Advertisement for orthosearch.org.uk
Results 1 - 50 of 318
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 334 - 335
1 Mar 2008
Bollen SR Arvinte D

We present a series of four patients with what we have termed the snapping pes syndrome. This is a painful clicking and catching experienced at the posteromedial corner of the knee when moving from flexion to extension. Clinical examination and real time ultrasound are the most useful diagnostic tools. If medical treatment is unsuccessful surgical excision of both the semitendinous and gracilis tendons is indicated for relief of persistent symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 250 - 254
1 Mar 1999
Duncan RDD Fixsen JA

Congenital convex pes valgus (congenital vertical talus) is a rare condition. We reviewed ten feet in seven patients who had had surgical correction. All had been operated on by the senior author (JF) and the same surgical technique was used throughout, incorporating transfer of the tibialis anterior to the neck of the talus. The mean age at surgery was 31 months and the mean follow-up was nine years (6 to 14). All patients completed a questionnaire and had clinical, radiological and photographic evaluation performed by an independent examiner. None had required further surgery. All but one were satisfied with the result, and had no functional limitations. They all wore normal shoes. The mean ankle dorsiflexion was 17° and plantar flexion 21°. The mean arc of subtalar motion was 27°. All radiological parameters measured were within the normal range, although irregularity of the talonavicular joint was common. No avascular necrosis of the body of the talus was seen. We conclude that the medium-term results of this procedure are very satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 399 - 403
1 Aug 1981
Baksi D

Lateral instability of the patella was found after recurrent, habitual and permanent dislocations. Contracture of soft tissues lateral to the patella only occurred with habitual and permanent dislocations, but medial laxity was present in all cases. After adequate release of the lateral contracture, the medial stability was improved by transposition of the lower three-quarters of the pes anserinus to the medial border of the patella, and the patellar ligament. This created a relatively unstretchable physiological sling which ensured dynamic stability of the patella. Six recurrent, 21 habitual and nine permanent dislocations of the patella were treated by this method. Results were excellent in 21 patients, good in 13 and fair in two. The follow-up period varied from 21 to 84 months. There have been no recurrences to date


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1660 - 1665
1 Dec 2007
Krause F Windolf M Schwieger K Weber M

A cavovarus foot deformity was simulated in cadaver specimens by inserting metallic wedges of 15° and 30° dorsally into the first tarsometatarsal joint. Sensors in the ankle joint recorded static tibiotalar pressure distribution at physiological load.

The peak pressure increased significantly from neutral alignment to the 30° cavus deformity, and the centre of force migrated medially. The anterior migration of the centre of force was significant for both the 15° (repeated measures analysis of variance (ANOVA), p = 0.021) and the 30° (repeated measures ANOVA, p = 0.007) cavus deformity. Differences in ligament laxity did not influence the peak pressure.

These findings support the hypothesis that the cavovarus foot deformity causes an increase in anteromedial ankle joint pressure leading to anteromedial arthrosis in the long term, even in the absence of lateral hindfoot instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 729 - 734
1 Jun 2012
Kakkos SK Warwick D Nicolaides AN Stansby GP Tsolakis IA

We performed a systematic review and meta-analysis to compare the efficacy of intermittent mechanical compression combined with pharmacological thromboprophylaxis, against either mechanical compression or pharmacological prophylaxis in preventing deep-vein thrombosis (DVT) and pulmonary embolism in patients undergoing hip or knee replacement. A total of six randomised controlled trials, evaluating a total of 1399 patients, were identified. In knee arthroplasty, the rate of DVT was reduced from 18.7% with anticoagulation alone to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03; number needed to treat: seven). There was moderate, albeit non-significant, heterogeneity (I2 = 42%). In hip replacement, there was a non-significant reduction in DVT from 8.7% with mechanical compression alone to 7.2% with additional pharmacological prophylaxis (RR 0.84) and a significant reduction in DVT from 9.7% with anticoagulation alone to 0.9% with additional mechanical compression (RR 0.17, p < 0.001; number needed to treat: 12), with no heterogeneity (I2 = 0%). The included studies had insufficient power to demonstrate an effect on pulmonary embolism.

We conclude that the addition of intermittent mechanical leg compression augments the efficacy of anticoagulation in preventing DVT in patients undergoing both knee and hip replacement. Further research on the role of combined modalities in thromboprophylaxis in joint replacement and in other high-risk situations, such as fracture of the hip, is warranted.


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1791 - 1801
1 Dec 2021
Bhalekar RM Nargol ME Shyam N Nargol AVF Wells SR Collier R Pabbruwe M Joyce TJ Langton DJ

Aims. The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). Methods. At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays. Results. A total of 114 explanted fixed-bearing TKAs were examined. This included 76 used with contemporary PE inserts which were compared with 15 used with older generation PEs. The Attune and NexGen (central locking) trays were found to have significantly less cement cover than Triathlon and PFC trays (peripheral locking group) (p = 0.001). The median planicity values of the PE inserts used with central locking trays were significantly greater than of those with peripheral locking inserts (205 vs 85 microns; p < 0.001). Attune and NexGen inserts had a characteristic pattern of backside deformation, with the outer edges of the PE deviating inferiorly, leaving the PE margins as the primary areas of articulation. Conclusion. Explanted TKAs with central locking mechanisms were significantly more likely to debond from the cement mantle. The PE inserts of these designs showed characteristic patterns of deformation, which appeared to relate to the manufacturing process and may be exacerbated in vivo. This pattern of deformation was associated with PE wear occurring at the outer edges of the articulation, potentially increasing the frictional torque generated at this interface. Cite this article: Bone Joint J 2021;103-B(12):1791–1801


Aims. The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs). Methods. A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints. Results. There was no clinically relevant difference in terms of tibial component migration, insert wear, and PROMs between the HXLPE and PE groups. The mean difference in tibial component migration (maximal total point migration (MTPM)) was 0.02 mm (95% confidence interval (CI) -0.07 to 0.11), which is below the value of 0.2 mm considered to be clinically relevant. Wear after five years for HXLPE was 0.16 mm (95% CI 0.05 to 0.27), and for PE was 0.23 mm (95% CI 0.12 to 0.35). The mean difference in wear rate was 0.01 mm/year (95% CI -0.02 to 0.05) in favour of the HXLPE group. Wear is mainly present on the medial side of the insert. Conclusion. There is no clinically relevant difference in tibial component migration and insert wear for up to five years between the HXLPE conventional PE inserts. For the implant studied, the potential advantages of a HXLPE insert remain to be proven under clinical conditions at longer-term follow-up. Cite this article: Bone Joint J 2023;105-B(5):518–525


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1809 - 1814
1 Dec 2021
Nakamura T Kawai A Hagi T Asanuma K Sudo A

Aims. Patients with soft-tissue sarcoma (STS) who undergo unplanned excision (UE) are reported to have worse outcomes than those who undergo planned excision (PE). However, others have reported that patients who undergo UE may have similar or improved outcomes. These discrepancies are likely to be due to differences in characteristics between the two groups of patients. The aim of the study is to compare patients who underwent UE and PE using propensity score matching, by analyzing data from the Japanese Bone and Soft Tissue Tumor (BSTT) registry. Methods. Data from 2006 to 2016 was obtained from the BSTT registry. Only patients with STS of the limb were included in the study. Patients with distant metastasis at the initial presentation and patients with dermatofibrosarcoma protuberans and well-differentiated liposarcoma were excluded from the study. Results. A total of 4,483 patients with STS of the limb were identified before propensity score matching. There were 355 patients who underwent UE and 4,128 patients who underwent PE. The five-year disease-specific survival (DSS) rate was significantly better in the patients who received additional excision after UE than in those who underwent PE. There was no significant difference in local recurrence-free survival (LRFS) between the two groups. After propensity score matching, a new cohort of 355 patients was created for both PE and UE groups, in which baseline covariates were appropriately balanced. Reconstruction after tumour excision was frequently performed in patients who underwent additional excision after UE. There were no significant differences in DSS and LRFS between the patients who underwent PE and those who had an additional excision after UE. Conclusion. Using propensity score matching, patients with STS of the limb who underwent additional excision after UE did not experience higher mortality and local failure than those who underwent PE. Reconstruction may be necessary when additional excision is performed. Cite this article: Bone Joint J 2021;103-B(12):1809–1814


Aims. The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. Methods. A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up. Results. There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group. Conclusion. There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA. Cite this article: Bone Joint J 2024;106-B(8):826–833


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims. The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture. Methods. All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT. Results. A total of 191 patients were included. A DVT was found preoperatively in 12 patients (6.3%), of which six were proximal. A postoperative DVT was found in 42 patients (22%), of which 27 were proximal. Eight patients (4.2%) had a PE, which was secondary to a DVT in three. None of the 12 patients in whom a vena cava filter was implanted prophylactically had a PE. Multivariate logistic regression analysis indicated that the association with the need for spinal surgery (odds ratio (OR) 19.78 (95% confidence interval (CI) 1.12 to 348.08); p = 0.041), intramedullary nailing of a long bone fracture (OR 4.44 (95% CI 1.05 to 18.86); p = 0.043), an operating time > two hours (OR 3.28 (95% CI 1.09 to 9.88); p = 0.035), and additional trauma surgery (OR 3.1 (95% CI 1.03 to 9.45); p = 0.045) were statistically the most relevant independent predictors of a postoperative DVT. Conclusion. The acknowledgement of the risk factors for the development of a DVT and their weight is crucial to set a threshold for the index of suspicion for this diagnosis by medical staff. We suggest the routine use of the DUS screening for DVT in patients with a pelvic and/or acetabular fracture before and six to ten days after surgery. Cite this article: Bone Joint J 2022;104-B(2):283–289


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims. Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). Methods. We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. Results. Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). Conclusion. The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision. Cite this article: Bone Joint J 2022;104-B(7):801–810


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1695 - 1701
1 Nov 2021
Currier JH Currier BH Abdel MP Berry DJ Titus AJ Van Citters DW

Aims. Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. Methods. An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate. Results. Five patient-specific variables and seven implant-specific variables were evaluated for significant association with lower insert wear rate. Six were significant when controlling for other factors: greater patient age, female sex, shorter duration in vivo, polished tray, highly cross-linked PE (HXLPE), and constrained knee design. Conclusion. This study confirmed that knee wear rate increased with duration in vivo. Older patients and females had significantly lower wear rates. Polished modular tibial tray surfaces, HXLPE, and constrained TKA designs were device design factors associated with significantly reduced wear rate. Cite this article: Bone Joint J 2021;103-B(11):1695–1701


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 71 - 77
1 Jul 2020
Gonzalez Della Valle A Shanaghan KA Nguyen J Liu J Memtsoudis S Sharrock NE Salvati EA

Aims. We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE. Methods. Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality. Results. Postoperative VTE was diagnosed in seven patients (2.5%): DVT in five, and PE with and without DVT in one patient each. After hospitalization, three patients required readmiss-ion for evacuation of a haematoma, one for wound drainage, and one for monitoring of an elevated international normalized ratio (INR). Seven patients died (2.5%). One patient died five months postoperatively of a PE during open thrombectomy. She had discontinued anticoagulation. One patient died of a haemorrhagic stroke while receiving Coumadin. PE or bleeding was not suspected in the remaining five fatalities. Conclusion. Multimodal prophylaxis is safe and effective in patients with a history of VTE. Postoperative anticoagulation should be prudent as very few patients developed VTE (2.5%) or died of suspected or confirmed PE. Mortality during the first year was mostly unrelated to either VTE or bleeding. Cite this article: Bone Joint J 2020;102-B(7 Supple B):71–77


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1743 - 1751
1 Dec 2020
Lex JR Evans S Cool P Gregory J Ashford RU Rankin KS Cosker T Kumar A Gerrand C Stevenson J

Aims. Malignancy and surgery are risk factors for venous thromboembolism (VTE). We undertook a systematic review of the literature concerning the prophylactic management of VTE in orthopaedic oncology patients. Methods. MEDLINE (PubMed), EMBASE (Ovid), Cochrane, and CINAHL databases were searched focusing on VTE, deep vein thrombosis (DVT), pulmonary embolism (PE), bleeding, or wound complication rates. Results. In all, 17 studies published from 1998 to 2018 met the inclusion criteria for the systematic review. The mean incidence of all VTE events in orthopaedic oncology patients was 10.7% (1.1% to 27.7%). The rate of PE was 2.4% (0.1% to 10.6%) while the rate of lethal PE was 0.6% (0.0% to 4.3%). The overall rate of DVT was 8.8% (1.1% to 22.3%) and the rate of symptomatic DVT was 2.9% (0.0% to 6.2%). From the studies that screened all patients prior to hospital discharge, the rate of asymptomatic DVT was 10.9% (2.0% to 20.2%). The most common risk factors identified for VTE were endoprosthetic replacements, hip and pelvic resections, presence of metastases, surgical procedures taking longer than three hours, and patients having chemotherapy. Mean incidence of VTE with and without chemical prophylaxis was 7.9% (1.1% to 21.8%) and 8.7% (2.0% to 23.4%; p = 0.11), respectively. No difference in the incidence of bleeding or wound complications between prophylaxis groups was reported. Conclusion. Current evidence is limited to guide clinicians. It is our consensus opinion, based upon logic and deduction, that all patients be considered for both mechanical and chemical VTE prophylaxis, particularly in high-risk patients (pelvic or hip resections, prosthetic reconstruction, malignant diagnosis, presence of metastases, or surgical procedures longer than three hours). Additionally, the surgeon must determine, in each patient, if the risk of haemorrhage outweighs the risk of VTE. No individual pharmacological agent has been identified as being superior in the prevention of VTE events. Cite this article: Bone Joint J 2020;102-B(12)1743:–1751


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 938 - 944
1 Jul 2018
Karayiannis PN Hill JC Stevenson C Finnegan S Armstrong L Beverland D

Aims. The aims of this study were to determine the indications and frequency of ordering a CT pulmonary angiography (CTPA) following primary arthroplasty of the hip and knee, and to determine the number of positive scans in these patients, the location of emboli and the outcome for patients undergoing CTPA. Patients and Methods. We analyzed the use of CTPA, as an inpatient and up to 90 days as an outpatient, in a cohort of patients and reviewed the medical records and imaging for each patient undergoing CTPA. Results. Out of 11 249 patients, scans were requested in 229 (2.04%) and 86 (38%) were positive. No patient undergoing CTPA died within 90 days. The rate of mortality from pulmonary embolism (PE) overall was 0.08%. CTPA was performed twice as often following total knee arthroplasty (TKA) compared with total hip arthroplasty (THA), and when performed was twice as likely to be positive. Hypoxia was the main indication for a scan, being the indication in 149 scans (65%); and in 23% (11 of 47), the PE was peripheral and unilateral. Three patients suffered complications resulting from therapeutic anticoagulation for possible PE, two of whom had a negative CTPA. Conclusion. CTPA is more likely to be performed following TKA compared with THA. Hypoxia was the main presenting feature of PE. A quarter of PEs which were diagnosed were unilateral and peripheral. Further study may indicate which patients who have a PE after lower limb arthroplasty require treatment, and which can avoid the complications associated with anticoagulation. Cite this article: Bone Joint J 2018;100-B:938–44


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 68 - 75
1 Jan 2018
Goel R Fleischman AN Tan T Sterbis E Huang R Higuera C Parvizi J Rothman RH

Aims. The aims of this study were to compare the efficacy of two agents, aspirin and warfarin, for the prevention of venous thromboembolism (VTE) after simultaneous bilateral total knee arthroplasty (SBTKA), and to elucidate the risk of VTE conferred by this procedure compared with unilateral TKA (UTKA). Patients and Methods. A retrospective, multi-institutional study was conducted on 18 951 patients, 3685 who underwent SBTKA and 15 266 who underwent UTKA, using aspirin or warfarin as VTE prophylaxis. Each patient was assigned an individualised baseline VTE risk score based on a system using the Nationwide Inpatient Sample. Symptomatic VTE, including pulmonary embolism (PE) and deep vein thrombosis (DVT), were identified in the first 90 days post-operatively. Statistical analyses were performed with logistic regression accounting for baseline VTE risk. Results. The adjusted incidence of PE following SBTKA was 1.0% (95% confidence interval (CI) 0.86 to 1.2) with aspirin and 2.2% (95% CI 2.0 to 2.4) with warfarin. Similarly, the adjusted incidence of VTE following SBTKA was 1.6% (95% CI 1.1 to 2.3) with aspirin and 2.5% (95% CI 1.9 to 3.3) with warfarin. The risk of PE and VTE were reduced by 66% (odds ratio (OR) 0.44, 95% CI 0.25 to 0.78) and 38% (OR 0.62, 95% CI 0.38 to 1.0), respectively, using aspirin. In addition, the risk of PE was 204% higher for patients undergoing SBTKA relative to those undergoing UTKA. For each ten-point increase in baseline VTE risk, the risk of PE increased by 25.5% for patients undergoing SBTKA compared with 10.5% for those undergoing UTKA. Patients with a history of myocardial infarction or peripheral vascular disease had the greatest increase in risk from undergoing SBTKA instead of UTKA. Conclusion. Aspirin is more effective than warfarin for the prevention of VTE following SBTKA, and serves as the more appropriate agent for VTE prophylaxis for patients in all risk categories. Furthermore, patients undergoing SBTKA are at a substantially increased risk of VTE, even more so for those with significant underlying risk factors. Patients should be informed about the risks associated with undergoing SBTKA. Cite this article: Bone Joint J 2018;100-B(1 Supple A):68–75


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1330 - 1335
1 Oct 2018
Ponzio DY Weitzler L deMeireles A Esposito CI Wright TM Padgett DE

Aims. The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts. Materials and Methods. A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces. Results. A-XLPE inserts had higher rates of burnishing and lower rates of pitting and scratching compared with XLPE. There were no differences in the density of crosslinking at loaded and unloaded regions. A-XLPE showed higher oxidation indices in the unloaded surface region compared with XLPE. There were no differences in the levels of oxidation in the loaded regions. Conclusion. Retrieval analysis of A-XLPE did not reflect a clinically relevant difference in surface damage, density of crosslinking, or oxidation compared with XLPE tibial inserts at short-term evaluation. Cite this article: Bone Joint J 2018;100-B:1330–5


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 341 - 348
1 Mar 2016
Ogonda L Hill J Doran E Dennison J Stevenson M Beverland D

Aims. The aim of this study was to present data on 11 459 patients who underwent total hip (THA), total knee (TKA) or unicompartmental knee arthroplasty (UKA) between November 2002 and April 2014 with aspirin as the primary agent for pharmacological thromboprophylaxis. . Patients and Methods. We analysed the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) then compared the 90-day all-cause mortality with the corresponding data in the National Joint Registry for England and Wales (NJR). . Results. The incidence of PE was 0.6% after THA, 1.47% after TKA and 1.2% after UKA. The 90-day mortality was 0.39% after THA and 0.44% after TKA. No deaths occurred after UKA. The main causes of death were ischaemic heart disease and respiratory failure. PE was responsible for only 18% of deaths. There was a decline in 90-day mortality, from 0.64% between 2002 and 2007, to 0.21% between 2008 and 2013 after THA, and from 0.47% to 0.39% after TKA for the corresponding period. The standardised mortality ratio (SMR) declined from 86.5 (confidence interval (CI) 63.0 to 137.7) to 39.7 (CI 31.2 to 54.3) p = 0.024. The incidence of proximal DVT was 0.3%. . Take home message: With individualised risk assessment and as part of a multimodal approach, Aspirin is safe to use as the main thromboprophylactic agent in primary arthroplasty. It is not associated with an increased incidence of symptomatic DVT, PE or death. . Cite this article: Bone Joint J 2016;98-B:341-8


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 113 - 121
1 Jan 2012
Poultsides LA Gonzalez Della Valle A Memtsoudis SG Ma Y Roberts T Sharrock N Salvati E

We performed a meta-analysis of modern total joint replacement (TJR) to determine the post-operative mortality and the cause of death using different thromboprophylactic regimens as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran, fondaparinux or rivaroxaban); 3) Potent anticoagulation combined (PAC) with regional anaesthesia and/or pneumatic compression devices (PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional anaesthesia, PCDs and aspirin in low-risk patients. Cause of death was classified as autopsy proven, clinically certain or unknown. Deaths were grouped into cardiopulmonary excluding pulmonary embolism (PE), PE, bleeding-related, gastrointestinal, central nervous system, and others (miscellaneous). Meta-analysis based on fixed effects or random effects models was used for pooling incidence data. In all, 70 studies were included (99 441 patients; 373 deaths). The mortality was lowest in the MM (0.2%) and WC (0.2%) groups. The most frequent cause of death was cardiopulmonary (47.9%), followed by PE (25.4%) and bleeding (8.9%). The proportion of deaths due to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%; PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%; PAC, 10.8%) but the differences were not statistically significant. Our study demonstrated that the routine use of PA does not reduce the overall mortality or the proportion of deaths due to PE


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims

Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice.

Methods

This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m2 (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1348 - 1355
1 Nov 2019
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar M Turgeon T

Aims. A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods. Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results. Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm. 3. /year (supine) and 39.3 mm. 3. /year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm. 3. No significant associations were found between patient demographics or function scores and measured wear. Conclusion. In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA. Cite this article: Bone Joint J 2019;101-B:1348–1355


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 46 - 52
1 Jul 2021
McGoldrick NP Fischman D Nicol GM Kreviazuk C Grammatopoulos G Beaulé PE

Aims

The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach.

Methods

A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1192 - 1198
1 Oct 2019
Sköldenberg OG Rysinska AD Chammout G Salemyr M Mukka SS Bodén H Eisler T

Aims. Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. Patients and Methods. We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (. sd. 5), in a double-blinded, noninferiority, randomized controlled trial. The subjects were randomized in a 1:1 ratio to receive a reverse hybrid THA with a cemented component of either argon-gas gamma-sterilized PE component (controls) or VEPE, with identical geometry. The primary endpoint was proximal implant migration of the component at two years postoperatively measured with RSA. Secondary endpoints included total migration of the component, penetration of the femoral head into the component, and patient-reported outcome measurements. Results. In total, 19 control implants and 18 implants in the VEPE group were analyzed for the primary endpoint. We found a continuous proximal migration of the component in the VEPE group that was significantly higher with a difference at two years of a mean 0.21 mm (95% confidence interval (CI) 0.05 to 0.37; p = 0.013). The total migration was also significantly higher in the VEPE group, but femoral head penetration was lower. We found no difference in clinical outcomes between the groups. Conclusion. At two years, this cemented VEPE component, although having a low head penetration and excellent clinical results, failed to meet noninferiority compared with the conventional implant by a proximal migration above the proposed safety threshold of RSA. The early proximal migration pattern of the VEPE component is a reason for continued monitoring, although a specific threshold for proximal migration and risk for later failure cannot be defined and needs further study. Cite this article: Bone Joint J 2019;101-B:1192–1198


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims. The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure. Patients and Methods. A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery. Results. We observed similar bedding in one year postoperatively and wear two years postoperatively between the two types of liner. However, there was significantly more penetration of the femoral head in the ModXLPE cohort compared with the VEPE cohort five years postoperatively (p < 0.001). The only variables independently predictive of increased wear were ModXLPE (vs VEPE) liner type (β = 0.22, p = 0.010) and metal (vs ceramic) femoral head (β = 0.21, p = 0.013). There was no association between increased wear and the development of radiolucency (p = 0.866) or PROMs. No patient had evidence of osteolysis. Conclusion. Five years postoperatively, patients with VEPE (vs ModXLPE) and ceramic (vs metal) femoral heads had decreased wear. The rates of wear for both liners were very low and have not led to any osteolysis or implant failure due to aseptic loosening


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 837 - 844
1 Jun 2014
Ramanoudjame M Loriaut P Seringe R Glorion C Wicart P

In this study we evaluated the results of midtarsal release and open reduction for the treatment of children with convex congenital foot (CCF) (vertical talus) and compared them with the published results of peritalar release. Between 1977 and 2009, a total of 22 children (31 feet) underwent this procedure. In 15 children (48%) the CCF was isolated and in the remainder it was not (seven with arthrogryposis, two with spinal dysraphism, one with a polymalformative syndrome and six with an undefined neurological disorder). Pre-operatively, the mean tibiotalar angle was 150.2° (106° to 175°) and the mean calcaneal pitch angle was -19.3° (-72° to 4°). The procedure included talonavicular and calcaneocuboid joint capsulotomies, lengthening of tendons of tibialis anterior and the extensors of the toes, allowing reduction of the midtarsal joints. Lengthening of the Achilles tendon was necessary in 23 feet (74%). The mean follow-up was 11 years (2 to 21). The results, as assessed by the Adelaar score, were good in 24 feet (77.4%), fair in six (19.3%) and poor in one foot (3.3%), with no difference between those with isolated CCF and those without. The mean American Orthopaedic Foot and Ankle Society midfoot score was 89.9 (54 to 100) and 77.8 (36 to 93) for those with isolated CCF and those without, respectively. At the final follow-up, the mean tibiotalar (120°; 90 to 152) and calcaneal pitch angles (4°; -13 to 22) had improved significantly (p < 0.0001). Dislocation of the talonavicular and calcaneocuboid joints was completely reduced in 22 (70.9%) and 29 (93.6%) of feet, respectively. Three children (five feet) underwent further surgery at a mean of 8.5 years post-operatively, three with pes planovalgus and two in whom the deformity had been undercorrected. No child developed avascular necrosis of the talus. Midtarsal joint release and open reduction is a satisfactory procedure, which may provide better results than peritalar release. Complications include the development of pes planovalgus and persistent dorsal subluxation of the talonavicular joint. Cite this article: Bone Joint J 2014;96-B:837–44


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 34 - 40
1 Jan 2019
Kraus Schmitz J Lindgren V Janarv P Forssblad M Stålman A

Aims. The aim of this study was to investigate the incidence, risk factors, and outcome of venous thromboembolism (VTE) following anterior cruciate ligament (ACL) reconstruction in a nationwide cohort. Patients and Methods. All ACL reconstructions, primary and revision, that were recorded in the Swedish Knee Ligament Register (SKLR) between 2006 and 2013 were linked with data from the Swedish National Board of Health and Welfare. The incidence of VTE was determined by entries between the day of surgery until 90 days postoperatively based on diagnosis codes and the prescription of anticoagulants. Risk factors, outcome, and the use of thromboprophylaxis were analyzed. Descriptive statistics with multivariate analysis were used to describe the findings. Results. The cohort consisted of 26 014 primary and revision ACL reconstructions. There were 89 deep venous thromboses (DVTs) and 12 pulmonary emboli (PEs) with a total of 95 VTEs (0.4 %). Six patients with a PE had a simultaneous DVT. The only independent risk factor for VTE was age greater than or equal to 40 years (odds ratio 2.31, 95% confidence interval 1.45 to 3.70; p < 0.001). Thromboprophylaxis was prescribed to 9461 patients (36%) and was equally distributed between those with and those without a VTE (37.9% vs 36.4%). All patient-reported outcome measures (PROMs) one and two years postoperatively were significantly lower in those with VTE. Conclusion. The incidence of VTE following ACL reconstruction is 0.4%, and the only significant risk factor is age. Patients with VTE had worse postoperative clinical outcome than patients without VTE. We recommend against the routine use of thromboprophylaxis, but it should be considered in older patients


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 838 - 838
1 Jun 2006
BEAULÉ PE


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 915 - 919
1 Aug 2002
Bechtold JE Kubic V Søballe K

We have investigated whether the presence of polyethylene (PE) alone is sufficient to cause an aggressive periprosthetic tissue response, or whether certain mechanical interface conditions can allow bone to grow while in the presence of PE. An experimental implant was loaded in the presence and absence of particulate PE under stable and unstable conditions. Bone with a thin, discontinuous fibrous membrane formed in both groups of stable implants, either in the presence or absence of PE. By contrast, a continuous fibrous membrane consistently formed in both groups of unstable implants. The membrane consisted of loose fibrous connective tissue when PE was absent, and dense connective tissue with macrophages and a synovial lining when PE was present. In this model, if the interface was stable, the presence of PE was not sufficient to prevent the formation of bone or to produce a phagocytic tissue response. Only when the interface was unstable did a fibrous membrane form, and only then in the presence of PE


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 462 - 462
1 Apr 2003
BEAULÉ PE


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 924 - 934
1 Sep 2024
Cheok T Beveridge A Berman M Coia M Campbell A Tse TTS Doornberg JN Jaarsma RL

Aims

We investigated the efficacy and safety profile of commonly used venous thromboembolism (VTE) prophylaxis agents following hip and knee arthroplasty.

Methods

A systematic search of PubMed, Embase, Cochrane Library, Web of Science, and OrthoSearch was performed. Prophylaxis agents investigated were aspirin (< 325 mg and ≥ 325 mg daily), enoxaparin, dalteparin, fondaparinux, unfractionated heparin, warfarin, rivaroxaban, apixaban, and dabigatran. The primary efficacy outcome of interest was the risk of VTE, whereas the primary safety outcomes of interest were the risk of major bleeding events (MBE) and wound complications (WC). VTE was defined as the confirmed diagnosis of any deep vein thrombosis and/or pulmonary embolism. Network meta-analysis combining direct and indirect evidence was performed. Cluster rank analysis using the surface under cumulative ranking (SUCRA) was applied to compare each intervention group, weighing safety and efficacy outcomes.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1052 - 1059
1 Oct 2023
El-Sahoury JAN Kjærgaard K Ovesen O Hofbauer C Overgaard S Ding M

Aims

The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA).

Methods

A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


Aims

The aim of this study was to evaluate the healthcare costs and benefits of enoxaparin compared to aspirin in the prevention of symptomatic venous thromboembolism (VTE) after total hip arthroplasty (THA) or total knee arthroplasty (TKA) using data from the CRISTAL trial.

Methods

This trial-based economic analysis reports value for money as incremental cost per quality-adjusted life-year (QALY) gained in 2022 Australian dollars, compared to a single threshold value of AUD$70,000 per QALY. Event costs were estimated based on occurrence of VTEs and bleeds, and on published guidelines for treatment. Unit costs were taken from Australian sources. QALYs were estimated using CRISTAL six-month follow-up data. Sensitivity analyses are presented that vary the cost of VTE treatment, and extend the analyses to two years.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 239 - 246
1 Mar 2023
Arshad Z Aslam A Al Shdefat S Khan R Jamil O Bhatia M

Aims

This systematic review aimed to summarize the full range of complications reported following ankle arthroscopy and the frequency at which they occur.

Methods

A computer-based search was performed in PubMed, Embase, Emcare, and ISI Web of Science. Two-stage title/abstract and full-text screening was performed independently by two reviewers. English-language original research studies reporting perioperative complications in a cohort of at least ten patients undergoing ankle arthroscopy were included. Complications were pooled across included studies in order to derive an overall complication rate. Quality assessment was performed using the Oxford Centre for Evidence-Based Medicine levels of evidence classification.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 642 - 645
1 Jul 2024
Harris IA Sidhu VS MacDessi SJ Solomon M Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims

Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs.

Methods

A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m2 (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19).


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1126 - 1131
1 Oct 2022
Hannon CP Kruckeberg BM Pagnano MW Berry DJ Hanssen AD Abdel MP

Aims

We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years.

Methods

The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims

The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years.

Methods

All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 174 - 181
1 Feb 2024
Mandalia KP Brodeur PG Li LT Ives K Cruz Jr. AI Shah SS

Aims

The aim of this study was to characterize the influence of social deprivation on the rate of complications, readmissions, and revisions following primary total shoulder arthroplasty (TSA), using the Social Deprivation Index (SDI). The SDI is a composite measurement, in percentages, of seven demographic characteristics: living in poverty, with < 12 years of education, single-parent households, living in rented or overcrowded housing, households without a car, and unemployed adults aged < 65 years.

Methods

Patients aged ≥ 40 years, who underwent primary TSA between 2011 and 2017, were identified using International Classification of Diseases (ICD)-9 Clinical Modification and ICD-10 procedure codes for TSA in the New York Statewide Planning and Research Cooperative System database. Readmission, reoperation, and other complications were analyzed using multivariable Cox proportional hazards regression controlling for SDI, age, ethnicity, insurance status, and Charlson Comorbidity Index.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 730 - 735
1 Jun 2016
Bsat S Frei H Beaulé PE

The acetabular labrum is a soft-tissue structure which lines the acetabular rim of the hip joint. Its role in hip joint biomechanics and joint health has been of particular interest over the past decade. In normal hip joint biomechanics, the labrum is crucial in retaining a layer of pressurised intra-articular fluid for joint lubrication and load support/distribution. Its seal around the femoral head is further regarded as a contributing to hip stability through its suction effect. The labrum itself is also important in increasing contact area thereby reducing contact stress. Given the labrum’s role in normal hip joint biomechanics, surgical techniques for managing labral damage are continuously evolving as our understanding of its anatomy and function continue to progress. The current paper aims to review the anatomy and biomechanical function of the labrum and how they are affected by differing surgical techniques.

Take home message: The acetabular labrum plays a critical role in hip function and maintaining and restoring its function during surgical intervention remain an essential goal.

Cite this article: Bone Joint J 2016;98-B:730–5.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 81 - 88
1 Mar 2024
Lustig S Cotte M Foissey C Asirvatham RD Servien E Batailler C

Aims

The benefit of a dual-mobility acetabular component (DMC) for primary total hip arthroplasties (THAs) is controversial. This study aimed to compare the dislocation and complication rates when using a DMC compared to single-mobility (SM) acetabular component in primary elective THA using data collected at a single centre, and compare the revision rates and survival outcomes in these two groups.

Methods

Between 2010 and 2019, 2,075 primary THAs using either a cementless DM or SM acetabular component were included. Indications for DMC were patients aged older than 70 years or with high risk of dislocation. All other patients received a SM acetabular component. Exclusion criteria were cemented implants, patients treated for femoral neck fracture, and follow-up of less than one year. In total, 1,940 THAs were analyzed: 1,149 DMC (59.2%) and 791 SM (40.8%). The mean age was 73 years (SD 9.2) in the DMC group and 57 years (SD 12) in the SM group. Complications and revisions have been analyzed retrospectively.


Aims

Total knee arthroplasty (TKA) may provoke ankle symptoms. The aim of this study was to validate the impact of the preoperative mechanical tibiofemoral angle (mTFA), the talar tilt (TT) on ankle symptoms after TKA, and assess changes in the range of motion (ROM) of the subtalar joint, foot posture, and ankle laxity.

Methods

Patients who underwent TKA from September 2020 to September 2021 were prospectively included. Inclusion criteria were primary end-stage osteoarthritis (Kellgren-Lawrence stage IV) of the knee. Exclusion criteria were missed follow-up visit, post-traumatic pathologies of the foot, and neurological disorders. Radiological angles measured included the mTFA, hindfoot alignment view angle, and TT. The Foot Function Index (FFI) score was assessed. Gait analyses were conducted to measure mediolateral changes of the gait line and ankle laxity was tested using an ankle arthrometer. All parameters were acquired one week pre- and three months postoperatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 6 - 10
1 Jan 1995
Warwick D Williams M Bannister G

We studied 1162 consecutive total hip replacements (THR) to establish the incidence of fatal pulmonary embolism (PE), clinical non-fatal PE and deep-vein thrombosis (DVT) in the six months after surgery. Chemical thromboprophylaxis had not been routinely used. We used a validated questionnaire supplemented by post-mortem records and a review of the clinical notes. Follow-up was 100%. The death rate from PE was 0.34% (95% CI 0.09 to 0.88), with one fatal PE after discharge 40 days after operation. The clinical PE rate confirmed by imaging was 1.20% (CI 0.65 to 2.02), with 0.7% of patients readmitted. The venographically-confirmed clinical DVT rate was 1.89% (CI 1.11 to 2.76), with 1.13% readmitted. The total thromboembolic morbidity was 3.4% (95% CI 2.5% to 4.7%); prophylaxis to reduce this would be justifiable if the complications of such prophylaxis did not produce an alternative morbidity. The fatal PE rate after THR without routine chemical prophylaxis was low; a very large randomised clinical trial would be required to demonstrate directly whether any prophylactic measure could reduce this. There is a large discrepancy between the high DVT rate reported in clinical trials using universal screening venography and the symptomatic DVT rate shown in this study. We found insufficient evidence to recommend continuing thromboprophylaxis after discharge from hospital


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1458 - 1462
1 Nov 2015
Langlois J Atlan F Scemama C Courpied JP Hamadouche M

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component. . We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components. . A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed. . After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (. sd. 0.108): in the annealed group it was 0.1382 mm/year (. sd. 0.129) (Mann–Whitney U test, p < 0.001). No complication specific to either material was recorded. These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component. Cite this article: Bone Joint J 2015;97-B:1458–62


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 902 - 909
1 Aug 2019
Innmann MM Merle C Gotterbarm T Ewerbeck V Beaulé PE Grammatopoulos G

Aims

This study of patients with osteoarthritis (OA) of the hip aimed to: 1) characterize the contribution of the hip, spinopelvic complex, and lumbar spine when moving from the standing to the sitting position; 2) assess whether abnormal spinopelvic mobility is associated with worse symptoms; and 3) identify whether spinopelvic mobility can be predicted from static anatomical radiological parameters.

Patients and Methods

A total of 122 patients with end-stage OA of the hip awaiting total hip arthroplasty (THA) were prospectively studied. Patient-reported outcome measures (PROMs; Oxford Hip Score, Oswestry Disability Index, and Veterans RAND 12-Item Health Survey Score) and clinical data were collected. Sagittal spinopelvic mobility was calculated as the change from the standing to sitting position using the lumbar lordosis angle (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA), and acetabular anteinclination (AI) from lateral radiographs. The interaction of the different parameters was assessed. PROMs were compared between patients with normal spinopelvic mobility (10° ≤ ∆PT ≤ 30°) or abnormal spinopelvic mobility (stiff: ∆PT < ± 10°; hypermobile: ∆PT > ± 30°). Multiple regression and receiver operating characteristic (ROC) curve analyses were used to test for possible predictors of spinopelvic mobility.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 820 - 825
1 Jul 2022
Dhawan R Baré JV Shimmin A

Aims

Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA.

Methods

A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 307 - 311
1 Apr 2024
Horner D Hutchinson K Bretherton CP Griffin XL


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims

Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up.

Methods

We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 802 - 807
1 Aug 2024
Kennedy JW Sinnerton R Jeyakumar G Kane N Young D Meek RMD

Aims

The number of revision arthroplasties being performed in the elderly is expected to rise, including revision for infection. The primary aim of this study was to measure the treatment success rate for octogenarians undergoing revision total hip arthroplasty (THA) for periprosthetic joint infection (PJI) compared to a younger cohort. Secondary outcomes were complications and mortality.

Methods

Patients undergoing one- or two-stage revision of a primary THA for PJI between January 2008 and January 2021 were identified. Age, sex, BMI, American Society of Anesthesiologists grade, Charlson Comorbidity Index (CCI), McPherson systemic host grade, and causative organism were collated for all patients. PJI was classified as ‘confirmed’, ‘likely’, or ‘unlikely’ according to the 2021 European Bone and Joint Infection Society criteria. Primary outcomes were complications, reoperation, re-revision, and successful treatment of PJI. A total of 37 patients aged 80 years or older and 120 patients aged under 80 years were identified. The octogenarian group had a significantly lower BMI and significantly higher CCI and McPherson systemic host grades compared to the younger cohort.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims

The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant.

Methods

This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.