Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Applied filters
The Bone & Joint Journal
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 55 - 57
1 Jan 1989
Ralis Z

The effect of storage at sub-zero temperatures and subsequent thawing was investigated in dissected muscles, tendons, limbs and spines. Freezing caused a noticeable shortening of muscles which when thawed could easily be elongated; the same effects, though less pronounced, were observed with tendons. During freezing, myotomy or tenotomy led to the development of a striking deformity owing to unopposed shortening of the opposing muscles. After thawing, all frozen specimens containing muscles and joints showed an increased range of passive movements, easily demonstrable by mild tensile forces.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 111 - 117
1 Jan 1989
Mackie I Ralis Z Leyshon R Lane J Watkins G Berry P

Twenty-three of 46 patients, aged 56 to 95 years, with fracture of the femoral neck (FNF) completed the first trial of 10 months treatment with oral sodium fluoride 60 mg and calcium 1800 mg on alternate days and 1 micrograms of vitamin D1 daily. Pre-treatment and post-treatment biopsy specimens and microradiographs of the iliac crest and metacarpal and spinal radiographs were evaluated together with biopsy material from seven untreated age-matched controls with FNF. In 17 patients the treatment improved the amount and quality of trabecular bone. Cortical thickness increased in nine patients and there were no losses of amount or mineralisation. The treatment was well tolerated by most patients and there were no major side-effects or signs of bone demineralisation. The study also revealed an unexpected rapid post-fracture deterioration of bone tissue in untreated FNF patients; thus there is an increased risk of further fractures which calls for the use of an effective treatment to increase bone mass.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 313 - 316
1 Mar 1985
Howard C McKibbin B Ralis Z

We have studied the use of filamentous polyglycolic acid (Dexon) for the induction of neotendon in the calcaneal tendon of sheep. Uniformly good results were obtained, with the formation of a thick neotendon. However, in a control group the power of spontaneous regeneration of the tendon was studied; it was found that, provided overlengthening of the gap was prevented, an equally good tendon resulted. It is concluded that this particular model is not an appropriate one for testing neotendon induction, despite its use for this purpose in the past. The favourable results of using filamentous polyglycolic acid as a tendon replacement suggest that it should be further investigated (in a more suitable model) since it may well have useful clinical applications.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 196 - 200
1 Mar 1984
Leyshon R Channon G Jenkins D Ralis Z

Sixty-three knees with chronic ligamentous instability treated with flexible carbon fibre are reviewed. Assessment was by pre-operative and postoperative grading of function in work and sport, together with a subjective evaluation of the result based on stability. Fifteen knees had collateral repairs, seven had cruciate repairs and 41 had combined collateral and cruciate repairs. Overall, 71% of knees showed improvement in function and 67% had good or excellent results subjectively. Clinical examination did not correlate well with the patient's evaluation of the result. Nineteen unselected cases with intra-articular (cruciate) carbon fibre had arthroscopies. Infiltration of collagen tissues into the cruciate replacement was a slower process than at the extra-articular (collateral) site. There was no clinical or macroscopic evidence of synovitis but microscopically there was evidence of synovial irritation.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 269 - 275
1 Jun 1982
Catterall A Pringle J Byers P Fulford G Kemp H Dolman C Bell H McKibbin B Ralis Z Jensen O Lauritzen J Ponseti I Ogden J

There are differences of opinion about the pathogenesis of Perthes' disease. All are agreed that it is due to ischaemia, but the cause of this and the size and number of infarctions are in dispute. Through the generosity of the contributors six whole femoral heads and core biopsies of five other cases have been studied radiographically and histologically. The findings ranged from an ischaemic arrest of ossification in the capital articular cartilage without infarction to multiple complete infarctions of the epiphysial bone. The ensuing reparative process contributes to the pathology, which is of a range to warrant grading or grouping.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 112 - 114
1 Feb 1982
Tayton K Phillips G Ralis Z


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 561 - 566
1 Nov 1978
McKibbin B Ralis Z

Allografts of immature joint cartilage from the knees of lambs were transferred heterotopically into an intramuscular site in animals which had been presensitised by two sets of skin grafts from the same donors. All of these grafts were found to be largely destroyed by the immune response as early as four weeks after transfer. Similar grafts transferred orthotopically into the knees of the recipients, on the other hand, were found to be thriving even after twelve weeks and evoked a minimal response. Heterotopic autografts also provoked a mild though non-specific inflammatory reaction which the orthotopic grafts did not. It is concluded that cartilage matrix is capable of protecting grafts to a remarkable degree even from a severe immunological assault but only when the nutrition is adequate. It is suggested that the conflicting results of similar previous experiments may be explained by variations in the nutritional state of the graft which may be affected by the technique of transplantation used.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 53 - 57
1 Feb 1977
Jenkins D Forster I McKibbin B Ralis Z

Experiments have been performed on rabbits and sheep which demonstrate that pure carbon, in a flexible and filamentous form of great strength, can be used successfully to induce the formation of new tendons. A concept fundamentally different from that underlying the use of other artificial tendon replacements is involved, in which rapidly developing tendon-like tissue is induced to form around the implant. This gradually takes over the function of the implant. The early results in rabbits and the late results in sheep suggest that filamentous carbon may have a place in the replacement of the calcaneal tendon and the collateral ligaments of the knee.