Advertisement for orthosearch.org.uk
Results 1 - 50 of 735
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research. Methods. A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review. Results. A total of 362 studies met the inclusion criteria. Most were of total elbow arthroplasty (246; 68%), followed by radial head arthroplasty (100; 28%), distal humeral hemiarthroplasty (11; 3%), and radiocapitellar arthroplasty (5; 1%). Most were retrospective (326; 90%) and observational (315; 87%). The median sample size for all types of implant across all studies was 36 (interquartile range (IQR) 21 to 75). The median length of follow-up for all studies was 56 months (IQR 36 to 81). A total of 583 unique outcome descriptors were used and were categorized into 18 domains. A total of 105 instruments were used to measure 39 outcomes. Conclusion. We found that most of the literature dealing with elbow arthroplasty consists of retrospective observational studies with small sample sizes and short follow-up. Many outcomes have been used with many different instruments for their measurement, indicating a need to define a core set of outcomes and instruments for future research in this area. Cite this article: Bone Joint J 2022;104-B(10):1148–1155


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 115 - 119
1 Jan 2011
Phillips S Biant LC

Orthopaedic surgeons use a variety of instruments to help correct, treat, and heal bone disease. The development of these instruments mirrors the history of orthopaedic surgery. The history of bonesetting, the treatment and replacement of joints, and of those who performed these techniques, appears to originate deep in antiquity. Changing ideas within medicine and surgery over the last 200 years have shaped the discovery and evolution of orthopaedic instruments and of the bonesetters themselves. Advances have led to the use of computers as instruments in the navigational guidance of arthroplasty surgery, the use of robotics, the development of cordless drills and improvements in the design of blades to cut bone. Yet some of the old instruments remain; plaster of Paris bandages, the Thomas Splint, Liston’s bonecutter, Gigli’s saw, bone nibblers and Macewan’s osteotomes are still in use. This paper presents a historical review of bonesetters and examines how orthopaedic instruments have evolved from antiquity to the 21st century


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 115 - 120
1 Jul 2019
Hooper J Schwarzkopf R Fernandez E Buckland A Werner J Einhorn T Walker PS

Aims. This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Materials and Methods. Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced. Results. Before and after steam sterilization, dimensional analysis showed that acrylonitrile butadiene styrene could not withstand the temperatures without dimensional changes. Oscillating saw tests with slotted cutting blocks produced debris, fractures, or further dimensional changes in the shape of Nylon-12 and polymethylmethacrylate (MED610), but polyetherimide ULTEM 1010 was least affected. Conclusion. The study showed that 3D-printed instrumentation was technically feasible and had some advantages. However, other factors, such as whether all procedural steps can be accomplished with a set of 3D-printed instruments, the logistics of delivery, and the economic aspects, require further study. Cite this article: Bone Joint J 2019;101-B(7 Supple C):115–120


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1039 - 1046
1 Sep 2022
Özdemir E Kuijpers MFL Visser J Schreurs BW Rijnen WHC

Aims. The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique. Methods. We updated the outcomes of our previous study, based on 208 consecutive revisions using IBG and the X-change femoral revision system in combination with a cemented polished stem, performed in our tertiary care institute between 1991 and 2007. Kaplan-Meier survival analyses were used to determine the survival rate of the revisions with endpoint revision for any reason and aseptic loosening. Secondary outcomes were radiological loosening and patient-reported outcome measures. Results. Mean age at revision total hip arthroplasty (THA) was 64.9 years (30 to 86). The most prevalent diagnosis for the femoral revision was aseptic loosening. At review in May 2021, 81 patients (85 hips) were still alive and 118 patients (120 hips; 58%) had died. Three patients (3 hips; 1%) were lost to follow-up at 11, 15, and 16 years after surgery, respectively. Data of all deceased and lost patients were included until final follow-up. The mean follow-up was 13.4 years (0 to 28). During the follow-up, 22 re-revisions were performed. The most common reason for re-revision was infection (n = 12; 54%). The survival with endpoint re-revision for any reason was 86% (95% confidence interval (CI) 79 to 91) at 20 years and 74% (95% CI 43 to 89) at 25 years after surgery. The survival for endpoint re-revision for aseptic loosening was 97% (95% CI 91 to 99) after both 20 and 25 years. Conclusion. We conclude that femoral IBG is a valuable technique that can reconstitute femoral bone loss in the long term. After 25 years of follow-up, few re-revisions for aseptic loosening were required. Also, the overall revision rate is very acceptable at a long follow-up. This technique is especially attractive for younger patients facing femoral revisions with extensive bone loss. Cite this article: Bone Joint J 2022;104-B(9):1039–1046


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 627 - 634
1 Apr 2021
Sabah SA Alvand A Beard DJ Price AJ

Aims. To estimate the measurement properties for the Oxford Knee Score (OKS) in patients undergoing revision knee arthroplasty (responsiveness, minimal detectable change (MDC-90), minimal important change (MIC), minimal important difference (MID), internal consistency, construct validity, and interpretability). Methods. Secondary data analysis was performed for 10,727 patients undergoing revision knee arthroplasty between 2013 to 2019 using a UK national patient-reported outcome measure (PROM) dataset. Outcome data were collected before revision and at six months postoperatively, using the OKS and EuroQol five-dimension score (EQ-5D). Measurement properties were assessed according to COnsensus-based Standards for the selection of health status Measurement Instruments (COSMIN) guidelines. Results. A total of 9,219 patients had complete outcome data. Mean preoperative OKS was 16.7 points (SD 8.1), mean postoperative OKS 29.1 (SD 11.4), and mean change in OKS + 12.5 (SD 10.7). Median preoperative EQ-5D index was 0.260 (interquartile range (IQR) 0.055 to 0.691), median postoperative EQ-5D index 0.691 (IQR 0.516 to 0.796), and median change in EQ-5D index + 0.240 (IQR 0.000 to 0.567). Internal consistency was good with Cronbach’s α 0.88 (baseline) and 0.94 (post-revision). Construct validity found a high correlation of OKS total score with EQ-5D index (r = 0.76 (baseline), r = 0.83 (post-revision), p < 0.001). The OKS was responsive with standardized effect size (SES) 1.54 (95% confidence interval (CI) 1.51 to 1.57), compared to SES 0.83 (0.81 to 0.86) for the EQ-5D index. The MIC for the OKS was 7.5 points (95% CI 5.5 to 8.5) based on the optimal cut-off with specificity 0.72, sensitivity 0.60, and area under the curve 0.66. The MID for the OKS was 5.2 points. The MDC-90 was 3.9 points. The OKS did not demonstrate significant floor or ceiling effects. Conclusion. This study found that the OKS was a useful and valid instrument for assessment of outcome following revision knee arthroplasty. The OKS was responsive to change and demonstrated good measurement properties. Cite this article: Bone Joint J 2021;103-B(4):627–634


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 261 - 267
1 Feb 2020
Tøndevold N Lastikka M Andersen T Gehrchen M Helenius I

Aims. It is uncertain whether instrumented spinal fixation in nonambulatory children with neuromuscular scoliosis should finish at L5 or be extended to the pelvis. Pelvic fixation has been shown to be associated with up to 30% complication rates, but is regarded by some as the standard for correction of deformity in these conditions. The incidence of failure when comparing the most caudal level of instrumentation, either L5 or the pelvis, using all-pedicle screw instrumentation has not previously been reported. In this retrospective study, we compared nonambulatory patients undergoing surgery at two centres: one that routinely instrumented to L5 and the other to the pelvis. Methods. In all, 91 nonambulatory patients with neuromuscular scoliosis were included. All underwent surgery using bilateral, segmental, pedicle screw instrumentation. A total of 40 patients underwent fusion to L5 and 51 had their fixation extended to the pelvis. The two groups were assessed for differences in terms of clinical and radiological findings, as well as complications. Results. The main curve (MC) was a mean of 90° (40° to 141°) preoperatively and 46° (15° to 82°) at two-year follow-up in the L5 group, and 82° (33° to 116°) and 19° (1° to 60°) in the pelvic group (p < 0.001 at follow-up). Correction of MC and pelvic obliquity (POB) were statistically greater in the pelvic group (p < 0.001). There was no statistically significant difference in the operating time, blood loss, or complications. Loss of MC correction (> 10°) was more common in patients fixated to the pelvis (23% vs 3%; p = 0.032), while loss of pelvic obliquity correction was more frequent in the L5 group (25% vs 0%; p = 0.007). Risk factors for loss of correction (either POB or MC) included preoperative coronal imbalance (> 50 mm, odds ratio (OR) 11.5, 95%confidence interval (CI) 2.0 to 65; p = 0.006) and postoperative sagittal imbalance (> 25 mm, OR 11.0, 95% CI1.9 to 65; p = 0.008). Conclusion. We found that patients undergoing pelvic fixation had a greater correction of MC and POB. The rate of complications was not different. Preoperative coronal and postoperative sagittal imbalance were associated with increased risks of loss of correction, regardless of extent of fixation. Therefore, we recommend pelvic fixation in all nonambulatory children with neuromuscular scoliosis where coronal or sagittal imbalance are present preoperatively. Cite this article: Bone Joint J 2020;102-B(2):261–267


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 102 - 108
1 Jan 2016
Kang C Kim C Moon J

Aims. The aims of this study were to evaluate the clinical and radiological outcomes of instrumented posterolateral fusion (PLF) performed in patients with rheumatoid arthritis (RA). . Methods. A total of 40 patients with RA and 134 patients without RA underwent instrumented PLF for spinal stenosis between January 2003 and December 2011. The two groups were matched for age, gender, bone mineral density, the history of smoking and diabetes, and number of fusion segments. . The clinical outcomes measures included the visual analogue scale (VAS) and the Korean Oswestry Disability Index (KODI), scored before surgery, one year and two years after surgery. Radiological outcomes were evaluated for problems of fixation, nonunion, and adjacent segment disease (ASD). The mean follow-up was 36.4 months in the RA group and 39.1 months in the non-RA group. Results. Both groups had significant improvement in symptoms one year after surgery, while the RA group showed some deterioration of outcome scores owing to complications during the second year after surgery. Complications occurred at a higher rate in the group with RA (19 patients, 47.5%) than in those without RA (23 patients, 17.1%) (p < 0.001). A total of 15 patients in the RA group (37.5%) required revision surgery, mainly for implant failure and post-operative infection. . Discussion. Multimodal approaches should be considered when performing instrumented PLF in patients with RA to reduce the rate of complications, such as problems of fixation, post-operative infection and nonunion. Take home message: Specific strategies should be undertaken in order to optimise outcomes in patients with rheumatoid arthritis. Cite this article: Bone Joint J 2016;98-B:102–8


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 939 - 944
1 Jul 2016
Boonen B Schotanus MGM Kerens B van der Weegen W Hoekstra HJ Kort NP

Aims. We wished to compare the clinical outcome, as assessed by questionnaires and the rate of complications, in total knee arthroplasty (TKA) undertaken with patient-matched positioning guides (PMPGs) or conventional instruments. Patients and Methods. A total of 180 patients (74 men, 106 women; mean age 67 years) were included in a multicentre, adequately powered, double-blind, randomised controlled trial. The mean follow-up was 44 months (24 to 57). Results. There were no significant or clinically relevant differences between the two groups for all outcome measures (Knee Society Score, p = 0.807; Oxford Knee Score, p = 0.304; Western Ontario and McMaster osteoarthritis index, p = 0.753; visual analogue scale for pain, p = 0.227; EuroQol-5D-3L index score, p = 0.610; EuroQol-5D-3L VAS health, p = 0.968.) There was no difference in the rate of complications (p = 0.291). . Conclusion. PMPGs are already in relatively common use and their short-term clinical results are equal to conventional instrumented TKA. Cite this article: Bone Joint J 2016;98-B:939–44


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims

The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA).

Methods

A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1125 - 1129
1 Nov 2001
Dawson J Fitzpatrick R Frost S Gundle R McLardy-Smith P Murray D

The Oxford hip score (OHS) is a patient-based instrument for assessment of outcome which is often used after total hip replacement, and the EuroQol 5D (EQ5D) is a patient-based generic questionnaire for health assessment. In an analysis of the outcome at one year of 609 revision hip replacements (RHRs), we compared the OHS and EQ5D scores, postoperative patient satisfaction and change in pain. About 25% of the operations were repeat RHRs. At one year, 57% of patients were very pleased with their operation. The correlation between preoperative and postoperative scores and change scores for the OHS and EQ5D was high. For both instruments the effect sizes were large, but the greater effect size of the OHS suggests that it is particularly sensitive to improvements after RHR. The effect scores of the OHS declined with the number of previous RHRs, while those for the EQ5D seemed less sensitive. Our results confirm the value of the OHS in assessing outcome after RHR


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 201 - 204
1 Feb 2005
Schaeren S Bischoff-Ferrari HA Knupp M Dick W Huber JF Theiler R

We validated the North American Spine Society (NASS) outcome-assessment instrument for the lumbar spine in a computerised touch-screen format and assessed patients’ acceptance, taking into account previous computer experience, age and gender. Fifty consecutive patients with symptomatic and radiologically-proven degenerative disease of the lumbar spine completed both the hard copy (paper) and the computerised versions of the NASS questionnaire. Statistical analysis showed high agreement between the paper and the touch-screen computer format for both subscales (intraclass correlation coefficient 0.94, 95% confidence interval (0.90 to 0.97)) independent of computer experience, age and gender. In total, 55% of patients stated that the computer format was easier to use and 66% preferred it to the paper version (p < 0.0001 among subjects expressing a preference). Our data indicate that the touch-screen format is comparable to the paper form. It may improve follow-up in clinical practice and research by meeting patients’ preferences and minimising administrative work


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 146 - 150
1 Feb 2013
Sheibani-Rad S Wolfe S Jupiter J

Like athletes, musicians are vulnerable to musculoskeletal injuries that can be career ending or have a severe negative financial impact. All ages are affected, with a peak incidence in the third and fourth decades. Women are slightly more likely to be affected than men. It is incumbent upon orthopaedic surgeons to be able to complete a thorough physical assessment, be aware of the risk factors associated with musculoskeletal symptoms in musicians, and have a detailed knowledge of the specific syndromes they suffer and their appropriate treatment.

In this paper we review the common hand injuries that afflict musicians and discuss their treatment.

Cite this article: Bone Joint J 2013;95-B:146–50.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1411 - 1416
1 Oct 2015
Li Y Yang S Chen H Kao Y Tu Y

We evaluated the impact of lumbar instrumented circumferential fusion on the development of adjacent level vertebral compression fractures (VCFs). Instrumented posterior lumbar interbody fusion (PLIF) has become a popular procedure for degenerative lumbar spine disease. The immediate rigidity produced by PLIF may cause more stress and lead to greater risk of adjacent VCFs. However, few studies have investigated the relationship between PLIF and the development of subsequent adjacent level VCFs.

Between January 2005 and December 2009, a total of 1936 patients were enrolled. Of these 224 patients had a new VCF and the incidence was statistically analysed with other covariants. In total 150 (11.1%) of 1348 patients developed new VCFs with PLIF, with 108 (72%) cases at adjacent segment. Of 588 patients, 74 (12.5%) developed new subsequent VCFs with conventional posterolateral fusion (PLF), with 37 (50%) patients at an adjacent level. Short-segment fusion, female and age older than 65 years also increased the development of new adjacent VCFs in patients undergoing PLIF. In the osteoporotic patient, more rigid fusion and a higher stress gradient after PLIF will cause a higher adjacent VCF rate.

Cite this article: Bone Joint J 2015;97-B:1411–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans.

Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 447 - 448
1 May 1973
Hadfield G


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1121 - 1126
1 Aug 2013
Núñez-Pereira S Pellisé F Rodríguez-Pardo D Pigrau C Bagó J Villanueva C Cáceres E

This study evaluates the long-term survival of spinal implants after surgical site infection (SSI) and the risk factors associated with treatment failure.

A Kaplan-Meier survival analysis was carried out on 43 patients who had undergone a posterior spinal fusion with instrumentation between January 2006 and December 2008, and who consecutively developed an acute deep surgical site infection. All were appropriately treated by surgical debridement with a tailored antibiotic program based on culture results for a minimum of eight weeks.

A ‘terminal event’ or failure of treatment was defined as implant removal or death related to the SSI. The mean follow-up was 26 months (1.03 to 50.9). A total of ten patients (23.3%) had a terminal event. The rate of survival after the first debridement was 90.7% (95% confidence interval (CI) 82.95 to 98.24) at six months, 85.4% (95% CI 74.64 to 96.18) at one year, and 73.2% (95% CI 58.70 to 87.78) at two, three and four years. Four of nine patients required re-instrumentation after implant removal, and two of the four had a recurrent infection at the surgical site. There was one recurrence after implant removal without re-instrumentation.

Multivariate analysis revealed a significant risk of treatment failure in patients who developed sepsis (hazard ratio (HR) 12.5 (95% confidence interval (CI) 2.6 to 59.9); p < 0.001) or who had > three fused segments (HR 4.5 (95% CI 1.25 to 24.05); p = 0.03). Implant survival is seriously compromised even after properly treated surgical site infection, but progressively decreases over the first 24 months.

Cite this article: Bone Joint J 2013;95-B:1121–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1547 - 1547
1 Nov 2006
Laurence M


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 602 - 609
1 Jun 2023
Mistry D Ahmed U Aujla R Aslam N D’Alessandro P Malik S

Aims. In the UK, the agricultural, military, and construction sectors have stringent rules about the use of hearing protection due to the risk of noise-induced hearing loss. Orthopaedic staff may also be at risk due to the use of power tools. The UK Health and Safety Executive (HSE) have clear standards as to what are deemed acceptable occupational levels of noise on A-weighted and C-weighted scales. The aims of this review were to assess the current evidence on the testing of exposure to noise in orthopaedic operating theatres to see if it exceeds these regulations. Methods. A search of PubMed and EMBASE databases was conducted using PRISMA guidelines. The review was registered prospectively in PROSPERO. Studies which assessed the exposure to noise for orthopaedic staff in operating theatres were included. Data about the exposure to noise were extracted from these studies and compared with the A-weighted and C-weighted acceptable levels described in the HSE regulations. Results. A total of 15 studies were deemed eligible. These included a total of 386 orthopaedic operations and the use of 64 orthopaedic instruments. A total of 294 operations (76%) and 45 instruments (70%) exceeded the regulations on an A-weighted scale, and 22% (10 of 46) of operations exceeded the maximum C-weighted peak acceptable level of noise. Noise-induced hearing loss was reported in 28 of 55 orthopaedic staff members (50.9%). Conclusion. Safe levels of noise can be exceeded in orthopaedic operations, and when using orthopaedic instruments. Employers have clear policies about exposure to noise in the workplace but have yet to identify orthopaedic theatres as a potential at-risk area. Orthopaedic staff need education, monitoring, and protection, while employers should consider regular assessments of staff in orthopaedic theatres and offer methods to prevent noise-induced hearing loss. Cite this article: Bone Joint J 2023;105-B(6):602–609


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1342 - 1347
1 Nov 2024
Onafowokan OO Jankowski PP Das A Lafage R Smith JS Shaffrey CI Lafage V Passias PG

Aims. The aim of this study was to investigate the impact of the level of upper instrumented vertebra (UIV) in frail patients undergoing surgery for adult spine deformity (ASD). Methods. Patients with adult spinal deformity who had undergone T9-to-pelvis fusion were stratified using the ASD-Modified Frailty Index into not frail, frail, and severely frail categories. ASD was defined as at least one of: scoliosis ≥ 20°, sagittal vertical axis (SVA) ≥ 5 cm, or pelvic tilt ≥ 25°. Means comparisons tests were used to assess differences between both groups. Logistic regression analyses were used to analyze associations between frailty categories, UIV, and outcomes. Results. A total of 477 patients were included (mean age 60.3 years (SD 14.9), mean BMI 27.5 kg/m. 2. (SD 5.8), mean Charlson Comorbidity Index (CCI) 1.67 (SD 1.66)). Overall, 74% of patients were female (n = 353), and 49.6% of patients were not frail (237), 35.4% frail (n = 169), and 15% severely frail (n = 71). At baseline, differences in age, BMI, CCI, and deformity were significant (all p = 0.001). Overall, 15.5% of patients (n = 74) had experienced mechanical complications by two years (8.1% not frail (n = 36), 15.1% frail (n = 26), and 16.3% severely frail (n = 12); p = 0.013). Reoperations also differed between groups (20.2% (n = 48) vs 23.3% (n = 39) vs 32.6% (n = 23); p = 0.011). Controlling for osteoporosis, baseline deformity, and degree of correction (by sagittal age-adjusted score (SAAS) matching), frail and severely frail patients were more likely to experience mechanical complications if they had heart failure (odds ratio (OR) 6.6 (95% CI 1.6 to 26.7); p = 0.008), depression (OR 5.1 (95% CI 1.1 to 25.7); p = 0.048), or cancer (OR 1.5 (95% CI 1.1 to 1.4); p = 0.004). Frail and severely frail patients experienced higher rates of mechanical complication than ‘not frail’ patients at two years (19% (n = 45) vs 11.9% (n = 29); p = 0.003). When controlling for baseline deformity and degree of correction in severely frail and frail patients, severely frail patients were less likely to experience clinically relevant proximal junctional kyphosis or failure or mechanical complications by two years, if they had a more proximal UIV. Conclusion. Frail patients are at risk of a poor outcome after surgery for adult spinal deformity due to their comorbidities. Although a definitively prescriptive upper instrumented vertebra remains elusive, these patients appear to be at greater risk for a poor outcome if the upper instrumented vertebra is sited more distally. Cite this article: Bone Joint J 2024;106-B(11):1342–1347


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 887 - 891
1 Sep 2024
Whyte W Thomas AM

The critical relationship between airborne microbiological contamination in an operating theatre and surgical site infection (SSI) is well known. The aim of this annotation is to explain the scientific basis of using settle plates to audit the quality of air, and to provide information about the practicalities of using them for the purposes of clinical audit. The microbiological quality of the air in most guidance is defined by volumetric sampling, but this method is difficult for surgical departments to use on a routine basis. Settle plate sampling, which mimics the mechanism of deposition of airborne microbes onto open wounds and sterile instruments, is a good alternative method of assessing the quality of the air. Current practice is not to sample the air in an operating theatre during surgery, but to rely on testing the engineering systems which deliver the clean air. This is, however, not good practice and microbiological testing should be carried out routinely during operations as part of clinical audit. Cite this article: Bone Joint J 2024;106-B(9):887–891


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1039 - 1043
1 Oct 2024
Luo TD Kayani B Magan A Haddad FS

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team’s overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise. Cite this article: Bone Joint J 2024;106-B(10):1039–1043


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 114 - 120
1 Feb 2024
Khatri C Metcalfe A Wall P Underwood M Haddad FS Davis ET

Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies. Cite this article: Bone Joint J 2024;106-B(2):114–120


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 764 - 774
1 Aug 2024
Rivera RJ Karasavvidis T Pagan C Haffner R Ast MP Vigdorchik JM Debbi EM

Aims. Conventional patient-reported surveys, used for patients undergoing total hip arthroplasty (THA), are limited by subjectivity and recall bias. Objective functional evaluation, such as gait analysis, to delineate a patient’s functional capacity and customize surgical interventions, may address these shortcomings. This systematic review endeavours to investigate the application of objective functional assessments in appraising individuals undergoing THA. Methods. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied. Eligible studies of THA patients that conducted at least one type of objective functional assessment both pre- and postoperatively were identified through Embase, Medline/PubMed, and Cochrane Central database-searching from inception to 15 September 2023. The assessments included were subgrouped for analysis: gait analysis, motion analysis, wearables, and strength tests. Results. A total of 130 studies using 15 distinct objective functional assessment methods (FAMs) were identified. The most frequently used method was instrumented gait/motion analysis, followed by the Timed-Up-and-Go test (TUG), 6 minute walk test, timed stair climbing test, and various strength tests. These assessments were characterized by their diagnostic precision and applicability to daily activities. Wearables were frequently used, offering cost-effectiveness and remote monitoring benefits. However, their accuracy and potential discomfort for patients must be considered. Conclusion. The integration of objective functional assessments in THA presents promise as a progress-tracking modality for improving patient outcomes. Gait analysis and the TUG, along with advancing wearable sensor technology, have the potential to enhance patient care, surgical planning, and rehabilitation. Cite this article: Bone Joint J 2024;106-B(8):764–774


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1011 - 1016
1 Sep 2022
Acem I van de Sande MAJ

Prediction tools are instruments which are commonly used to estimate the prognosis in oncology and facilitate clinical decision-making in a more personalized manner. Their popularity is shown by the increasing numbers of prediction tools, which have been described in the medical literature. Many of these tools have been shown to be useful in the field of soft-tissue sarcoma of the extremities (eSTS). In this annotation, we aim to provide an overview of the available prediction tools for eSTS, provide an approach for clinicians to evaluate the performance and usefulness of the available tools for their own patients, and discuss their possible applications in the management of patients with an eSTS. Cite this article: Bone Joint J 2022;104-B(9):1011–1016


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1306 - 1311
1 Nov 2024
Watts AC McDaid C Hewitt C

Aims. A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement. Methods. A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings. Results. A total of 45 respondents completed the survey. Nine core mandatory domains were identified: ‘return to work or normal daily role’; delivery of care was measured in the domains ‘patient satisfaction with the outcome of surgery’ and ‘would the patient have the same operation again’; ‘pain’; ‘revision’; ‘elbow function’; ‘independence in activities of daily living’; ‘health-related quality of life’; and ‘adverse events’. ‘Elbow range of motion’ was identified as important by consensus but was felt to be less relevant by the PPIE panel. The PPIE panel unanimously stated that pain should be used as the primary outcome domain. Conclusion. This study defined core domains for the clinical outcomes of elbow replacement obtained by consensus from patients, carers, and healthcare professionals. Pain may be used as the primary outcome in future studies, where appropriate. Further work is required to define the instruments that should be used. Cite this article: Bone Joint J 2024;106-B(11):xxx–xxx


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 166 - 171
1 Feb 2023
Ragborg LC Dragsted C Ohrt-Nissen S Andersen T Gehrchen M Dahl B

Aims. Only a few studies have investigated the long-term health-related quality of life (HRQoL) in patients with an idiopathic scoliosis. The aim of this study was to investigate the overall HRQoL and employment status of patients with an idiopathic scoliosis 40 years after diagnosis, to compare it with that of the normal population, and to identify possible predictors for a better long-term HRQoL. Methods. We reviewed the full medical records and radiological reports of patients referred to our hospital with a scoliosis of childhood between April 1972 and April 1982. Of 129 eligible patients with a juvenile or adolescent idiopathic scoliosis, 91 took part in the study (71%). They were evaluated with full-spine radiographs and HRQoL questionnaires and compared with normative data. We compared the HRQoL between observation (n = 27), bracing (n = 46), and surgical treatment (n = 18), and between thoracic and thoracolumbar/lumbar (TL/L) curves. Results. The mean time to follow-up was 40.8 years (SD 2.6) and the mean age of patients was 54.0 years (SD 2.7). Of the 91 patients, 86 were female (95%) and 51 had a main thoracic curve (53%). We found a significantly lower HRQoL measured on all the Scoliosis Research Society 22r instrument (SRS-22r) subdomains (p < 0.001) with the exception of mental health, than in an age-matched normal population. Incapacity to work was more prevalent in scoliosis patients (21%) than in the normal population (11%). The median SRS-22r subscore was 4.0 (interquartile range (IQR) 3.3 to 4.4) for TL/L curves and 4.1 (IQR 3.8 to 4.4) for thoracic curves (p = 0.300). We found a significantly lower self-image score for braced (median 3.6 (IQR 3.0 to 4.0)) and surgically treated patients (median 3.6 (IQR 3.2 to 4.3)) than for those treated by observation (median 4.0 (IQR 4.1 to 4.8); p = 0.010), but no statistically significant differences were found for the remaining subdomains. Conclusion. In this long-term follow-up study, we found a significantly decreased HRQoL and capacity to work in patients with an idiopathic scoliosis 40 years after diagnosis. Cite this article: Bone Joint J 2023;105-B(2):166–171


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 713 - 719
1 Jul 2024
Patel MS Shah S Elkazaz MK Shafafy M Grevitt MP

Aims. Historically, patients undergoing surgery for adolescent idiopathic scoliosis (AIS) have been nursed postoperatively in a critical care (CC) setting because of the challenges posed by prone positioning, extensive exposures, prolonged operating times, significant blood loss, major intraoperative fluid shifts, cardiopulmonary complications, and difficulty in postoperative pain management. The primary aim of this paper was to determine whether a scoring system, which uses Cobb angle, forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and number of levels to be fused, is a valid method of predicting the need for postoperative critical care in AIS patients who are to undergo scoliosis correction with posterior spinal fusion (PSF). Methods. We retrospectively reviewed all AIS patients who had undergone PSF between January 2018 and January 2020 in a specialist tertiary spinal referral centre. All patients were assessed preoperatively in an anaesthetic clinic. Postoperative care was defined as ward-based (WB) or critical care (CC), based on the preoperative FEV1, FVC, major curve Cobb angle, and the planned number of instrumented levels. Results. Overall, 105 patients were enrolled. Their mean age was 15.5 years (11 to 25) with a mean weight of 55 kg (35 to 103). The mean Cobb angle was 68° (38° to 122°). Of these, 38 patients were preoperatively scored to receive postoperative CC. However, only 19% of the cohort (20/105) actually needed CC-level support. Based on these figures, and an average paediatric intensive care unit stay of one day before stepdown to ward-based care, the potential cost-saving on the first postoperative night for this cohort was over £20,000. There was no statistically significant difference between the Total Pathway Score (TPS), the numerical representation of the four factors being assessed, and the actual level of care received (p = 0.052) or the American Society of Anesthesiologists grade (p = 0.187). Binary logistic regression analysis of the TPS variables showed that the preoperative Cobb angle was the only variable which significantly predicted the need for critical care. Conclusion. Most patients undergoing posterior fusion surgery for AIS do not need critical care. Of the readily available preoperative measures, the Cobb angle is the only predictor of the need for higher levels of care, and has a threshold value of 74.5°. Cite this article: Bone Joint J 2024;106-B(7):713–719


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 394 - 400
1 Apr 2024
Kjærvik C Gjertsen J Stensland E Dybvik EH Soereide O

Aims. The aims of this study were to assess quality of life after hip fractures, to characterize respondents to patient-reported outcome measures (PROMs), and to describe the recovery trajectory of hip fracture patients. Methods. Data on 35,206 hip fractures (2014 to 2018; 67.2% female) in the Norwegian Hip Fracture Register were linked to data from the Norwegian Patient Registry and Statistics Norway. PROMs data were collected using the EuroQol five-dimension three-level questionnaire (EQ-5D-3L) scoring instrument and living patients were invited to respond at four, 12, and 36 months post fracture. Multiple imputation procedures were performed as a model to substitute missing PROM data. Differences in response rates between categories of covariates were analyzed using chi-squared test statistics. The association between patient and socioeconomic characteristics and the reported EQ-5D-3L scores was analyzed using linear regression. Results. The median age was 83 years (interquartile range 76 to 90), and 3,561 (10%) lived in a healthcare facility. Observed mean pre-fracture EQ-5D-3L index score was 0.81 (95% confidence interval 0.803 to 0.810), which decreased to 0.66 at four months, to 0.70 at 12 months, and to 0.73 at 36 months. In the imputed datasets, the reduction from pre-fracture was similar (0.15 points) but an improvement up to 36 months was modest (0.01 to 0.03 points). Patients with higher age, male sex, severe comorbidity, cognitive impairment, lower income, lower education, and those in residential care facilities had a lower proportion of respondents, and systematically reported a lower health-related quality of life (HRQoL). The response pattern of patients influenced scores significantly, and the highest scores are found in patients reporting scores at all observation times. Conclusion. Hip fracture leads to a persistent reduction in measured HRQoL, up to 36 months. The patients’ health and socioeconomic status were associated with the proportion of patients returning PROM data for analysis, and affected the results reported. Observed EQ-5D-3L scores are affected by attrition and selection bias mechanisms and motivate the use of statistical modelling for adjustment. Cite this article: Bone Joint J 2024;106-B(4):394–400


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1176 - 1181
1 Oct 2024
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Nietosvaara Y Helenius I

Aims. Closed suction subfascial drainage is widely used after instrumented posterior spinal fusion in patients with a spinal deformity. The aim of this study was to determine the effect of this wound drainage on the outcomes in patients with adolescent idiopathic scoliosis (AIS). This was a further analysis of a randomized, multicentre clinical trial reporting on patients after posterior spinal fusion using segmental pedicle screw instrumentation. In this study the incidence of deep surgical site infection (SSI) and chronic postoperative pain at two years’ follow-up are reported. Methods. We conducted a randomized, multicentre clinical trial on adolescents undergoing posterior spinal fusion for AIS using segmental pedicle screw instrumentation. A total of 90 consecutive patients were randomized into a ‘drain’ or ‘no drain’ group at the time of wound closure, using the sealed envelope technique (1:1). The primary outcomes in the initial study were the change in the level of haemoglobin in the blood postoperatively and total blood loss. A secondary outcome was the opioid consumption immediately after surgery. The aim of this further study was to report the rate of deep SSI and persistent postoperative pain, at two years' follow-up. Results. As previously reported, the mean 48-hour opioid consumption was significantly higher in the no drain group (2.0 mg/kg (SD 0.8) vs 1.4 mg/kg (SD 0.7); p = 0.005). There were no delayed deep SSIs. At two years’ follow-up, the mean Scoliosis Research Society 24-item questionnaire (SRS-24) total score did not differ between the groups (4.11 (SD 0.47) vs 4.16 (SD 0.33); p = 0.910). The mean SRS-24 pain score was 4.28 (SD 0.48) in the no drain group compared with 4.33 (SD 0.66) in the drain group (p = 0.245). Seven patients (19%) in the no drain group and six in the drain group (14%) reported moderate to severe pain (numerical rating scale ≥ 4) at two years’ follow-up (p = 0.484). The general self-image domain score was significantly higher in the no drain group compared with the drain group (4.02 (SD 0.74) vs 4.59 (SD 0.54); p < 0.001). Conclusion. The main finding in this study was that more severe pain immediately after surgery did not result in a higher incidence of chronic pain in the no drain group compared with the drain group. Back pain and health-related quality of life at two years’ follow-up did not differ between the groups. The patient-reported self-image domain was significantly better in the no drain group compared with the drain group. Cite this article: Bone Joint J 2024;106-B(10):1176–1181


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 75 - 82
1 Jan 2019
Kim J Lee SY Jung JH Kim SW Oh J Park MS Chang H Kim T

Aims. The aim of this study was to evaluate the outcome of spinal instrumentation in haemodialyzed patients with native pyogenic spondylodiscitis. Spinal instrumentation in these patients can be dangerous due to rates of complications and mortality, and biofilm formation on the instrumentation. Patients and Methods. A total of 134 haemodialyzed patients aged more than 50 years who underwent surgical treatment for pyogenic spondylodiscitis were included in the study. Their mean age was 66.4 years (50 to 83); 66 were male (49.3%) and 68 were female (50.7%). They were divided into two groups according to whether spinal instrumentation was used or not. Propensity score matching was used to attenuate the potential selection bias. The outcome of treatment was compared between these two groups. Results. A total of 89 patients (66.4%) underwent non-instrumented surgery and 45 (33.5%) underwent instrumented surgery. There were no significant differences in the rates of postoperative complications, except for an increased rate of wound problems in the instrumented group, which was found in the unmatched cohorts (p = 0.034). There were no significant differences in the rate of recurrent infections (p = 0.328 for the unmatched cohort; p = 0.269 for the matched cohort) and mortality rate, including in-hospital (p = 0.713 for the unmatched cohort; p = 0.738 for the matched cohort) and one-year rates (p = 0.363 for the unmatched cohort; p = 0.787 for the matched cohort), between the groups. However, the interval between the initial diagnosis and the first recurrence was significantly longer in the instrumented group (p = 0.008 for the unmatched cohort; p = 0.032 for the matched cohort). Conclusion. Instrumented surgery for haemodialyzed patients with pyogenic spondylodiscitis showed similar outcomes, including recurrence and mortality, to non-instrumented surgery, despite the instrumented group having more severe neurological deficit, a larger number of involved levels, and increased kyphotic angle


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 513 - 518
1 Apr 2020
Hershkovich O D’Souza A Rushton PRP Onosi IS Yoon WW Grevitt MP

Aims. Significant correction of an adolescent idiopathic scoliosis in the coronal plane through a posterior approach is associated with hypokyphosis. Factors such as the magnitude of the preoperative coronal curve, the use of hooks, number of levels fused, preoperative kyphosis, screw density, and rod type have all been implicated. Maintaining the normal thoracic kyphosis is important as hypokyphosis is associated with proximal junctional failure (PJF) and early onset degeneration of the spine. The aim of this study was to determine if coronal correction per se was the most relevant factor in generating hypokyphosis. Methods. A total of 95 patients (87% female) with a median age of 14 years were included in our study. Pre- and postoperative radiographs were measured and the operative data including upper instrumented vertebra (UIV), lower instrumented vertebra (LIV), metal density, and thoracic flexibility noted. Further analysis of the post-surgical coronal outcome (group 1 < 60% correction and group 2 ≥ 60%) were studied for their association with the postoperative kyphosis in the sagittal plane using univariate and multivariate logistic regression. Results. Of the 95 patients, 71.6% (68) had a thoracic correction of > 60%. Most (97.8%) had metal density < 80%, while thoracic flexibility > 50% was found in 30.5% (29). Preoperative hypokyphosis (< 20°) was present in 25.3%. A postoperative thoracic hypokyphosis was four times more likely to occur in patients with thoracic correction ≥ 60% (odds ratio (OR) 4.08; p = 0.005), after adjusting for confounding variables. This association was not affected by metal density, thoracic flexibility, LIV, UIV, age, or sex. Conclusion. Our study supports the ‘essential lordosis’ hypothesis of Roaf and Dickson, i.e. with a greater ability to translate the apical vertebra towards the midline, there is a commensurate lengthening of the anterior column due to the vertebral wedging. Cite this article: Bone Joint J 2020;102-B(4):513–518


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 963 - 971
1 Aug 2022
Sun Z Liu W Liu H Li J Hu Y Tu B Wang W Fan C

Aims. Heterotopic ossification (HO) is a common complication after elbow trauma and can cause severe upper limb disability. Although multiple prognostic factors have been reported to be associated with the development of post-traumatic HO, no model has yet been able to combine these predictors more succinctly to convey prognostic information and medical measures to patients. Therefore, this study aimed to identify prognostic factors leading to the formation of HO after surgery for elbow trauma, and to establish and validate a nomogram to predict the probability of HO formation in such particular injuries. Methods. This multicentre case-control study comprised 200 patients with post-traumatic elbow HO and 229 patients who had elbow trauma but without HO formation between July 2019 and December 2020. Features possibly associated with HO formation were obtained. The least absolute shrinkage and selection operator regression model was used to optimize feature selection. Multivariable logistic regression analysis was applied to build the new nomogram: the Shanghai post-Traumatic Elbow Heterotopic Ossification Prediction model (STEHOP). STEHOP was validated by concordance index (C-index) and calibration plot. Internal validation was conducted using bootstrapping validation. Results. Male sex, obesity, open wound, dislocations, late definitive surgical treatment, and lack of use of non-steroidal anti-inflammatory drugs were identified as adverse predictors and incorporated to construct the STEHOP model. It displayed good discrimination with a C-index of 0.80 (95% confidence interval 0.75 to 0.84). A high C-index value of 0.77 could still be reached in the internal validation. The calibration plot showed good agreement between nomogram prediction and observed outcomes. Conclusion. The newly developed STEHOP model is a valid and convenient instrument to predict HO formation after surgery for elbow trauma. It could assist clinicians in counselling patients regarding treatment expectations and therapeutic choices. Cite this article: Bone Joint J 2022;104-B(8):963–971


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 74 - 80
1 Jun 2021
Deckey DG Rosenow CS Verhey JT Brinkman JC Mayfield CK Clarke HD Bingham JS

Aims. Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. Methods. A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed. Results. In all, 103 M-TKAs and 96 RA-TKAs were included. In RA-TKA versus M-TKA, respectively: mean femoral positioning (0.9° (SD 1.2°) vs 1.7° (SD 1.1°)), mean tibial positioning (0.3° (SD 0.9°) vs 1.3° (SD 1.0°)), mean posterior tibial slope (-0.3° (SD 1.3°) vs 1.7° (SD 1.1°)), and mean mechanical axis limb alignment (1.0° (SD 1.7°) vs 2.7° (SD 1.9°)) all deviated significantly less from the plan (all p < 0.001); significantly fewer knees required a distal femoral recut (10 (10%) vs 22 (22%), p = 0.033); and deviation from planned polyethylene thickness was significantly less (1.4 mm (SD 1.6) vs 2.7 mm (SD 2.2), p < 0.001). Conclusion. RA-TKA is significantly more accurate and precise in planning both component positioning and final polyethylene insert thickness. Future studies should investigate whether this increased accuracy and precision has an impact on clinical outcomes. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed and can be further individualized to the patient. Cite this article: Bone Joint J 2021;103-B(6 Supple A):74–80


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 536 - 541
1 Mar 2021
Ferlic PW Hauser L Götzen M Lindtner RA Fischler S Krismer M

Aims. The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques. Methods. We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients’ charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded. Results. The number of implants (14.5 vs 17.1) and the implant density (1.5 vs 1.9) were significantly lower in Group 2 (p < 0.001). Operating time was 27 minutes shorter in Group 2 than in Group 1, with a mean of 217 minutes (SD 50.5; 120 to 346). The duration of surgery per instrumented vertebra was reduced by 19% in Group 2 (p = 0.011). No statistical difference was found in the postoperative Cobb angle, vertebral rotation, the relative correction achieved, or postoperative PROMs. Conclusion. Despite a lower implant density and achieving correction through a convex rod, surgical correction of the Cobb angle and vertebral body rotation was similar in both groups. Periapical pedicle screws and primary correction on the concave side do not seem to be mandatory in order to achieve good surgical results in idiopathic thoracic scoliosis. The operating time was shorter in the group with lower implant density. In conclusion, the technique provided good results and has the potential to reduce complications and costs. Cite this article: Bone Joint J 2021;103-B(3):536–541


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims. Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment. Methods. A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019. Results. Mean overall patient satisfaction for the entire cohort was 4.7 (SE 0.1) on a 5-point Likert scale, with 93% being either very satisfied or satisfied compared with a Likert of 4.3 and patient satisfaction of 81% in the mechanical alignment group (p < 0.001 and p < 0.006 respectively). At mean follow-up of 17 months (11 to 27), the mean overall Likert, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten Joint Score, and Knee Society Knee and Function Scores were significantly better in the kinematic group than in the neutral mechanical alignment group. The most common complication in both groups was contracture requiring manipulation under anaesthesia, involving seven knees (6.1%) in the kinematic group and nine knees (7.8%) in the mechanical alignment group. Conclusion. With the advent of advanced technology, and the ability to obtain accurate bone cuts, the target limb alignment, and soft-tissue balance within millimetres, using a restricted kinematic alignment concept demonstrated excellent patient satisfaction following primary TKA. Longer-term analysis is required as to the durability of this method. Cite this article: Bone Joint J 2021;103-B(6 Supple A):59–66


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 627 - 632
2 May 2022
Sigmundsson FG Joelson A Strömqvist F

Aims. Lumbar disc prolapse is a frequent indication for surgery. The few available long-term follow-up studies focus mainly on repeated surgery for recurrent disease. The aim of this study was to analyze all reasons for additional surgery for patients operated on for a primary lumbar disc prolapse. Methods. We retrieved data from the Swedish spine register about 3,291 patients who underwent primary surgery for a lumbar disc prolapse between January 2007 and December 2008. These patients were followed until December 2020 to record all additional lumbar spine operations and the reason for them. Results. In total, 681 of the 3,291 patients (21%) needed one or more additional operations. More than three additional operations was uncommon (2%; 15/906). Overall, 906 additional operations were identified during the time period, with a mean time to the first of these of 3.7 years (SD 3.6). The most common reason for an additional operation was recurrent disc prolapse (47%; 426/906), followed by spinal stenosis or degenerative spondylolisthesis (19%; 176/906), and segmental pain (16%; 145/906). The most common surgical procedures were revision discectomy (43%; 385/906) and instrumented fusion (22%; 200/906). Degenerative spinal conditions other than disc prolapse became a more common reason for additional surgery with increasing length of follow-up. Most patients achieved the minimally important change (MIC) for the patient-reported outcomes after the index surgery. After the third additional spinal operation, only 20% (5/25) achieved the MIC in terms of leg pain, and 29% (7/24) in terms of the EuroQol five-dimension index questionnaire visual analogue scale. Conclusion. More than one in five patients operated on for a lumbar disc prolapse underwent further surgery during the 13-year follow-up period. Recurrent disc prolapse was the most common reason for additional surgery, followed by spinal stenosis and segmental pain. This study shows that additional operations after primary disc surgery are needed more frequently than previously reported, and that the outcome profoundly deteriorates after the second additional operation. The findings from this study can be used in the shared decision-making process. Cite this article: Bone Joint J 2022;104-B(5):627–632


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 549 - 555
1 Apr 2012
Lefaivre KA Slobogean GP Valeriote J O’Brien PJ Macadam SA

We performed a systematic review of the literature to evaluate the use and interpretation of generic and disease-specific functional outcome instruments in the reporting of outcome after the surgical treatment of disruptions of the pelvic ring. A total of 28 papers met our inclusion criteria, with eight reporting only generic outcome instruments, 13 reporting only pelvis-specific outcome instruments, and six reporting both. The Short-Form 36 (SF-36) was by far the most commonly used generic outcome instrument, used in 12 papers, with widely variable reporting of scores. The pelvis-specific outcome instruments were used in 19 studies; the Majeed score in ten, Iowa pelvic score in six, Hannover pelvic score in two and the Orlando pelvic score in one. Four sets of authors, all testing construct validity based on correlation with the SF-36, performed psychometric testing of three pelvis-specific instruments (Majeed, IPS and Orlando scores). No testing of responsiveness, content validity, criterion validity, internal consistency or reproducibility was performed. The existing literature in this area is inadequate to inform surgeons or patients in a meaningful way about the functional outcomes of these fractures after fixation


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 415 - 420
1 Feb 2021
Farr S Jauker F Ganger R Kranzl A

Aims. The aims of this study is to report the clinical and radiological outcomes after pre-, central-, and postaxial polydactyly resection in children from a tertiary referral centre. Methods. All children who underwent resection of a supernumerary toe between 2001 and 2013 were prospectively enrolled and invited for a single re-assessment. Clinical parameters and several dedicated outcome scores (visual analogue scale (VAS), Paediatric Outcomes Data Collection Instrument (PODCI), Activities Scale for Kids (ASK), and American Orthopaedic Foot and Ankle Society Score (AOFAS)) were obtained, as were radiographs of the operated and non-operated feet along with pedobarographs. Results. In all, 39 children (52 feet) with a mean follow-up of 7.2 years (3.1 to 13.0) were included in the study. Resection of a duplicated great toe was performed in ten children, central polydactyly in four, and postaxial polydactyly in 26. The mean postoperative VAS (0.7; 0 to 7), ASK (93.7; 64.2 to 100), and AOFAS range (85.9 to 89.0) indicated excellent outcomes among this cohort and the PODCI global functioning scale (95.7; 75.5 to 100) was satisfactory. No significant differences were found regarding outcomes of pre- versus postaxial patients, nor radiological toe alignment between the operated and non-operated sides. Minor complications were observed in six children (15%). There were seven surgical revisions (18%), six of whom were in preaxial patients. In both groups, below the operation area, a reduced mean and maximum force was observed. Changes in the hindfoot region were detected based on the prolonged contact time and reduced force in the preaxial group. Conclusion. Excellent mid-term results can be expected after foot polydactyly resection in childhood. However, parents and those who care for these children need to be counselled regarding the higher risk of subsequent revision surgery in the preaxial patients. Also, within the study period, the plantar pressure distribution below the operated part of the foot did not return to completely normal. Cite this article: Bone Joint J 2021;103-B(2):415–420


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1082 - 1089
1 Aug 2014
Roberts SB Tsirikos AI Subramanian AS

Clinical, radiological, and Scoliosis Research Society-22 questionnaire data were reviewed pre-operatively and two years post-operatively for patients with thoracolumbar/lumbar adolescent idiopathic scoliosis treated by posterior spinal fusion using a unilateral convex segmental pedicle screw technique. A total of 72 patients were included (67 female, 5 male; mean age at surgery 16.7 years (13 to 23)) and divided into groups: group 1 included 53 patients who underwent fusion between the vertebrae at the limit of the curve (proximal and distal end vertebrae); group 2 included 19 patients who underwent extension of the fusion distally beyond the caudal end vertebra. A mean scoliosis correction of 80% (45% to 100%) was achieved. The mean post-operative lowest instrumented vertebra angle, apical vertebra translation and trunk shift were less than in previous studies. A total of five pre-operative radiological parameters differed significantly between the groups and correlated with the extension of the fusion distally: the size of the thoracolumbar/lumbar curve, the lowest instrumented vertebra angle, apical vertebra translation, the Cobb angle on lumbar convex bending and the size of the compensatory thoracic curve. Regression analysis allowed an equation incorporating these parameters to be developed which had a positive predictive value of 81% in determining whether the lowest instrumented vertebra should be at the caudal end vertebra or one or two levels more distal. There were no differences in the Scoliosis Research Society-22 outcome scores between the two groups (p = 0.17). In conclusion, thoracolumbar/lumbar curves in patients with adolescent idiopathic scoliosis may be effectively treated by posterior spinal fusion using a unilateral segmental pedicle screw technique. Five radiological parameters correlate with the need for distal extension of the fusion, and an equation incorporating these parameters reliably informs selection of the lowest instrumented vertebra. Cite this article: Bone Joint J 2014;96-B:1082–9


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1526 - 1533
1 Dec 2019
Endler P Ekman P Berglund I Möller H Gerdhem P

Aims. Chronic low back pain due to degenerative disc disease is sometimes treated with fusion. We compared the outcome of three different fusion techniques in the Swedish Spine Register: noninstrumented posterolateral fusion (PLF), instrumented posterolateral fusion (IPLF), and interbody fusion (IBF). Patients and Methods. A total of 2874 patients who were operated on at one or two lumbar levels were followed for a mean of 9.2 years (3.6 to 19.1) for any additional lumbar spine surgery. Patient-reported outcome data were available preoperatively (n = 2874) and at one year (n = 2274), two years (n = 1958), and a mean of 6.9 years (n = 1518) postoperatively and consisted of global assessment and visual analogue scales of leg and back pain, Oswestry Disability Index, EuroQol five-dimensional index, 36-Item Short-Form Health Survey, and satisfaction with treatment. Statistical analyses were performed with competing-risks proportional hazards regression or analysis of covariance, adjusted for baseline variables. Results. The number of patients with additional surgery were 32/183 (17%) in the PLF group, 229/1256 (18%) in the IPLF group, and 439/1435 (31%) in the IBF group. With the PLF group as a reference, the hazard ratio for additional lumbar surgery was 1.16 (95% confidence interval (CI) 0.78 to 1.72) for the IPLF group and 2.13 (95% CI 1.45 to 3.12) for the IBF group. All patient-reported outcomes improved after surgery (p < 0.001) but were without statistically significant differences between the groups at the one-, two- and 6.9-year follow-ups (all p ≥ 0.12). Conclusion. The addition of interbody fusion to posterolateral fusion was associated with a higher risk for additional surgery and showed no advantages in patient-reported outcome. Cite this article: Bone Joint J 2019;101-B:1526–1533


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 690 - 695
1 May 2016
Dodd A Osterhoff G Guy P Lefaivre KA

We performed a systematic review of the literature pertaining to the functional outcomes of the surgical management of acetabular fractures. A total of 69 articles met our inclusion criteria, revealing that eight generic outcome instruments were used, along with five specific instruments. The majority of studies reported outcomes using a version of the d’Aubigne and Postel score, which has not been validated for use in acetabular fracture. Few validated outcome measures were reported. No psychometric testing of outcome instruments was performed. The current assessment of outcomes in surgery for acetabular fractures lacks scientific rigour, and does not give reliable outcome data for either scientific comparison or patient counselling. Take home message: The use of non-validated functional outcome measures is a major limitation of the current literature pertaining to surgical management of acetabular fractures; future studies should use validated outcome measures to ensure the legitimacy of the reported results. Cite this article: Bone Joint J 2016;98-B:690–5


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 42 - 47
1 Jan 2020
Jayakumar P Teunis T Vranceanu AM Williams M Lamb S Ring D Gwilym S

Aims. Patient engagement in adaptive health behaviours and interactions with their healthcare ecosystem can be measured using self-reported instruments, such as the Patient Activation Measure (PAM-13) and the Effective Consumer Scale (ECS-17). Few studies have investigated the influence of patient engagement on limitations (patient-reported outcome measures (PROMs)) and patient-reported experience measures (PREMs). First, we assessed whether patient engagement (PAM-13, ECS-17) within two to four weeks of an upper limb fracture was associated with limitations (the Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), and Patient-Reported Outcome Measurement Information System Upper Extremity Physical Function computer adaptive test (PROMIS UE PF) scores) measured six to nine months after fracture, accounting for demographic, clinical, and psychosocial factors. Secondly, we assessed the association between patient engagement and experience (numerical rating scale for satisfaction with care (NRS-C) and satisfaction with services (NRS-S) six to nine months after fracture. Methods. A total of 744 adults with an isolated fracture of the proximal humerus, elbow, or distal radius completed PROMs. Due to multicollinearity of patient engagement and psychosocial variables, we generated a single variable combining measures of engagement and psychosocial factors using factor analysis. We then performed multivariable analysis with p < 0.10 on bivariate analysis. Results. Patient engagement and psychosocial factors combined to form a single factor (factor 1) accounting for 20% (QuickDASH, semi-partial R. 2. = 0.20) and 14% (PROMIS UE PF, semi-partial R. 2. = 0.14) of the variation in limitations six to nine months after fracture. Factor 1 also accounted for 17% (NRS-C, semi-partial R. 2. = 0.17) of variation in satisfaction with care, and 21% (NRS-S, semi-partial R. 2. = 0.21) of variation in satisfaction with services. Demographic factors (age, sex, work status) and measures of greater pathophysiology (type of fracture, high-energy injury, post-surgical complications), accounted for much less variation. Conclusion. Patients who actively manage their health and demonstrate effective emotional and social functioning share a common underlying trait. They have fewer limitations and greater satisfaction with care during recovery from upper limb fractures. Future efforts should focus on evaluating initiatives that optimize patient engagement, such as patient education, coaching, and a communication strategy for healthcare professionals. Cite this article: Bone Joint J 2020;102-B(1):42–47


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1222 - 1226
1 Sep 2014
W-Dahl A Sundberg M Lidgren L Ranstam J Robertsson O

We identified a group of patients from the Swedish Arthroplasty Register who reported no relief of pain or worse pain one year after a total knee replacement (TKR). A total of two different patient-reported pain scores were used during this process. We then evaluated how the instruments used to measure pain affected the number of patients who reported no relief of pain or worse pain, and the relative effect of potential risk factors. . Between 2008 and 2010, 2883 TKRs were performed for osteoarthritis in two Swedish arthroplasty units. After applying exclusion criteria, 2123 primary TKRs (2123 patients) were included in the study. The Knee injury and Osteoarthritis Outcome Score (KOOS) and a Visual Analogue Scale (VAS) for knee pain were used to assess patients pre-operatively and one year post-operatively. . Only 50 of the 220 patients (23%) who reported no pain relief on either the KOOS pain subscale or the VAS for knee pain did so with both of these instruments. Patients who reported no pain relief on either measure tended to have less pain pre-operatively but a higher degree of anxiety. Charnley category C was a predictor for not gaining pain relief as measured on a VAS for knee pain. . The number of patients who are not relieved of pain after a TKR differs considerably depending on the instrument used to measure pain. . Cite this article: Bone Joint J 2014;96-B:1222–6


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 172 - 179
1 Feb 2023
Shimizu T Kato S Demura S Shinmura K Yokogawa N Kurokawa Y Yoshioka K Murakami H Kawahara N Tsuchiya H

Aims

The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF.

Methods

The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1423 - 1430
1 Nov 2019
Wiik AV Lambkin R Cobb JP

Aims. The aim of this study was to assess the functional gain achieved following hip resurfacing arthroplasty (HRA). Patients and Methods. A total of 28 patients (23 male, five female; mean age, 56 years (25 to 73)) awaiting Birmingham HRA volunteered for this prospective gait study, with an age-matched control group of 26 healthy adults (16 male, ten female; mean age, 56 years (33 to 84)). The Oxford Hip Score (OHS) and gait analysis using an instrumented treadmill were used preoperatively and more than two years postoperatively to measure the functional change attributable to the intervention. Results. The mean OHS improved significantly from 27 to 46 points (p < 0.001) at a mean of 29 months (12 to 60) after HRA. The mean metal ion levels at a mean 32 months (13 to 60) postoperatively were 1.71 (0.77 to 4.83) µg/l (ppb) and 1.77 (0.68 to 4.16) µg/l (ppb) for cobalt and chromium, respectively. When compared with healthy controls, preoperative patients overloaded the contralateral good hip, limping significantly. After HRA, patients walked at high speeds, with symmetrical gait, statistically indistinguishable from healthy controls over almost all characteristics. The control group could only be distinguished by an increased push-off force at higher speeds, which may reflect the operative approach. Conclusion. Patients undergoing HRA improved their preoperative gait pattern of a significant limp to a symmetrical gait at high speeds and on inclines, almost indistinguishable from normal controls. HRA with an approved device offers substantial functional gains, almost indistinguishable from healthy controls. Cite this article: Bone Joint J 2019;101-B:1423–1430


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 49 - 55
1 Apr 2017
Hossain F Konan S Volpin A Haddad FS

Aims. The aim of this study was to compare early functional and health related quality of life outcomes (HRQoL) in patients who have undergone total hip arthroplasty (THA) using a bone conserving short stem femoral component and those in whom a conventional length uncemented component was used. Outcome was assessed using a validated performance based outcome instrument as well as patient reported outcome measures (PROMs). Patients and Methods. We prospectively analysed 33 patients whose THA involved a contemporary proximally porous coated tapered short stem femoral component and 53 patients with a standard conventional femoral component, at a minimum follow-up of two years. The mean follow-up was 31.4 months (24 to 39). Patients with poor proximal femoral bone quality were excluded. The mean age of the patients was 66.6 years (59 to 77) and the mean body mass index was 30.2 kg/m. 2. (24.1 to 41.0). Outcome was assessed using the Oxford Hip Score (OHS) and the University College Hospital (UCH) hip score which is a validated performance based instrument. HRQoL was assessed using the EuroQol 5D (EQ-5D). Results. There were no major peri-operative complications. There was no difference in the mean post-operative OHS, EQ-5D or function subscale of the UCH hip scores between the two groups. The mean pre-operative OHS and EQ-5D scores improved significantly (all p <  0.001). The mean functional component of the UCH hip score at final follow-up was 42.5 and 40.6 in the short stem and conventional stem groups, respectively. There was no statistically significant difference between the groups (p = 0.42). A total of seven patients (21.2%) in the short stem group and nine (16.98%) in the conventional group achieved a ceiling effect using the OHS; none did using the function subscale of the UCH hip score. Conclusion. The proximally porous coated tapered short stem femoral component achieves comparable short-term functional outcomes when compared with a conventional longer stem uncemented femoral component when THA is undertaken in patients with good bone quality. Cite this article: Bone Joint J 2017;99-B(4 Supple B):49–55


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims

This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days.

Methods

We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1281 - 1283
1 Dec 2022
Azizpour K Birch NC Peul WC


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 662 - 667
1 May 2015
Mani SB Do H Vulcano E Hogan MV Lyman S Deland JT Ellis SJ

The foot and ankle outcome score (FAOS) has been evaluated for many conditions of the foot and ankle. We evaluated its construct validity in 136 patients with osteoarthritis of the ankle, its content validity in 37 patients and its responsiveness in 39. Data were collected prospectively from the registry of patients at our institution. All FAOS subscales were rated relevant by patients. The Pain, Activities of Daily Living, and Quality of Life subscales showed good correlation with the Physical Component score of the Short-Form-12v2. All subscales except Symptoms were responsive to change after surgery. We concluded that the FAOS is a weak instrument for evaluating osteoarthritis of the ankle. However, some of the FAOS subscales have relative strengths that allow for its limited use while we continue to seek other satisfactory outcome instruments. Cite this article: Bone Joint J 2015; 97-B:662–7


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271