Advertisement for orthosearch.org.uk
Results 1 - 27 of 27
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1681 - 1688
1 Dec 2017
Jones CW Shatrov J Jagiello JM Millington S Hong A Boyle R Stalley PD

Aims. We present a retrospective review of patients treated with extracorporeally irradiated allografts for primary and secondary bone tumours with the mid- and long-term survivorship and the functional and radiographic outcomes. Patients and Methods. A total of 113 of 116 (97.4%) patients who were treated with extracorporeally irradiated allografts between 1996 and 2014 were followed up. Forms of treatment included reconstructions, prostheses and composite reconstructions, both with and without vascularised grafts. Survivorship was determined by the Kaplan-Meier method. Clinical outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) scoring system, the Toronto Extremity Salvage Score (TESS) and Quality of Life-C30 (QLQ-30) measures. Radiographic outcomes were assessed using the International Society of Limb Salvage (ISOLS) radiographic scoring system. Results. There were 61 (54%) men with a mean age of 22 years (6 to 70) and 52 (46%) women with a mean age of 26 years (3 to 85). There were 23 deaths. The five-year patient survivorship was 82.3% and the ten-year patient survivorship was 79.6%. The mean follow-up of the 90 surviving patients was 80.3 months (2 to 207). At the last follow-up, 105 allografts (92.9%) were still in place or had been at the time of death; eight (7%) had failed due to infection, local recurrence or fracture. Outcome scores were comparable with or superior to those in previous studies. The mean outcome scores were: MSTS 79% (. sd. 8); TESS 83% (. sd. 19); QLQ 82% (. sd. 16); ISOLS 80.5% (. sd. 19). . Pearson correlation analysis showed a strong relationship between the MSTS and ISOLS scores (r = 0.71, p < 0.001). Conclusion. This study shows that extracorporeal irradiation is a versatile reconstructive technique for dealing with large defects after the resection of bone tumours with good functional and radiographic outcomes. Functional outcomes as measured by MSTS, TESS and QLQ-30 were strongly correlated to radiographic outcomes. Cite this article: Bone Joint J 2017;99-B:1681–8


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1151 - 1159
1 Sep 2019
Oike N Kawashima H Ogose A Hatano H Ariizumi T Kaidu M Aoyama H Endo N

Aims. We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts. Patients and Methods. This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients, intercalary grafts in 15 patients, and osteoarticular grafts in seven patients. Functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system. Results. There were no recurrences in the irradiated autograft and the autograft survived in 24 patients (88.9%). Major complications included nonunion (n = 9), subchondral bone collapse (n = 4), and deep infection (n = 4). Although 34 revision procedures were performed, 25 (73.5%) and four (11.8%) of these were performed less than five years and ten years after the initial surgery, respectively. The mean MSTS score at the last follow-up was 84.3% (33% to 100%). Conclusion. Considering long-term outcomes, extracorporeal irradiated autograft is an effective method of reconstruction for malignant musculoskeletal tumours. Cite this article: Bone Joint J 2019;101-B:1151–1159


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 366 - 371
1 Mar 2007
Krieg AH Davidson AW Stalley PD

Between 1996 and 2003, 16 patients (nine female, seven male) were treated for a primary bone sarcoma of the femur by wide local excision of the tumour, extracorporeal irradiation and re-implantation. An additional vascularised fibular graft was used in 13 patients (81%). All patients were free from disease when reviewed at a minimum of two years postoperatively (mean 49.7 months (24 to 96). There were no cases of infection. Primary union was achieved after a median of nine months (interquartile range 7 to 11). Five host-donor junctions (16%) united only after a second procedure. Primary union recurred faster at metaphyseal junctions (94% (15) at a median of 7.5 months (interquartile range 4 to 12)) than at diaphyseal junctions (75% (12) at a median of 11.1 months (interquartile range 5 to 18)). Post-operatively, the median Musculoskeletal Tumour Society score was 85% (interquartile range 75 to 96) and the median Toronto Extremity Salvage score 94% (interquartile range 82 to 99). The Mankin score gave a good or excellent result in 14 patients (88%). The range of movement of the knee was significantly worse when the extracorporeally irradiated autografts were fixed by plates rather than by nails (p = 0.035). A total of 16 (62%) of the junctions of the vascularised fibular grafts underwent hypertrophy, indicating union and loading. Extracorporeal irradiation autografting with supplementary vascularised fibular grafting is a promising biological alternative for intercalary reconstruction after wide resection of malignant bone tumours of the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 851 - 857
1 Jun 2005
Davidson AW Hong A McCarthy SW Stalley PD

We treated 50 patients with bony malignancy by en-bloc resection, extracorporeal irradiation with 50 Gy and re-implantation of the bone segment. The mean survivor follow-up was 38 months (12 to 92) when 42 patients were alive and without disease. There were four recurrences. The functional results were good according to the Mankin score (17 excellent, 13 good, nine fair, three failures), the Musculoskeletal Tumour Society score (mean 77) and the Toronto Extremity Salvage score (mean 81). There was solid union, but bone resorption was seen in some cases. The dose of radiation was lethal to all cells and produced a dead autograft of perfect fit. Extracorporeal irradiation is a useful technique for limb salvage when there is reasonable residual bone stock. It allows effective re-attachment of tendons and produces a lasting biological reconstruction. There should be no risk of local recurrence or of radiotherapy-induced malignancy in the replanted bone


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1006 - 1011
1 Jul 2005
Hatano H Ogose A Hotta T Endo N Umezu H Morita T

We examined osteochondral autografts, obtained at a mean of 19.5 months (3 to 48) following extracorporeal irradiation and re-implantation to replace bone defects after removal of tumours. The specimens were obtained from six patients (mean age 13.3 years (10 to 18)) and consisted of articular cartilage (five), subchondral bone (five), external callus (one) and tendon (one). The tumour cells in the grafts were eradicated by a single radiation dose of 60 Gy. In three cartilage specimens, viable chondrocytes were detected. The survival of chondrocytes was confirmed with S-100 protein staining. Three specimens from the subchondral region and a tendon displayed features of regeneration. Callus was seen at the junction between host and irradiated bone


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 348 - 353
1 May 1988
Uyttendaele D De Schryver A Claessens H Roels H Berkvens P Mondelaers W

En-bloc resection, extracorporeal irradiation and re-implantation of the irradiated bone have been used to treat 15 patients suffering from primary malignant tumours of bone or cartilage and two with benign lesions. This treatment is an alternative to replacement by prosthesis or allograft bridging techniques. After a mean follow-up of over five years results are encouraging, despite some complications and the relatively long period before weight-bearing is allowed


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1156 - 1161
1 Nov 2002
Chen WM Chen TH Huang CK Chiang CC Lo WH

Autogenous bone graft which has been either autoclaved or irradiated is commonly used in oriental countries as an alternative to allograft. We started to use the technique of extracorporeal irradiation of the resected specimen and reimplantation (ECIR) in 1991. There was, however, a high incidence of fracture of the irradiated bone and loss of articular cartilage. In an attempt to reduce these complications, we combined the irradiated autograft with a conventional arthroplasty. Between 1995 and 1998, 14 patients underwent limb salvage by this method. Seven had an osteosarcoma, two bony metastases, three a chondrosarcoma, one a malignant fibrous histiocytoma, and one a leiomyosarcoma. Ten tumours were located in the proximal femur, two in the proximal humerus, and two in the distal femur. One patient who had a solitary metastasis in the proximal part of the left femur died from lung metastases 13 months after operation. The remaining 13 patients were alive and without evidence of local recurrence or distant metastases at a mean follow-up of 43 months (28 to 72). Postoperative palsy of the sciatic nerve occurred in one patient, but no complications such as wound infection, fracture, or nonunion were seen. All host-irradiated bone junctions healed uneventfully within eight months. Using the Enneking functional evaluation system, the mean postoperative score for all 14 patients was 80% (57 to 93). The use of irradiated autograft prosthesis composites reduces the complications of ECIR and gives good functional results. It may be a good alternative in limb-salvage surgery, especially in countries where it is difficult to obtain allografts


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 395 - 400
1 Mar 2009
Krieg AH Mani M Speth BM Stalley PD

We review the treatment of pelvic Ewing’s sarcoma by the implantation of extracorporeally-irradiated (ECI) autografts and compare the outcome with that of other reported methods.

We treated 13 patients with ECI autografts between 1994 and 2004. There were seven males and six females with a median age of 15.7 years (interquartile range (IQR) 12.2 to 21.7). At a median follow-up of five years (IQR 1.8 to 7.4), the disease-free survival was 69% overall, and 75% if one patient with local recurrence after initial treatment elsewhere was excluded. Four patients died from distant metastases at a mean of 17 months (13 to 23). There were three complications which required operative intervention; one was a deep infection which required removal of the graft. The functional results gave a mean Musculoskeletal Tumor Society score of 85% (60% to 97%), a mean Toronto extremity salvage score of 86% (69% to 100%) and a mean Harris hip score of 92 (67 to 100).

We conclude that ECI grafting is a suitable form of treatment for localised and resectable pelvic Ewing’s sarcoma.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1152 - 1156
1 Aug 2015
Gupta S Cafferky D Cowie F Riches P Mahendra A

Extracorporeal irradiation of an excised tumour-bearing segment of bone followed by its re-implantation is a technique used in bone sarcoma surgery for limb salvage when the bone is of reasonable quality. There is no agreement among previous studies about the dose of irradiation to be given: up to 300 Gy have been used. We investigated the influence of extracorporeal irradiation on the elastic and viscoelastic properties of bone. Bone was harvested from mature cattle and subdivided into 13 groups: 12 were exposed to increasing levels of irradiation: one was not and was used as a control. The specimens, once irradiated, underwent mechanical testing in saline at 37°C. The mechanical properties of each group, including Young’s modulus, storage modulus and loss modulus, were determined experimentally and compared with the control group. . There were insignificant changes in all of these mechanical properties with an increasing level of irradiation. . We conclude that the overall mechanical effect of high levels of extracorporeal irradiation (300 Gy) on bone is negligible. Consequently the dose can be maximised to reduce the risk of local tumour recurrence. Cite this article: Bone Joint J 2015;97-B:1152–6


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 276 - 282
1 Mar 2000
Sabo D Brocai DRC Eble M Wannenmacher M Ewerbeck V

We studied the effects of irradiation on the reintegration of autologous osteoarticular grafts over a period of 24 weeks in a canine model. In 16 foxhounds the medial femoral condyle was resected, irradiated and immediately replanted. In the control group resection and replantation were performed without irradiation. Reintegration was assessed by macroscopic analysis, histology, radiography and gait analysis.

Reintegration was equal at 12 weeks, but significantly inferior in the irradiated group after 24 weeks with delayed bone remodelling. The articular cartilage showed modest degeneration. Conventional radiography and histology showed corresponding changes. Limb function was adequate but the gait was inferior in the treated group.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1282 - 1287
1 Sep 2012
Mottard S Grimer RJ Abudu A Carter SR Tillman RM Jeys L Spooner D

The purpose of this study was to assess the outcome of 15 patients (mean age 13.6 years (7 to 25)) with a primary sarcoma of the tibial diaphysis who had undergone excision of the affected segment that was then irradiated (90 Gy) and reimplanted with an ipsilateral vascularised fibular graft within it.

The mean follow-up was 57 months (22 to 99). The mean time to full weight-bearing was 23 weeks (9 to 57) and to complete radiological union 42.1 weeks (33 to 55). Of the 15 patients, seven required a further operation, four to obtain skin cover. The mean Musculoskeletal Society Tumor Society functional score at final follow-up was 27 out of 30 once union was complete. The functional results were comparable with those of allograft reconstruction and had a similar rate of complication.

We believe this to be a satisfactory method of biological reconstruction of the tibial diaphysis in selected patients.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1404 - 1410
1 Oct 2014
Wafa H Grimer RJ Jeys L Abudu AT Carter SR Tillman RM

The aim of this study was to evaluate the functional and oncological outcome of extracorporeally irradiated autografts used to reconstruct the pelvis after a P1/2 internal hemipelvectomy. The study included 18 patients with a primary malignant bone tumour of the pelvis. There were 13 males and five females with a mean age of 24.8 years (8 to 62). Of these, seven had an osteogenic sarcoma, six a Ewing’s sarcoma, and five a chondrosarcoma. At a mean follow-up of 51.6 months (4 to 185), nine patients had died with metastatic disease while nine were free from disease. Local recurrence occurred in three patients all of whom eventually died of their disease. Deep infection occurred in three patients and required removal of their graft in two while the third underwent a hindquarter amputation for extensive flap necrosis. The mean Musculoskeletal Tumor Society functional score of the 16 patients who could be followed-up for at least 12 months was 77% (50 to 90). Those 15 patients who completed the Toronto Extremity Salvage Score questionnaire had a mean score of 71% (53 to 85). . Extracorporeal irradiation and re-implantation of bone is a valid method of reconstruction after an internal hemipelvectomy. It has an acceptable morbidity and a functional outcome that compares favourably with other available reconstructive techniques. Cite this article: Bone Joint J 2014;96-B:1404–10


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 795 - 803
1 Apr 2021
Fujiwara T Medellin Rincon MR Sambri A Tsuda Y Clark R Stevenson J Parry MC Grimer RJ Jeys L

Aims. Limb salvage for pelvic sarcomas involving the acetabulum is a major surgical challenge. There remains no consensus about what is the optimum type of reconstruction after resection of the tumour. The aim of this study was to evaluate the surgical outcomes in these patients according to the methods of periacetabular reconstruction. Methods. The study involved a consecutive series of 122 patients with a periacetabular bone sarcoma who underwent limb-salvage surgery involving a custom-made prosthesis in 65 (53%), an ice-cream cone prosthesis in 21 (17%), an extracorporeal irradiated autograft in 18 (15%), and nonskeletal reconstruction in 18 (15%). Results. The rates of major complications necessitating further surgery were 62%, 24%, 56%, and 17% for custom-made prostheses, ice-cream cone prostheses, irradiated autografts and nonskeletal reconstructions, respectively (p = 0.001). The ten-year cumulative incidence of failure of the reconstruction was 19%, 9%, 33%, and 0%, respectively. The major cause of failure was deep infection (11%), followed by local recurrence (6%). The mean functional Musculoskeletal Tumour Society (MSTS) scores were 59%, 74%, 64%, and 72%, respectively. The scores were significantly lower in patients with major complications than in those without complications (mean 52% (SD 20%) vs 74% (SD 19%); p < 0.001). For periacetabular resections involving the ilium, the mean score was the highest with custom-made prostheses (82% (SD 10%)) in patients without any major complication; however, nonskeletal reconstruction resulted in the highest mean scores (78% (SD 12%)) in patients who had major complications. For periacetabular resections not involving the ilium, significantly higher mean scores were obtained with ice-cream cone prostheses (79% (SD 17%); p = 0.031). Conclusion. Functional outcome following periacetabular reconstruction is closely associated with the occurrence of complications requiring further surgery. For tumours treated with periacetabular and iliac resection, skeletal reconstruction may result in the best outcomes in the absence of complications, whereas nonskeletal reconstruction is a reasonable option if the risk of complications is high. For tumours requiring periacetabular resection without the ilium, reconstruction using an ice-cream cone prosthesis supported by antibiotic-laden cement is a reliable option. Cite this article: Bone Joint J 2021;103-B(4):795–803


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 982 - 988
1 Jul 2012
Puri A Gulia A Jambhekar N Laskar S

We analysed the outcome of patients with primary non-metastatic diaphyseal sarcomas who had en bloc resection with preservation of the adjoining joints and reconstruction with re-implantation of sterilised tumour bone after extracorporeal radiation (50 Gy). Between March 2005 and September 2009, 32 patients (16 Ewing’s sarcoma and 16 osteogenic sarcoma) with a mean age of 15 years (2 to 35) underwent this procedure. The femur was the most common site in 17 patients, followed by the tibia in 11, humerus in three and ulna in one. The mean resected length of bone was 19 cm (10 to 26). A total of 31 patients were available at a mean follow-up of 34 months (12 to 74). The mean time to union for all osteotomy sites was 7.3 months (3 to 28): metaphyseal osteotomy sites united quicker than diaphyseal osteotomy sites (5.8 months (3 to 10) versus 9.5 months (4 to 28)). There were three local recurrences, all in soft-tissue away from irradiated graft. At the time of final follow-up, 19 patients were free of disease, one was alive with disease and 11 had died of disease. The mean Musculoskeletal Tumor Society Score for 29 patients evaluated at the last follow-up was 26 (9 to 30). Extracorporeal irradiation is an oncologically safe and inexpensive technique for limb salvage in diaphyseal sarcomas and has good functional results


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 258 - 264
1 Feb 2015
Young PS Bell SW Mahendra A

We report our experience of using a computer navigation system to aid resection of malignant musculoskeletal tumours of the pelvis and limbs and, where appropriate, their subsequent reconstruction. We also highlight circumstances in which navigation should be used with caution. We resected a musculoskeletal tumour from 18 patients (15 male, three female, mean age of 30 years (13 to 75) using commercially available computer navigation software (Orthomap 3D) and assessed its impact on the accuracy of our surgery. Of nine pelvic tumours, three had a biological reconstruction with extracorporeal irradiation, four underwent endoprosthetic replacement (EPR) and two required no bony reconstruction. There were eight tumours of the bones of the limbs. Four diaphyseal tumours underwent biological reconstruction. Two patients with a sarcoma of the proximal femur and two with a sarcoma of the proximal humerus underwent extra-articular resection and, where appropriate, EPR. One soft-tissue sarcoma of the adductor compartment which involved the femur was resected and reconstructed using an EPR. Computer navigation was used to aid reconstruction in eight patients. Histological examination of the resected specimens revealed tumour-free margins in all patients. Post-operative radiographs and CT showed that the resection and reconstruction had been carried out as planned in all patients where navigation was used. In two patients, computer navigation had to be abandoned and the operation was completed under CT and radiological control. The use of computer navigation in musculoskeletal oncology allows accurate identification of the local anatomy and can define the extent of the tumour and proposed resection margins. Furthermore, it helps in reconstruction of limb length, rotation and overall alignment after resection of an appendicular tumour. . Cite this article: Bone Joint J 2015;97-B:258–64


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 64 - 71
1 Jan 2020
Tsuda Y Fujiwara T Stevenson JD Parry MC Tillman R Abudu A

Aims

The purpose of this study was to report the long-term results of extendable endoprostheses of the humerus in children after the resection of a bone sarcoma.

Methods

A total of 35 consecutive patients treated with extendable endoprosthetic replacement of the humerus in children were included. There were 17 boys and 18 girls in the series with a median age at the time of initial surgery of nine years (interquartile range (IQR) 7 to 11).


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1567 - 1573
7 Nov 2020
Sambri A Dalla Rosa M Scorianz M Guido D Donati DM Campanacci DA De Paolis M

Aims

The aim of this study was to report the results of three forms of reconstruction for patients with a ditsl tibial bone tumour: an intercalary resection and reconstruction, an osteoarticular reconstruction, and arthrodesis of the ankle.

Methods

A total of 73 patients with a median age of 19 years (interquartile range (IQR) 14 to 36) were included in this retrospective, multicentre study.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1551 - 1555
1 Nov 2013
Kaa AKS Jørgensen PH Søjbjerg JO Johannsen HV

We investigated the functional outcome in patients who underwent reverse shoulder replacement (RSR) after removal of a tumour of the proximal humerus. A total of 16 patients (ten women and six men) underwent this procedure between 1998 and 2011 in our hospital. Five patients died and one was lost to follow-up. Ten patients were available for review at a mean follow-up of 46 months (12 to 136). Eight patients had a primary and two patients a secondary bone tumour.

At final follow up the mean range of active movement was: abduction 78° (30° to 150°); flexion 98° (45° to 180°); external rotation 32° (10° to 60°); internal rotation 51° (10° to 80°). The mean Musculoskeletal Tumor Society score was 77% (60% to 90%) and the mean Toronto Extremity Salvage Score was 70% (30% to 91%). Two patients had a superficial infection and one had a deep infection and underwent a two-stage revision procedure. In two patients there was loosening of the RSR; one dislocated twice. All patients had some degree of atrophy or pseudo-atrophy of the deltoid muscle.

Use of a RSR in patients with a tumour of the proximal humerus gives acceptable results.

Cite this article: Bone Joint J 2013;95-B:1551–5.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1280 - 1284
1 Sep 2013
Yamaguchi T Matsumine A Niimi R Nakamura T Matsubara T Asanuma K Hasegawa M Sudo A

The aim of this study was to define the incidence of venous thromboembolism (VTE) and risk factors for the development of deep-vein thrombosis (DVT) after the resection of a musculoskeletal tumour. A total of 94 patients who underwent resection of a musculoskeletal tumour between January 2003 and December 2005 were prospectively studied. There were 42 men and 52 women with a mean age of 54.4 years (18 to 86). All patients wore intermittent pneumatic compression devices and graduated compression stockings. Ultrasound examination of the lower limbs was conducted to screen for DVT between the fifth and ninth post-operative days.

DVT was detected in 21 patients (22%). Of these, two were symptomatic (2%). One patient (1%) had a fatal pulmonary embolism. Patients aged ≥ 70 years had an increased risk of DVT (p = 0.004).

The overall incidence of DVT (both symptomatic and asymptomatic) after resection of a musculoskeletal tumour with mechanical prophylaxis was high. It seems that both mechanical and anticoagulant prophylaxis is needed to prevent VTE in patients who have undergone the resection of a musculoskeletal tumour.

Cite this article: Bone Joint J 2013;95-B:1280–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 704 - 709
1 May 2005
Chen TH Chen WM Huang CK

We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft reconstruction and 15 extracorporeally-irradiated autograft.

At a mean follow-up of 71 months (24 to 132), 20 were free from disease, five had died and four were alive with pulmonary metastases. Two patients, one with an allograft and one with an irradiated autograft, had a local recurrence. Reconstruction with extracorporeally-irradiated autograft has a significantly lower rate of nonunion (7% vs 43%, p = 0.031) but an insignificantly higher rate of fracture (20% vs 14%, p = 0.535) than that with segmental allograft. Using the Enneking functional evaluation system, the mean postoperative score for the patients without local recurrence was 87% (80% to 96%) and was similar in both groups.

Extracorporeally-irradiated autograft could be an acceptable alternative for reconstruction after intercalary resection, especially in countries where it is difficult to obtain allografts.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1698 - 1703
1 Dec 2015
Laitinen M Parry M Albergo JI Jeys L Abudu A Carter S Sumathi V Grimer R

The aim of this study was to evaluate the prognostic and therapeutic factors which influence the oncological outcome of parosteal osteosarcoma.

A total of 80 patients with a primary parosteal osteosarcoma were included in this retrospective study. There were 51 females and 29 males with a mean age of 29.9 years (11 to 78).

The mean follow-up was 11.2 years (1 to 40). Overall survival was 91.8% at five years and 87.8% at ten years. Local recurrence occurred in 14 (17.5%) patients and was associated with intralesional surgery and a large volume of tumour. On histological examination, 80% of the local recurrences were dedifferentiated high-grade tumours. A total of 12 (14.8%) patients developed pulmonary metastases, of whom half had either a dedifferentiated tumour or a local recurrence. Female gender and young age were good prognostic factors. Local recurrence was a poor prognostic factor for survival. Medullary involvement or the use of chemotherapy had no impact on survival.

The main goal in treating a parosteal osteosarcoma must be to achieve a wide surgical margin, as inadequate margins are associated with local recurrence. Local recurrence has a significant negative effect on survival, as 80% of the local recurrences are high-grade dedifferentiated tumours, and half of these patients develop metastases.

The role of chemotherapy in the treatment of parosteal osteosarcoma is not as obvious as it is in the treatment of conventional osteosarcoma. The mainstay of treatment is wide local excision.

Cite this article: Bone Joint J 2015;97-B:1698–1703.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 411 - 418
1 Mar 2013
Nakamura T Grimer RJ Gaston CL Watanuki M Sudo A Jeys L

The aim of this study was to determine whether the level of circulating C-reactive protein (CRP) before treatment predicted overall disease-specific survival and local tumour control in patients with a sarcoma of bone.

We retrospectively reviewed 318 patients who presented with a primary sarcoma of bone between 2003 and 2010. Those who presented with metastases and/or local recurrence were excluded.

Elevated CRP levels were seen in 84 patients before treatment; these patients had a poorer disease-specific survival (57% at five years) than patients with a normal CRP (79% at five years) (p < 0.0001). They were also less likely to be free of recurrence (71% at five years) than patients with a normal CRP (79% at five years) (p = 0.04). Multivariate analysis showed the pre-operative CRP level to be an independent predictor of survival and local control. Patients with a Ewing’s sarcoma or chondrosarcoma who had an elevated CRP before their treatment started had a significantly poorer disease-specific survival than patients with a normal CRP (p = 0.02 and p < 0.0001, respectively). Patients with a conventional osteosarcoma and a raised CRP were at an increased risk of poorer local control.

We recommend that CRP levels are measured routinely in patients with a suspected sarcoma of bone as a further prognostic indicator of survival.

Cite this article: Bone Joint J 2013;95-B:411–18.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 867 - 874
1 Jun 2010
Hanna SA Sewell MD Aston WJS Pollock RC Skinner JA Cannon SR Briggs TWR

Segmental resection of malignant bone disease in the femoral diaphysis with subsequent limb reconstruction is a major undertaking. This is a retrospective review of 23 patients who had undergone limb salvage by endoprosthetic replacement of the femoral diaphysis for a primary bone tumour between 1989 and 2005.

There were 16 males and seven females, with a mean age of 41.3 years (10 to 68). The mean overall follow-up was for 97 months (3 to 240), and 120 months (42 to 240) for the living patients. The cumulative patient survival was 77% (95% confidence interval 63% to 95%) at ten years. Survival of the implant, with failure of the endoprosthesis as an endpoint, was 85% at five years and 68% (95% confidence interval 42% to 92%) at ten years. The revision rate was 22% and the overall rate of re-operation was 26%. Complications included deep infection (4%), breakage of the prosthesis (8%), periprosthetic fracture (4%), aseptic loosening (4%), local recurrence (4%) and metastases (17%). The 16 patients who retained their diaphyseal endoprosthesis had a mean Musculoskeletal Tumour Society score of 87% (67% to 93%). They were all able to comfortably perform most activities of daily living.

Femoral diaphyseal endoprosthetic replacement is a viable option for reconstruction following segmental resection of malignant bone disease. It allows immediate weight-bearing, is associated with a good long-term functional outcome, has an acceptable complication and revision rate and, most importantly, does not appear to compromise patient survival.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1642 - 1646
1 Dec 2006
Shalaby S Shalaby H Bassiony A

We report the results of limb salvage for non-metastatic osteosarcoma of the distal tibia using resection arthrodesis, autogenous fibular graft and fixation by an Ilizarov external fixator.

In six patients with primary osteosarcoma of the distal tibia who refused amputation, treatment with wide en bloc resection and tibiotalar arthrodesis was undertaken. The defect was reconstructed using non-vascularised free autogenous fibular strut graft in three patients and a vascularised pedicular fibular graft in three, all supplemented with iliac cancellous graft at the graft-host junction. An Ilizarov external fixator was used for stabilisation of the reconstruction.

In five patients sound fusion occurred at a mean of 13.2 months (8 to 20) with no evidence of local recurrence or deep infection at final follow-up. The mean post-operative functional score was 70% (63% to 73%) according to the Musculoskeletal Tumour Society scoring system. All five patients showed graft hypertrophy.

Union of the graft was faster in cases reconstructed by vascularised fibular grafts. One patient who had a poor response to pre-operative chemotherapy developed local tumour recurrence at one year post-operatively and required subsequent amputation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 234 - 239
1 Feb 2009
Puri A Subin BS Agarwal MG

We evaluated the results of fibular centralisation as a stand alone technique to reconstruct defects that occurred after resection of tumours involving the tibial diaphysis and distal metaphysis.

Between January 2003 and December 2006, 15 patients underwent excision of tumours of the tibial diaphysis or distal metaphysis and reconstruction by fibular centralisation. Their mean age was 17 years (7 to 40). Two patients were excluded; one died from the complications of chemotherapy and a second needed a below-knee amputation for a recurrent giant-cell tumour. A total of 13 patients were reviewed after a mean follow-up of 29 months (16 to 48). Only 16 of 26 host graft junctions united primarily. Ten junctions in ten patients needed one or more further procedure before union was achieved. At final follow-up 12 of the 13 patients had fully united grafts; 11 walked without aids. The mean time to union at the junctions that united was 12 months (3 to 36). The mean Musculoskeletal Tumor Society Score was 24.7 (16 to 30).

Fibular centralisation is a durable reconstruction for defects of the tibial diaphysis and distal metaphysis with an acceptable functional outcome. Stable osteosynthesis is the key to successful union. Additional bone grafting is recommended for patients who need postoperative radiotherapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1487 - 1491
1 Nov 2006
Ahlmann ER Menendez LR

Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of bone tumours. The aim of this study was to determine the survival of intercalary endoprostheses with a lap joint design, and to evaluate the clinical results, complications and functional outcome. We retrospectively reviewed six consecutive patients, three of whom underwent limb salvage with intercalary endoprostheses of the tibia, two of the femur, and one of the humerus. Their mean age was 42 years (28 to 64). The mean follow-up was 21.6 months (9 to 58). The humeral prosthesis required revision at 14 months owing to aseptic loosening. There were no implant-related failures. Musculoskeletal Tumour Society functional outcome scores indicated that patients achieved 90% of premorbid function.

Custom intercalary endoprostheses result in reconstructions comparable with, if not better than, those of allografts. Using this design of implant reduces the incidence of early complications and difficulties experienced with previous versions.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1435 - 1441
1 Oct 2010
Bischel OE Böhm PM

Endoprosthetic reconstruction following resection of 31 tumours of the proximal femur in 30 patients was performed using a Wagner SL femoral revision stem. The mean follow-up was 25.6 months (0.6 to 130.0). Of the 28 patients with a metastasis, 27 died within a mean follow-up period of 18.1 months (0.6 to 56.3) after the operation, and the remaining patient was excluded from the study 44.4 months post-operatively when the stem was removed. The two patients with primary bone tumours were still alive at the latest follow-up of 81.0 and 130.0 months, respectively. One stem only was removed for suspected low-grade infection 44.4 months post-operatively. The worst-case survival rate with removal of the stem for any cause and/or loss to follow-up was 80.0% (95% confidence interval 44.9 to 100) at 130.0 months. The mean Karnofsky index increased from 44.2% (20% to 70%) pre-operatively to 59.7% (0% to 100%) post-operatively, and the mean Merle d’Aubigné score improved from 4.5 (0 to 15) to 12.0 (0 to 18). The mean post-operative Musculoskeletal Tumour Society score was 62.4% (3.3% to 100%).

The Wagner SL femoral revision stem offers an alternative to special tumour prostheses for the treatment of primary and secondary tumours of the proximal femur. The mid-term results are very promising, but long-term experience is necessary.