Advertisement for orthosearch.org.uk
Results 1 - 50 of 71
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1595 - 1597
1 Dec 2012
Panesar SS Shaerf DA Mann BS Malik AK

We summarise and highlight the safety concerns within the field of trauma and orthopaedic surgery with particular emphasis placed on current controversies and reforms within the United Kingdom National Health Service.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 960 - 969
1 Aug 2019
Odgaard A Laursen MB Gromov K Troelsen A Kristensen PW Schrøder H Madsen F Overgaard S

Aims

The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check.

Materials and Methods

Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 807 - 810
1 Jul 2020
Oussedik S Zagra L Shin GY D’Apolito R Haddad FS

The transition from shutdown of elective orthopaedic services to the resumption of pre-COVID-19 activity presents many challenges. These include concerns about patient safety, staff safety, and the viability of health economies. Careful planning is necessary to allow patients to benefit from orthopaedic care in a safe and sustainable manner. Cite this article: Bone Joint J 2020;102-B(7):807–810


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 74 - 76
1 Nov 2013
Kamath AF McAuliffe CL Gutsche JT Kosseim LM Hume EL Baldwin KD Kornfield Z Israelite CL

Patient safety is a critical issue in elective total joint replacement surgery. Identifying risk factors that might predict complications and intensive care unit (ICU) admission proves instrumental in reducing morbidity and mortality. The institution’s experience with risk stratification and pre-operative ICU triage has resulted in a reduction in unplanned ICU admissions and post-operative complications after total hip replacement. The application of the prediction tools to total knee replacement has proven less robust so far. This work also reviews areas for future research in patient safety and cost containment. . Cite this article: Bone Joint J 2013;95-B, Supple A:74–6


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 922 - 928
1 Aug 2019
Garner A van Arkel RJ Cobb J

Aims. There has been a recent resurgence in interest in combined partial knee arthroplasty (PKA) as an alternative to total knee arthroplasty (TKA). The varied terminology used to describe these procedures leads to confusion and ambiguity in communication between surgeons, allied health professionals, and patients. A standardized classification system is required for patient safety, accurate clinical record-keeping, clear communication, correct coding for appropriate remuneration, and joint registry data collection. Materials and Methods. An advanced PubMed search was conducted, using medical subject headings (MeSH) to identify terms and abbreviations used to describe knee arthroplasty procedures. The search related to TKA, unicompartmental (UKA), patellofemoral (PFA), and combined PKA procedures. Surveys were conducted of orthopaedic surgeons, trainees, and biomechanical engineers, who were asked which of the descriptive terms and abbreviations identified from the literature search they found most intuitive and appropriate to describe each procedure. The results were used to determine a popular consensus. Results. Survey participants preferred “bi-unicondylar arthroplasty” (Bi-UKA) to describe ipsilateral medial and lateral unicompartmental arthroplasty; “medial bi-compartmental arthroplasty” (BCA-M) to describe ipsilateral medial unicompartmental arthroplasty with patellofemoral arthroplasty; “lateral bi-compartmental arthroplasty” (BCA-L) to describe ipsilateral lateral unicompartmental arthroplasty with patellofemoral arthroplasty; and tri-compartmental arthroplasty (TCA) to describe ipsilateral patellofemoral and medial and lateral unicompartmental arthroplasties. “Combined partial knee arthroplasty” (CPKA) was the favoured umbrella term. Conclusion. We recommend bi-unicondylar arthroplasty (Bi-UKA), medial bicompartmental arthroplasty (BCA-M), lateral bicompartmental arthroplasty (BCA-L), and tricompartmental arthroplasty (TCA) as the preferred terms to classify CPKA procedures. Cite this article: Bone Joint J 2019;101-B:922–928


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 303 - 306
1 Apr 2024
Staats K Kayani B Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 884 - 886
1 Sep 2024
Brown R Bendall S Aronow M Ramasamy A


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1461 - 1468
1 Dec 2024
Hamoodi Z Shapiro J Sayers A Whitehouse MR Watts AC

Aims

The aim of this audit was to assess and improve the completeness and accuracy of the National Joint Registry (NJR) dataset for arthroplasty of the elbow.

Methods

It was performed in two phases. In Phase 1, the completeness was assessed by comparing the NJR elbow dataset with the NHS England Hospital Episode Statistics (HES) data between April 2012 and April 2020. In order to assess the accuracy of the data, the components of each arthroplasty recorded in the NJR were compared to the type of arthroplasty which was recorded. In Phase 2, a national collaborative audit was undertaken to evaluate the reasons for unmatched data, add missing arthroplasties, and evaluate the reasons for the recording of inaccurate arthroplasties and correct them.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 220 - 220
1 Feb 2023
Bowditch M Eastwood DM


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 887 - 891
1 Sep 2024
Whyte W Thomas AM

The critical relationship between airborne microbiological contamination in an operating theatre and surgical site infection (SSI) is well known. The aim of this annotation is to explain the scientific basis of using settle plates to audit the quality of air, and to provide information about the practicalities of using them for the purposes of clinical audit. The microbiological quality of the air in most guidance is defined by volumetric sampling, but this method is difficult for surgical departments to use on a routine basis. Settle plate sampling, which mimics the mechanism of deposition of airborne microbes onto open wounds and sterile instruments, is a good alternative method of assessing the quality of the air. Current practice is not to sample the air in an operating theatre during surgery, but to rely on testing the engineering systems which deliver the clean air. This is, however, not good practice and microbiological testing should be carried out routinely during operations as part of clinical audit.

Cite this article: Bone Joint J 2024;106-B(9):887–891.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1039 - 1043
1 Oct 2024
Luo TD Kayani B Magan A Haddad FS

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team’s overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise.

Cite this article: Bone Joint J 2024;106-B(10):1039–1043.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 843 - 849
1 Aug 2023
Grandhi TSP Fontalis A Raj RD Kim WJ Giebaly DE Haddad FS

Telehealth has the potential to change the way we approach patient care. From virtual consenting to reducing carbon emissions, costs, and waiting times, it is a powerful tool in our clinical armamentarium. There is mounting evidence that remote diagnostic evaluation and decision-making have reached an acceptable level of accuracy and can safely be adopted in orthopaedic surgery. Furthermore, patients’ and surgeons’ satisfaction with virtual appointments are comparable to in-person consultations. Challenges to the widespread use of telehealth should, however, be acknowledged and include the cost of installation, training, maintenance, and accessibility. It is also vital that clinicians are conscious of the medicolegal and ethical considerations surrounding the medium and adhere strictly to the relevant data protection legislation and storage framework. It remains to be seen how organizations harness the full spectrum of the technology to facilitate effective patient care.

Cite this article: Bone Joint J 2023;105-B(8):843–849.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 764 - 774
1 Aug 2024
Rivera RJ Karasavvidis T Pagan C Haffner R Ast MP Vigdorchik JM Debbi EM

Aims

Conventional patient-reported surveys, used for patients undergoing total hip arthroplasty (THA), are limited by subjectivity and recall bias. Objective functional evaluation, such as gait analysis, to delineate a patient’s functional capacity and customize surgical interventions, may address these shortcomings. This systematic review endeavours to investigate the application of objective functional assessments in appraising individuals undergoing THA.

Methods

The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied. Eligible studies of THA patients that conducted at least one type of objective functional assessment both pre- and postoperatively were identified through Embase, Medline/PubMed, and Cochrane Central database-searching from inception to 15 September 2023. The assessments included were subgrouped for analysis: gait analysis, motion analysis, wearables, and strength tests.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1206 - 1215
1 Nov 2023
Ladegaard TH Sørensen MS Petersen MM

Aims

We first sought to compare survival for patients treated surgically for solitary and multiple metastases in the appendicular skeleton, and second, to explore the role of complete and incomplete resection (R0 and R1/R2) in patients with a solitary bony metastasis in the appendicular skeleton.

Methods

We conducted a retrospective study on a population-based cohort of all adult patients treated surgically for bony metastases of the appendicular skeleton between January 2014 and December 2019. We excluded patients in whom the status of bone metastases and resection margin was unknown. Patients were followed until the end of the study or to their death. We had no loss to follow-up. We used Kaplan-Meier analysis (with log-rank test) to evaluate patient survival. We identified 506 operations in 459 patients. A total of 120 operations (in 116 patients) were for solitary metastases and 386 (in 345 patients) for multiple metastases. Of the 120 operations, 70 (in 69 patients) had no/an unknown status of visceral metastases (solitary group) and 50 (in 49 patients) had visceral metastases. In the solitary group, 45 operations (in 44 patients) were R0 (resections for cure or complete remission) and 25 (in 25 patients) were R1/R2 (resections leaving microscopic or macroscopic tumour, respectively). The most common types of cancer in the solitary group were kidney (n = 27), lung (n = 25), and breast (n = 20).


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims

Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes.

Methods

A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1292 - 1303
1 Dec 2022
Polisetty TS Jain S Pang M Karnuta JM Vigdorchik JM Nawabi DH Wyles CC Ramkumar PN

Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered.

Cite this article: Bone Joint J 2022;104-B(12):1292–1303.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 708 - 713
1 Jun 2017
Rushton PRP Siddique I Crawford R Birch N Gibson MJ Hutton MJ

The MAGnetic Expansion Control (MAGEC) system is used increasingly in the management of early-onset scoliosis. Good results have been published, but there have been recent reports identifying implant failures that may be associated with significant metallosis surrounding the implants. This article aims to present the current knowledge regarding the performance of this implant, and the potential implications and strategies that may be employed to identify and limit any problems. We urge surgeons to apply caution to patient and construct selection; engage in prospective patient registration using a spine registry; ensure close clinical monitoring until growth has ceased; and send all explanted MAGEC rods for independent analysis. The MAGEC system may be a good instrumentation system for the treatment of early-onset scoliosis. However, it is innovative and like all new technology, especially when deployed in a paediatric population, robust systems to assess long-term outcome are required to ensure that patient safety is maintained. Cite this article: Bone Joint J 2017;99-B:708–13


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 434 - 441
1 Apr 2015
Shabani F Farrier AJ Krishnaiyan R Hunt C Uzoigwe CE Venkatesan M

Drug therapy forms an integral part of the management of many orthopaedic conditions. However, many medicines can produce serious adverse reactions if prescribed inappropriately, either alone or in combination with other drugs. Often these hazards are not appreciated. In response to this, the European Union recently issued legislation regarding safety measures which member states must adopt to minimise the risk of errors of medication. . In March 2014 the Medicines and Healthcare products Regulatory Agency and NHS England released a Patient Safety Alert initiative focussed on errors of medication. There have been similar initiatives in the United States under the auspices of The National Coordinating Council for Medication Error and The Joint Commission on the Accreditation of Healthcare Organizations. These initiatives have highlighted the importance of informing and educating clinicians. Here, we discuss common drug interactions and contra-indications in orthopaedic practice. This is germane to safe and effective clinical care. Cite this article: Bone Joint J 2015;97-B:434–41


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 680 - 686
1 Jun 2022
Robinson JR Bruce D Davies H Porteous AJ Murray JRD Howells NR

Aims

The best surgical strategy for the management of displaced bucket-handle (BH) meniscal tears in an anterior cruciate ligament (ACL)-deficient knee is unclear. Combining meniscal repair with ACL reconstruction (ACLR) is thought to improve meniscal healing rates; however, patients with displaced BH meniscal tears may lack extension. This leads some to advocate staged surgery to avoid postoperative stiffness and loss of range of motion (ROM) following ACLR.

Methods

We reviewed the data for a consecutive series of 88 patients (mean age 27.1 years (15 to 49); 65 male (74%) and 23 female (26%)) who underwent single-stage repair of a displaced BH meniscal tear (67 medial (76%) and 21 lateral (24%)) with concomitant hamstring autograft ACLR. The patient-reported outcome measures (PROMs) EuroQol visual analogue scale (EQ-VAS), EuroQol five-dimension health questionnaire (EQ-5D), Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee score (IKDC), and Tegner score were recorded at final follow-up. A Kaplan-Meier survival analysis was performed to estimate meniscal repair survivorship. Analyses were performed with different cut-offs for meniscal and ACL injury-to-surgery time (within three weeks, three to ten weeks, and more than ten weeks).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1274 - 1280
1 Oct 2009
Robinson PM Muir LT

Procedures performed at the incorrect anatomical site are commonly perceived as being relatively rare. However, they can be a devastating event for patients and doctors. Evidence from the United Kingdom and North America suggests that wrong-site, wrong-procedure and wrong-patient events occur more commonly than we think. Furthermore, their incidence may be increasing as NHS Trusts increase the volume and complexity of procedures undertaken in order to cope with increasing demands on the system. In previous studies from North America orthopaedic surgery has been found to be the worst-offending specialty. In this paper we review the existing literature on wrong-site surgery and analyse data from the National Patient Safety Agency and NHS Litigation Authority on 292 cases of wrong-site surgery in England and Wales. Orthopaedic surgery accounted for 87 (29.8%) of these cases. In the year 2006 to 2007, the rate of wrong-site surgery in England and Wales was highest in orthopaedic surgery, in which the estimated rate was 1:105 712 cases


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 359 - 367
1 Mar 2022
Deere K Matharu GS Ben-Shlomo Y Wilkinson JM Blom AW Sayers A Whitehouse MR

Aims

A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database.

Methods

Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 441 - 445
1 Apr 2012
Chou DTS Achan P Ramachandran M

The World Health Organization (WHO) launched the first Global Patient Safety Challenge in 2005 and introduced the ‘5 moments of hand hygiene’ in 2009 in an attempt to reduce the burden of health care associated infections. Many NHS trusts in England adopted this model of hand hygiene, which prompts health care workers to clean their hands at five distinct stages of caring for the patient. Our review analyses the scientific foundation for the five moments of hand hygiene and explores the evidence, as referenced by WHO, to support these recommendations. We found no strong scientific support for this regime of hand hygiene as a means of reducing health care associated infections. Consensus-based guidelines based on weak scientific foundations should be assessed carefully to prevent shifting the clinical focus from more important issues and to direct limited resources more effectively. We recommend caution in the universal adoption of the WHO ‘5 moments of hand hygiene’ by orthopaedic surgeons and other health care workers and emphasise the need for evidence-based principles when adopting hospital guidelines aimed at promoting excellence in clinical practice


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 851 - 854
1 Jul 2009
Timperley AJ Whitehouse SL

Recently the National Patient Safety Agency in the United Kingdom published a report entitled “Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur”. A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 127 - 133
1 Jan 2022
Viberg B Pedersen AB Kjærsgaard A Lauritsen J Overgaard S

Aims

The aim of this study was to assess the association of mortality and reoperation when comparing cemented and uncemented hemiarthroplasty (HA) in hip fracture patients aged over 65 years.

Methods

This was a population-based cohort study on hip fracture patients using prospectively gathered data from several national registries in Denmark from 2004 to 2015 with up to five years follow-up. The primary outcome was mortality and the secondary outcome was reoperation. Hazard ratios (HRs) for mortality and subdistributional hazard ratios (sHRs) for reoperations are shown with 95% confidence intervals (CIs).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1405 - 1410
1 Oct 2011
Costa ML Griffin XL Pendleton N Pearson M Parsons N

Concerns have been reported to the United Kingdom National Patient Safety Agency, warning that cementing the femoral component during hip replacement surgery for fracture of the proximal femur may increase peri-operative mortality. . The National Hip Fracture Database collects demographic and outcome data about patients with a fracture of the proximal femur from over 100 participating hospitals in the United Kingdom. We conducted a mixed effects logistic regression analysis of this dataset to determine whether peri-operative mortality was increased in patients who had undergone either hemiarthroplasty or total hip replacement using a cemented femoral component. A total of 16 496 patients from 129 hospitals were included in the analysis, which showed a small but significant adjusted survival benefit associated with cementing (odds ratio 0.83, 95% confidence interval 0.72 to 0.96). Other statistically significant variables in predicting death at discharge, listed in order of magnitude of effect, were gender, American Society of Anesthesiologists grade, age, walking accompanied outdoors and arthroplasty. Interaction terms between cementing and these other variables were sequentially added to, but did not improve, the model. . This study has not shown an increase in peri-operative mortality as a result of cementing the femoral component in patients requiring hip replacement following fracture of the proximal femur


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics. Cite this article: Bone Joint J 2015; 97-B:292–9


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 185 - 190
1 Jun 2021
Kildow BJ Patel SP Otero JE Fehring KA Curtin BM Springer BD Fehring TK

Aims

Debridement, antibiotics, and implant retention (DAIR) remains one option for the treatment of acute periprosthetic joint infection (PJI) despite imperfect success rates. Intraosseous (IO) administration of vancomycin results in significantly increased local bone and tissue concentrations compared to systemic antibiotics alone. The purpose of this study was to evaluate if the addition of a single dose of IO regional antibiotics to our protocol at the time of DAIR would improve outcomes.

Methods

A retrospective case series of 35 PJI TKA patients, with a median age of 67 years (interquartile range (IQR) 61 to 75), who underwent DAIR combined with IO vancomycin (500 mg), was performed with minimum 12 months' follow-up. A total of 26 patients with primary implants were treated for acute perioperative or acute haematogenous infections. Additionally, nine patients were treated for chronic infections with components that were considered unresectable. Primary outcome was defined by no reoperations for infection, nor clinical signs or symptoms of PJI.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1586 - 1594
1 Oct 2021
Sharma N Rehmatullah N Kuiper JH Gallacher P Barnett AJ

Aims

The Oswestry-Bristol Classification (OBC) is an MRI-specific assessment tool to grade trochlear dysplasia. The aim of this study is to validate clinically the OBC by demonstrating its use in selecting treatments that are safe and effective.

Methods

The OBC and the patellotrochlear index were used as part of the Oswestry Patellotrochlear Algorithm (OPTA) to guide the surgical treatment of patients with patellar instability. Patients were assigned to one of four treatment groups: medial patellofemoral ligament reconstruction (MPFLr); MPFLr + tibial tubercle distalization (TTD); trochleoplasty; or trochleoplasty + TTD. A prospective analysis of a longitudinal patellofemoral database was performed. Between 2012 and 2018, 202 patients (233 knees) with a mean age of 24.2 years (SD 8.1), with recurrent patellar instability were treated by two fellowship-trained consultant sports/knee surgeons at The Robert Jones and Agnes Hunt Orthopaedic Hospital. Clinical efficacy of each treatment group was assessed by Kujala, International Knee Documentation Committee (IKDC), and EuroQol five-dimension questionnaire (EQ-5D) scores at baseline, and up to 60 months postoperatively. Their safety was assessed by complication rate and requirement for further surgery. The pattern of clinical outcome over time was analyzed using mixed regression modelling.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 84 - 90
1 Jul 2021
Yang J Olsen AS Serino J Terhune EB DeBenedetti A Della Valle CJ

Aims

The proportion of arthroplasties performed in the ambulatory setting has increased considerably. However, there are concerns whether same-day discharge may increase the risk of complications. The aim of this study was to compare 90-day outcomes between inpatient arthroplasties and outpatient arthroplasties performed at an ambulatory surgery centre (ASC), and determine whether there is a learning curve associated with performing athroplasties in an ASC.

Methods

Among a single-surgeon cohort of 970 patients who underwent arthroplasty at an ASC, 854 (88.0%) were matched one-to-one with inpatients based on age, sex, American Society of Anesthesiologists (ASA) grade, BMI, and procedure (105 could not be adequately matched and 11 lacked 90-day follow-up). The cohort included 281 total hip arthroplasties (THAs) (32.9%), 267 unicompartmental knee arthroplasties (31.3%), 242 primary total knee arthroplasties (TKAs) (28.3%), 60 hip resurfacings (7.0%), two revision THAs (0.3%), and two revision TKAs (0.3%). Outcomes included readmissions, reoperations, visits to the emergency department, unplanned clinic visits, and complications.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 449 - 455
1 Mar 2021
Viberg B Gundtoft PH Schønnemann JO Pedersen L Andersen LR Titlestad K Madsen CF Clemmensen SB Halekoh U Lauritsen J Overgaard S

Aims

To assess the safety of tranexamic acid (TXA) in a large cohort of patients aged over 65 years who have sustained a hip fracture, with a focus on transfusion rates, mortality, and thromboembolic events.

Methods

This is a consecutive cohort study with prospectively collected registry data. Patients with a hip fracture in the Region of Southern Denmark were included over a two-year time period (2015 to 2017) with the first year constituting a control group. In the second year, perioperative TXA was introduced as an intervention. Outcome was transfusion frequency, 30-day and 90-day mortality, and thromboembolic events. The latter was defined as any diagnosis or death due to arterial or venous thrombosis. The results are presented as relative risk (RR) and hazard ratio (HR) with 95% confidence intervals (CIs).


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 347 - 352
1 Feb 2021
Cahan EM Cousins HC Steere JT Segovia NA Miller MD Amanatullah DF

Aims

Surgical costs are a major component of healthcare expenditures in the USA. Intraoperative communication is a key factor contributing to patient outcomes. However, the effectiveness of communication is only partially determined by the surgeon, and understanding how non-surgeon personnel affect intraoperative communication is critical for the development of safe and cost-effective staffing guidelines. Operative efficiency is also dependent on high-functioning teams and can offer a proxy for effective communication in highly standardized procedures like primary total hip and knee arthroplasty. We aimed to evaluate how the composition and dynamics of surgical teams impact operative efficiency during arthroplasty.

Methods

We performed a retrospective review of staff characteristics and operating times for 112 surgeries (70 primary total hip arthroplasties (THAs) and 42 primary total knee arthroplasties (TKAs)) conducted by a single surgeon over a one-year period. Each surgery was evaluated in terms of operative duration, presence of surgeon-preferred staff, and turnover of trainees, nurses, and other non-surgical personnel, controlling cases for body mass index, presence of osteoarthritis, and American Society of Anesthesiologists (ASA) score.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 568 - 572
1 May 2020
McDonnell JM Ahern DP Ó Doinn T Gibbons D Rodrigues KN Birch N Butler JS

Continuous technical improvement in spinal surgical procedures, with the aim of enhancing patient outcomes, can be assisted by the deployment of advanced technologies including navigation, intraoperative CT imaging, and surgical robots. The latest generation of robotic surgical systems allows the simultaneous application of a range of digital features that provide the surgeon with an improved view of the surgical field, often through a narrow portal.

There is emerging evidence that procedure-related complications and intraoperative blood loss can be reduced if the new technologies are used by appropriately trained surgeons. Acceptance of the role of surgical robots has increased in recent years among a number of surgical specialities including general surgery, neurosurgery, and orthopaedic surgeons performing major joint arthroplasty. However, ethical challenges have emerged with the rollout of these innovations, such as ensuring surgeon competence in the use of surgical robotics and avoiding financial conflicts of interest. Therefore, it is essential that trainees aspiring to become spinal surgeons as well as established spinal specialists should develop the necessary skills to use robotic technology safely and effectively and understand the ethical framework within which the technology is introduced.

Traditional and more recently developed platforms exist to aid skill acquisition and surgical training which are described.

The aim of this narrative review is to describe the role of surgical robotics in spinal surgery, describe measures of proficiency, and present the range of training platforms that institutions can use to ensure they employ confident spine surgeons adequately prepared for the era of robotic spinal surgery.

Cite this article: Bone Joint J 2020;102-B(5):568–572.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 655 - 657
1 Jun 2020
Minhas Z Ganau M Thakar C Reynolds J Rothenfluh D Bojanic S Grannum S Chaudhary BR Pyrovolou N Sikander M Bowden G Patel UJ Nnadi C


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 1 - 2
1 Jan 2020
Haddad FS


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 220 - 226
1 Feb 2020
Clough TM Ring J

Aims

Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR.

Methods

We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1479 - 1488
1 Dec 2019
Laverdière C Corban J Khoury J Ge SM Schupbach J Harvey EJ Reindl R Martineau PA

Aims

Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics.

Materials and Methods

A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 98 - 103
1 Jul 2019
Premkumar A Lovecchio FC Stepan JG Sculco PK Jerabek SA Gonzalez Della Valle A Mayman DJ Pearle AD Alexiades MM Albert TJ Cross MB Haas SB

Aims

The aim of this study was to determine the general postoperative opioid consumption and rate of appropriate disposal of excess opioid prescriptions in patients undergoing primary unilateral total knee arthroplasty (TKA).

Patients and Methods

In total, 112 patients undergoing surgery with one of eight arthroplasty surgeons at a single specialty hospital were prospectively enrolled. Three patients were excluded for undergoing secondary procedures within six weeks. Daily pain levels and opioid consumption, quantity, and disposal patterns for leftover medications were collected for six weeks following surgery using a text-messaging platform.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 207 - 212
1 Feb 2019
Clavé A Gérard R Lacroix J Baynat C Danguy des Déserts M Gatineau F Mottier D

Aims

Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol versus the long protocol.

Patients and Methods

A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The efficacy of short- and long-TXA protocols in the reduction of perioperative RBL was compared with a placebo group.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 346 - 351
1 Mar 2018
Goodall R Claireaux H Hill J Wilson E Monsell F BOAST 11 Collaborative Tarassoli P

Aims

Supracondylar fractures are the most frequently occurring paediatric fractures about the elbow and may be associated with a neurovascular injury. The British Orthopaedic Association Standards for Trauma 11 (BOAST 11) guidelines describe best practice for supracondylar fracture management. This study aimed to assess whether emergency departments in the United Kingdom adhere to BOAST 11 standard 1: a documented assessment, performed on presentation, must include the status of the radial pulse, digital capillary refill time, and the individual function of the radial, median (including the anterior interosseous), and ulnar nerves.

Materials and Methods

Stage 1: We conducted a multicentre, retrospective audit of adherence to BOAST 11 standard 1. Data were collected from eight hospitals in the United Kingdom. A total of 433 children with Gartland type 2 or 3 supracondylar fractures were eligible for inclusion. A centrally created data collection sheet was used to guide objective analysis of whether BOAST 11 standard 1 was adhered to. Stage 2: We created a quality improvement proforma for use in emergency departments. This was piloted in one of the hospitals used in the primary audit and was re-audited using equivalent methodology. In all, 102 patients presenting between January 2016 and July 2017 were eligible for inclusion in the re-audit.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 559 - 565
1 May 2018
Bartlett JD Lawrence JE Stewart ME Nakano N Khanduja V

Aims

The aim of this study was to assess the current evidence relating to the benefits of virtual reality (VR) simulation in orthopaedic surgical training, and to identify areas of future research.

Materials and Methods

A literature search using the MEDLINE, Embase, and Google Scholar databases was performed. The results’ titles, abstracts, and references were examined for relevance.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 55 - 61
1 Jan 2018
Kim K Elbuluk A Yu S Iorio R

Aims

The aim of this study was to determine the optimal regimen for the management of pain following total knee arthroplasty (TKA) by comparing the outcomes and cost-effectiveness of different protocols implemented at a large, urban, academic medical centre.

Patients and Methods

Between September 2013 and September 2015, we used a series of modifications to our standard regimen for the management of pain after TKA. In May 2014, there was a department-wide transition from protocols focused on femoral nerve blocks (FNB) to periarticular injections of liposomal bupivacaine. In February 2015, patient-controlled analgesia (PCA) was removed from the protocol while continuing liposomal bupivacaine injections. Quality measures and hospital costs were compared between the three protocols.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1603 - 1610
1 Dec 2017
Dattilo J Gittings D Sloan M Charette R Hume E Lee G

Aims

To evaluate the effectiveness of an institutionally developed algorithm for evaluation and diagnosis of prosthetic joint injection and to determine the impact of this protocol on overall hospital re-admissions.p

Patients and Methods

We retrospectively evaluated 2685 total hip arthroplasty (THA) and total knee arthroplasty (TKA) patients prior to (1263) and following (1422) the introduction of an infection detection protocol. The protocol used conservative thresholds for C-reactive protein to direct the medical attendant to aspirate the joint. The protocol incorporated a clear set of laboratory and clinical criteria that allowed a patient to be discharged home if all were met. Patients were included if they presented to our emergency department within 120 days post-operatively with concerns for swelling, pain or infection and were excluded if they had an unambiguous infection or if their chief complaint was non-orthopaedic in nature.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 303 - 309
1 Mar 2017
Beaulé PE Bleeker H Singh A Dobransky J

Aims

Joint-preserving surgery of the hip (JPSH) has evolved considerably and now includes a number of procedures, including arthroscopy, surgical dislocation, and redirectional osteotomies of the femur and acetabulum. There are a number of different factors which lead to failure of JPSH. Consequently, it is of interest to assess the various modes of failure in order to continue to identify best practice and the indications for these procedures.

Patients and Methods

Using a retrospective observational study design, we reviewed 1013 patients who had undergone JPSH by a single surgeon between 2005 and 2015. There were 509 men and 504 women with a mean age of 39 years (16 to 78). Of the 1013 operations, 783 were arthroscopies, 122 surgical dislocations, and 108 peri-acetabular osteotomies (PAO). We analysed the overall failure rates and modes of failure. Re-operations were categorised into four groups: Mode 1 was arthritis progression or organ failure leading to total hip arthroplasty (THA); Mode 2 was an Incorrect diagnosis/procedure; Mode 3 resulted from malcorrection of femur (type A), acetabulum (type B), or labrum (type C) and Mode 4 resulted from an unintended consequence of the initial surgical intervention.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1373 - 1380
1 Oct 2017
Rienmüller A Buchmann N Kirschke JS Meyer EL Gempt J Lehmberg J Meyer B Ryang YM

Aims

We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF).

Patients and Methods

A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 724 - 731
1 Jun 2017
Mei-Dan O Jewell D Garabekyan T Brockwell J Young DA McBryde CW O’Hara JN

Aims

The aim of this study was to evaluate the long-term clinical and radiographic outcomes of the Birmingham Interlocking Pelvic Osteotomy (BIPO).

Patients and Methods

In this prospective study, we report the mid- to long-term clinical outcomes of the first 100 consecutive patients (116 hips; 88 in women, 28 in men) undergoing BIPO, reflecting the surgeon’s learning curve. Failure was defined as conversion to hip arthroplasty. The mean age at operation was 31 years (7 to 57). Three patients (three hips) were lost to follow-up.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results.

The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies.

Cite this article: Bone Joint J 2016;98-B:892–900.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 291 - 297
1 Mar 2016
Rogmark C Leonardsson O

This review summarises the evidence for the treatment of displaced fractures of the femoral neck in elderly patients. Results from randomised clinical trials and national register studies are presented when available.

The advantages of arthroplasty compared with internal fixation are supported by several studies. A number of studies contribute to the discussions of total hip arthroplasty (THA) versus hemiarthroplasty and unipolar versus bipolar hemiarthroplasty, but no clear-cut evidence-based recommendation can be made. THA may be particularly advantageous for active, lucid patients with a relatively long life expectancy. For patients who are physiologically older, hemiarthoplasty is probably satisfactory, and for the oldest patients with more comorbidities, unipolar implants are considered to be sufficient. If the hospital can support emergency THA surgery in sufficient numbers and quality, there may be few patients who warrant bipolar hemiarthroplasty.

The direct lateral approach reduces the risk of dislocation compared with the posterior approach. Cemented implants lower the risk of periprosthetic fracture and its subsequent morbidity and mortality. As the risk of peri-operative death related to bone cement can be reduced by adequate measures, cemented implants are recommended in fracture cases.

Take home message: There remains a great variation in the surgical management of patients with a hip fracture, and an evidence-based approach should improve the outcomes for this vulnerable patient group.

Cite this article: Bone Joint J 2016;98-B:291–7.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1309 - 1315
1 Oct 2015
Price AJ Erturan G Akhtar K Judge A Alvand A Rees JL

Despite being one of the most common orthopaedic operations, it is still not known how many arthroscopies of the knee must be performed during training in order to develop the skills required to become a Consultant. A total of 54 subjects were divided into five groups according to clinical experience: Novices (n = 10), Junior trainees (n = 10), Registrars (n = 18), Fellows (n = 10) and Consultants (n = 6). After viewing an instructional presentation, each subject performed a simple diagnostic arthroscopy of the knee on a simulator with visualisation and probing of ten anatomical landmarks. Performance was assessed using a validated global rating scale (GRS). Comparisons were made against clinical experience measured by the number of arthroscopies which had been undertaken, and ROC curve analysis was used to determine the number of procedures needed to perform at the level of the Consultants.

There were marked differences between the groups. There was significant improvement in performance with increasing experience (p < 0.05).

ROC curve analysis identified that approximately 170 procedures were required to achieve the level of skills of a Consultant.

We suggest that this approach to identify what represents the level of surgical skills of a Consultant should be used more widely so that standards of training are maintained through the development of an evidenced-based curriculum.

Cite this article: Bone Joint J 2015;97-B:1309–15.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1237 - 1241
1 Sep 2015
Kallala R Haddad FS

Periprosthetic joint infection (PJI) is a devastating complication for patients and results in greatly increased costs of care for both healthcare providers and patients. More than 15 500 revision hip and knee procedures were recorded in England, Wales and Northern Ireland in 2013, with infection accounting for 13% of revision hip and 23% of revision knee procedures.

We report our experience of using antibiotic eluting absorbable calcium sulphate beads in 15 patients (eight men and seven women with a mean age of 64.8 years; 41 to 83) as part of a treatment protocol for PJI in revision arthroplasty.

The mean follow-up was 16 months (12 to 22). We report the outcomes and complications, highlighting the risk of hypercalcaemia which occurred in three patients.

We recommend that serum levels of calcium be routinely sought following the implantation of absorbable calcium sulphate beads in orthopaedic surgery.

Cite this article: Bone Joint J 2015;97-B:1237–41.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1512 - 1518
1 Nov 2015
Courtney PM Melnic CM Gutsche J Hume EL Lee G

Older patients with multiple medical co-morbidities are increasingly being offered and undergoing total joint arthroplasty (TJA). These patients are more likely to require intensive care support, following surgery. We prospectively evaluated the need for intensive care admission and intervention in a consecutive series of 738 patients undergoing elective hip and knee arthroplasty procedures. The mean age was 60.6 years (18 to 91; 440 women, 298 men. Risk factors, correlating with the need for critical care intervention, according to published guidelines, were analysed to identify high-risk patients who would benefit from post-operative critical care monitoring. A total of 50 patients (6.7%) in our series required critical care level interventions during their hospital stay. Six independent multivariate clinical predictors were identified (p < 0.001) including a history of congestive heart failure (odds ratio (OR) 24.26, 95% confidence interval (CI) 9.51 to 61.91), estimated blood loss >  1000 mL (OR 17.36, 95% CI 5.36 to 56.19), chronic obstructive pulmonary disease (13.90, 95% CI 4.78 to 40.36), intra-operative use of vasopressors (OR 8.10, 95% CI 3.23 to 20.27), revision hip arthroplasty (OR 2.71, 95% CI 1.04 to 7.04) and body mass index > 35 kg/m2 (OR 2.70, 95% CI 123 to 5.94). The model was then validated against an independent, previously published data set of 1594 consecutive patients. The use of this risk stratification model can be helpful in predicting which high-risk patients would benefit from a higher level of monitoring and care after elective TJA and aid hospitals in allocating precious critical care resources.

Cite this article: Bone Joint J 2015;97-B:1512–18.