The aim of this double-blind prospective randomised controlled
trial was to assess whether low intensity pulsed ultrasound (LIPUS)
accelerated or enhanced the rate of bone healing in adult patients
undergoing distraction osteogenesis. A total of 62 adult patients undergoing limb lengthening or bone
transport by distraction osteogenesis were randomised to treatment
with either an active (n = 32) or a placebo (n = 30) ultrasound
device. A standardised corticotomy was performed in the proximal
tibial metaphysis and a circular Ilizarov frame was used in all
patients. The rate of distraction was also standardised. The primary
outcome measure was the time to removal of the frame after adjusting
for the length of distraction in days/cm for both the per protocol
(PP) and the intention-to-treat (ITT) groups. The assessor was blinded
to the form of treatment. A secondary outcome was to identify covariates affecting
the time to removal of the frame.Aims
Patients and Methods
Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.