Advertisement for orthosearch.org.uk
Results 1 - 20 of 388
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1347 - 1353
1 Oct 2009
Grob D Bartanusz V Jeszenszky D Kleinstück FS Lattig F O’Riordan D Mannion AF

In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome Measures Index. Blood loss and operating time were significantly lower in the translaminar screw group (p < 0.01). The complication rates were similar in each group (2% to 4%). In all, 91% of the patients returned their questionnaire at two-years. The groups did not differ in Core Outcome Measures Index score reduction, 3.6 (. sd. 2.5) (translaminar screws) vs 4.0 (. sd. 2.8) (transforaminal lumbar interbody fusion) (p = 0.39); ‘good’ global outcomes, 78% (translaminar screws) vs 78% (transforaminal lumbar interbody fusion) (p = 0.99) or satisfaction with treatment, 82% (translaminar screws) vs 86% (transforaminal lumbar interbody fusion) (p = 0.52). The two fusion techniques differed markedly in their extent and the cost of the implants, but were associated with almost identical patient-orientated outcomes. Extensive three-point stabilisation is not always required to achieve satisfactory patient-orientated results at two years


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 545 - 549
1 Apr 2010
Li W Chi Y Xu H Wang X Lin Y Huang Q Mao F

We reviewed the outcome of a retrospective case series of eight patients with atlantoaxial instability who had been treated by percutaneous anterior transarticular screw fixation and grafting under image-intensifier guidance between December 2005 and June 2008. The mean follow-up was 19 months (8 to 27). All eight patients had a solid C1–2 fusion. There were no breakages or displacement of screws. All the patients with pre-operative neck pain had immediate relief from their symptoms or considerable improvement. There were no major complications. Our preliminary clinical results suggest that percutaneous anterior transarticulation screw fixation is technically feasible, safe, useful and minimally invasive when using the appropriate instruments allied to intra-operative image intensification, and by selecting the correct puncture point, angle and depth of insertion


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1110 - 1117
12 Oct 2022
Wessling M Gebert C Hakenes T Dudda M Hardes J Frieler S Jeys LM Hanusrichter Y

Aims. The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants. Methods. A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up. Results. Mean CT defined discrepancy (Δ) between planned and achieved AV and IC was 4.5° (SD 3°; 0° to 12°) and 4° (SD 3.5°; 1° to 12°), respectively. Malpositioning (Δ > 10°) occurred in five hips (10.6%). Native COR reconstruction was planned in 42 cases (93%), and the mean 3D deviation vector was 15.5 mm (SD 8.5; 4 to 35). There was no significant influence in malpositioning found for femoral stem retention, surgical approach, or fixation method. Conclusion. At short-term follow-up, we found that PPR offers a viable solution for rTHA in cases with massive acetabular bone loss, as highly accurate positioning can be accomplished with meticulous planning, achieving anatomical reconstruction. Accuracy of achieved placement contributed to reduced complications with no injury to vital structures by screw fixation. Cite this article: Bone Joint J 2022;104-B(10):1110–1117


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1101 - 1106
1 Aug 2012
Jindal N Sankhala SS Bachhal V

The purpose of this study was to determine whether patients with a burst fracture of the thoracolumbar spine treated by short segment pedicle screw fixation fared better clinically and radiologically if the affected segment was fused at the same time. A total of 50 patients were enrolled in a prospective study and assigned to one of two groups. After the exclusion of three patients, there were 23 patients in the fusion group and 24 in the non-fusion group. Follow-up was at a mean of 23.9 months (18 to 30). Functional outcome was evaluated using the Greenough Low Back Outcome Score. Neurological function was graded using the American Spinal Injury Association Impairment Scale. Radiological outcome was assessed on the basis of the angle of kyphosis. Peri-operative blood transfusion requirements and duration of surgery were significantly higher in the fusion group (p = 0.029 and p < 0.001, respectively). There were no clinical or radiological differences in outcome between the groups (all outcomes p > 0.05). The results of this study suggest that adjunctive fusion is unnecessary when managing patients with a burst fracture of the thoracolumbar spine with short segment pedicle screw fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 484 - 489
1 May 1995
Won C Hearn T Tile M

Adult human cadaver pelves were tested to determine micromotion at the prosthesis-bone interface in cementless hemispherical acetabular components during simulated single-limb stance. The micromotion of non-press-fit components with screw fixation in response to cyclic loads to a maximum of 1500N was compressive (interface closing) at the superior iliac rim and distractive (interface opening) at the inferior ischial rim; that of press-fit components was compressive all around the acetabular rim regardless of screw fixation. Adding screws to the component decreased the micromotion at the site of the screw, but sometimes increased it at the opposite side. Two dome screws with the press-fit component decreased the micromotion at the superior iliac rim but at the inferior ischial rim there was either no change or increased movement. A press-fit cup shows less micromotion than a non-press-fit cup with screw fixation. The addition of screws to a press-fit cup does not necessarily increase the initial stability


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 972 - 976
1 Nov 1991
Grob D Jeanneret B Aebi M Markwalder T

We reviewed 161 patients, from four centres in Switzerland, who had undergone posterior fusion of the upper cervical spine with transarticular screw fixation of the atlanto-axial joints. They were followed up for a mean 24.6 months. The vertebral artery and the medulla escaped injury and only 5.9% of the complications were directly related to the screws. The rate of pseudarthrosis was 0.6%


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 138 - 142
1 Jan 1991
Wozasek G Moser K

We describe a percutaneous technique for screw fixation of all types of fractures of the scaphoid. During a 15-year period ending in 1984, 280 cases were treated by this method; 198 of them returned for evaluation in 1986 and comprise the material for this report. After a mean postoperative time of 82 months, 89% of the recent fractures had united as well as 81.8% of those with delayed or nonunion and 42.8% of those with sclerotic nonunion


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 432 - 441
1 Aug 1972
Maudsley RH Chen SC

1. A modification of the McLaughlin technique of lag screw fixation of the fractured scaphoid is described. 2. Fifty-six patients operated upon between 1956 and 1966 have been reviewed and their fractures classified under the headings recent, delayed union and non-union. 3. Plaster casts were avoided and early return to work encouraged; 95 per cent did so within two months. 4. Of twenty-two recent fractures, including three perilunar trans-scaphoid dislocations, nineteen united; of fifteen showing delayed union, eight united: and of nineteen cases of non-union, only two united. 5. The function of the wrist in the seventeen cases of persistent non-union stabilised by lag-screw was surprisingly good; only one patient has required arthrodesis to date. 6. The indications and contra-indications for the operation are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 66 - 71
1 Jan 2008
McQueen MM Gelbke MK Wakefield A Will EM Gaebler C

We randomly allocated 60 consecutive patients with fractures of the waist of the scaphoid to percutaneous fixation with a cannulated Acutrak screw or immobilisation in a cast. The range of movement, the grip and pinch strength, the modified Green/O’Brien functional score, return to work and sports, and radiological evidence of union were evaluated at each follow-up visit. Patients were followed sequentially for one year. Those undergoing percutaneous screw fixation showed a quicker time to union (9.2 weeks vs 13.9 weeks, p < 0.001) than those treated with a cast. There was a trend towards a higher rate of nonunion in the non-operative group, although this was not statistically significant. Patients treated by operation had a more rapid return of function and to sport and full work compared with those managed conservatively. There was a very low complication rate. We recommend that all active patients should be offered percutaneous stabilisation for fractures of the waist of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 98 - 100
1 Jan 1995
Mintzer C Waters P Simmons B

In children, nonunion of fractures of the waist of the scaphoid is uncommon. Treatment has included bone grafting without internal fixation, bone grafting with Kirschner-wire fixation, and screw fixation without bone grafting. We report the successful use of Herbert screw fixation and iliac-crest bone grafting in five cases, all of which healed without further surgery. At an average follow-up of 3.3 years, the range of motion, grip strength, carpal stability, and radiological appearances were all excellent


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 124 - 127
1 Jan 1984
Leyshon A Ireland J Trickey E

A simple technique for screw fixation of the carpal scaphoid in cases of delayed union and non-union is described. The results obtained in 32 patients treated by this method are reported. The average follow-up was three years ranging from 10 months to 12 years. Union was obtained in 28 patients. The causes of failure to unite are discussed and the advantages of the reported method over other techniques such as bone grafting are stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 291 - 294
1 Mar 1991
Ballmer F Gerber C

Five consecutive unstable fractures of the distal third of the clavicle were treated by indirect open reduction and internal fixation using a temporary Bosworth-type screw. Coracoclavicular fixation provided and maintained reduction of the fracture. Healing occurred uneventfully within nine weeks in all cases. The screw was removed under local anaesthesia after healing of the fracture and there were no surgical complications. Shoulder function was restored to the pre-injury level. Temporary coracoclavicular screw fixation appears to be a valuable alternative for the treatment of type II fractures of the distal third of the clavicle


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1138 - 1141
1 Nov 2002
Blundell CM Nicholson P Blackney MW

Over a period of one year we treated nine fractures of the sesamoid bones of the hallux, five of which were in the medial sesamoid. All patients had symptoms on exercise, but only one had a recent history of injury. The mean age of the patients was 27 years (17 to 45) and there were six men. The mean duration of symptoms was nine months (1.5 to 48). The diagnosis was based on clinical and radiological investigations. We describe a new surgical technique for percutaneous screw fixation for these fractures using a Barouk screw. All the patients were assessed before and after surgery using the American Orthopaedic Foot and Ankle Society Hallux Score (AOFAS). There was a statistically significant improvement in the mean score from 46.9 to 80.7 (p = 0.0003) after fixation of the fracture with a rapid resolution of symptoms. All patients returned to their previous level of activity by three months. We believe that this relatively simple technique is an excellent method of treatment in appropriately selected patients


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 418 - 421
1 May 1997
Inoue G Shionoya K

We describe a semi-closed method of Herbert screw fixation for acute fractures of the scaphoid. All 40 patients treated achieved solid union with satisfactory wrist function. This technique gave a significantly shorter time to union and allowed an earlier return to manual labour compared with conservative treatment. There were no complications. Semi-closed insertion requires considerable skill, but produces consistently satisfactory results after minimal exposure of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 565 - 567
1 Dec 1982
Howard C Davies R

Ten cases of a complication of Garden screw fixation of subcapital fracture, namely subtrochanteric fracture through the lower screw hole, are presented. Their possible aetiology, prevention and difficulties in management are discussed. It is recommended that, during the insertion of Garden screws, care should be taken to avoid multiple attempts at passing the guide wire. If subtrochanteric fracture occurs internal fixation with a nail plate or screw plate is advised. Ideally the nail or screw should be inserted along the track of one of the existing screws


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1197 - 1198
1 Nov 2004
Burke JG Sher JL

We report the case of a 13-year-old obese child presenting with bilateral stable slipped capital femoral epiphyses, which were managed by percutaneous single screw fixation in situ under image intensifier control using arthrography


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 530 - 534
1 Jul 1996
Daly K Gill P Magnussen PA Simonis RB

We reviewed 26 consecutive men of mean age 28 years who had had wedge bone grafting and Herbert screw fixation for symptomatic established nonunion of the waist of the scaphoid. The period between injury and operation averaged 30 months (10 to 96), and 11 of the 26 patients had had previous operations, seven with bone grafts. At a mean follow-up of 14 months (6 to 42) 25 fractures (95%) had united at a median time of four months. Symptoms were improved in all patients. The outcome was not related to the time between injury and surgery or to pre-existing degenerative changes. Previous surgery carried a worse prognosis. The technique is difficult but can achieve union even when previous surgery and bone grafting have failed. The usual result is improved function and some relief of pain


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1650 - 1653
1 Dec 2007
Tsiridis E Upadhyay N Gamie Z Giannoudis PV

Sacral insufficiency fractures are traditionally treated with bed rest and analgesia. The importance of early rehabilitation is generally appreciated; but pain frequently delays this, resulting in prolonged hospital stay and the risk of complications related to immobility. We describe three women with sacral insufficiency fractures who were treated with percutaneous sacroiliac screws and followed up for a mean of 18 months (12 to 24). They had immediate pain relief, uncomplicated rehabilitation and uneventful healing.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1662 - 1666
1 Dec 2013
Parker L Garlick N McCarthy I Grechenig S Grechenig W Smitham P

The AO Foundation advocates the use of partially threaded lag screws in the fixation of fractures of the medial malleolus. However, their threads often bypass the radiodense physeal scar of the distal tibia, possibly failing to obtain more secure purchase and better compression of the fracture.

We therefore hypothesised that the partially threaded screws commonly used to fix a medial malleolar fracture often provide suboptimal compression as a result of bypassing the physeal scar, and proposed that better compression of the fracture may be achieved with shorter partially threaded screws or fully threaded screws whose threads engage the physeal scar.

We analysed compression at the fracture site in human cadaver medial malleoli treated with either 30 mm or 45 mm long partially threaded screws or 45 mm fully threaded screws. The median compression at the fracture site achieved with 30 mm partially threaded screws (0.95 kg/cm2 (interquartile range (IQR) 0.8 to 1.2) and 45 mm fully threaded screws (1.0 kg/cm2 (IQR 0.7 to 2.8)) was significantly higher than that achieved with 45 mm partially threaded screws (0.6 kg/cm2 (IQR 0.2 to 0.9)) (p = 0.04 and p < 0.001, respectively). The fully threaded screws and the 30mm partially threaded screws were seen to engage the physeal scar under an image intensifier in each case.

The results support the use of 30 mm partially threaded or 45 mm fully threaded screws that engage the physeal scar rather than longer partially threaded screws that do not. A 45 mm fully threaded screw may in practice offer additional benefit over 30 mm partially threaded screws in increasing the thread count in the denser paraphyseal region.

Cite this article: Bone Joint J 2013;95-B:1662–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 181 - 181
1 Jan 1998
COONEY WP