Advertisement for orthosearch.org.uk
Results 1 - 20 of 22
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.

Cite this article: Bone Joint J 2024;106-B(11):1321–1326.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims

The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula.

Methods

We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 958 - 963
3 May 2021
Nguyen NTV Martinez-Catalan N Songy CE Sanchez-Sotelo J

Aims

The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively.

Methods

A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1491 - 1492
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims

Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA.

Patients and Methods

We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10).


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 976 - 983
1 Jul 2016
Streubel PN Simone JP Morrey BF Sanchez-Sotelo J Morrey ME

Aims

We describe the use of a protocol of irrigation and debridement (I& D) with retention of the implant for the treatment of periprosthetic infection of a total elbow arthroplasty (TEA). This may be an attractive alternative to staged re-implantation.

Patients and Methods

Between 1990 and 2010, 23 consecutive patients were treated in this way. Three were lost to follow-up leaving 20 patients (21 TEAs) in the study. There were six men and 14 women. Their mean age was 58 years (23 to 76). The protocol involved: component unlinking, irrigation and debridement (I& D), and the introduction of antibiotic laden cement beads; organism-specific intravenous antibiotics; repeat I& D and re-linkage of the implant if appropriate; long-term oral antibiotic therapy.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1681 - 1687
1 Dec 2014
Foruria AM Lawrence TM Augustin S Morrey BF Sanchez-Sotelo J

We retrospectively reviewed 89 consecutive patients (45 men and 44 women) with a mean age at the time of injury of 58 years (18 to 97) who had undergone external fixation after sustaining a unilateral fracture of the distal humerus. Our objectives were to determine the incidence of heterotopic ossification (HO); identify risk factors associated with the development of HO; and characterise the location, severity and resultant functional impairment attributable to the presence of HO.

HO was identified in 37 elbows (42%), mostly around the humerus and along the course of the medial collateral ligament. HO was hazy immature in five elbows (13.5%), mature discrete in 20 (54%), extensive mature in 10 (27%), and complete bone bridges were present in two elbows (5.5%). Mild functional impairment occurred in eight patients, moderate in 27 and severe in two. HO was associated with less extension (p = 0.032) and less overall flexion-to-extension movement (p = 0.022); the flexion-to-extension arc was < 100º in 21 elbows (57%) with HO compared with 18 elbows (35%) without HO (p = 0.03). HO was removed surgically in seven elbows.

The development of HO was significantly associated with sustaining a head injury (p = 0.015), delayed internal fixation (p = 0.027), the method of fracture fixation (p = 0.039) and the use of bone graft or substitute (p = 0.02).HO continues to be a substantial complication after internal fixation for distal humerus fractures.

Cite this article: Bone Joint J 2014;96-B:1681–7.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 526 - 529
1 Apr 2014
Giuseffi SA Streubel P Sperling J Sanchez-Sotelo J

Short uncemented humeral stems can preserve humeral bone stock and facilitate revision surgery but may be prone to malalignment or loosening, especially when used in reverse total shoulder replacement (TSR). We undertook a retrospective review of 44 patients with a mean age of 76 years (59 to 92) who underwent primary reverse TSR with a short uncemented humeral stem. There were 29 females. The indications for joint replacement included cuff tear associated arthropathy (33), avascular necrosis (six), post-traumatic arthritis (two), and inflammatory arthritis (three). At a mean follow-up of 27 months (24 to 40), pain was rated as mild or none in 43 shoulders (97.7%). The mean active elevation improved from 54° (sd 20°) to 142° (sd 25°) and the mean active external rotation from 14° (sd 13°) to 45° (sd 9°). The outcome, as assessed by the modified Neer score, was excellent in 27 (61.3%), satisfactory in 15 (34.1%), and unsatisfactory in two shoulders (4.5%). Stems were well-positioned, without evidence of significant valgus or varus malalignment in 42 TSRs (95.5%). There was no radiological evidence of loosening of the humeral stem in any patient; 13 TSRs (29.5%) had evidence of proximal humeral remodelling and scapular notching was noted in three (6.8%).

Cite this article: Bone Joint J 2014;96-B:526–9.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 82 - 87
1 Jan 2014
Duquin TR Jacobson JA Schleck CD Larson DR Sanchez-Sotelo J Morrey BF

Treatment of an infected total elbow replacement (TER) is often successful in eradicating or suppressing the infection. However, the extensor mechanism may be compromised by both the infection and the surgery. The goal of this study was to assess triceps function in patients treated for deep infection complicating a TER. Between 1976 and 2007 a total of 217 TERs in 207 patients were treated for infection of a TER at our institution. Superficial infections and those that underwent resection arthroplasty were excluded, leaving 93 TERs. Triceps function was assessed by examination and a questionnaire. Outcome was measured using the Mayo Elbow Performance Score (MEPS).

Triceps weakness was identified in 51 TERs (49 patients, 55%). At a mean follow-up of five years (0.8 to 34), the extensor mechanism was intact in 13 patients, with the remaining 38 having bone or soft-tissue loss. The mean MEPS was 70 points (5 to 100), with a mean functional score of 18 (0 to 25) of a possible 25 points.

Infection following TER can often be eradicated; however, triceps weakness occurs in more than half of the patients and may represent a major functional problem.

Cite this article: Bone Joint J 2014;96-B:82–7.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (sd 1.6); most recent VAS 2.2 (sd 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (sd 27.3) to 97.0° (sd 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results.

Cite this article: Bone Joint J 2013;95-B:668–72.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 86 - 92
1 Jan 2012
Jeon IH Sanchez-Sotelo J Zhao K An KN Morrey BM

We undertook this study to determine the minimum amount of coronoid necessary to stabilise an otherwise intact elbow joint. Regan–Morrey types II and III, plus medial and lateral oblique coronoid fractures, collectively termed type IV fractures, were simulated in nine fresh cadavers. An electromagnetic tracking system defined the three-dimensional stability of the ulna relative to the humerus. The coronoid surface area accounts for 59% of the anterior articulation. Alteration in valgus, internal and external rotation occurred only with a type III coronoid fracture, accounting for 68% of the coronoid and 40% of the entire articular surface. A type II fracture removed 42% of the coronoid articulation and 25% of the entire articular surface but was associated with valgus and external rotational changes only when the radial head was removed, thereby removing 67% of the articular surface.

We conclude that all type III fractures, as defined here, are unstable, even with intact ligaments and a radial head. However, a type II deficiency is stable unless the radial head is removed. Our study suggests that isolated medial-oblique or lateral-oblique fractures, and even a type II fracture with intact ligaments and a functional radial head, can be clinically stable, which is consistent with clinical observation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 378 - 386
1 Mar 2011
Foruria AM de Gracia MM Larson DR Munuera L Sanchez-Sotelo J

Our aim was to determine the effect of the initial pattern of fracture and the displacement of fragments on the outcome of proximal humeral fractures treated conservatively. We followed 93 consecutive patients prospectively for one year. Final movement and strength were compared with those of the contralateral side. The final American Shoulder and Elbow Society score and the Disabilities of Arm, Shoulder and Hand and Short-Form 36 questionnaires were compared with those provided by the patient on the day of the injury. Radiographs and CT scans with three-dimensional reconstruction were obtained in all patients. The pattern of the fracture and the displacement of individual fragments were analysed and correlated with the final outcome. There were two cases of nonunion and six of avascular necrosis. The majority of the fractures (84 patients; 90%) followed one of the following four patterns: posteromedial (varus) impaction in 50 patients (54%), lateral (valgus) impaction in 13 (14%), isolated greater tuberosity in 15 (16%), and anteromedial impaction fracture in six (6%). Head orientation, impaction of the surgical neck and displacement of the tuberosity correlated strongly with the outcome.

In fractures with posteromedial impaction, a poor outcome was noted as the articular surface displaced inferiorly increasing its distance from the acromion. A poorer outcome was noted as a fractured greater tuberosity displaced medially overlapping with the posterior articular surface. Lateral impaction fractures had a worse outcome than other patterns of fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 274 - 276
1 Feb 2011
Chan JHH Ballal MS Dheerendra S Sanchez-Ballester J Pydisetty RV

Injury to the sciatic nerve following closed manipulation of a dislocated total hip replacement is rare. We present such a case in an elderly patient with partial recovery following exploration and release of the nerve.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 661 - 667
1 May 2010
van Riet RP Sanchez-Sotelo J Morrey BF

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 75 - 81
1 Jan 2009
Cil A Veillette CJH Sanchez-Sotelo J Sperling JW Schleck C Cofield RH

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3).

Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p < 0.0001). The mean active abduction improved from 88° to 107° (p < 0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative complications included cement extrusion in eight cases, fracture of the shaft of the humerus is two and of the tuberosity in four. There were four re-operations, one for recurrent humeral loosening, with 89% survival free of re-operations at ten years.

Revision surgery for aseptic loosening of the humeral component provides reliable pain relief and modest improvement of movement, although there is a substantial risk of intra-operative complications. Revision to a total shoulder replacement gives better results than to a hemiarthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 937 - 939
1 Jul 2005
Richards JD Sanchez-Ballester J Jones RK Darke N Livingstone BN

In this cross-over study, we evaluated two types of knee brace commonly used in the conservative treatment of osteoarthritis of the medial compartment. Twelve patients confirmed radiologically as having unilateral osteoarthritis of the medial compartment (Larsen grade 2 to grade 4) were studied. Treatment with a simple hinged brace was compared with that using a valgus corrective brace. Knee kinematics, ground reaction forces, pain and function were assessed during walking and the Hospital for Special Surgery scores were also determined.

Significant improvements in pain, function, and loading and propulsive forces were seen with the valgus brace. Treatment with a simple brace showed only significant improvements in loading forces. Our findings suggest that although both braces improved confidence and function during gait, the valgus brace showed greater benefit.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 54 - 61
1 Jan 2005
Sanchez-Sotelo J Morrey BF O’Driscoll SW

We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15).

Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04).

Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 674 - 681
1 Jul 2004
Robinson JR Sanchez-Ballester J Bull AMJ Thomas RDWM Amis AA

We have reviewed the literature on the anatomy of the posteromedial peripheral ligamentous structures of the knee and found differing descriptions. Our aim was to clarify the differing descriptions with a simplified interpretation of the anatomy and its contribution to the stability of the knee.

We dissected 20 fresh-frozen cadaver knees and the anatomy was recorded using video and still digital photography. The anatomy was described by dividing the medial collateral ligament (MCL) complex into thirds, from anterior to posterior and into superficial and deep layers. The main passive restraining structures of the posteromedial aspect of the knee were found to be superficial MCL (parallel, longitudinal fibres), the deep MCL and the posteromedial capsule (PMC). In the posterior third, the superficial and deep layers blend. Although there are oblique fibres (capsular condensations) running posterodistally from femur to tibia, no discrete ligament was seen. In extension, the PMC appears to be an important functional unit in restraining tibial internal rotation and valgus.

Our aim was to clarify and possibly simplify the anatomy of the posteromedial structures. The information would serve as the basis for future biomechanical studies to investigate the contribution of the posteromedial structures to joint stability.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1116 - 1120
1 Nov 2002
Sanchez-Sotelo J Morrey BF

Seven patients with chronic insufficiency of the triceps were treated by either a rotation flap using anconeus (4) or an allograft of tendo Achillis (3). The latter procedure was selected for patients with a large defect in whom the anconeus muscle had been devitalised. Five disruptions were in patients who had previously undergone an elbow replacement. The patients were assessed for subjective satisfaction, pain, range of movement and strength, and the results were graded using the Mayo Elbow Performance Score (MEPS). The mean follow-up was for 33 months (9 to 63).

One rotation flap failed six months after operation. At the most recent follow-up, the remaining six patients had no or slight pain, restoration of a functional arc of movement and normal or slightly decreased power of extension. All six were satisfied with the outcome and were able to resume their daily activities with no limitations other than those imposed by the previous elbow replacement. The final MEPS was 100 points in five patients and 75 in one.