Advertisement for orthosearch.org.uk
Results 1 - 50 of 59
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1118 - 1124
1 Oct 2024
Long Y Zheng Z Li X Cui D Deng X Guo J Yang R

Aims. The aims of this study were to validate the minimal clinically important difference (MCID) and patient-acceptable symptom state (PASS) thresholds for Western Ontario Shoulder Instability Index (WOSI), Rowe score, American Shoulder and Elbow Surgeons (ASES), and visual analogue scale (VAS) scores following arthroscopic Bankart repair, and to identify preoperative threshold values of these scores that could predict the achievement of MCID and PASS. Methods. A retrospective review was conducted on 131 consecutive patients with anterior shoulder instability who underwent arthroscopic Bankart repair between January 2020 and January 2023. Inclusion criteria required at least one episode of shoulder instability and a minimum follow-up period of 12 months. Preoperative and one-year postoperative scores were assessed. MCID and PASS were estimated using distribution-based and anchor-based methods, respectively. Receiver operating characteristic curve analysis determined preoperative patient-reported outcome measure thresholds predictive of achieving MCID and PASS. Results. MCID thresholds were determined as 169.6, 6.8, 7.2, and 1.1 for WOSI, Rowe, ASES, and VAS, respectively. PASS thresholds were calculated as ≤ 480, ≥ 80, ≥ 87, and ≤ 1 for WOSI, Rowe, ASES, and VAS, respectively. Preoperative thresholds of ≥ 760 (WOSI) and ≤ 50 (Rowe) predicted achieving MCID for WOSI score (p < 0.001). Preoperative thresholds of ≤ 60 (ASES) and ≥ 2 (VAS) predicted achieving MCID for VAS score (p < 0.001). A preoperative threshold of ≥ 40 (Rowe) predicted achieving PASS for Rowe score (p = 0.005). Preoperative thresholds of ≥ 50 (ASES; p = 0.002) and ≤ 2 (VAS; p < 0.001) predicted achieving PASS for the ASES score. Preoperative thresholds of ≥ 43 (ASES; p = 0.046) and ≤ 4 (VAS; p = 0.024) predicted achieving PASS for the VAS. Conclusion. This study defined MCID and PASS values for WOSI, Rowe, ASES, and VAS scores in patients undergoing arthroscopic Bankart repair. Higher preoperative functional scores may reduce the likelihood of achieving MCID but increase the likelihood of achieving the PASS. These findings provide valuable guidance for surgeons to counsel patients realistically regarding their expectations. Cite this article: Bone Joint J 2024;106-B(10):1118–1124


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims. The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears. Methods. A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI. Results. Patients in group RL were significantly older than in group L (p = 0.008), and group RL was significantly associated with female sex (odds ratio 2.5 (95% confidence interval 1.03 to 6.32); p = 0.041). Mean postoperative pain visual analogue scale (VAS) score was significantly greater (group L = 0.8 (SD 1.5), group RL = 1.7 (SD 2.2); p = 0.033) and mean postoperative American Shoulder and Elbow Surgeons (ASES) score was significantly lower in group RL than group L (group L = 91.4 (SD 13.1), group RL = 83.8 (SD 17.9); p = 0.028). However, postoperative mean VAS for pain and ASES score were not lower than the patient-acceptable symptom state scores. Mean retracted tear length was significantly larger in group L (group L = 24.6 mm (SD 6.5), group RL = 20.0 mm (SD 6.8); p = 0.003). Overall re-tear rate for 82 tears was 11.0% (nine shoulders), and re-tear rates in group L and RL were similar at 11.1% (four shoulders) and 10.9% (five shoulders), respectively (p = 1.000). No significant intergroup difference was found for fatty degeneration (FD) or muscle atrophy. Within group L, postoperative FD grades of supraspinatus and subscapularis worsened significantly (p = 0.034 and p = 0.008, respectively). Mean postoperative pain VAS (male = 1.2 (SD 1.8), female = 1.3 (SD 2.0)) and ASES scores (male = 88.7 (SD 15.5), female = 86.0 (SD 16.8)) were similar in male and female patients (p = 0.700 and p = 0.475, respectively). Regression analysis showed age was not a prognostic factor of postoperative pain VAS or ASES scores (p = 0.188 and p = 0.150, respectively). Conclusion. Older age and female sex were associated with reverse L-shaped tears. Although the postoperative functional outcomes of patients with reverse L-shaped tears were satisfactory, the clinical scores were poorer than those of patients with L-shaped tears. Surgeons should be aware of the differences in clinical outcome between L-shaped and reverse L-shaped rotator cuff tears. Cite this article: Bone Joint J 2022;104-B(3):394–400


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims. The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair. Patients and Methods. All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair. Results. The study group included 45 patients. Their mean age was 69 years (. sd. 8.6) and 27 patients (60%) were women. The mean ASES score improved from 43.1 to 76.6 two years postoperatively, and to 66.9 five years postoperatively. There was no significant difference between the outcomes at two years in the two groups (all p ≥ 0.05), although there was significantly more improvement in ASES scores in the control group (44.5 vs 33.4; p = 0.01). However, there was no significant difference between ASES scores at two and five years when baseline ASES scores were matched in the two groups (p = 0.42 at two years; p = 0.35 at five years). Conclusion. Significant improvements in ASES scores were seen following RSA in patients who had previously undergone rotator cuff repair. They had higher baseline ASES scores than those who had not previously undergone this surgery. However, there was no significant difference in outcomes between the two groups, two years postoperatively. Previous rotator cuff repair does not appear to affect the early outcome after RSA adversely


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1438 - 1445
1 Nov 2020
Jang YH Lee JH Kim SH

Aims. Scapular notching is thought to have an adverse effect on the outcome of reverse total shoulder arthroplasty (RTSA). However, the matter is still controversial. The aim of this study was to determine the clinical impact of scapular notching on outcomes after RTSA. Methods. Three electronic databases (PubMed, Cochrane Database, and EMBASE) were searched for studies which evaluated the influence of scapular notching on clinical outcome after RTSA. The quality of each study was assessed. Functional outcome scores (the Constant-Murley scores (CMS), and the American Shoulder and Elbow Surgeons (ASES) scores), and postoperative range of movement (forward flexion (FF), abduction, and external rotation (ER)) were extracted and subjected to meta-analysis. Effect sizes were expressed as weighted mean differences (WMD). Results. In all, 11 studies (two level III and nine level IV) were included in the meta-analysis. All analyzed variables indicated that scapular notching has a negative effect on the outcome of RTSA . Statistical significance was found for the CMS (WMD –3.11; 95% confidence interval (CI) –4.98 to –1.23), the ASES score (WMD –6.50; 95% CI –10.80 to –2.19), FF (WMD –6.3°; 95% CI –9.9° to –2.6°), and abduction (WMD –9.4°; 95% CI –17.8° to –1.0°), but not for ER (WMD –0.6°; 95% CI –3.7° to 2.5°). Conclusion. The current literature suggests that patients with scapular notching after RTSA have significantly worse results when evaluated by the CMS, ASES score, and range of movement in flexion and abduction. Cite this article: Bone Joint J 2020;102-B(11):1438–1445


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 663 - 667
1 Jun 2023
Youn S Rhee SM Cho S Kim C Lee J Rhee YG

Aims. The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect. Methods. A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs. Results. Statistically significant improvement from pre- to postoperation was seen in all VAS and ASES scores for each group, but no statistical differences were seen between the postoperative scores according to the differences in the features of the calcific deposits. When residual calcification was observed postoperatively, the mean ASES and VAS (rest) scores improved significantly to 95.0 (SD 5.6) and 0.0 (SD 0.0), respectively (p = 0.006 and p < 0.001), and did not differ from those who had the complete removal. Of 29 patients who had follow-up MRIs, six (20.7%) showed signs of an interstitial tear. This group’s mean postoperative ASES and VAS (rest) scores improved to excellent levels of 96.0 (SD 3.7) and 0.0 (SD 0.0), respectively, and were similar to those of the 23 patients with normal MRI appearances. Conclusion. Arthroscopic removal of calcific deposits without repairing the rotator cuff defect resulted in significant improvement in function and pain level, regardless of the deposit’s location, size, type, and whether or not complete excision was achieved. Despite leaving the defects unrepaired, in the limited number of patients with follow-up MRIs, 23 of 29 patients (79.3%) showed good healing, and the rest, who had persistent signs of interstitial defects on the MRIs, still had excellent outcomes. The removal of calcific deposits without repairing the cuff defects provided excellent outcomes. Cite this article: Bone Joint J 2023;105-B(6):663–667


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims. Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Methods. Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. Results. The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. Conclusion. We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353–359


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims. We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients. Methods. A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up. Results. We included 428 primary aTSAs with a mean follow-up of 2.4 years (SD 0.6). Our cohort consisted of 251 non-smokers, 138 former smokers who quit a mean 21 years (SD 14) prior to surgery (25 pack-years (SD 22)), and 39 current smokers (23 pack-years (SD 20)). At two- to four-year follow-up, former smokers had less favourable SPADI, SST, and FE strength compared to non-smokers, and current smokers had less favourable SPADI, SST, ASES score, UCLA score, Constant-Murley score, FE, abduction, and ER strength compared to non-smokers. Non-smokers exhibited higher revision-free survival rates at two, five, eight, and ten years postoperatively compared to former smokers and current smokers, who had similar rates. Conclusion. Our study suggests that smoking has a negative effect on aTSA functional outcomes that may persist even after quitting. Cite this article: Bone Joint J 2024;106-B(11):1263–1272


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 479 - 485
1 Apr 2022
Baker M Albelo F Zhang T Schneider MB Foster MJ Aneizi A Hasan SA Gilotra MN Henn RF

Aims. The purpose of this study was to assess the prevalence of depression and anxiety symptoms in patients undergoing shoulder surgery using the National Institutes of Health (NIH) Patient-Reported Outcomes Measurement Information System (PROMIS) Depression and Anxiety computer adaptive tests, and to determine the factors associated with more severe symptoms. Additionally, we sought to determine whether PROMIS Depression and Anxiety were associated with functional outcomes after shoulder surgery. Methods. This was a retrospective analysis of 293 patients from an urban population who underwent elective shoulder surgery from 2015 to 2018. Survey questionnaires included preoperative and two-year postoperative data. Bivariate analysis was used to identify associations and multivariable analysis was used to control for confounding variables. Results. Mean two-year PROMIS Depression and Anxiety scores significantly improved from preoperative scores, with a greater improvement observed in PROMIS Anxiety. Worse PROMIS Depression and Anxiety scores were also significantly correlated with worse PROMIS Physical Function (PF) and American Shoulder and Elbow Surgeons scores (ASES). After controlling for confounding variables, worse PROMIS Depression was an independent predictor of worse PROMIS PF, while worse PROMIS Anxiety was an independent predictor of worse PROMIS PF and ASES scores. Conclusion. Mean two-year PROMIS Depression and Anxiety scores improved after elective shoulder surgery and several patient characteristics were associated with these scores. Worse functional outcomes were associated with worse PROMIS Depression and Anxiety; however, more severe two-year PROMIS Anxiety was the strongest predictor of worse functional outcomes. Cite this article: Bone Joint J 2022;104-B(4):479–485


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 245 - 249
1 Feb 2017
Barnes LAF Kim HM Caldwell J Buza J Ahmad CS Bigliani LU Levine WN

Aims. Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. Patients and Methods. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. Results. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (. sd. ) 1.3) in the mini-open group; 8.9 (. sd. 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (. sd. 10.5) in mini-open group; mean 82.70 (. sd. 19.8) in the arthroscopic group; p = 0.048). Conclusion. The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245–9


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1232 - 1238
1 Sep 2013
Wiater BP Boone CR Koueiter DM Wiater JM

Some surgeons are reluctant to perform a reverse total shoulder arthroplasty (RTSA) on both shoulders because of concerns regarding difficulty with activities of daily living post-operatively as a result of limited rotation of the shoulders. Nevertheless, we hypothesised that outcomes and patient satisfaction following bilateral RTSA would be comparable to those following unilateral RTSA. A single-surgeon RTSA registry was reviewed for patients who underwent bilateral staged RTSA with a minimum follow-up of two years. A unilateral RTSA matched control was selected for each shoulder in those patients undergoing bilateral procedures. The Constant–Murley score (CMS), American Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Values (SSV), visual analogue scale (VAS) for pain, range of movement and strength were measured pre- and post-operatively. The mean CMS, ASES, SSV, VAS scores, strength and active forward elevation were significantly improved (all p < 0.01) following each operation in those undergoing bilateral procedures. The mean active external rotation (p = 0.63 and p = 0.19) and internal rotation (p = 0.77 and p = 0.24) were not significantly improved. The improvement in the mean ASES score after the first RTSA was greater than the improvement in its control group (p = 0.0039). The improvement in the mean CMS, ASES scores and active forward elevation was significantly less after the second RTSA than in its control group (p = 0.0244, p = 0.0183, and p = 0.0280, respectively). Pain relief and function significantly improved after each RTSA in those undergoing a bilateral procedure. Bilateral RTSA is thus a reasonable form of treatment for patients with severe bilateral rotator cuff deficiency, although inferior results may be seen after the second procedure compared with the first. Cite this article: Bone Joint J 2013;95-B:1232–8


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1077 - 1081
1 Aug 2014
Nuttall D Birch A Haines JF Trail IA

Resurfacing of the humeral head is commonly used within the UK to treat osteoarthritis (OA) of the shoulder. We present the results of a small prospective randomised study of this procedure using the Global CAP prosthesis with two different coatings, Porocoat and DuoFix hydroxyapatite (HA). We followed two groups of ten patients with OA of the shoulder for two years after insertion of the prosthesis with tantalum marker beads, recording pain, Constant–Murley and American Shoulder and Elbow Surgeons (ASES) outcome scores, and using radiostereometric analysis to assess migration. The outcomes were similar to those of other series, with significant reductions in pain (p = 0.003) and an improvement in the Constant (p = 0.001) and ASES scores (p = 0.006). The mean migration of the prosthesis three months post-operatively was 0.78 mm (0.51 to 1.69) and 0.72 mm (0.33 to 1.45) for the Porocoat and DuoFix groups, respectively. Analysis of variance indicated that the rate of migration reached a plateau after three months post-operatively in both groups. At follow-up of two years the mean migration was 1 mm (. sd. 1 (0.25 to 3.32)); in the Porocoat group and 0.8 mm (. sd. 0.4 (0.27 to 1.45)) in the DuoFix HA group. Significant migration of the prosthesis was seen in one patient who had received an anterior humeral bone graft. This prosthesis was later revised after 2.7 years. The addition of a coating of HA to the sintered surface does not improve fixation of this prosthesis. Cite this article: Bone Joint J 2014;96-B:1077–81


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims

Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty.

Methods

This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims

The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula.

Methods

We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims

Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients.

Methods

This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10).


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 191 - 195
1 Feb 2005
Mighell MA Dunham RC Rommel EA Frankle MA

We present six patients with chronic dislocation of the elbow who were treated by primary semiconstrained total elbow arthroplasty. All were women with a mean age of 65 years (51 to 76), the mean interval between dislocation and surgery was 17 weeks (5 to 52) and the mean follow-up 58 months (24 to 123). The most dramatic improvement was in function. The mean American Shoulder and Elbow Surgeon score was 5.2 times better (p < 0.001) and the mean total range of movement increased from 33° to 121° (p < 0.001) after operation. Three patients developed wear of polyethylene. One required revision for a periprosthetic fracture, and another required a bushing exchange. Primary semiconstrained elbow arthroplasty provides significant, predictable functional improvement. Potential solutions for wear of polyethylene include a different operative technique or design of implant. Despite the high incidence of such wear, total elbow arthroplasty should be considered as a viable treatment option for chronic dislocation of the elbow in elderly patients


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims

Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA.

Methods

MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 416 - 423
1 Apr 2022
Mourkus H Phillips NJ Rangan A Peach CA

Aims

The aim of this study was to investigate the outcome of periprosthetic fractures of the humerus and to assess the uniformity of the classifications used for these fractures (including those around elbow and/or shoulder arthroplasties) by performing a systematic review of the literature.

Methods

A systematic search was conducted using the National Institute for Health and Care Excellence Healthcare Databases Advance Search. For inclusion, studies had to report clinical outcomes following the management of periprosthetic fractures of the humerus. The protocol was registered on the PROSPERO database.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims

Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres.

Methods

We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 964 - 970
1 May 2021
Ling DI Schneider B Ode G Lai EY Gulotta LV

Aims

To investigate the impact of the Charlson and Elixhauser comorbidity indices on patient-reported outcomes measures (PROMs) following shoulder arthroplasty.

Methods

Patients undergoing total shoulder arthroplasty (TSA), reverse shoulder arthroplasty (RSA), or hemiarthroplasty (HA) from 2016 to 2018 were identified, along with the Charlson and Elixhauser comorbidities listed as their secondary diagnoses in the electronic medical records. Patients were matched to our institution’s registry to obtain their PROMs, including shoulder-specific (American Shoulder and Elbow Society (ASES) and Shoulder Activity Scale (SAS)) and general health scales (12-Item Short Form Survey (SF-12) and Patient-Reported Outcomes Measurement Information System-Pain Interference). Linear regression models adjusting for age and sex were used to evaluate the association between increasing number of comorbidities and PROM scores. A total of 1,817 shoulder arthroplasties were performed: 1,017 (56%) TSA, 726 (40%) RSA, and 74 (4%) HA. The mean age was 67 years (SD 10), and 936 (52%) of the patients were female.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1717 - 1724
1 Nov 2021
Singh HP Haque A Taub N Modi A Armstrong A Rangan A Pandey R

Aims

The main objective of this study was to examine whether the Oxford Shoulder Score (OSS) demonstrated floor or ceiling effects when used to measure outcomes following shoulder arthroplasty in a large national cohort. Secondary objectives were to assess its pain and function subscales, and to identify independent predictors for patients achieving a postoperative ceiling score following shoulder arthroplasty.

Methods

Secondary database analysis of the National Joint Registry (NJR), which included 48,270 patients undergoing shoulder arthroplasty, was conducted. The primary outcome measure was the OSS. Secondary outcome measures were the OSS-Function Component Subscale and OSS-Pain Component Subscale. Floor and ceiling effects were considered to be present if > 15% of patients scored either the lowest or highest possible score. Logistic regression analysis was used to identify independent predictors for scoring the highest possible OSS score postoperatively.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 958 - 963
3 May 2021
Nguyen NTV Martinez-Catalan N Songy CE Sanchez-Sotelo J

Aims

The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively.

Methods

A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time.


Aims

The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture.

Methods

This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1194 - 1199
14 Sep 2020
Lee H Kim E Kim Y

Aims

The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a rotator cuff tear and to evaluate the factors related to the changes.

Methods

A cohort of 162 patients who underwent isolated supraspinatus with the preservation of LHBT was enrolled and evaluated. The cross-sectional area (CSA) of the LHBT on MRI was measured in the bicipital groove, and preoperative to postoperative difference was calculated at least 12 months postoperatively. Second, postoperative changes in the LHBT including intratendinous signal change, rupture, dislocation, or superior labral lesions were evaluated with seeking of factors that were correlated with the changes or newly developed lesions after rotator cuff repair.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1190 - 1196
1 Sep 2017
Swarup I Henn CM Nguyen JT Dines DM Craig EV Warren RF Gulotta LV Henn III RF

Aims

Few studies have evaluated the relationship between patients’ pre-operative expectations and the outcome of orthopaedic procedures. Our aim was to determine the effect of expectations on the outcome after primary anatomical total shoulder arthroplasty (TSA). We hypothesised that patients with greater expectations would have better outcomes.

Patients and Methods

Patients undergoing primary anatomical TSA completed the Hospital for Special Surgery’s Shoulder Expectations Survey pre-operatively. The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS) for pain, fatigue, and general health scores were also collected pre-operatively and two years post-operatively. Pearson correlations were used to assess the relationship between the number of expectations and the outcomes. Differences in outcomes between those with higher and lower levels of expectations for each expectation were assessed by independent samples t-test. Multivariable linear regression analysis was used to control for potential confounding factors.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 761 - 766
1 Jun 2018
Holschen M Siemes M Witt K Steinbeck J

Aims

The reasons for failure of a hemirthroplasty (HA) when used to treat a proximal humeral fracture include displaced or necrotic tuberosities, insufficient metaphyseal bone-stock, and rotator cuff tears. Reverse total shoulder arthroplasty (rTSA) is often the only remaining form of treatment in these patients. The aim of this study was to evaluate the clinical outcome after conversions from a failed HA to rTSA.

Material and Methods

A total of 35 patients, in whom a HA, as treatment for a fracture of the proximal humerus, had failed, underwent conversion to a rTSA. A total of 28 were available for follow-up at a mean of 61 months (37 to 91), having been initially reviewed at a mean of 20 months (12 to 36) postoperatively. Having a convertible design, the humeral stem could be preserved in nine patients. The stem was removed in the other 19 patients and a conventional rTSA was implanted. At final follow-up, patients were assessed using the American Shoulder and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims

Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA.

Patients and Methods

We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10).


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 75 - 80
1 Jan 2016
Merolla G Chin P Sasyniuk TM Paladini P Porcellini G

Aims

We evaluated clinical and radiographic outcomes of total shoulder arthroplasty (TSA) using the second-generation Trabecular Metal (TM) Glenoid component. The first generation component was withdrawn in 2005 after a series of failures were reported. Between 2009 and 2012, 40 consecutive patients with unilateral TSA using the second-generation component were enrolled in this clinical study. The mean age of the patients was 63.8 years (40 to 75) and the mean follow-up was 38 months (24 to 42).

Methods

Patients were evaluated using the Constant score (CS), the American Shoulder and Elbow Surgeons (ASES) score and routine radiographs.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1562 - 1565
1 Nov 2015
Ersen A Atalar AC Birisik F Saglam Y Demirhan M

Only a few randomised, controlled studies have compared different non-operative methods of treatment of mid-shaft fractures of the clavicle.

In this prospective, randomised controlled study of 60 participants (mean age 31.6 years; 15 to 75) we compared the broad arm sling with the figure of eight bandage for the treatment of mid-shaft clavicle fractures. Our outcome measures were pain, Constant and American Shoulder and Elbow Surgeons scores and radiological union.

The mean visual analogue scale (VAS) pain score on the first day after treatment was significantly higher (VAS 1 6.8; 4 to 9) in the figure of eight bandage group than the broad arm sling group (VAS 1 5.6; 3 to 8, p = 0.034). A mean shortening of 9 mm (3 to 17) was measured in the figure of eight bandage group, versus 7.5 mm (0 to 24) in the broad arm sling group (p = 0.30).

The application of the figure of eight bandage is more difficult than of the broad arm sling, and patients experience more pain during the first day when treated with this option. We suggest the broad arm sling is preferable because of the reduction of early pain and ease of application.

Cite this article: Bone Joint J 2015;97-B:1562–5.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 674 - 679
1 May 2017
Nuttall D Birch A Haines JF Watts AC Trail IA

Aims

Radiostereometric analysis (RSA) allows an extremely accurate measurement of early micromotion of components following arthroplasty.

Patients and Methods

In this study, RSA was used to measure the migration of 11 partially cemented fluted pegged glenoid components in patients with osteoarthritis who underwent total shoulder arthroplasty using an improved surgical technique (seven men, four women, mean age 68). Patients were evaluated clinically using the American Shoulder and Elbow Surgeons (ASES) and Constant-Murley scores and by CT scans two years post-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 57 - 61
1 Jan 2011
Naveed MA Kitson J Bunker TD

The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching.

The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired t-test, p < 0.001) at final follow-up. The mean Oxford score was 44 (95% CI 40 to 51) pre-operatively and 23 (95% CI 18 to 28) (paired t-test, p < 0.001) at final follow-up.

The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven complications during the whole series, although only four patients required further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 83 - 91
1 Jan 2010
Moosmayer S Lund G Seljom U Svege I Hennig T Tariq R Smith H

In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the rotator cuff were randomly allocated to one of the two approaches. The primary outcome measure was the Constant score, and secondary outcome measures included the self-report section of the American Shoulder and Elbow Surgeons score, the Short Form 36 Health Survey and subscores for shoulder movement, pain, strength and patient satisfaction. Scores were taken at baseline and after six and 12 months by a blinded assessor. Nine patients (18%) with insufficient benefit from physiotherapy after at least 15 treatment sessions underwent secondary surgical treatment.

Analysis of between-group differences showed better results for the surgery group on the Constant scale (difference 13.0 points, p − 0.002), on the American Shoulder and Elbow surgeons scale (difference 16.1 points, p < 0.0005), for pain-free abduction (difference 28.8°, p = 0.003) and for reduction in pain (difference on a visual analogue scale −1.7 cm, p < 0.0005).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1184 - 1187
1 Sep 2007
Rispoli DM Sperling JW Athwal GS Schleck CD Cofield RH

We have examined the relief from pain and the functional outcome in 18 patients who underwent resection arthroplasty of the shoulder as a salvage operation between 1988 and 2002. The indications included failed shoulder replacement in 17, with infection in 13, and chronic septic arthritis in one. The mean follow-up was 8.3 years (2.5 to 16.6). Two intra-operative fractures of the humerus occurred, both of which healed.

The level of pain was significantly decreased (t-test, p < 0.001) but five patients continued to have moderate to severe pain. The mean active elevation was 70° (0° to 150°) postoperatively and represented an improvement from 39° (0° to 140°) (t-test, p = 0.003), but internal and external rotation were hardly changed. The mean number of positive answers on the 12-question Simple Shoulder Test was 3.1 (0 to 12) but the shoulder was generally comfortable when the arm was positioned at rest by the side. The mean post-operative American Shoulder and Elbow Surgeon’s score was 36 (8 to 73).

Despite applying this procedure principally to failed shoulder replacements, the results were similar to those reported in the literature for patients after severe fracture-dislocation. Reduction of pain is possible in one half to two-thirds of patients. The outcome of this operation in providing relief from pain cannot be guaranteed, but the shoulder is usually comfortable at rest, albeit with profound functional limitations.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture.

Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears.

Cite this article: Bone Joint J 2014;96-B:224–8.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 199 - 205
1 Feb 2013
Robinson PM Wilson J Dalal S Parker RA Norburn P Roy BR

This study reports the clinical and sonographic outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years and aimed to determine factors associated with re-tear. A total of 69 consecutive repairs were performed in 68 patients with a mean age of 77 years (70 to 86). Constant-Murley scores were collected pre-operatively and at one year post-operatively. The integrity of the repair was assessed using ultrasound. Re-tear was detected in 20 of 62 patients (32%) assessed with ultrasound. Age at operation was significantly associated with re-tear free survival (p = 0.016). The mean pre-operative Constant score was 23 (sd 14), which increased to 58 (sd 20) at one year post-operatively (paired t-test, p < 0.001). Male gender was significantly associated with a higher score at one year (p = 0.019).

We conclude that arthroscopic rotator cuff repair in patients aged ≥ 70 years is a successful procedure. The gender and age of the patient are important factors to consider when planning management.

Cite this article: Bone Joint J 2013;95-B:199–205.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 668 - 671
1 May 2010
Naqui SZ Rajpura A Nuttall D Prasad P Trail IA

This is a retrospective review of the results of the Acclaim total elbow replacement in 11 older patients aged ≥ 65 years with primary osteoarthritis of the elbow, with a mean follow-up of 57.6 months (30 to 86.4).

Significant reductions in pain and improvement in range of movement and function were recorded. Radiological review revealed two patients with 1 mm lucencies in a single zone, and one patient with 1 mm lucencies in two zones. No components required revision. There were no deep infections, dislocations or mechanical failures. Complications included one intra-operative medial condylar fracture and one post-operative transient ulnar neuropathy, which resolved.

This study demonstrates that the Acclaim prosthesis provides good symptomatic relief and improvement of function in patients with primary osteoarthritis, with low rates of loosening or other complications. This prosthesis can therefore be considered for patients aged ≥ 65 years with primary osteoarthritis of the elbow.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 757 - 761
1 Jun 2009
Nuttall D Haines JF Trail IA

In a prospective study between 2000 and 2005, 22 patients with primary osteoarthritis of the shoulder had a total shoulder arthroplasty with a standard five-pegged glenoid component, 12 with non-offset humeral head and ten with offset humeral head components. Over a period of 24 months the relative movement of the glenoid component with respect to the scapula was measured using radiostereometric analysis.

Nine glenoids needed reaming for erosion. There was a significant increase in rotation about all three axes with time (p < 0.001), the largest occurring about the longitudinal axis (anteversion-retroversion), with mean values of 3.8° and 1.9° for the non-offset and offset humeral head eroded subgroups, respectively. There was also a significant difference in rotation about the anteversion-retroversion axis (p = 0.01) and the varus-valgus (p < 0.001) z-axis between the two groups. The offset humeral head group reached a plateau at early follow-up with rotation about the z-axis, whereas the mean of the non-offset humeral head group at 24 months was three times greater than that of the offset group accounting for the highly significant difference between them.