We investigated a new intramedullary locking
nail that allows the distal interlocking screws to be locked to
the nail. We compared fixation using this new implant with fixation
using either a conventional nail or a locking plate in a laboratory
simulation of an osteoporotic fracture of the distal femur. A total
of 15 human cadaver femora were used to simulate an AO 33-A3 fracture
pattern. Paired specimens compared fixation using either a locking
or non-locking retrograde nail, and using either a locking retrograde
nail or a locking plate. The constructs underwent cyclical loading
to simulate single-leg stance up to 125 000 cycles. Axial and torsional
stiffness and displacement, cycles to failure and modes of failure
were recorded for each specimen. When compared with locking plate
constructs, locking nail constructs had significantly longer mean
fatigue life (75 800 cycles ( The new locking retrograde femoral nail showed better stiffness
and fatigue life than locking plates, and superior fatigue life
to non-locking nails, which may be advantageous in elderly patients. Cite this article:
We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter femoral head avoided over-lengthening of the limb or increased offset to improve soft-tissue tension as occurs sometimes in THA. In a subgroup of patients with significant pre-operative deformity, restoration of the normal hip anatomy with lower pre-operative femoral offset or significant shortening of the leg was still possible with SRA.
Aseptic loosening of the femoral component is
an important indication for revision surgery in unicompartmental knee
replacement (UKR). A new design of femoral component with an additional
peg was introduced for the cemented Oxford UKR to increase its stability.
The purpose of this study was to compare the primary stability of
the two designs of component. Medial Oxford UKR was performed in 12 pairs of human cadaver
knees. In each pair, one knee received the single peg and one received
the twin peg design. Three dimensional micromotion and subsidence
of the component in relation to the bone was measured under cyclical
loading at flexion of 40° and 70° using an optical measuring system.
Wilcoxon matched pairs signed-rank test was performed to detect
differences between the two groups. There was no significant difference in the relative micromotion
(p = 0.791 and 0.380, respectively) and subsidence (p = 0.301 and
0.176, respectively) of the component between the two groups at
both angles of flexion. Both designs of component offered good strength
of fixation in this cadaver study. Cite this article:
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.
A medical and engineering study was made of 1074 car accidents involving 2520 vehicle occupants. The injuries they sustained were correlated with details of the crash and with contact points inside the cars. Where possible the forces which were generated in the crash were estimated and related to the injuries. In all, 39 car occupants suffered femoral shaft fracture, with an incidence of 1.7% and 0.8% for front and rear seat occupants respectively. Of these, 31 had associated injuries to other regions of the body; these were the cause of 13 of the 14 deaths in this group. Associated injuries were more severe in car occupants who were not wearing seat belts but the incidence of femoral fracture was not significantly different. The mean velocity change (delta-V) causing femoral fracture was 26 mph (42 km/h) and there was a higher incidence of femoral shaft fracture when delta-V was over 30 mph. Estimates of forces needed to cause fracture were higher than those found in cadaver studies. The time to union of femoral fractures did not correlate with the severity of the crash but was longer (mean 19 weeks) than the average for other femoral fractures.
Our aim was to determine whether the length and function of the flexor carpi ulnaris muscle were affected by separating it from its soft tissue connections. We measured the length of flexor carpi ulnaris before and after its dissection in ten patients with cerebral palsy. After tenotomy, tetanic contraction shortened the muscle by a mean of 8 mm. Subsequent dissection to separate it from all soft tissue connections, resulted in a further mean shortening of 17 mm (p <
0.001). This indicated that the dissected connective tissue had been strong enough to maintain the length of the contracting muscle. Passive extension of the wrist still lengthened the muscle after tenotomy, whereas this excursion significantly decreased after subsequent dissection. We conclude that the connective tissue envelope, which may be dissected during tendon transfer of flexor carpi ulnaris may act as a myofascial pathway for the transmission of force. This may have clinical implications for the outcome after tendon transfer.
Repair of the rotator cuff requires secure reattachment, but large chronic defects cause osteoporosis of the greater tuberosity which may then have insufficient strength to allow proper fixation of the tendon. Recently, suture anchors have been introduced, but have not been fully evaluated. We have investigated the strength of suture-to-anchor attachment, and the use of suture anchors in repairs of the rotator cuff either to the greater tuberosity or the lateral cortex of the humerus. The second method gave a significant increase in the strength of the repair (p = 0.014). The repairs were loaded cyclically and failed at low loads by cutting into bone and tendon, casting doubt on the integrity of the repair in early mobilisation after surgery. Repairs with suture anchors did not perform better than those with conventional transosseous attachment.
Rockers are applied to lower limb casts to assist walking but there is little information on their biomechanical effects. The performances of 10 commercially available rockers were compared. They were applied to a below-knee cast worn by a normal subject who was also tested walking in the cast alone. Gait analysis was used to evaluate kinematic and kinetic data. The design of rocker had no effect upon the kinematics of walking. However, using new criteria for kinetic assessment of rocker function (tibial floor angular velocity and centre of pressure progression), most designs had a deleterious effect on the biomechanics of gait. Only two rockers approached the ideal kinetic criteria.
It has been shown by mechanical analysis that by using cement to bond the stem of a femoral head prosthesis to bone two advantages are obtained when the conditions are compared with conventional methods. 1. "Fretting" between the implant and the living bone is eliminated. This source of persistent relative movement is probably the most important starting point for the progressive loosening of weight-bearing implants. 2. When cement is used the bond with the bone is exposed to stresses which are of an order three hundred times less than the shear strength of bone. The conventional prostheses expose the bond to compressive stresses which are near to the failure limits of the compressive strength of bone, especially in elderly patients with atrophic cortical bone in the femoral neck.
We studied the healing and torsional strength of non-vascularised (28) and vascularised (28) sections of tibial diaphyses in 56 cats. Both types of graft achieved fracture union in the same period of time, and at 12 and 16 weeks the non-vascularised grafts were as strong as the vascularised grafts.
There have been conflicting reports on the effects of gamma irradiation on the material properties of cortical allograft bone. To investigate changes which result from the method of preparation, test samples must be produced with similar mechanical properties to minimise variations other than those resulting from treatment. We describe a new method for the comparative measurement of bone strength using standard bone samples. We used 233 samples from six cadavers to study the effects of irradiation at a standard dose (28 kGy) alone and combined with deep freezing. We also investigated the effects of varying the dose from 6.8 to 60 kGy (n = 132). None of the treatments had any effect on the elastic behaviour of the samples, but there was a reduction in strength to 64% of control values (p <
0.01) after irradiation with 28 kGy. There was also a dose-dependent reduction in strength and in the ability of the samples to absorb work before failure We suggest that irradiation may cause an alteration in the bone matrix of allograft bone, but provided it is used in situations in which loading is within its elastic region, then failure should not occur.
Sixty-five knees were subjected to a kinematic analysis using the instant-centre technique in order to determine the effect of deficiency of the anterior cruciate ligament on the biomechanics of active movement in the knee. The instant-centre pathway in acute ruptures of the anterior cruciate ligament was found to have a specific abnormality. This corresponded with a positive pivot-shift sign, but was present even when that sign was not clinically detectable. Primary repair using a transosseous wire suture did not usually abolish the biomechanical abnormality. The data provide a possible explanation for the doubtful prognosis of primary repair of this ligament and encourage clinical and biomechanical evaluation of alternative procedures such as primary augmented repair.
The anterior cruciate ligament (ACL) is frequently injured in elite athletes, with females up to eight times more likely to suffer an ACL tear than males.
Aims. In patients with a rotator cuff tear, tear pattern and tendon involvement are known risk factors for the development of pseudoparalysis of the shoulder. It remains unclear, however, why similar tears often have very different functional consequences. The present study hypothesizes that individual shoulder anatomy, specifically the moment arms (MAs) of the rotator cuff (RC) and the deltoid muscle, as well as their relative recruitment during shoulder abduction, plays a central role in pseudoparalysis. Materials and Methods.
Advances in polyethylene (PE) in total hip arthroplasty
have led to interest and increased use of highly crosslinked PE
(HXLPE) in total knee arthroplasty (TKA).
End caps are intended to prevent nail migration
(push-out) in elastic stable intramedullary nailing. The aim of
this study was to investigate the force at failure with and without
end caps, and whether different insertion angles of nails and end caps
would alter that force at failure. Simulated oblique fractures of the diaphysis were created in
15 artificial paediatric femurs. Titanium Elastic Nails with end
caps were inserted at angles of 45°, 55° and 65° in five specimens
for each angle to create three study groups.
There is a disparity in sport-related injuries between sexes, with females sustaining non-contact musculoskeletal injuries at a higher rate. Anterior cruciate ligament ruptures are between two and eight times more common than in males, and females also have a higher incidence of ankle sprains, patellofemoral pain, and bone stress injuries. The sequelae of such injuries can be devastating to an athlete, resulting in time out of sport, surgery, and the early onset of osteoarthritis. It is important to identify the causes of this disparity and introduce prevention programmes to reduce the incidence of these injuries. A natural difference reflects the effect of reproductive hormones in females, which have receptors in certain musculoskeletal tissues. Relaxin increases ligamentous laxity. Oestrogen decreases the synthesis of collagen and progesterone does the opposite. Insufficient diet and intensive training can lead to menstrual irregularities, which are common in female athletes and result in injury, whereas oral contraception may have a protective effect against certain injuries. It is important for coaches, physiotherapists, nutritionists, doctors, and athletes to be aware of these issues and to implement preventive measures. This annotation explores the relationship between the menstrual cycle and orthopaedic sports injuries in pre-menopausal females, and proposes recommendations to mitigate the risk of sustaining these injuries. Cite this article:
We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus.