement surgery; and an asymptomatic control group with LCEA between 25° and 35°. The following measurements were performed on both standardized radiographs and on MRI: LCEA, acetabular index, femoral anteversion, and FEAR index. Results. The FEAR index showed excellent intraobserver and interobserver reliability on both MRI and radiographs. The FEAR index was more reliable on radiographs than on MRI. The FEAR index on MRI was lower in the stable borderline group (mean -4.2° (. sd. 9.1°)) compared with the unstable borderline group (mean 7.9° (. sd. 6.8°)). With a FEAR index cut-off value of 2°, 90% of patients were correctly identified as stable or unstable using the radiological FEAR index, compared with 82.5% using the FEAR index on MRI. The FEAR index was a better predictor of instability on plain radiographs than on MRI. Conclusion. The FEAR index measured on MRI is less reliable and less sensitive than the FEAR index measured on radiographs. The cut-off value of 2° for radiological FEAR index predicted hip stability with 90% probability. Cite this article: Bone Joint J 2019;101-B:1578–1584


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 496 - 503
1 May 2023
Mills ES Talehakimi A Urness M Wang JC Piple AS Chung BC Tezuka T Heckmann ND

Aims. It has been well documented in the arthroplasty literature that lumbar degenerative disc disease (DDD) contributes to abnormal spinopelvic motion. However, the relationship between the severity or pattern of hip osteoarthritis (OA) as measured on an anteroposterior (AP) pelvic view and spinopelvic biomechanics has not been well investigated. Therefore, the aim of the study is to examine the association between the severity and pattern of hip OA and spinopelvic motion. Methods. A retrospective chart review was conducted to identify patients undergoing primary total hip arthroplasty (THA). Plain AP pelvic radiographs were reviewed to document the morphological characteristic of osteoarthritic hips. Lateral spine-pelvis-hip sitting and standing plain radiographs were used to measure sacral slope (SS) and pelvic femoral angle (PFA) in each position. Lumbar disc spaces were measured to determine the presence of DDD. The difference between sitting and standing SS and PFA were calculated to quantify spinopelvic motion (ΔSS) and hip motion (ΔPFA), respectively. Univariate analysis and Pearson correlation were used to identify morphological hip characteristics associated with changes in spinopelvic motion. Results. In total, 139 patients were included. Increased spinopelvic motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.05). Loss of hip motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.001). A decreased joint space was associated with a decreased ΔPFA (p = 0.040). The presence of disc space narrowing, disc space narrowing > two levels, and disc narrowing involving the L5–S1 segment were associated with decreased spinopelvic motion (all p < 0.05). Conclusion. Preoperative hip OA as assessed on an AP pelvic radiograph predicts spinopelvic motion. These data suggest that specific hip osteoarthritic morphological characteristics listed above alter spinopelvic motion to a greater extent than others. Cite this article: Bone Joint J 2023;105-B(5):496–503


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1396 - 1401
1 Oct 2013
Gabbe BJ Esser M Bucknill A Russ MK Hofstee D Cameron PA Handley C deSteiger RN

We describe the routine imaging practices of Level 1 trauma centres for patients with severe pelvic ring fractures, and the interobserver reliability of the classification systems of these fractures using plain radiographs and three-dimensional (3D) CT reconstructions. Clinical and imaging data for 187 adult patients (139 men and 48 women, mean age 43 years (15 to 101)) with a severe pelvic ring fracture managed at two Level 1 trauma centres between July 2007 and June 2010 were extracted. Three experienced orthopaedic surgeons classified the plain radiographs and 3D CT reconstruction images of 100 patients using the Tile/AO and Young–Burgess systems. Reliability was compared using kappa statistics. A total of 115 patients (62%) had plain radiographs as well as two-dimensional (2D) CT and 3D CT reconstructions, 52 patients (28%) had plain films only, 12 (6.4%) had 2D and 3D CT reconstructions images only, and eight patients (4.3%) had no available images. The plain radiograph was limited to an anteroposterior pelvic view. Patients without imaging, or only plain films, were more severely injured. A total of 72 patients (39%) were imaged with a pelvic binder in situ. Interobserver reliability for the Tile/AO (Kappa 0.10 to 0.17) and Young–Burgess (Kappa 0.09 to 0.21) was low, and insufficient for clinical and research purposes. Severe pelvic ring fractures are difficult to classify due to their complexity, the increasing use of early treatment such as with pelvic binders, and the absence of imaging altogether in important patient sub-groups, such as those who die early of their injuries. Cite this article: Bone Joint J 2013;95-B:1396–1401


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 766 - 771
1 Jun 2009
Brunner A Honigmann P Treumann T Babst R

We evaluated the impact of stereo-visualisation of three-dimensional volume-rendering CT datasets on the inter- and intraobserver reliability assessed by kappa values on the AO/OTA and Neer classifications in the assessment of proximal humeral fractures. Four independent observers classified 40 fractures according to the AO/OTA and Neer classifications using plain radiographs, two-dimensional CT scans and with stereo-visualised three-dimensional volume-rendering reconstructions. Both classification systems showed moderate interobserver reliability with plain radiographs and two-dimensional CT scans. Three-dimensional volume-rendered CT scans improved the interobserver reliability of both systems to good. Intraobserver reliability was moderate for both classifications when assessed by plain radiographs. Stereo visualisation of three-dimensional volume rendering improved intraobserver reliability to good for the AO/OTA method and to excellent for the Neer classification. These data support our opinion that stereo visualisation of three-dimensional volume-rendering datasets is of value when analysing and classifying complex fractures of the proximal humerus


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims. Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children. Methods. In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs. Results. We categorized the new bone formation into three stages: stage I (early lengthening), in which there was no obvious callus formation on radiographs and ultrasound; stage II (lengthening), in which radiographs showed low-density callus formation with uneven distribution and three sub-stages could be identified on ultrasound: in Ia punctate callus was visible; in IIb there was linear callus formation which was not yet connected and in IIc there was continuous linear callus. In stage III (healing), the bone ends had united, the periosteum was intact, and the callus had disappeared, as confirmed on radiographs, indicating healed bone. A progressive increase in the number of vertical vessels was noted in the early stages, peaking during stages IIb and IIc, followed by a gradual decline (p < 0.001). Delayed healing involved patients with a prolonged stage IIa or those who regressed to stage IIa from stages IIb or IIc during lengthening. Conclusion. We found that the formation of new bone in paediatric patients undergoing limb lengthening could be reliably evaluated using ultrasound when combined with the radiological findings. This combination enabled an improved assessment of the prognosis, and adjustments to the lengthening protocol. While SMI offered additional insights into angiogenesis within the new bone, its role primarily contributed to the understanding of the microvascular environment rather than directly informing adjustments of treatment. Cite this article: Bone Joint J 2024;106-B(7):751–758


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 739 - 745
1 Apr 2021
Mehta JS Hodgson K Yiping L Kho JSB Thimmaiah R Topiwala U Sawlani V Botchu R

Aims. To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Methods. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)). Results. There were more ionizing radiation-based imaging events and higher radiation dose exposures in the surgical group than in the non-surgical group (p < 0.001). The difference in effective dose for children between the surgical and non-surgical groups was statistically significant, the surgical group being significantly higher (p < 0.001). This led to a higher estimated risk of cancer induction for the surgical group (1:222 surgical vs 1:1,418 non-surgical). However, the dose difference for adults was not statistically different between the surgical and non-surgical groups. In all cases the effective dose received by all cohorts was significantly higher than that from exposure to natural background radiation. Conclusion. The treatment of spinal deformity is radiation-heavy. The dose exposure is several times higher when surgical treatment is undertaken. Clinicians should be aware of this and review their practices in order to reduce the radiation dose where possible. Cite this article: Bone Joint J 2021;103-B(4):1–7


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 257 - 264
1 Feb 2022
Tahir M Mehta D Sandhu C Jones M Gardner A Mehta JS

Aims. The aim of this study was to compare the clinical and radiological outcomes of patients with early-onset scoliosis (EOS), who had undergone spinal fusion after distraction-based spinal growth modulation using either traditional growing rods (TGRs) or magnetically controlled growing rods (MCGRs). Methods. We undertook a retrospective review of skeletally mature patients who had undergone fusion for an EOS, which had been previously treated using either TGRs or MCGRs. Measured outcomes included sequential coronal T1 to S1 height and major curve (Cobb) angle on plain radiographs and any complications requiring unplanned surgery before final fusion. Results. We reviewed 43 patients (63% female) with a mean age of 6.4 years (SD 2.6) at the index procedure, and 12.2 years (SD 2.2) at final fusion. Their mean follow-up was 8.1 years (SD 3.4). A total of 16 patients were treated with MCGRs and 27 with TGRs. The mean number of distractions was 7.5 in the MCGR group and ten in the TGR group (p = 0.471). The mean interval between distractions was 3.4 months in the MCGR group and 8.6 months in the TGR group (p < 0.001). The mean Cobb angle had improved by 25.1° in the MCGR group and 23.2° in TGR group (p = 0.664) at final follow-up. The mean coronal T1 to S1 height had increased by 16% in the MCGR group and 32.9% in TGR group (p = 0.001), although the mean T1 to S1 height achieved at final follow-up was similar in both. Unplanned operations were needed in 43.8% of the MCGR group and 51.2% of TGR group (p = 0.422). Conclusion. In this retrospective, single-centre review, there were no significant differences in major curve correction or gain in spinal height at fusion. Although the number of planned procedures were fewer in patients with MCGRs, the rates of implant-related complications needing unplanned revision surgery were similar in the two groups. Cite this article: Bone Joint J 2022;104-B(2):257–264


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1064 - 1068
1 Aug 2009
Sankey RA Turner J Lee J Healy J Gibbons CER

An MR scan was performed on all patients who presented to our hospital with a clinical diagnosis of a fracture of the proximal femur, but who had no abnormality on plain radiographs. This was a prospective study of 102 consecutive patients over a ten-year period. There were 98 patients who fulfilled our inclusion criteria, of whom 75 were scanned within 48 hours of admission, with an overall mean time between admission and scanning of 2.4 days (0 to 10). A total of 81 patients (83%) had abnormalities detected on MRI; 23 (23%) required operative management. The use of MRI led to the early diagnosis and treatment of occult hip pathology. We recommend that incomplete intertrochanteric fractures are managed non-operatively with protected weight-bearing. The study illustrates the high incidence of fractures which are not apparent on plain radiographs, and shows that MRI is useful when diagnosing other pathology such as malignancy, which may not be apparent on plain films


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 500 - 506
1 Mar 2021
Leonard HJ Ohly NE

Aims. The purpose of this study was to compare the clinical, radiological, and patient-reported outcome measures (PROMs) in the first 100 consecutive patients undergoing total hip arthroplasty (THA) via a direct superior approach (DSA) with a matched group of patients undergoing THA by the same surgeon, using a posterolateral approach (PLA). Methods. This was a retrospective single surgeon study comparing the first 100 consecutive DSA THA patients with a matched group of patients using a standard PLA. Case notes were examined for patient demographics, length of hospital stay, operating time, intra- and postoperative complications, pain score, satisfaction score, and Oxford Hip Score (OHS). Leg length discrepancy and component positioning were measured from postoperative plain radiographs. Results. The DSA patients had a shorter length of hospital stay (mean 2.09 days (SD 1.20) DSA vs 2.74 days (SD 1.17) PLA; p < 0.001) and shorter time to discharge from the inpatient physiotherapy teams (mean 1.44 days (SD 1.17) DSA vs 1.93 days (SD 0.96) PLA; p < 0.001). There were no differences in operating time (p = 0.505), pain levels up to postoperative day 1 (p = 0.106 to p =0.242), OHS (p = 0.594 to p = 0.815), satisfaction levels (p = 0.066 to p = 0.299), stem alignment (p = 0.240), acetabular component inclination (p < 0.001) and anteversion (p < 0.001), or leg length discrepancy (p = 0.134). Conclusion. While the DSA appears safe and was not associated with a significant difference in PROMs, radiological findings, or intraoperative or postoperative complications, a randomized controlled trial with functional outcomes in the postoperative phase is needed to evaluate this surgical approach formally. Cite this article: Bone Joint J 2021;103-B(3):500–506


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 670 - 672
1 Jul 1998
Flinkkilä T Nikkola-Sihto A Kaarela O Päakkö E Raatikainen T

Interobserver reliability of the AO system of classification of fractures of the distal radius was assessed using plain radiographs and CT. Five observers classified 30 Colles’-type fractures using only plain radiographs; two months later they were reclassified using CT in addition. Interobserver reliability was poor in both series when detailed classification was used. By reducing the categories to five, interobserver reliability was slightly improved, but was still poor. When only two AO types were used, the reliability was moderate using plain radiographs and good to excellent with the addition of CT. The use of CT as well as plain radiographs brings interobserver reliability to a good level in assessment of the presence or absence of articular involvement, but is otherwise of minor value in improving the interobserver reliability of the AO system of classification of fractures of the distal radius


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 907 - 914
1 Jul 2009
Koivu H Kohonen I Sipola E Alanen K Vahlberg T Tiusanen H

Between 2002 and 2008, 130 consecutive ankles were replaced with an hydroxyapatite (HA) and titanium-HA-coated Ankle Evolutive System total ankle prosthesis. Plain radiographs were analysed by two independent observers. Osteolytic lesions were classified by their size and location, with cavities > 10 mm in diameter considered to be ‘marked’. CT scanning was undertaken in all patients with marked osteolysis seen on the plain radiographs. Osteolytic lesions were seen on the plain films in 48 (37%) and marked lesions in 27 (21%) ankles. The risk for osteolysis was found to be 3.1 (95% confidence interval 1.6 to 5.9) times higher with implants with Ti-HA porous coating. Care should be taken with ankle arthroplasty until more is known about the reasons for these severe osteolyses


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims. Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning. Methods. A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts. Results. A total of 59 surgeons completed the survey. For all surgeons, the use of the PSP significantly increased agreement with the experts in glenoid classification (x. 2. = 8.54; p = 0.014) and surgical planning (x. 2. = 37.91; p < 0.001). The additional information provided by the PSP also showed a significantly higher impact on surgical decision-making for surgeons who undertake fewer than ten shoulder arthroplasties annually (p = 0.017). Conclusions. The information provided by PSP has the greatest impact on the surgical decision-making of low volume surgeons (those who perform fewer than ten shoulder arthroplasties annually), and PSP brings all surgeons in to closer agreement with the recommendations of experts for glenoid classification and surgical planning. Cite this article: Bone Joint J 2020;102-B(3):365–370


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 510 - 515
1 Apr 2007
Watts AC Morris A Robinson CM

Fractures of the distal humeral articular surface which do not involve the medial and lateral columns are often more extensive than is apparent from plain radiographs. This retrospective study describes the epidemiology of this injury using modern classification systems and compares pre-operative radiography with operative findings. The study group included 79 patients with a mean age of 47 years (13 to 91). The annual incidence was 1.5 per 100 000 population, and was highest in women over the age of 60. The majority of the fractures (59; 75%) were sustained in falls from standing height. Young males tended to sustain more high-energy injuries with more complex fracture patterns. In 24% of cases (19) there was a concomitant radial head fracture. Classification from plain radiographs often underestimates the true extent of the injury and computed tomography may be of benefit in pre-operative planning, especially in those over 60 years of age


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1042 - 1049
1 Sep 2019
Murphy MP Killen CJ Ralles SJ Brown NM Hopkinson WJ Wu K

Aims. Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT 3D reconstruction, and are cumbersome to use. These methods also partly rely on the identification of obscured radiological borders of the component. We propose two novel methods, the Area and Orthogonal methods, which have been designed to maximize use of readily identifiable points while maintaining the same trigonometric principles. Patients and Methods. A retrospective study of plain radiographs was conducted on 160 hips of 141 patients who had undergone primary THA. We compared the reliability and accuracy of the Area and Orthogonal methods with two of the current leading methods: those of Widmer and Lewinnek, respectively. Results. The 160 anteroposterior pelvis films revealed that the proposed Area method was statistically different from those described by Widmer and Lewinnek (p < 0.001 and p = 0.004, respectively). They gave the highest inter- and intraobserver reliability (0.992 and 0.998, respectively), and took less time (27.50 seconds (. sd. 3.19); p < 0.001) to complete. In addition, 21 available CT 3D reconstructions revealed the Area method achieved the highest Pearson’s correlation coefficient (r = 0.956; p < 0.001) and least statistical difference (p = 0.704) from CT with a mean within 1° of CT-3D reconstruction between ranges of 1° to 30° of measured radiological anteversion. Conclusion. Our results support the proposed Area method to be the most reliable, accurate, and speedy. They did not support any statistical superiority of the proposed Orthogonal method to that of the Widmer or Lewinnek method. Cite this article: Bone Joint J 2019;101-B:1042–1049


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 113 - 122
1 Jan 2021
Kayani B Tahmassebi J Ayuob A Konan S Oussedik S Haddad FS

Aims. The primary aim of this study was to compare the postoperative systemic inflammatory response in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic-arm assisted total knee arthroplasty (robotic TKA). Secondary aims were to compare the macroscopic soft tissue injury, femoral and tibial bone trauma, localized thermal response, and the accuracy of component positioning between the two treatment groups. Methods. This prospective randomized controlled trial included 30 patients with osteoarthritis of the knee undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localized knee temperature were collected preoperatively and postoperatively at six hours, day 1, day 2, day 7, and day 28 following TKA. Blinded observers used the Macroscopic Soft Tissue Injury (MASTI) classification system to grade intraoperative periarticular soft tissue injury and bone trauma. Plain radiographs were used to assess the accuracy of achieving the planned postioning of the components in both groups. Results. Patients undergoing conventional TKA and robotic TKA had comparable changes in the postoperative systemic inflammatory and localized thermal response at six hours, day 1, day 2, and day 28 after surgery. Robotic TKA had significantly reduced levels of interleukin-6 (p < 0.001), tumour necrosis factor-α (p = 0.021), ESR (p = 0.001), CRP (p = 0.004), lactate dehydrogenase (p = 0.007), and creatine kinase (p = 0.004) at day 7 after surgery compared with conventional TKA. Robotic TKA was associated with significantly improved preservation of the periarticular soft tissue envelope (p < 0.001), and reduced femoral (p = 0.012) and tibial (p = 0.023) bone trauma compared with conventional TKA. Robotic TKA significantly improved the accuracy of achieving the planned limb alignment (p < 0.001), femoral component positioning (p < 0.001), and tibial component positioning (p < 0.001) compared with conventional TKA. Conclusion. Robotic TKA was associated with a transient reduction in the early (day 7) postoperative inflammatory response but there was no difference in the immediate (< 48 hours) or late (day 28) postoperative systemic inflammatory response compared with conventional TKA. Robotic TKA was associated with decreased iatrogenic periarticular soft tissue injury, reduced femoral and tibial bone trauma, and improved accuracy of component positioning compared with conventional TKA. Cite this article: Bone Joint J 2021;103-B(1):113–122


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1292 - 1300
1 Jul 2021
Märtens N Heinze M Awiszus F Bertrand J Lohmann CH Berth A

Aims. The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. Methods. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted. Results. The ROM (p < 0.001), CS (p < 0.001), and DASH score (p < 0.001) showed significant improvements after shoulder arthroplasty for both implants. There were no differences between the groups treated with stemmed or stemless shoulder prosthesis with respect to the mean CS (79.2 (35 to 118) vs 74.4 (31 to 99); p = 0.519) and DASH scores (11.4 (8 to 29) vs 13.2 (7 to 23); p = 0.210). The ten-year unadjusted cumulative survival rate was 95.3% for the stemmed anatomical shoulder prosthesis and 91.5% for the stemless shoulder prosthesis and did not differ between the treatment groups (p = 0.251). The radiological evaluation of the humeral components in both groups did not show loosening of the humeral implant. The main reason for revision for each type of arthroplasties were complications related to the glenoid. Conclusion. The use of anatomical stemless shoulder prosthesis yielded good and reliable results and did not differ from anatomical stemmed shoulder prosthesis over a mean period of ten years. The differences in periprosthetic humeral bone adaptations between both implants have no clinical impact during the follow-up. Cite this article: Bone Joint J 2021;103-B(7):1292–1300


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 331 - 337
1 Mar 2018
Inui H Nobuhara K

Aims. We report the clinical results of glenoid osteotomy in patients with atraumatic posteroinferior instability associated with glenoid dysplasia. Patients and Methods. The study reports results in 211 patients (249 shoulders) with atraumatic posteroinferior instability. The patients comprised 63 men and 148 women with a mean age of 20 years. The posteroinferior glenoid surface was elevated by osteotomy at the scapular neck. A body spica was applied to maintain the arm perpendicular to the glenoid for two weeks postoperatively. Clinical results were evaluated using the Rowe score and Japan Shoulder Society Shoulder Instability Score (JSS-SIS); bone union, osteoarthrosis, and articular congruity were examined on plain radiographs. Results. The Rowe score improved from 36 to 88 points, and the JSS-SIS improved from 47 to 81 points. All shoulders exhibited union without progression of osteoarthritis except one shoulder, which showed osteoarthritic change due to a previous surgery before the glenoid osteotomy. All but three shoulders showed improvement in joint congruency. Eight patients developed disordered scapulohumeral rhythm during arm elevation, and 12 patients required additional open stabilization for anterior instability. Conclusion. Good results can be expected from glenoid osteotomy in patients with atraumatic posteroinferior instability associated with glenoid dysplasia. Cite this article: Bone Joint J 2018;100-B:331–7


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 256 - 261
1 Feb 2018
Kim W Lee JS Chung HW

Aims. Adjuvant treatment after intralesional curettage for atypical cartilaginous tumours (ACTs) of long bones is widely accepted for extending surgical margins. However, evaluating the isolated effect of adjuvant treatment is difficult, and it is unclear whether not using such adjuvants provides poor oncological outcomes. Hence, we analyzed whether intralesional curettage without cryosurgery or chemical adjuvants provides poor oncological outcomes in patients with an ACT. Patients and Methods. A total of 24 patients (nine men, 15 women) (mean age 45 years; 18 to 62) were treated for ACTs of long bones and followed up for a median of 66 months (interquartile range 50 to 84). All patients were treated with extensive manual curettage and limited burring. Bone cement and grafts were used to fill bone defects in 16 and eight patients, respectively. No chemical adjuvants or cryosurgery were used. Results. No local recurrence was detectable on plain radiographs and MRI or CT images. At the last follow-up, there were no distant metastases or disease-specific deaths. No procedure-related complications or postoperative fractures developed. Conclusion. Intralesional curettage without cryosurgery or chemical adjuvants may provide excellent oncological outcomes for patients with ACTs of long bones, without the risk of complications related to adjuvant use. Our investigation suggests thorough curettage alone is a reasonable treatment option for ACT. However, we acknowledge the limited size of our investigation warrants a multicentre collaborative study to confirm our findings. Cite this article: Bone Joint J 2018;100-B:256–61


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims. Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods. A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results. In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (. sd. 0.16) and 0.00 mm (. sd. 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (. sd. 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (. sd. 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion. This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1275 - 1279
1 Oct 2018
Fader RR Tao MA Gaudiani MA Turk R Nwachukwu BU Esposito CI Ranawat AS

Aims. The purpose of this study was to evaluate spinopelvic mechanics from standing and sitting positions in subjects with and without femoroacetabular impingement (FAI). We hypothesize that FAI patients will experience less flexion at the lumbar spine and more flexion at the hip whilst changing from standing to sitting positions than subjects without FAI. This increase in hip flexion may contribute to symptomatology in FAI. Patients and Methods. Male subjects were prospectively enrolled to the study (n = 20). Mean age was 31 years old (22 to 41). All underwent clinical examination, plain radiographs, and dynamic imaging using EOS. Subjects were categorized into three groups: non-FAI (no radiographic or clinical FAI or pain), asymptomatic FAI (radiographic and clinical FAI but no pain), and symptomatic FAI (patients with both pain and radiographic FAI). FAI was defined as internal rotation less than 15° and alpha angle greater than 60°. Subjects underwent standing and sitting radiographs in order to measure spine and femoroacetabular flexion. Results. Compared with non-FAI controls, symptomatic patients with FAI had less flexion at the spine (mean 22°, . sd. 12°, vs mean 35°, . sd. 8°; p = 0.04) and more at the hip (mean 72°, . sd. 6°, vs mean 62°, . sd. 8°; p = 0.047). Subjects with asymptomatic FAI had more spine flexion and similar hip flexion when compared to symptomatic FAI patients. Both FAI groups also sat with more anterior pelvic tilt than control patients. There were no differences in standing alignment among groups. Conclusion. Symptomatic patients with FAI require more flexion at the hip to achieve sitting position due to their inability to compensate through the lumbar spine. With limited spine flexion, FAI patients sit with more anterior pelvic tilt, which may lead to impingement between the acetabulum and proximal femur. Differences in spinopelvic mechanics between FAI and non-FAI patients may contribute to the progression of FAI symptoms. Cite this article: Bone Joint J 2018;100-B:1275–9


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1100 - 1105
1 Aug 2018
Howard EL Shepherd KL Cribb G Cool P

Aims. The aim of this study was to validate the Mirels score in predicting pathological fractures in metastatic disease of the lower limb. Patients and Methods. A total of 62 patients with confirmed metastatic disease met the inclusion criteria. Of the 62 patients, 32 were female and 30 were male. The mean age of patients was 65 years (35 to 89). The primary malignancy originated from the breast in 27 (44%) patients, prostate in 15 (24%) patients, kidney in seven (11%), and lung in four (6%) of patients. One patient (2%) had metastatic carcinoma from the lacrimal gland, two patients (3%) had multiple myeloma, one patient (2%) had lymphoma of bone, and five patients (8%) had metastatic carcinoma of unknown primary. Plain radiographs at the time of initial presentation were scored using Mirels system by the four authors. The radiographic components of the score (anatomical site, size, and radiographic appearance) were scored two weeks apart. Inter- and intraobserver reliability were calculated with Fleiss’ kappa test. Bland-Altman plots were created to compare the variances of the individual components of the score and the total Mirels score. Results. Kappa values for the interobserver variability of the components of the Mirels score were k = 0.554 (95% CI 0.483 to 0.626) for site, k = 0.342 (95% CI 0.285 to 0.400) for size, k = 0.443 (95% CI 0.387 to 0.499) for radiographic appearance, and k = 0.294 (95% CI 0.258 to 0.331)for the total score. Kappa values for the intra-observer reliability were k = 0.608 (95% CI 0.506 to 0.710) for site, k = 0.579 (95% CI 0.487 to 0.670) for size, k = 0.614 (95% CI 0.522 to 0.703) for radiographic appearance, and k = 0.323 (95% CI 0.266 to 0.379) for total score. Conclusion. Our study showed fair to moderate agreement between authors when using the Mirels score, and moderate to substantial agreement when authors rescored radiographs. The Mirels score is subjective and lacks reproducibility in predicting the risk of pathological fracture. Cite this article: Bone Joint J 2018;100-B:1100–5


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives. The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction. Materials and Methods. This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (. sd. 5.2) vs 67.5 years (. sd. 5.8) (p = 0.25); body mass index (27.4 kg/m. 2. (. sd. 2.1) vs 26.9 kg/m. 2. (. sd. 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs. Results. The correlation coefficient was 0.92 (95% confidence interval (CI) 0.88 to 0.95) for intraobserver agreement and 0.88 (95% CI 0.82 to 0.94) for interobserver agreement in all study outcomes. Robotic THA was associated with improved accuracy in restoring the native horizontal (p < 0.001) and vertical (p < 0.001) centres of rotation, and improved preservation of the patient’s native combined offset (p < 0.001) compared with conventional THA. Robotic THA improved accuracy in positioning of the acetabular component within the combined safe zones of inclination and anteversion described by Lewinnek et al (p = 0.02) and Callanan et al (p = 0.01) compared with conventional THA. There was no difference between the two treatment groups in achieving the planned leg-length correction (p = 0.10). Conclusion. Robotic-arm assisted THA was associated with improved accuracy in restoring the native centre of rotation, better preservation of the combined offset, and more precise acetabular component positioning within the safe zones of inclination and anteversion compared with conventional manual THA


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 461 - 467
1 Apr 2018
Wagener J Schweizer C Zwicky L Horn Lang T Hintermann B

Aims. Arthroscopically controlled fracture reduction in combination with percutaneous screw fixation may be an alternative approach to open surgery to treat talar neck fractures. The purpose of this study was thus to present preliminary results on arthroscopically reduced talar neck fractures. Patients and Methods. A total of seven consecutive patients (four women and three men, mean age 39 years (19 to 61)) underwent attempted surgical treatment of a closed Hawkins type II talar neck fracture using arthroscopically assisted reduction and percutaneous screw fixation. Functional and radiological outcome were assessed using plain radiographs, as well as weight-bearing and non-weight-bearing CT scans as tolerated. Patient satisfaction and pain sensation were also recorded. Results. Primary reduction was obtained arthroscopically in all but one patient, for whom an interposed fracture fragment had to be removed through a small arthrotomy to permit anatomical reduction. The quality of arthroscopic reduction and restoration of the talar geometry was excellent in the remaining six patients. There were no signs of talar avascular necrosis or subtalar degeneration in any of the patients. In the whole series, the functional outcome was excellent in five patients but restricted ankle movement was observed in two patients. All patients had a reduction in subtalar movement. At final follow-up, all patients were satisfied and all but one patient were pain free. Conclusion. Arthroscopically assisted reduction and fixation of talar neck fractures was found to be a feasible treatment option and allowed early functional rehabilitation. Cite this article: Bone Joint J 2018;100-B:461–7


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 777 - 780
1 Sep 1998
Robinson AHN Bird N Screaton N Wraight EP Meggitt BF

We describe a new technique, known as coregistration imaging, which superimposes . 99m. Tc isotope bone scans on to plain radiographs. We used the technique selectively in cases in which the nuclear medicine physician, who reported the isotope scan, had difficulty in localising the anatomical site of the abnormality. In the forefoot, coregistration of isotope scans did not help to localise pathology; the scan alone gave sufficient detail. In 17 patients with pain in the hind- and midfoot, isotope scanning identified eight sites of abnormality in those with normal radiographs. In those with more than one abnormality on plain radiographs the isotope scan eliminated 12 sites of suspicion. Coregistration of the images significantly increased the certainty of localisation of disease (p < 0.001). We recommend the selective use of coregistration scanning as a useful technique for investigating patients with pain in the foot and ankle


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 44 - 50
1 Jan 2017
Salo PP Honkanen PB Ivanova I Reito A Pajamäki J Eskelinen A

Aims. We evaluated the short-term functional outcome and prevalence of bearing-specific generation of audible noise in 301 patients (336 hips) operated on with fourth generation (Delta) medium diameter head, ceramic-on-ceramic (CoC) total hip arthroplasties (THAs). Patients and Methods. There were 191 female (63%) and 110 male patients (37%) with a mean age of 61 years (29 to 78) and mean follow-up of 2.1 years (1.3 to 3.4). Patients completed three questionnaires: Oxford Hip Score (OHS), Research and Development 36-item health survey (RAND-36) and a noise-specific symptom questionnaire. Plain radiographs were also analysed. A total of three hips (0.9%) were revised. . Results. There were 52 patients (54 hips, 17%) who reported noise, and in 25 (48%) of them the noise was frequently heard. In the multiple regression analysis, the only independent risk factor for noise was a specific THA brand, with a threefold increased risk (95% confidence intervals 1.39 to 6.45, p = 0.005) of noise compared with the reference THA brand. Patients with noisy hips had lower median OHS (43 versus 46.5, p = 0.002) and their physical functioning (p = 0.021) subscale in RAND-36 was reduced. Conclusion. Noise was surprisingly common in this population. Cite this article: Bone Joint J 2017;99-B:44–50


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 562 - 566
1 Jul 1997
Vohra R Kang HS Dogra S Saggar RR Sharma R

Tuberculous osteomyelitis which does not involve a joint is uncommon and may fail to be diagnosed by an orthopaedic surgeon. We treated 28 lesions of tuberculous osteomyelitis in 25 patients between 1988 and 1995. The duration of symptoms was from two to 39 months, and most of our patients had been treated initially with non-steroidal anti-inflammatory drugs which failed to provide relief. Bone pain which does not promptly respond to analgesic medication is often due to infection or neoplasia. In the early stages, when plain radiographs are normal, MRI or CT may help to localise lesions. On plain radiographs, more advanced lesions may mimic chronic pyogenic osteomyelitis, Brodie’s abscess, tumours or granulomatous lesions. Biopsy is mandatory to confirm the diagnosis, and antituberculous drugs are the mainstay of treatment. When operative findings at biopsy have the features of skeletal tuberculosis curettage of the affected bone may promote earlier healing


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims. Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types. It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated. Patients and Methods. Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients. . Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings. Results. Excellent inter-method reliability, inter-observer and test-retest reliability were seen. The system did not correlate with the Constant score, but correlated well with its pain component. . Take home message: Our system of classification is a helpful guide to the degree of glenoid bone loss when embarking on revision shoulder arthroplasty. Cite this article: Bone Joint J 2016;98-B:374–80


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 705 - 713
1 Jul 2004
Bhat M McCarthy M Davis TRC Oni JA Dawson S

We treated 50 patients with fractures of the waist of the scaphoid in a below-elbow plaster cast for up to 13 weeks. Displacement of the fragments was assessed independently by two observers using MRI and radiographs performed within two weeks of injury. The MRI assessments showed that only the measurement of sagittal translation of the fragments and an overall assessment of displacement had satisfactory inter- and intra-observer reproducibility and revealed that nine of the 50 fractures were displaced. Only three of the 49 fractures with adequate follow-up failed to unite, and all were displaced with more than 1 mm of translation in the sagittal plane. If the MRI assessment of displacement of the fracture was used as the measurement of choice, assessment of displacement on the initial scaphoid series of radiographs showed a sensitivity of between 33% and 47% and a positive predictive value of between 27% and 86%. Neither observer was able correctly to identify more than 33% to 47% of the displaced fractures from the plain radiographs. Although the overall assessment of displacement and gapping and translation in the coronal plane on the plain radiographs influenced the rate of union, none of these parameters identified all three fractures which failed to unite. We conclude that the assessment of displacement of scaphoid fractures on MRI can probably be used to assess the likelihood of union although the small number of nonunions limits the power of the study. In contrast, the assessment of displacement on routine radiography is inaccurate and of less value in predicting union


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 959 - 963
1 Nov 1997
Matta JM Siebenrock KA

We have studied prospectively the effect of indomethacin on the development of heterotopic ossification (HO) after the internal fixation of acetabular fractures. After operation 107 patients randomly received either a six-week course of indomethacin or no treatment against HO. Plain radiographs of 101 patients at a mean of 7.9 months after surgery showed HO in 47.4% of the 57 patients who received indomethacin and in 56.8% of the 44 who did not. This difference was not statistically significant. Heterotopic ossification of Brooker class II or more was seen in four patients (7%) with prophylaxis and in one without (p = 0.51). Measurements of the volume of HO on 3-D CT reconstructions showed a median value of 1.5 cm. 3. in patients with indomethacin and 4.0 cm. 3. in those without (p = 0.28). When only the 57 patients in whom the operation was carried out through either a Kocher-Langenbeck or an extended iliofemoral approach were included the indomethacin group showed a median volume of 1.7 cm. 3. compared with 3.6 cm. 3. On plain radiographs Brooker class II or above was seen in 9.4% of the patients receiving indomethacin and in 4.8% of those who did not. Indomethacin was therefore not effective in preventing ectopic bone formation after surgery for acetabular fractures. There was a significant association of male gender with volume of HO using a non-parametric analysis of variance


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 145 - 151
1 Feb 2012
Henderson RA Lachiewicz PF

Persistent groin pain after seemingly successful total hip replacement (THR) appears to have become more common. Recent studies have indicated a high incidence after metal-on-polyethylene and metal-on-metal conventional THR and it has been documented in up to 18% of patients after metal-on-metal resurfacing. There are many causes, including acetabular loosening, stress fracture, and iliopsoas tendonitis and impingement. The evaluation of this problem requires a careful history and examination, plain radiographs and an algorithmic approach to special diagnostic imaging and tests. Non-operative treatment is not usually successful. Specific operative treatment depending on the cause of the pain usually involves revision of the acetabular component, iliopsoas tenotomy or other procedures, and is usually successful. Here, an appropriate algorithm is described


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1148 - 1150
1 Aug 2012
Nakamura Y Ohishi H Kishiya M Toh S

Although good to excellent short-term results of arthroscopic partial limbectomy of the hip have been reported, there is little information on the long-term outcome of the procedure. We report a case with a 16-year follow-up. A 34-year old woman presented with a three-month history of severe pain and limitation of movement of the hip. Plain radiographs and arthrography showed no abnormality. MRI showed an effusion and a deformity of the anterosuperior part of the labrum. This was confirmed as an inverted labral tear that was debrided arthroscopically. At 16 years post-operatively, she remained symptom-free. Plain radiographs showed no abnormality and MRI suggested that the sealing effect of the scar tissue prevented articular damage and degeneration


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 560 - 564
1 Apr 2010
Miller AN Prasarn ML Lorich DG Helfet DL

We have examined the accuracy of reduction and the functional outcomes in elderly patients with surgically treated acetabular fractures, based on assessment of plain radiographs and CT scans. There were 45 patients with such a fracture with a mean age of 67 years (59 to 82) at the time of surgery. All patients completed SF-36 questionnaires to determine the functional outcome at a mean follow-up of 72.4 months (24 to 188). All had radiographs and a CT scan within one week of surgery. The reduction was categorised as ‘anatomical’, ‘imperfect’, or ‘poor’. Radiographs classified 26 patients (58%) as anatomical,13 (29%) as imperfect and six (13%) as poor. The maximum displacement on CT showed none as anatomical, 23 (51%) as imperfect and 22 (49%) as poor, but this was not always at the weight-bearing dome. SF-36 scores showed functional outcomes comparable with those of the general elderly population, with no correlation with the radiological reduction. Perfect anatomical reduction is not necessary to attain a good functional outcome in acetabular fractures in the elderly


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1634 - 1639
1 Dec 2015
Faschingbauer M Renner L Waldstein W Boettner F

We studied whether the presence of lateral osteophytes on plain radiographs was a predictor for the quality of cartilage in the lateral compartment of patients with varus osteoarthritic of the knee (Kellgren and Lawrence grade 2 to 3). The baseline MRIs of 344 patients from the Osteoarthritis Initiative (OAI) who had varus osteoarthritis (OA) of the knee on hip-knee-ankle radiographs were reviewed. Patients were categorised using the Osteoarthritis Research Society International (OARSI) osteophyte grading system into 174 patients with grade 0 (no osteophytes), 128 grade 1 (mild osteophytes), 28 grade 2 (moderate osteophytes) and 14 grade 3 (severe osteophytes) in the lateral compartment (tibia). All patients had Kellgren and Lawrence grade 2 or 3 arthritis of the medial compartment. The thickness and volume of the lateral cartilage and the percentage of full-thickness cartilage defects in the lateral compartment was analysed. There was no difference in the cartilage thickness or cartilage volume between knees with osteophyte grades 0 to 3. The percentage of full-thickness cartilage defects on the tibial side increased from < 2% for grade 0 and 1 to 10% for grade 3. The lateral compartment cartilage volume and thickness is not influenced by the presence of lateral compartment osteophytes in patients with varus OA of the knee. Large lateral compartment osteophytes (grade 3) increase the likelihood of full-thickness cartilage defects in the lateral compartment. Cite this article: Bone Joint J 2015;97-B:1634–9


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1205 - 1209
1 Sep 2008
Beeres FJP Rhemrev SJ den Hollander P Kingma LM Meylaerts SAG le Cessie S Bartlema KA Hamming JF Hogervorst M

We evaluated 100 consecutive patients with a suspected scaphoid fracture but without evidence of a fracture on plain radiographs using MRI within 24 hours of injury, and bone scintigraphy three to five days after injury. The reference standard for a true radiologically-occult scaphoid fracture was either a diagnosis of fracture on both MRI and bone scintigraphy, or, in the case of discrepancy, clinical and/or radiological evidence of a fracture. MRI revealed 16 scaphoid and 24 other fractures. Bone scintigraphy showed 28 scaphoid and 40 other fractures. According to the reference standard there were 20 scaphoid fractures. MRI was falsely negative for scaphoid fracture in four patients and bone scintigraphy falsely positive in eight. MRI had a sensitivity of 80% and a specificity of 100%. Bone scintigraphy had a sensitivity of 100% and a specificity of 90%. This study did not confirm that early, short-sequence MRI was superior to bone scintigraphy for the diagnosis of a suspected scaphoid fracture. Bone scintigraphy remains a highly sensitive and reasonably specific investigation for the diagnosis of an occult scaphoid fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1203 - 1208
1 Sep 2010
Brunner A Hamers AT Fitze M Herzog RF

The β-angle is a radiological tool for measuring the distance between the pathological head-neck junction and the acetabular rim with the hip in 90° of flexion in patients with femoroacetabular impingement. Initially it was measured using an open-chamber MRI. We have developed a technique to measure this angle on plain radiographs. Correlation analysis was undertaken to determine the relationship between the range of movement and the β-angle in 50 patients with femoroacetabular impingement and 50 asymptomatic control subjects. Inter- and intra-observer reliability of the β-angle was also evaluated. Patients with femoroacetabular impingement had a significantly smaller (p < 0.001) mean β-angle (15.6°, 95% confidence interval (CI) 13.3 to 17.7) compared with the asymptomatic group (38.7°, 95% CI 36.5 to 41.0). Correlation between internal rotation and the β-angle was high in the impingement group and moderate in the asymptomatic group. The β-angle had excellent inter- and intra-observer reliability in both groups. Our findings suggest that the measurement of the β-angle on plain radiography may represent a valid, reproducible and cost-effective alternative to open MRI in the assessment of the pathological bony anatomy in patients with cam, pincer and mixed femoroacetabular impingement


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 952 - 956
1 Jul 2008
Haddad F Chemali R Maalouf G

Dysplasia epiphysealis hemimelica of the left proximal femur was diagnosed in an eight-month-old girl. At the age of 18 months, radiographs of the hip and MRI showed overgrowth and loss of containment of the femoral head. She underwent resection of the superior portion of the head and neck of the femur at the age of 2.5 years. Six months later further radiographs and an MR scan show that the mass has increased in size and that hip containment has been lost. Further plain radiographs have shown that the left knee, ankle and spine were involved. To the authors’ knowledge, this is the first report of dysplasia epiphysealis hemimelica involving both the lower limb and the spine. A review of the literature is presented


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1381 - 1388
1 Oct 2017
Wong YW Samartzis D Cheung KMC Luk K

Aims. To address the natural history of severe post-tuberculous (TB) kyphosis, with focus upon the long-term neurological outcome, occurrence of restrictive lung disease, and the effect on life expectancy. . Patients and Methods. This is a retrospective clinical review of prospectively collected imaging data based at a single institute. A total of 24 patients of Southern Chinese origin who presented with spinal TB with a mean of 113° of kyphosis (65° to 159°) who fulfilled inclusion criteria were reviewed. Plain radiographs were used to assess the degree of spinal deformity. Myelography, CT and MRI were used when available to assess the integrity of the spinal cord and canal. Patient demographics, age of onset of spinal TB and interventions, types of surgical procedure, intra- and post-operative complications, and neurological status were assessed. . Results. All except one of the 24 patients were treated with anti-TB chemotherapy when they were first diagnosed with spinal TB. They subsequently received surgery either for neurological deterioration, or deformity correction in later life. The mean follow-up was 34 years (11 to 59) since these surgical interventions. Some 16 patients (66.7%) suffered from late neurological deterioration at a mean of 26 years (8 to 49) after the initial drug treatment. The causes of neurological deterioration were healed disease in nine patients (56.2%), re-activation in six patients (37.5%) and adjacent level spinal stenosis in one patient (6.3%). The result of surgery was worse in healed disease. Eight patients without neurological deterioration received surgery to correct the kyphosis. The mean correction ranged from 97° to 72°. Three patients who were clinically quiescent with no neurological deterioration were found to have active TB of the spine. Solid fusion was achieved in all cases and no patient suffered from neurological deterioration after 42 years of follow-up. On final follow-up, six patients were noted to have deceased (age range: 47 years to 75 years). Conclusion. Our study presents one of the longest assessments of spinal TB with severe kyphosis. Severe post-TB kyphosis may lead to significant health problems many years following the initial drug treatment. Early surgical correction of the kyphosis, solid fusion and regular surveillance may avoid late complications. Paraplegia, restrictive lung disease and early onset kyphosis might relate to early death. Clinically quiescent disease does not mean cure. . Cite this article: Bone Joint J 2017;99-B:1381–8


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1253 - 1255
1 Sep 2005
Alam A Willett K Ostlere S

Incomplete intertrochanteric fractures do not extend across to the medial femoral cortex and are stable, without rotational deformity or shortening of the lower limb. The aim of our study was to establish whether they can be successfully managed conservatively. A total of 68 patients over a five-year period presented with a suspected fracture of the femoral neck and underwent an MRI scan for further assessment. From these, we retrospectively reviewed eight patients with normal plain radiographs but with an incomplete, intertrochanteric fracture on MRI scan. Five were managed conservatively and three operatively. The mean length of hospital stay was 16 days for the conservatively-treated group and 15 days for those who underwent surgery; this was not statistically significant (p > 0.5) and all patients were mobilised on discharge. Although five patients were readmitted at a mean of 3.2 years after discharge, none had progressed to a complete fracture. We believe that patients with incomplete intertrochanteric fractures should be considered for conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 32 - 36
1 Jan 2012
Nho J Lee Y Kim HJ Ha Y Suh Y Koo K

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 629 - 633
1 May 2011
Hirschmann MT Konala P Amsler F Iranpour F Friederich NF Cobb JP

We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1610 - 1617
1 Dec 2014
Lainiala O Eskelinen A Elo P Puolakka T Korhonen J Moilanen T

We conducted a retrospective study to assess the prevalence of adverse reactions to metal debris (ARMD) in patients operated on at our institution with metal-on-metal (MoM) total hip replacements with 36 mm heads using a Pinnacle acetabular shell. A total of 326 patients (150 males, 175 hips; 176 females, 203 hips) with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5 years (0.1 to 10.8) participating in our in-depth modern MoM follow-up programme were included in the study, which involved recording whole blood cobalt and chromium ion measurements, Oxford hip scores (OHS) and plain radiographs of the hip and targeted cross-sectional imaging. Elevated blood metal ion levels (> 5 parts per billion) were seen in 32 (16.1%) of the 199 patients who underwent unilateral replacement. At 23 months after the start of our modern MoM follow-up programme, 29 new cases of ARMD had been revealed. Hence, the nine-year survival of this cohort declined from 96% (95% CI 95 to 98) with the old surveillance routine to 86% (95% CI 82 to 90) following the new protocol. Although ARMD may not be as common in 36 mm MoM THRs as in those with larger heads, these results support the Medicines and Healthcare Products Regulatory Agency guidelines on regular reviews and further investigations, and emphasise the need for specific a follow-up programme for patients with MoM THRs. Cite this article: Bone Joint J 2014; 96-B:1610–17