Advertisement for orthosearch.org.uk
Results 1 - 20 of 389
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score. Results. At final follow-up, the knee was unstable in 9/18 patients (50%) in the osteoarticular allograft group and 2/15 patients (13%) in the rAPC group (p = 0.026). The median range of motion (ROM) of the knee was 117° (IQR 115° to 120°) in the osteoarticular allograft group and 100° (IQR 95° to 105°) in the rAPC group (p < 0.001). The median MSTS score was 25 (IQR 23 to 26) in the osteoarticular allograft group and 28 (IQR 26 to 29) in the rAPC group (p = 0.007). Osteoarthritic change was detected in 11/18 patients (61%) in the osteoarticular allograft group and in 4/15 (26%) patients in the rAPC group (p = 0.048). Conclusion. In our series, a resurfaced allograft-prosthesis composite provided better knee stability and function, with a lower rate of osteoarthritis; an osteoarticular allograft was associated with better knee ROM. Cite this article: Bone Joint J 2022;104-B(10):1174–1179


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1106 - 1111
1 Aug 2018
Knapik DM Sanders JO Gilmore A Weber DR Cooperman DR Liu RW

Aims. Using 90% of final height as a benchmark, we sought to develop a quick, quantitative and reproducible method of estimating skeletal maturity based on topographical changes in the distal femoral physis. Patients and Methods. Serial radiographs of the distal femoral physis three years prior to, during, and two years following the chronological age associated with 90% of final height were analyzed in 81 healthy children. The distance from the tip of the central peak of the distal femoral physis to a line drawn across the physis was normalized to the physeal width. Results. A total of 389 radiographs of the distal femur with corresponding Greulich and Pyle bone ages and known chronological ages were measured. Children reached 90% of final height at a mean age of 11.3 years (. sd. 0.8) for girls and 13.2 years (. sd. 0.6) for boys. Linear regression analysis showed higher correlation coefficent in predicting the true age at 90% of final height using chronological age + gender + central peak value (R. 2 . = 0.900) than chronological age + gender (R. 2.  = 0.879) and Greulich and Pyle bone age + gender (R. 2.  = 0.878). Conclusion. Chronological age + gender + central peak value provides more accurate prediction of 90% of final height compared with chronological age + gender and Greulich and Pyle bone age + gender. Cite this article: Bone Joint J 2018;100-B:1106–11


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature. Results. Quantitative MRI revealed a mean reduction of 21.2% (SD 1.3%) of arterial contribution in the lateral plating group and 25.4% (SD 3.2%) in the dual plating group (p = 0.051); representing a mean decrease in arterial contribution of 4.2%. The only significant difference found between both experimental groups was regionally, at the lateral aspect of the distal femur with a mean drop in arterial contribution in the lateral plating group of 18.9% (SD 2.6%) versus 24.0% (SD 3.2%) in the dual plating group (p = 0.048), representing a mean decrease in arterial contribution of 5.1%. Gross dissection revealed complete destruction of periosteal vessels underneath either medial or lateral plates in both groups. The network of genicular branches contributing to the posterior and distal femoral condyles was preserved in all specimens. A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyle and was undisrupted in the dual plating group. Conclusion. Lateral locking-plate application resulted in mean 21.2% reduction in distal femur vascularity. Addition of medial plates did not further markedly decrease vascularity. As such, the majority of the vascular insult occurred with lateral plating alone. Supplemental medially based fixation did not lead to marked devascularization of the distal femur, and should therefore be considered in the setting of comminution and poor bone stock in distal femoral fractures. Further clinical research is required to confirm the results of this study. Cite this article: Bone Joint J 2020;102-B(4):530–538


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 195 - 202
1 Feb 2024
Jamshidi K Kargar Shooroki K Ammar W Mirzaei A

Aims. The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach. Methods. A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and Sailhan’s functional criteria. Results. At final follow-up, the mean MSTS score was 29.1 (SD 0.9) in group A and 26.7 (SD 1.5) in group B (p = 0.006). According to Sailhan’s criteria, the knee function was good and fair in 14 (87.5%) and two (12.5%) patients of group A, and eight (57.1%) and six (42.9%) patients of group B, respectively (p = 0.062). The lesion had recurred in one patient (6.2%) in group A and four patients (28.6%) in group B. Limb shortening > 1 cm was recorded in one patient (6.2%) from group A and six patients (42.8%) from group B. Joint degeneration was noted in one patient from group A and three patients from group B. Conclusion. An intercondylar approach to a chondroblastoma of the middle two-quarters of the distal femoral epiphysis results in better outcomes than a medial or lateral epiphyseal approach: specifically, better limb function, a lower rate of recurrence, and a lower rate of physeal damage and joint degeneration. Cite this article: Bone Joint J 2024;106-B(2):195–202


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims. Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment. Patients and Methods. A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year. Results. There was a clinically relevant and significant difference in quality-of-life at six months in favour of fixation with an IMN (mean difference in EuroQol-5 Dimensions Score (EQ-5D) = 0.12; 95% CI 0.02 to 0.22; p = 0.025). There was weak evidence that this trend continued to one year (mean difference EQ-5D = 0.09; 95% CI -0.01 to 0.19; p = 0.073). There was a significant although very small reduction in angular deformity using an IMN (mean difference -1.02; 95% CI -1.99 to -0.06; p = 0.073). There was no evidence that there was a difference in any other outcomes at any time point. Take home message: IMN may be a superior treatment compared with anatomical locking plates for fractures of the distal femur. These findings are concordant with other data from pilot randomised studies which favour treatment of these fractures with an IMN. This study strongly supports the need for a definitive randomised trial. Cite this article: Bone Joint J 2016;98-B:846–50


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 357 - 363
1 Mar 2011
Gillespie RJ Levine A Fitzgerald SJ Kolaczko J DeMaio M Marcus RE Cooperman DR

Recently, gender-specific designs of total knee replacement have been developed to accommodate anatomical differences between males and females. We examined a group of male and female distal femora matched for age and height, to determine if there was a difference in the aspect ratio (mediolateral distance versus anteroposterior distance) and the height of the anterior flange between the genders. The Hamann-Todd Collection provided 1207 skeletally mature cadaver femora. The femoral length, the anteroposterior height, height of the lateral and medial flanges and the mediolateral width were measured in all the specimens. The mechanical axis of the femur, the cut articular width and the aspect ratio were assessed. Statistical analysis of the effect of gender upon the aspect ratio and the lateral and medial flanges was undertaken, controlling for age, height and race. The mean aspect ratio of male femora was 1.21 (. sd. 0.07) and of female femora it was 1.16 (. sd. 0.06) (p < 0.001). There was no significant difference between male and female specimens in the mean size of the lateral flange (6.57 mm (. sd. 2.57) and 7.02 mm (. sd. 2.36), respectively; p = 0.099) or of the medial flange (3.03 mm (. sd. 2.47) and 3.56 mm (. sd. 2.32), respectively; p = 0.67). Future work in the design of knee prostheses should take into account the overall variability of the anatomy of the distal femur


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 521 - 526
1 Apr 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 having a fixed-hinge design and 173 a rotating-hinge. The median age of the patients was 24 years (interquartile range 17 to 48). A total of 192 patients remained alive with a mean follow-up of 12 years (5 to 30). The risk of revision for any reason was 17% at five years, 33% at ten years and 58% at 20 years. Aseptic loosening was the main reason for revision of the fixed-hinge knees while infection and fracture of the stem were the most common for the rotating-hinge implant. The risk of revision for aseptic loosening was 35% at ten years with the fixed-hinge knee, which has, however, been replaced by the rotating-hinge knee with a hydroxyapatite collar. The overall risk of revision for any reason fell by 52% when the rotating-hinge implant was used. Improvements in the design of distal femoral endoprostheses have significantly decreased the need for revision operations, but infection remains a serious problem. We believe that a cemented, rotating-hinge prosthesis with a hydroxyapatite collar offers the best chance of long-term survival of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 865 - 869
1 Aug 2002
Wicart P Mascard E Missenard G Dubousset J

Failure of massive knee endoprostheses implanted for malignant tumours of the distal femur in children presents a difficult problem. We present the results of rotationplasty undertaken under these circumstances in four boys. They had been treated initially at a mean age of 9.5 years for a stage-IIB malignant tumour of the distal femur by resection and implantation of a massive knee endoprosthesis. After a mean period of eight years and a mean of four operative procedures, there was failure of the endoprosthesis because of aseptic loosening in two and infection in two. Function was poor with a mean Musculoskeletal Tumor Society score of 7.5/30, and considerable associated psychological problems. At a mean follow-up of 4.5 years after rotationplasty there was excellent function with a mean score of 27.5/30 and resolution of the psychological problems


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 223 - 226
1 Mar 2002
Terauchi M Shirakura K Katayama M Higuchi H Takagishi K Kimura M

We have analysed retrospectively the relationship between the axial parameters of alignment of the lower limb and the recurrence of varus deformity after high tibial osteotomy. We studied 29 patients (37 knees) with a mean age at surgery of 66 years. The mean follow-up was for 7.4 years (5 to 10.5). Recurrence of varus deformity was defined as an increase in the femorotibial angle of 3° or more, compared with that obtained six months after the operation. There were four patients (four knees) with recurrence of varus deformity. They had a greater varus inclination of the distal femur than those without varus recurrence. An association between varus inclination of the distal femur and horizontal obliquity of the joint surface was observed. Excessive obliquity prevents the shift of weight-bearing to the lateral compartment, and may cause a recurrence of varus deformity after high tibial osteotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1327 - 1330
1 Oct 2006
Tokuhara Y Kadoya Y Kanekasu K Kondo M Kobayashi A Takaoka K

The shape of the flexion gap in 20 normal knees was evaluated by axial radiography of the distal femur, and the results compared with those obtained in a previous study by MRI. The observed asymmetry was reduced by 29% using radiography, with a mean value of 3.6° (1.5° to 6.3°) compared with that obtained by MRI of 5.1° (2.6° to 9.5°), a mean discrepancy of 1.49°. The results obtained by radiography and MRI showed a strong correlation (r = 0.78). Axial radiography is acceptable for the evaluation of the flexion gap and is less expensive and more comfortable to perform than MRI. Additionally, no metallic artefact occurs when the radiological method is used for assessment after arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 683 - 690
1 May 2009
Victor J Van Doninck D Labey L Van Glabbeek F Parizel P Bellemans J

The understanding of rotational alignment of the distal femur is essential in total knee replacement to ensure that there is correct placement of the femoral component. Many reference axes have been described, but there is still disagreement about their value and mutual angular relationship. Our aim was to validate a geometrically-defined reference axis against which the surface-derived axes could be compared in the axial plane. A total of 12 cadaver specimens underwent CT after rigid fixation of optical tracking devices to the femur and the tibia. Three-dimensional reconstructions were made to determine the anatomical surface points and geometrical references. The spatial relationships between the femur and tibia in full extension and in 90° of flexion were examined by an optical infrared tracking system. After co-ordinate transformation of the described anatomical points and geometrical references, the projection of the relevant axes in the axial plane of the femur were mathematically achieved. Inter- and intra-observer variability in the three-dimensional CT reconstructions revealed angular errors ranging from 0.16° to 1.15° for all axes except for the trochlear axis which had an interobserver error of 2°. With the knees in full extension, the femoral transverse axis, connecting the centres of the best matching spheres of the femoral condyles, almost coincided with the tibial transverse axis (mean difference −0.8°, . sd. 2.05). At 90° of flexion, this femoral transverse axis was orthogonal to the tibial mechanical axis (mean difference −0.77°, . sd. 4.08). Of all the surface-derived axes, the surgical transepicondylar axis had the closest relationship to the femoral transverse axis after projection on to the axial plane of the femur (mean difference 0.21°, . sd. 1.77). The posterior condylar line was the most consistent axis (range −2.96° to −0.28°, . sd. 0.77) and the trochlear anteroposterior axis the least consistent axis (range −10.62° to +11.67°, . sd. 6.12). The orientation of both the posterior condylar line and the trochlear anteroposterior axis (p = 0.001) showed a trend towards internal rotation with valgus coronal alignment


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1275 - 1279
1 Sep 2013
Liu T Liu Z Zhang Q Zhang X

The aim of this study was to assess a specific protocol for the treatment of patients with a parosteal osteosarcoma of the distal femur with limb salvage involving hemicortical resection and reconstruction using recycled pasteurised autograft and internal fixation. Between January 2000 and January 2010, 13 patients with a mean age of 26.5 years (17 to 39) underwent this procedure. All the tumours were staged according to Enneking’s criteria: there were eight stage IA tumours and five stage IB tumours. The mean follow-up was 101.6 months (58 to 142), and mean post-operative Musculoskeletal Tumour Society functional score was 88.6% (80% to 100%) at the final follow-up. All the patients had achieved bony union; the mean time to union was 11.2 months (6 to 18). Local recurrence occurred in one patient 27 months post-operatively. No patient had a pulmonary metastasis. A hemicortical procedure for the treatment of a parosteal osteosarcoma is safe and effective. Precise pre-operative planning using MRI is essential in order to define the margins of resection. Although it is a technically demanding procedure, gratifying results make it worthwhile for selected patients. Cite this article: Bone Joint J 2013;95-B:1275–9


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 762 - 769
1 Sep 1991
Roberts P Chan D Grimer R Sneath R Scales J

Over a 16-year period, 135 custom-made distal femoral prostheses, based on a fully constrained Stanmore-type knee replacement, were used in the treatment of primary malignant or aggressive benign tumours. Survivorship analysis showed a cumulative success rate of 72% at five years and 64% at seven years. Intact prostheses in 91% of the surviving patients gave good or excellent functional results. Deep infection was the major complication, occurring in 6.8% of cases; clinical aseptic loosening occurred in 6.0%. Revision surgery was carried out for loosening and infection, and the early results are encouraging. We conclude that prosthetic replacement of the distal femur can meet the objectives of limb salvage surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 110 - 114
1 Jan 1996
Butt MS Krikler SJ Ali MS

We performed a prospective, randomised controlled trial of the operative versus non-operative treatment of 42 displaced fractures of the distal femur in elderly patients. Excellent or good results were achieved in 53% of the operated group and in 31% of the non-operated group. There were more complications in the latter, and the time to discharge was considerably longer


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 485 - 487
1 May 1999
Kerry RM Masri BA Beauchamp CP Duncan CP

We describe a U-shaped approach to the distal femur which, having divided the extensor mechanism and elevated the entire quadriceps muscle, gives excellent exposure and allows a number of reconstructive options. It was used in 14 patients, 13 of whom were followed up for a mean of 3.5 years (1 to 11). There was no case of flap necrosis, and complications related to the reconstruction were acceptable


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 583 - 587
1 Aug 1989
Jacobs M Loeb P Hungerford D

From 1974 to 1981, we performed 28 core decompressions of the distal femur for pathologically confirmed avascular necrosis. At a mean follow-up of 54 months (range 20 to 140 months) and using the Ficat stages, all seven cases in stage I and stage II had good results. Of 21 cases in stage III, 11 cases had good results, four had poor results, and six needed total knee replacement. There were no significant orthopaedic complications. The procedure is worthwhile and will be more accurate with new methods of imaging


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 232 - 237
1 Feb 2006
Saridis A Panagiotopoulos E Tyllianakis M Matzaroglou C Vandoros N Lambiris E

We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight. The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 938 - 942
1 Nov 1997
Cool WP Carter SR Grimer RJ Tillman RM Walker PS

We report our results in 24 children with malignant primary bone tumours of the distal femur treated with a Stanmore extendible endoprosthesis (SEER). This consists of a femoral component that can be lengthened, a constrained knee and an uncemented sliding tibial component which crosses the proximal tibial physeal plate perpendicularly. The average age of the patients at diagnosis was ten years and the mean follow-up was 4.7 years (2.5 to 7.9). The mean growth of the affected tibia was 76% (18 to 136) and of the fibula 83% (15 to 750) of the growth of the unaffected limb. Measurement of growth arrest lines showed that the mean growth of the proximal tibial physis on the affected side was 69% (43 to 100) of that of the normal side. The great variability in the growth of the physis cannot yet be explained


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1000 - 1007
1 Sep 2024
Gong T Lu M Sheng H Li Z Zhou Y Luo Y Min L Tu C

Aims. Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. Methods. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively. Results. Overall, 21 patients (16%) encountered complications, and the rate of aseptic loosening was 7% (9/134). The survival rate up to 8.5 years was 93% for aseptic loosening as the endpoint, and 88% for any reason as the endpoint, retrospectively. Conclusion. The use of an uncemented distal femoral endoprosthesis with a short, curved stem demonstrated a low incidence of aseptic loosening and achieved long-term survivorship of up to nine years. Meanwhile, aseptic loosening typically occurs in the early stage postoperatively. Cite this article: Bone Joint J 2024;106-B(9):1000–1007