Advertisement for orthosearch.org.uk
Results 1 - 100 of 1294
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims. The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results. Methods. This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included. Results. All patients underwent more than two years of follow-up (mean 33.5 months (24 to 45)). All clinical scores were also improved at two-year follow-up (mean visual analogue scale 0.7 (SD 0.5) vs 6.1 (SD 1.2); p < 0.001; mean American Shoulder and Elbow Surgeons score 93.5 (SD 5.3) vs 42.5 (SD 10.8); p < 0.001; mean University of California, Los Angeles score, 31.7 (SD 3.7) vs 12.0 (SD 3.1); p < 0.001; and mean Constant-Murley score 88.7 (SD 3.5) vs 43.3 (SD 10.9); p < 0.001), and 24 of 26 fascia lata grafts were fully healed on MRI (92%). One patient had haematoma formation at the harvesting side of the fascia lata at two days postoperatively. Conclusion. The fascia lata autograft bridging repair combined with artificial ligament internal brace reinforcement technique achieved good functional outcomes, with a high rate of graft healing at two-year follow-up. Although the short-term results are promising, further studies with a greater number of patients would provide clearer results. Cite this article: Bone Joint J 2021;103-B(10):1619–1626


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1261 - 1267
1 Sep 2007
Tohyama H Yasuda K Uchida H Nishihira J

In order to clarify the role of cytokines in the remodelling of the grafted tendon for ligament reconstruction we compared the responses to interleukin (IL)-1β, platelet-derived growth factor (PDGF)-BB and transforming growth factor (TGF)-β1 of extrinsic fibroblasts infiltrating the frozen-thawed patellar tendon in rats with that of the normal tendon fibroblasts, in regard to the gene expression of matrix metalloproteinase (MMP)-13, using Northern blot analysis. We also examined, immunohistologically, the local expression of IL-1β, PDGF-BB, and TGF-β1 in fibroblasts infiltrating the frozen-thawed patellar tendon. Northern blot analysis showed that fibroblasts derived from the patellar tendon six weeks after the freeze-thaw procedure in situ showed less response to IL-1β than normal tendon fibroblasts with respect to MMP-13 mRNA gene expression. The immunohistological findings revealed that IL-1β was over-expressed in extrinsic fibroblasts which infiltrated the patellar tendon two and six weeks after the freeze-thaw procedure in situ, but neither PDGF-BB nor TGF-β1 was over-expressed in these extrinsic fibroblasts. Our findings indicated that IL-1β had a close relationship to matrix remodelling of the grafted tendon for ligament reconstruction, in addition to the commencement of inflammation during the tissue-healing process


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 230 - 234
1 Feb 2010
Anderson GA Thomas BP Pallapati SCR

Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p < 0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one. The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1244 - 1251
1 Dec 2023
Plastow R Raj RD Fontalis A Haddad FS

Injuries to the quadriceps muscle group are common in athletes performing high-speed running and kicking sports. The complex anatomy of the rectus femoris puts it at greatest risk of injury. There is variability in prognosis in the literature, with reinjury rates as high as 67% in the severe graded proximal tear. Studies have highlighted that athletes can reinjure after nonoperative management, and some benefit may be derived from surgical repair to restore function and return to sport (RTS). This injury is potentially career-threatening in the elite-level athlete, and we aim to highlight the key recent literature on interventions to restore strength and function to allow early RTS while reducing the risk of injury recurrence. This article reviews the optimal diagnostic strategies and classification of quadriceps injuries. We highlight the unique anatomy of each injury on MRI and the outcomes of both nonoperative and operative treatment, providing an evidence-based management framework for athletes.

Cite this article: Bone Joint J 2023;105-B(12):1244–1251.


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 377 - 386
1 May 1960
Whiston TB Walmsley R

1. A series of experiments on adult rabbits was carried out in which a tendon was transplanted and embedded in a bony tunnel and traversed a joint after the manner of a tenodesis. 2. Histological observations were made on the reaction of surrounding bone and tendon at intervals over a period of 307 days. 3. The findings suggest that the buried tendon undergoes a process of progressive degeneration, and that host cells issuing from the adjacent bone marrow infiltrate and ultimately replace it by new tendon tissue. 4. The invading cells are believed to be derived, as a result of the provocative stimuli provided by the experiment, from primitive reticular cells of the haemopoietic tissue. 5. The tunnelled bone undergoes considerable remodelling and associated with this is the presence of a considerable number of osteoblasts and osteoclasts


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 369 - 389
1 May 1973
Chaplin DM

1. The normal vascular anatomy of flexor tendons and extensor tendons in the hind limb of the rabbit is outlined. A marked difference between a tendon in a sheath and a tendon with a paratenon is shown, the latter having a much better blood supply. 2. The vascular reaction in flexor tendon divided within a sheath is shown. 3. The revascularisation of free grafts is illustrated and the differences between tendon with sheath and tendon with paratenon are detailed. 4. Experiments are reported to show that the microcirculation within a "vascular" tendon can support a pedicle graft in the rabbit. Such pedicle grafts are shown to be inferior to free grafts of "avascular" tendon, but the vascularity within the pedicle tendon graft may be modified by "blocking" the surface with silastic tubing. 5. The implications of this work on tendon grafting are discussed, together with a review of additional experimental work in related fields


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1284 - 1291
1 Jul 2021
Carter TH Karunaratne BJ Oliver WM Murray IR White TO Reid JT Duckworth AD

Aims. Acute distal biceps tendon repair reduces fatigue-related pain and minimizes loss of supination of the forearm and strength of flexion of the elbow. We report the short- and long-term outcome following repair using fixation with a cortical button techqniue. Methods. Between October 2010 and July 2018, 102 patients with a mean age of 43 years (19 to 67), including 101 males, underwent distal biceps tendon repair less than six weeks after the injury, using cortical button fixation. The primary short-term outcome measure was the rate of complications. The primary long-term outcome measure was the abbreviated Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes included the Oxford Elbow Score (OES), EuroQol five-dimension three-level score (EQ-5D-3L), satisfaction, and return to function. Results. Eight patients (7.8%) had a major complication and 34 (33.3%) had a minor complication. Major complications included re-rupture (n = 3; 2.9%), unrecovered nerve injury (n = 4; 3.9%), and surgery for heterotopic ossification (n = 1; 1.0%). Three patients (2.9%) overall required further surgery for a complication. Minor complications included neurapraxia (n = 27; 26.5%) and superficial infection (n = 7; 6.9%). A total of 33 nerve injuries occurred in 31 patients (30.4%). At a mean follow-up of five years (1 to 9.8) outcomes were available for 86 patients (84.3%). The median QuickDASH, OES, EQ-5D-3L, and satisfaction scores were 1.2 (IQR 0 to 5.1), 48 (IQR 46 to 48), 0.80 (IQR 0.72 to 1.0), and 100/100 (IQR 90 to 100), respectively. Most patients were able to return to work (81/83, 97.6%) and sport (51/62,82.3%). Unrecovered nerve injury was associated with an inferior outcome according to the QuickDASH (p = 0.005), OES (p = 0.004), EQ-5D-3L (p = 0.010), and satisfaction (p = 0.024). Multiple linear regression analysis identified an unrecovered nerve injury to be strongly associated with an inferior outcome according to the QuickDASH score (p < 0.001), along with infection (p < 0.001), although re-rupture (p = 0.440) and further surgery (p = 0.652) were not. Conclusion. Acute distal biceps tendon repair using cortical button fixation was found to result in excellent patient-reported outcomes and health-related quality of life. Although rare, unrecovered nerve injury adversely affects outcome. Cite this article: Bone Joint J 2021;103-B(7):1284–1291


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1194 - 1199
14 Sep 2020
Lee H Kim E Kim Y

Aims. The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a rotator cuff tear and to evaluate the factors related to the changes. Methods. A cohort of 162 patients who underwent isolated supraspinatus with the preservation of LHBT was enrolled and evaluated. The cross-sectional area (CSA) of the LHBT on MRI was measured in the bicipital groove, and preoperative to postoperative difference was calculated at least 12 months postoperatively. Second, postoperative changes in the LHBT including intratendinous signal change, rupture, dislocation, or superior labral lesions were evaluated with seeking of factors that were correlated with the changes or newly developed lesions after rotator cuff repair. Results. The postoperative CSA (12.5 mm. 2. (SD 8.3) was significantly larger than preoperative CSA (11.5 mm. 2. (SD 7.5); p = 0.005). In total, 32 patients (19.8%) showed morphological changes in the untreated LHBT 24 months after rotator cuff repair. Univariate regression analysis revealed that the factor chiefly related to the change in LHBT status was an eccentric LHBT position within the groove found on preoperative MRI (p = 0.011). Multivariate analysis using logistic regression also revealed that an eccentric LHBT position was a factor related to postoperative change in untreated LHBTs (p = 0.011). Conclusion. The CSA of the LHBT inside the biceps groove increased after rotator cuff repair. The preoperative presence of an eccentrically positioned LHBT was associated with further changes of the tendon itself after rotator cuff repair. Cite this article: Bone Joint J 2020;102-B(9):1194–1199


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1608 - 1617
1 Dec 2020
Castioni D Mercurio M Fanelli D Cosentino O Gasparini G Galasso O

Aims. The aim of this systematic review and meta-analysis is to evaluate differences in functional outcomes and complications between single- (SI) and double-incision (DI) techniques for the treatment of distal biceps tendon rupture. Methods. A comprehensive search on PubMed, MEDLINE, Scopus, and Cochrane Central databases was conducted to identify studies reporting comparative results of the SI versus the DI approach. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was used for search strategy. Of 606 titles, 13 studies met the inclusion criteria; methodological quality was assessed with the Newcastle-Ottawa scale. Random- and fixed-effects models were used to find differences in outcomes between the two surgical approaches. The range of motion (ROM) and the Disabilities of the Arm, Shoulder and Hand (DASH) scores, as well as neurological and non-neurological complications, were assessed. Results. A total of 2,622 patients were identified. No significant differences in DASH score were detected between the techniques. The SI approach showed significantly greater ROM in flexion (standardized mean difference (SMD) -0.508; 95% confidence interval (CI) -0.904 to -0.112) and pronation (SMD -0.325, 95% CI -0.637 to -0.012). The DI technique was associated with significantly less risk of lateral antebrachial cutaneous nerve damage (odds ratio (OR) 4.239, 95% CI 2.171 to 8.278), but no differences were found for other nerves evaluated. The SI group showed significantly fewer events of heterotopic ossification (OR 0.430, 95% CI 0.226 to 0.816) and a lower reoperation rate (OR 0.503, 95% CI 0.317 to 0.798). Conclusion. No significant differences in functional scores can be expected between the SI and DI approaches after distal biceps tendon repair. The SI approach showed greater flexion and pronation ROM and a lower risk of heterotopic ossification and reoperation. The DI approach was favourable in terms of lower risk of neurological complications. Cite this article: Bone Joint J 2020;102-B(12):1608–1617


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1312 - 1319
1 Oct 2016
Spang C Alfredson H Docking SI Masci L Andersson G

In recent years, the plantaris tendon has been implicated in the development of chronic painful mid-portion Achilles tendinopathy. In some cases, a thickened plantaris tendon is closely associated with the Achilles tendon, and surgical excision of the plantaris tendon has been reported to be curative in patients who have not derived benefit following conservative treatment and surgical interventions. The aim of this review is to outline the basic aspects of, and the recent research findings, related to the plantaris tendon, covering anatomical and clinical studies including those dealing with histology, imaging and treatment. Cite this article: Bone Joint J 2016;98-B:1312–19


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1535 - 1541
1 Nov 2020
Yassin M Myatt R Thomas W Gupta V Hoque T Mahadevan D

Aims. Functional rehabilitation has become an increasingly popular treatment for Achilles tendon rupture (ATR), providing comparably low re-rupture rates to surgery, while avoiding risks of surgical complications. Limited evidence exists on whether gap size should affect patient selection for this treatment option. The aim of this study was to assess if size of gap between ruptured tendon ends affects patient-reported outcome following ATR treated with functional rehabilitation. Methods. Analysis of prospectively collected data on all 131 patients diagnosed with ATR at Royal Berkshire Hospital, UK, from August 2016 to January 2019 and managed non-operatively was performed. Diagnosis was confirmed on all patients by dynamic ultrasound scanning and gap size measured with ankle in full plantarflexion. Functional rehabilitation using an established protocol was the preferred treatment. All non-operatively treated patients with completed Achilles Tendon Rupture Scores (ATRS) at a minimum of 12 months following injury were included. Results. In all, 82 patients with completed ATRS were included in the analysis. Their mean age was 51 years (standard deviation (SD) 14). The mean ATRS was 76 (SD 19) at a mean follow-up of 20 months (SD 11) following injury. Gap inversely affected ATRS with a Pearson’s correlation of -0.30 (p = 0.008). Mean ATRS was lower with gaps > 5 mm compared with ≤ 5 mm (73 (SD 21) vs 82 (SD 16); p = 0.031). Mean ATRS was lowest (70 (SD 23)) with gaps > 10 mm, with significant differences in perceived strength and pain. The overall re-rupture rate was two out of 131 (1.5%). Conclusion. Increasing gap size predicts lower patient-reported outcome, as measured by ATRS. Tendon gap > 5 mm may be a useful predictor in physically demanding individuals, and tendon gap > 10 mm for those with low physical demand. Further studies that control for gap size when comparing non-operative and operative treatment are required to assess if these patients may benefit from surgery, particularly when balanced against the surgical risks. Cite this article: Bone Joint J 2020;102-B(11):1535–1541


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 444 - 446
1 May 1994
Masterson E Jagannathan S Borton D Stephens M

Flat foot due to rupture of the tibialis posterior tendon has not previously been described in children. We present three young patients who developed unilateral pes planus after old undiagnosed lacerations of the tendon. Transfer of the flexor hallucis longus to the distal stump of the tibialis posterior tendon achieved good results in all three cases


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 309 - 317
1 Mar 2018
Kolk A Henseler JF Overes FJ Nagels J Nelissen RGHH

Aims. Since long-term outcome of teres major tendon transfer surgery for irreparable posterosuperior rotator cuff (RC) tears is largely unknown, the primary aim of this study was to evaluate the long-term outcome of the teres major transfer. We also aimed to report on the results of a cohort of patients with a similar indication for surgery that underwent a latissimus dorsi tendon transfer. Patients and Methods. In this prospective cohort study, we reported on the long-term results of 20 consecutive patients with a teres major tendon transfer for irreparable massive posterosuperior RC tears. Additionally, we reported on the results of the latissimus dorsi tendon transfer (n = 19). The mean age was 60 years (47 to 77). Outcomes included the Constant score (CS), and pain at rest and during movement using the Visual Analogue Scale (VAS). Results. At a mean of ten years (8 to 12) following teres major transfer, the CS was still 23 points (95% confidence interval (CI) 14.6 to 30.9, p < 0.001) higher than preoperatively. VAS for pain at rest (21 mm, 95% CI 4.0 to 38.9, p = 0.016) and movement (31 mm, 95% CI 16.0 to 45.1, p < 0.001) were lower than preoperatively. We also found an increase in CS (32 points, 95% CI 23.4 to 40.2, p < 0.001) and reduction of pain (26 mm, 95% CI 9.9 to 41.8, p = 0.001) six years after latissimus dorsi transfer. Conclusion. Teres major tendon transfer is a treatment option to gain shoulder function and reduce pain in patients with an irreparable posterosuperior RC tear at a mean follow-up of ten years. The teres major tendon might be a valuable alternative to the commonly performed latissimus dorsi tendon transfer in the treatment of irreparable posterosuperior RC tears. Cite this article: Bone Joint J 2018;100-B:309–17


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1361 - 1363
1 Oct 2005
Hardy JRW Chimutengwende-Gordon M Bakar I

We reviewed the records of 107 consecutive patients who had undergone surgery for disruption of the knee extensor mechanism to test whether an association existed between rupture of the quadriceps tendon and the presence of a patellar spur. The available standard pre-operative lateral radiographs were examined to see if a patellar spur was an indicator for rupture of the quadriceps tendon in this group of patients. Of the 107 patients, 12 underwent repair of a ruptured patellar tendon, 59 had an open reduction and internal fixation of a patellar fracture and 36 repair of a ruptured quadriceps tendon. In the 88 available lateral radiographs, patellar spurs were present significantly more commonly (p < 0.0005) in patients operated on for rupture of the quadriceps tendon (79%) than in patients with rupture of the patellar tendon (27%) or fracture of the patella (15%). In patients presenting with failure of the extensor mechanism of the knee in the presence of a patellar spur, rupture of the quadriceps tendon should be considered as a possible diagnosis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 557 - 564
1 Apr 2009
Rumian AP Draper ERC Wallace AL Goodship AE

An understanding of the remodelling of tendon is crucial for the development of scientific methods of treatment and rehabilitation. This study tested the hypothesis that tendon adapts structurally in response to changes in functional loading. A novel model allowed manipulation of the mechanical environment of the patellar tendon in the presence of normal joint movement via the application of an adjustable external fixator mechanism between the patella and the tibia in sheep, while avoiding exposure of the patellar tendon itself. Stress shielding caused a significant reduction in the structural and material properties of stiffness (79%), ultimate load (69%), energy absorbed (61%), elastic modulus (76%) and ultimate stress (72%) of the tendon compared with controls. Compared with the material properties the structural properties exhibited better recovery after re-stressing with stiffness 97%, ultimate load 92%, energy absorbed 96%, elastic modulus 79% and ultimate stress 80%. The cross-sectional area of the re-stressed tendons was significantly greater than that of stress-shielded tendons. The remodelling phenomena exhibited in this study are consistent with a putative feedback mechanism under strain control. This study provides a basis from which to explore the interactions of tendon remodelling and mechanical environment


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 583 - 587
1 Apr 2005
Szöke G Lee S Simpson AHRW Prescott J

Little is known about the increase in length of tendons in postnatal life or of their response to limb lengthening procedures. A study was carried out in ten young and nine adult rabbits in which the tibia was lengthened by 20% at two rates 0.8 mm/day and 1.6 mm/day. The tendon of the flexor digitorum longus (FDL) muscle showed a significant increase in length in response to lengthening of the tibia. The young rabbits exhibited a significantly higher increase in length in the FDL tendon compared with the adults. There was no difference in the amount of lengthening of the FDL tendon at the different rates. Of the increase in length which occurred, 77% was in the proximal half of the tendon. This investigation demonstrated that tendons have the ability to lengthen during limb distraction. This occurred to a greater extent in the young who showed a higher proliferative response, suggesting that there may be less need for formal tendon lengthening in young children


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon. Cite this article: Bone Joint J 2013;95-B:517–22


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 764 - 769
1 Jun 2013
Roche JJW Jones CDS Khan RJK Yates PJ

The piriformis muscle is an important landmark in the surgical anatomy of the hip, particularly the posterior approach for total hip replacement (THR). Standard orthopaedic teaching dictates that the tendon must be cut in to allow adequate access to the superior part of the acetabulum and the femoral medullary canal. However, in our experience a routine THR can be performed through a posterior approach without sacrificing this tendon. We dissected the proximal femora of 15 cadavers in order to clarify the morphological anatomy of the piriformis tendon. We confirmed that the tendon attaches on the crest of the greater trochanter, in a position superior to the trochanteric fossa, away from the entry point for broaching the intramedullary canal during THR. The tendon attachment site encompassed the summit and medial aspect of the greater trochanter as well as a variable attachment to the fibrous capsule of the hip joint. In addition we dissected seven cadavers resecting all posterior attachments except the piriformis muscle and tendon in order to study their relations to the hip joint, as the joint was flexed. At flexion of 90° the piriformis muscle lay directly posterior to the hip joint. The piriform fossa is a term used by orthopaedic surgeons to refer the trochanteric fossa and normally has no relation to the attachment site of the piriformis tendon. In hip flexion the piriformis lies directly behind the hip joint and might reasonably be considered to contribute to the stability of the joint. We conclude that the anatomy of the piriformis muscle is often inaccurately described in the current surgical literature and terms are used and interchanged inappropriately. Cite this article: Bone Joint J 2013;95-B:764–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1165 - 1170
1 Aug 2010
Hirpara KM Sullivan PJ O’Sullivan ME

We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiöld type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 889 - 893
1 Jun 2010
Kocaoglu B Agir I Nalbantoglu U Karahan M Türkmen M

We investigated the effect of mitomycin-C on the reduction of the formation of peritendinous fibrous adhesions after tendon repair. In 20 Wistar albino rats the tendo Achillis was cut and repaired using a modified Kessler technique. The rats were divided into two equal groups. In group 1, an injection of mitomycin-C was placed between the tendon and skin of the right leg. In group 2, an identical volume of sterile normal saline was injected on the left side in a similar fashion. All the rats received mitomycin-C or saline for four weeks starting from the day of operation. The animals were killed after 30 days. The formation of peritendinous fibrous tissue, the inflammatory reaction and tendon healing were evaluated. The tensile strength of the repaired tendons was measured biomechanically. Microscopic evidence of the formation of adhesions and inflammation was less in group 1. There was no significant difference in the tensile load required to rupture the repaired tendons in the two groups. Mitomycin-C may therefore provide a simple and inexpensive means of preventing of post-operative adhesions


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 668 - 670
1 May 2012
Gu YP Zhu SM

We describe a new surgical technique for the treatment of lacerations of the extensor tendon in zone I, which involves a tenodesis using a length of palmaris longus tendon one-quarter of its width. After exposing the dorsal aspect of the distal interphalangeal joint and harvesting the tendon, a 1.5 mm drill bit is passed through the insertion of the extensor tendon into the distal phalanx where it penetrates through the skin of the pulp of the digit. The palmaris longus tendon is threaded through the drill hole from dorsal to ventral and the ventral end is tied in a simple knot and trimmed. The palmaris longus tendon is then sutured to the extensor tendon close to its insertion, and also at the middle of the middle phalanx. The operation was undertaken on 67 patients: 27 with an acute injury and 40 patients with a chronic mallet deformity. One finger (or the thumb) was involved in each patient. At a mean follow-up of 12 months (6 to 18), 66 patients (98.5%) received excellent or good results according to both the American Society for Surgery of the Hand (ASSH) classification and Miller’s classification. Tenodesis using palmaris longus tendon after complete division of an extensor tendon in zone 1 is a reliable form of treatment for isolated acute or chronic ruptures


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 516 - 519
1 Apr 2008
Pichler W Tesch NP Schwantzer G Fronhöfer G Boldin C Hausleitner L Grechenig W

The purpose of this anatomical study was to explore the morphological variations of the semitendinosus and gracilis tendons in length and cross-section and the statistical relationship between length, cross-section, and body height. We studied the legs of 93 humans in 136 cadavers. In 43 specimens (46.2%) it was possible to harvest the tendons from both legs. We found considerable differences in the length and cross-section of the semitendinosus and the gracilis tendons with a significant correlation between the two. A correlation between the length of the femur, reflecting height, and the length of the tendons was only observed in specimens harvested from women. The reason for this gender difference was unclear. Additionally, there was a correlation between the cross-sectional area of the tendons and the length of the femur. Surgeons should be aware of the possibility of encountering insufficient length of tendon when undertaking reconstructive surgery as a result of anatomical variations between patients


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 103 - 106
1 Jan 2008
Kettler M Tingart MJ Lunger J Kuhn V

Operative fixation is the treatment of choice for a rupture of the distal tendon of biceps. A variety of techniques have been described including transosseous sutures and suture anchors. The poor quality of the bone of the radial tuberosity might affect the load to failure of the tendon repair in early rehabilitation. The aim of this study was to determine the loads to failure of different techniques of fixation and to investigate their association with the bone mineral density of the radial tuberosity. Peripheral quantitative computed tomography was carried out to measure the trabecular and cortical bone mineral density of the radial tuberosity in 40 cadaver specimens. The loads to failure in four different techniques of fixation were determined. The Endobutton-based method showed the highest failure load at 270 N (. sd. 22) (p < 0.05). The mean failure load of the transosseous suture technique was 210 N (. sd. 66) and that of the TwinFix-QuickT 5.0 mm was 57 N (. sd. 22), significantly lower than those of all other repairs (p < 0.05). No significant correlation was seen between bone mineral density and loads to failure. The transosseous technique is an easy and cost-saving procedure for fixation of the distal biceps tendon. TwinFix-QuickT 5.0 mm had significantly lower failure loads, which might affect early rehabilitation, particularly in older patients


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1171 - 1175
1 Aug 2010
Hajipour L Gulihar A Dias J

We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons in vitro and measured the coefficient of friction at the tendon-pulley interface with loads of 200 g and 400 g and in 10°, 30°, 50° and 70° of flexion. Laceration increased the coefficient of friction from 0.12 for the intact tendon to 0.3 at both the test loads. Trimming the laceration reduced the coefficient of friction to 0.2. An exponential increase in the gliding resistance was found at 50° and 70° of flexion (p = 0.02 and p = 0.003, respectively) following trimming compared to that of the intact tendon. We concluded that trimming partially lacerated flexor tendons will reduce the gliding resistance at the tendon-pulley interface, but will lead to fragmentation and triggering of the tendon at higher degrees of flexion and loading. We recommend that higher degrees of flexion be avoided during early post-operative rehabilitation following trimming of a flexor tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 633 - 638
1 May 2007
Matthews TJW Smith SR Peach CA Rees JL Urban JPG Carr AJ

We have undertaken an in vivo assessment of the tissue metabolism and cellular activity in torn tendons of the rotator cuff. Cellular oxygen consumption was measured in 13 patients undergoing mini-open repair of small, medium, large and massive full-thickness tears. Measurements were also taken from three control patients who were undergoing open stabilisation of the shoulder with grossly normal tendons. The level of oxygen and nitrous oxide was measured amperometrically using silver needle microelectrodes at the apex of the tear and 1.5 cm from its edge. With nitrous oxide indicating the degree of perfusion, oxygen consumption was calculated at each location to reflect cellular activity. All of the torn tendons had lower levels of cellular activity than the control group. This activity was lower still in the tissue nearest to the edge of the tear with the larger tears showing the lowest activity. This indicated reduced levels of tissue metabolism and infers a reduction in tendon viability. Our findings suggest that surgical repair of torn tendons of the rotator-cuff should include the more proximal, viable tissue, and may help to explain the high rate of re-rupture seen in larger tears


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001). Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 370 - 377
1 Mar 2011
Chaudhury S Dicko C Burgess M Vollrath F Carr AJ

We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the rotator cuff and to identify structural differences among anatomically distinct tears. Such information may help to identify biomarkers of tears and to provide insight into the rates of healing of different sizes of tear. The infrared spectra of 81 partial, small, medium, large and massive tears were measured using FTIR and compared with 11 uninjured control tendons. All the spectra were classified using standard techniques of multivariate analysis. FTIR readily differentiates between normal and torn tendons, and different sizes of tear. We identified the key discriminating molecules and spectra altered in torn tendons to be carbohydrates/phospholipids (1030 cm. −1. to 1200 cm. −1. ), collagen (1300 cm. −1. to 1700 cm. −1. and 3000 cm. −1. to 3350 cm. −1. ) and lipids (2800 cm. −1. to 3000 cm. −1. ). Our study has shown that FTIR spectroscopy can identify tears of the rotator cuff of varying size based upon distinguishable chemical and structural features. The onset of a tear is mainly associated with altered structural arrangements of collagen, with changes in lipids and carbohydrates. The approach described is rapid and has the potential to be used peri-operatively to determine the quality of the tendon and the extent of the disease, thus guiding surgical repair


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 388 - 392
1 Mar 2008
Virchenko O Aspenberg P Lindahl TL

Thrombin has many biological properties similar to those of growth factors. In a previous study, we showed that thrombin improves healing of the rat tendo Achillis. Low molecular weight heparin (LMWH) inhibits the activity and the generation of thrombin. We therefore considered that LMWH at a thromboprophylactic dose might inhibit tendon repair. Transection of the tendo Achillis was carried out in 86 rats and the healing tested mechanically. Low molecular weight heparin (dalateparin) was either injected a few minutes before the operation and then given continuously with an osmotic mini pump for seven days, or given as one injection before the operation. In another experiment ,we gave LMWH or a placebo by injection twice daily. The anti-factor Xa activity was analysed. Continuous treatment with LMWH impaired tendon healing. After seven days, this treatment caused a 33% reduction in force at failure, a 20% reduction in stiffness and a 67% reduction in energy uptake. However, if injected twice daily, LMWH had no effect on tendon healing. Anti-factor Xa activity was increased by LMWH treatment, but was normal between intermittent injections. Low molecular weight heparin delays tendon repair if given continuously, but not if injected intermittently, probably because the anti-factor Xa activity between injections returns to normal, allowing sufficient thrombin stimulation for repair. These findings indicate the need for caution in the assessment of long-acting thrombin and factor Xa inhibitors


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 141 - 144
1 Jan 2002
Petersen W Hohmann G Stein V Tillmann B

We studied the vascular pattern of human posterior tibial tendons by injection techniques and immunohistochemically using antibodies against laminin. The intravascular volume of the posterior tibial tendon was determined using a new method of injection of a solution of . 99m. Tc and gelatin ink into the lower legs of cadavers. Three segments of 1 cm length from different regions of the human posterior tibial tendon were measured using a gamma well counter. The main blood supply arises from the posterior tibial artery. Blood vessels enter the paratenon of the posterior tibial tendon via a mesotenon from the posterior aspect. From the paratenon, the blood vessels penetrate the posterior tibial tendon and anastomose with a longitudinally orientated intratendinous network. The number of vessels in the substance of the tendon is consistently less than that in the surrounding paratenon. The distribution of blood vessels within the posterior tibial tendon is not homogeneous. In the retromalleolar region the intravascular volume was significantly reduced with a mean value of 15 μl/g of tendon tissue. There was no significant difference between the mean intravascular volumes of the proximal and distal areas (distal, 27.7 μl/g tendon tissue; proximal, 30 μl/g tendon tissue). The immunohistochemical investigation showed that there was no immunostaining for laminin in the anterior part of the tendon in the region where it passes behind the medial malleolus. This region is avascular. The most frequent site of rupture of the posterior tibial tendon is in the region behind the medial malleolus. A potential endogenous risk factor may be the limited healing potential of avascular tissue


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 277 - 283
1 Feb 2010
Lampasi M Bettuzzi C Palmonari M Donzelli O

A total of 38 relapsed congenital clubfeet (16 stiff, 22 partially correctable) underwent revision of soft-tissue surgery, with or without a bony procedure, and transfer of the tendon of tibialis anterior at a mean age of 4.8 years (2.0 to 10.1). The tendon was transferred to the third cuneiform in five cases, to the base of the third metatarsal in ten and to the base of the fourth in 23. The patients were reviewed at a mean follow-up of 24.8 years (10.8 to 35.6). A total of 11 feet were regarded as failures (one a tendon failure, five with a subtalar fusion due to over-correction, and five with a triple arthrodesis due to under-correction or relapse). In the remaining feet the clinical outcome was excellent or good in 20 and fair or poor in seven. The mean Laaveg-Ponseti score was 81.6 of 100 points (52 to 92). Stiffness was mild in four feet and moderate or severe in 23. Comparison between the post-operative and follow-up radiographs showed statistically significant variations of the talo-first metatarsal angle towards abduction. Variations of the talocalcaneal angles and of the overlap ratio were not significant. Extensive surgery for relapsed clubfoot has a high rate of poor long-term results. The addition of transfer of the tendon of tibialis anterior can restore balance and may provide some improvement of forefoot adduction. However, it has a considerable complication rate, including failure of transfer, over-correction, and weakening of dorsiflexion. The procedure should be reserved for those limited cases in which muscle imbalance is a causative or contributing factor


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 3 | Pages 444 - 453
1 Aug 1961
Brand PW

1. Tendon grafts, in order to survive, have to develop a blood supply from their immediate environment. This causes adhesions. 2. Their final range of movement is therefore a sum of the length to which these vascular adhesions will stretch, and the range of movement of the normal tissues to which the tendon has become adherent. 3. Thus it is important that the tendon graft should lie in a bed of yielding material, and that no unyielding structures should be divided in the same wound. When possible, blunt tunnelling between short transverse incisions is the method of choice for placement of grafts. 4. The most crippling adhesions are those that grow from an imperfectly sutured cut end of tendon, leaving it unsatisfied. A new method of tendon anastomosis designed to prevent such adhesions is described. 5. A tendon grafting technique for intrinsic paralysis of the fingers in leprosy, using a radial extensor of the wrist as the motor and the plantaris tendon as the graft, is described. 6. A study of 861 fingers after the operation is presented. 7. The importance of re-education after operation is stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 489 - 495
1 Apr 2006
Matthews TJW Hand GC Rees JL Athanasou NA Carr AJ

We have studied cellular and vascular changes in different stages of full thickness tears of the rotator cuff. We examined biopsies from the supraspinatus tendon in 40 patients with chronic rotator cuff tears who were undergoing surgery and compared them with biopsies from four uninjured subscapularis tendons. Morphological and immunocytochemical methods using monoclonal antibodies directed against leucocytes, macrophages, mast cells, proliferative and vascular markers were used. Histological changes indicative of repair and inflammation were most evident in small sized rotator cuff tears with increased fibroblast cellularity and intimal hyperplasia, together with increased expression of leucocyte and vascular markers. These reparative and inflammatory changes diminished as the size of the rotator cuff tear increased. Marked oedema and degeneration was seen in large and massive tears, which more often showed chondroid metaplasia and amyloid deposition. There was no association between the age of the patient and the duration of symptoms. In contrast, large and massive tears showed no increase in the number of inflammatory cells and blood vessels. Small sized rotator cuff tears retained the greatest potential to heal, showing increased fibroblast cellularity, blood vessel proliferation and the presence of a significant inflammatory component. Tissue from large and massive tears is of such a degenerative nature that it may be a significant cause of re-rupture after surgical repair and could make healing improbable in this group


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 440 - 446
1 Apr 2002
Tohyama H Yasuda K

We performed a biomechanical and histological study to clarify the effect of stress enhancement on the in situ frozen-thawed patellar tendon of the rabbit as a tendon autograft model. We used 48 Japanese White rabbits divided into three groups. In group 1, the patellar tendon underwent in situ freeze-thaw treatment with liquid nitrogen to kill intrinsic fibroblasts. In group 2, after similar treatment, the medial and lateral portions were resected so that the cross-sectional area was reduced by a third. In group 3, after treatment, the cross-sectional area was reduced by a half. In groups 2 and 3, the stress in the tendon was calculated theoretically to be 150% and 200% of the physiological stress during locomotion. Eight rabbits in each group were killed at three and six weeks, respectively. At three weeks, the mean values for the tensile strength of groups 2 and 3 were 113.7% and 75.7% of that of group 1, and at six weeks 101.2% and 57.4%, respectively. The tensile strength in group 3 was significantly lower than that in groups 1 and 2. The histological findings in group 2 were similar to those in group 1, although an acellular area appeared to be wider in the core portion compared with group 1 at each period. In group 3, the collagen bundles of the tendon were less organised than those of groups 1 and 2. Our findings showed that stress enhancement affects the remodelling of the frozen-thawed patellar tendon and that excessively high stress reduces the mechanical properties of the tendon. This indicates that high stress on the patellar tendon autograft should be avoided during ligament reconstruction


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1533 - 1538
1 Nov 2006
Meyer DC Lajtai G von Rechenberg B Pfirrmann CWA Gerber C

We released the infraspinatus tendons of six sheep, allowed retraction of the musculotendinous unit over a period of 40 weeks and then performed a repair. We studied retraction of the musculotendinous unit 35 weeks later using CT, MRI and macroscopic dissection. The tendon was retracted by a mean of 4.7 cm (3.8 to 5.1) 40 weeks after release and remained at a mean of 4.2 cm (3.3 to 4.7) 35 weeks after the repair. Retraction of the muscle was only a mean of 2.7 cm (2.0 to 3.3) and 1.7 cm (1.1 to 2.2) respectively at these two points. Thus, the musculotendinous junction had shifted distally by a mean of 2.5 cm (2.0 to 2.8) relative to the tendon. Sheep muscle showed an ability to compensate for approximately 60% of the tendon retraction in a hitherto unknown fashion. Such retraction may not be a quantitatively reliable indicator of retraction of the muscle and may overestimate the need for elongation of the musculotendinous unit during repair


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1245 - 1251
1 Sep 2006
Pendegrass CJ Oddy MJ Sundar S Cannon SR Goodship AE Blunn GW

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure. Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 2 | Pages 234 - 243
1 May 1950
Crawford GNC

1. Small indian ink marks were made at intervals along the length of tendons in the limbs of young rabbits, and the distance between the marks was measured during the operation. The rabbits were killed two to three months later, and the amount of longitudinal growth that had occurred was determined by re-measuring the distance between the marks. 2. The experiments showed that the whole of the tendon grows interstitially in length, but that maximal growth occurs near the muscle-tendon junction. 3. Histological examination of the tendons and control experiments involving adult tendons indicated that growth was not significantly interfered with by marking the tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1689 - 1693
1 Dec 2005
Ikema Y Tohyama H Nakamura H Kanaya F Yasuda K

We compared the biological characteristics of extrinsic fibroblasts infiltrating the patellar tendon with those of normal, intrinsic fibroblasts in the normal tendon in vitro. Infiltrative fibroblasts were isolated from the patellar tendons of rabbits six weeks after an in situ freeze-thaw treatment which killed the intrinsic fibroblasts. These intrinsic cells were also isolated from the patellar tendons of rabbits which had not been so treated. Proliferation and invasive migration into the patellar tendon was significantly slower for infiltrative fibroblasts than for normal tendon fibroblasts. Flow-cytometric analysis indicated that expression of α5β1 integrin at the cell surface was significantly lower in infiltrative fibroblasts than in normal tendon fibroblasts. The findings suggest that cellular proliferation and invasive migration of fibroblasts into the patellar tendon after necrosis are inferior to those of the normal fibroblasts. The inferior intrinsic properties of infiltrative fibroblasts may contribute to a slow remodelling process in the grafted tendon after ligament reconstruction


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 801 - 802
1 Jun 2008
Lahoti O Bajaj S

Most cases of club foot (congenital talipes equinovarus) respond to non-operative treatment but resistant cases may need surgery. It is broadly accepted that lengthening of tendo Achillis, the tendon of tibialis posterior and capsulotomy of the ankle and subtalar joints are necessary during surgical release, but there is no consensus as to whether lengthening of the tendons of flexor hallucis longus and flexor digitorum longus is required. We randomised 13 children with severe bilateral club foot deformities to undergo lengthening of the flexor hallucis longus and flexor digitorum longus tendons on one side and simple decompression on the other. We found no difference in the deformities of the toes between the lengthened and non-lengthened sides at a mean follow-up of four years (2 to 6). We conclude that routine lengthening of the tendons of flexor hallucis longus and flexor digitorum longus during soft-tissue surgery for resistant club foot is not necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 86 - 90
1 Jan 1998
Hahn SB Lee JW Jeong JH

We reviewed 11 patients who had been treated between January 1986 and June 1994 for severe foot injuries by tendon transfer with microvascular free flaps. Their mean age was 5.6 years (3 to 8). Five had simultaneous tendon transfer and a microvascular free flap and six had separate operations. The mean interval between the tendon transfer and the microvascular free flap was 5.8 months (2 to 15) and the mean time between the initial injury and the tendon transfer was 9.6 months (2 to 21). The anterior tibial tendon was split in five of six cases. The posterior tibial tendon was used three times and the extensor digitorum longus tendon twice. The mean follow-up was 39.7 months (24 to 126). There were nine excellent and two good results. Postoperative complications included loosening of the transferred tendon (2), plantar flexion contracture (1) mild flat foot deformity (1) and hypertrophic scars (2). We recommend tendon transfer with a microvascular free flap in children with foot injuries combined with nerve injury and extensive loss of skin, soft tissue and tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 752 - 758
1 Jul 2004
Pötzl W Kümpers P Szuwart T Götze G Marquardt B Steinbeck J

Despite widespread use of radiofrequency (RF) shrinkage, there have been no animal studies on the effects of post-operative immobilisation on the histological properties of the shrunken tissue. We have therefore examined the role of post-operative immobilisation after RF shrinkage with special emphasis on the histological properties of collagenous tissue. One patellar tendon of 66 New Zealand White rabbits was shrunk. Six rabbits were killed immediately after the operation. Twenty rabbits were not immobilised, 20 were immobilised for three weeks and 20 for six weeks. Fibroblasts, collagen and vascular quality and density were evaluated on sections, stained by haematoxylin and eosin. Nine weeks after operation the histological properties were inferior to those of the contralateral control tendons. Shrunk tendons did not return to normal at any time after operation irrespective of whether the animals had been immobilised or not. All the parameters improved significantly between zero and three weeks after operation. Immobilised tendons tended to have a better and faster recovery. Careful rehabilitation is imperative after RF shrinkage. Immobilisation aids recovery of the histological properties. Our findings in this animal model support a period of immobilisation of more than three weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 720 - 725
1 Jul 1998
Sano H Uhthoff HK Backman DS Brunet JA Trudel G Pham B Ishii H

We examined macroscopically and microscopically 55 cadaver rotator-cuff tendons attached to their humeral heads to determine the distance between the edge of the articular cartilage and the tendon insertion of the supraspinatus (the width of the sulcus) and the score of regressive changes at the sulcus. In 33 specimens we measured the tensile strength. The width of the sulcus was correlated with the score of regressive changes and with the ultimate tensile strength of the supraspinatus tendon. The width of the sulcus correlated positively with the score of regressive changes (r = 0.66, p < 0.0001), but there was a negative correlation between the latter and the ultimate tensile strength (r = −0.81, p = 0.001) and between the width of the sulcus and the ultimate tensile strength (r = −0.74, p = 0.004). We believe that the width of the sulcus is a simple and useful clinical indicator of the integrity and the tensile strength of the supraspinatus tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 348 - 351
1 Mar 2005
Kreuz PC Remiger A Lahm A Herget G Gächter A

We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 441 - 443
1 May 1984
Hooper G Davies R Tothill P

Blood flow in intact tendons in dogs was measured using 57Co-labelled microspheres and compared with the simultaneous clearance of a diffusible radionuclide, 85Sr, by the same tendons. Clearance was significantly greater than flow in all tendons, indicating that diffusion from surrounding tissues may be important in the nutrition of normal tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 1 | Pages 175 - 194
1 Feb 1956
Pulvertaft RG

1. A series of 149 consecutive cases of flexor tendon grafting in the fingers and thumb is reviewed and the results are analysed. A description of the technique which has evolved from this experience is given. 2. Replacement of a divided flexor digitorum profundus in the presence of an intact sublimis tendon restored a useful range of movement in 80 per cent of cases. 3. Replacement of both flexor digitorum profundus and sublimis gave good results in 70 to 80 per cent of cases. 4. Replacement of a divided flexor pollicis longus tendon gave good results in 85 per cent of cases. 5. The particular tendon used for the graft did not materially influence the result, but there are special indications for the use of the different tendons. 6. The choice of splintage or of early movement after operation does not appear to have a significant bearing upon the result. 7. The most important factor in determining the result is probably a precise and gentle surgical technique and complete haemostasis. Minor differences in method are of little importance. The failures in this series were due more to faulty performance of the operation than to any other single factor


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001). It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 3 | Pages 466 - 469
1 Aug 1952
Cave AJE Brown RW

1. The descriptive anatomy of the tendinous component of the subclavius muscle is amplified. 2. The subclavius tendon comprises a shorter, medial pars libera, continuous with a longer, narrower, more lateral pars paramuscularis. This last may be prolonged further laterally by two or three tendinous fasciculi. 3. Both parts of the subclavius tendon are constant. By tenodesis they provide, on the average, one and a half to two inches of material eminently suitable for employment in the functional replacement of a damaged costo-clavicular ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 881 - 883
1 Nov 1995
Taylor G Clarke N

We report 22 patients (19 women and three men) of mean age 20.8 years who had painful snapping sensations in the groin. Most were able to reproduce the click by extending the affected hip from a flexed, abducted and externally rotated position and most were tender in the adductor triangle. Plain radiographs and an arthrogram were normal. A clinical diagnosis of subluxation of the iliopsoas tendon was made. Conservative management failed in 14 patients, two of whom had bilateral pain. All 14 had surgical release of the iliopsoas tendon through a medial approach. At follow-up (mean 17 months) the click had resolved in ten hips, was occasional but painless in five and unchanged in one. The syndrome of a painful 'snapping' psoas may result in disproportionately disabling symptoms. It may be diagnosed on clinical grounds and effectively treated, when severe, by release of the iliopsoas tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 151 - 153
1 Jan 1992
Brooks C Revell W Heatley F

Previous perfusion studies of the rotator cuff have demonstrated an area of hypovascularity in the distal part of the supraspinatus tendon. This has been implicated in the pathogenesis of its rupture. We performed a quantitative histological analysis of the vascularity of the tendons of supraspinatus and infraspinatus. Vessel number, size and the percentage of the tendon occupied by vessels were measured at 5 mm intervals from the humeral insertions to the muscle bellies. Both tendons were hypovascular in their distal 15 mm. No significant difference was demonstrated between the vascularity of supraspinatus and infraspinatus. We conclude that factors other than vascularity are important in the pathogenesis of supraspinatus rupture


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 883 - 886
1 Aug 2003
Manoj Kumar RV Rajasekaran S

Ochronosis, the musculoskeletal manifestation of alkaptonuria, is known to lead to degenerative changes of the spine and weight-bearing joints. Symptoms related to degeneration of tendons or ligaments with spontaneous ruptures have not previously been reported. Three patients are described with four spontaneous ruptures of either the patellar tendon or tendo Achillis as the first symptom of alkaptonuria


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 2 | Pages 320 - 322
1 May 1974
Said GZ

1. A modified technique of tendon transference for irreparable damage of the radial nerve is described. The tendon of the pronator teres is transferred to the two radial extensors of the wrist and to the tendon of extensor carpi ulnaris. 2. The method succeeds in preventing radial deviation on attempted dorsiflexion of wrist and helps to provide a powerful grip


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 585 - 587
1 Aug 1985
Das De S Balasubramaniam P

A lesion similar to that described by Bankart in recurrent dislocation of the shoulder was seen in seven patients with recurrent dislocation of the peroneal tendons. Detachment of the periosteum had resulted in the formation of a false pouch on the surface of the lower end of the fibula; into this pouch the peroneal tendons could easily dislocate. Reattachment of the periosteum to drill holes in the fibula prevented dislocation, and this anatomical method of repair is described. This lesion is one of the causes of recurrent dislocation of the peroneal tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 359 - 363
1 May 1968
Fitton JM Shea FW Goldie W

1. Pain at the front of the radial side of the wrist may be caused by various lesions of the tendon and sheath of the flexor carpi radialis tendon. 2. The diagnosis may be established by testing resisted movement at the wrist and by the effect of injecting local anaesthetic into the tendon sheath. 3. In women over the age of fifty the lesion is associated with osteoarthritis of the joint between the scaphoid and the trapezium. 4. Osteoarthritis of the joint between the scaphoid and the trapezium is found in about 25 per cent of women over the age of fifty. 5. If the pain is not relieved by simple conservative measures it can usually be cured by incision of the tendon sheath. 6. The histological changes in the tendon sheath are similar to those found in tenovaginitis of the abductor pollicis longus and tibialis posterior tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1610 - 1612
1 Dec 2006
Al-Rashid M Theivendran K Craigen MAC

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1257 - 1262
1 Sep 2009
Sundar S Pendegrass CJ Oddy MJ Blunn GW

We used demineralised bone matrix (DBM) to augment re-attachment of tendon to a metal prosthesis in an in vivo ovine model of reconstruction of the extensor mechanism at the knee. We hypothesised that augmentation of the tendon-implant interface with DBM would enhance the functional and histological outcomes as compared with previously reported control reconstructions without DBM. Function was assessed at six and 12 weeks postoperatively, and histological examination was undertaken at 12 weeks. A significant increase of 23.5% was observed in functional weight-bearing at six weeks in the DBM-augmented group compared with non-augmented controls (p = 0.004). By 12 weeks augmentation with DBM resulted in regeneration of a more direct-type enthesis, with regions of fibrocartilage, mineralised fibrocartilage and bone. In the controls the interface was predominantly indirect, with the tendon attached to the bone graft-hydroxyapatite base plate by perforating collagen fibres


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 242 - 244
1 Mar 1995
Nakhostine M Perko M Cross M

We report four patients with a mean age of 17 years (14 to 22) with external rotation injuries of the knee in slight flexion. Radiographs showed a small fragment in the area of the lateral femoral condyle. At operation, the fragment, consisting of the femoral insertion of the popliteus, was anatomically reduced and fixed. At a mean follow-up of 35 months all the knees had an excellent function score. An isolated lesion of the popliteus often presents as a tendon avulsion whereas major damage to the posterolateral corner of the knee involves combined ligamentous injuries. In patients with an acute haemarthrosis and lateral pain in a stable knee, the diagnosis of isolated avulsion of the popliteus tendon should be suspected. Arthroscopy with special attention to the lateral gutter is indicated. We advise anatomical reduction and fixation of the fragment to prevent possible long-term effects on other posterolateral structures


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 767 - 770
1 Sep 1996
Le Huec JC Moinard M Liquois F Zipoli B Chauveaux D Le Rebeller A

We report ten cases of rupture of the distal part of the tendon of biceps brachii in patients aged from 27 to 58 years. MRI allowed assessment of the degree of retraction of the tendon which was related to the integrity of the bicipital expansion. When the retraction exceeded 8 cm the expansion was always ruptured. When there was doubt, or in longstanding injury, MRI allowed the lesions to be defined. Surgical repair was by reinsertion on the radial tuberosity at one or two fixation points in eight patients and reinsertion on the anterior brachial muscle in one. The other patient refused surgery. The MRI findings were confirmed at operation. Use of fixation points allowed minimal intervention, thereby reducing the risk of damaging the radial nerve. One year after operation, dynamometric evaluation of the strength of flexion and supination confirmed that the best results were obtained by reinsertion to the radial tuberosity


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 790 - 795
1 Sep 1999
Weale AE Murray DW Newman JH Ackroyd CE

Patella infera may occur after reconstruction of the anterior cruciate ligament (ACL), high tibial osteotomy and total knee replacement (TKR). Restriction of movement of the knee and pain may result. Our aim was to compare the incidence and to assess the effects of patella infera after TKR and unicompartmental knee replacement (UKR). We reviewed radiographs of the knees of 84 patients who had had either TKR or UKR as part of a randomised, controlled trial. The length of the patellar tendon was measured on serial radiographs taken before, at eight months and at five years after operation. There was no significant change in the length of the patellar tendon after UKR, but a significant reduction was observed after TKR. Five years after the operation, the shortening of the tendon had increased to a mean of 3.5 mm. Of the knees with TKR reviewed at five years, 34% developed patella infera, defined as 10% or more of shortening, compared with 5% of those with UKR. Shortening was greatest in those knees which had required a lateral release; in this subgroup the mean shortening was 7.2 mm. Shortening correlated with restriction of movement and pain in the knee. Our study has shown that patella infera develops in most patients after TKR with lateral release, and in approximately 25% of patients after TKR without this additional procedure. Patella infera rarely occurs after UKR. It is associated with restriction of movement and pain in the knee. It may be an effect of the more extensive exposure required to perform TKR and may, in part, explain the better clinical results of UKR


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1072 - 1076
1 Sep 2000
Uhthoff HK Sano H Trudel G Ishii H

In 14 rabbits we determined the origin of the cells effecting healing of the tendon of supraspinatus inserted into a bony trough. After two weeks both the cellularity of the underlying bone and the thickness of the subacromial bursa were significantly increased in the operated compared with the control shoulders. The cellularity of the stump of the tendon, however, was significantly decreased in the operated shoulders. In this model, both the underlying bone and the subacromial bursa but not the stump of the tendon contributed to the process of repair. We conclude that the medial stump should be debrided judiciously but that cutting back to bleeding tissue is not necessary during repair of the rotator cuff. Moreover, great care should be taken to preserve the subacromial bursa since it seems to play an important role in the healing process


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 523 - 526
1 Nov 1978
Norris S Mankin H

Chronic non-specific tenosynovitis of the posterior tibial tendon is a well-known clinical entity, characterised by pain, swelling and tenderness behind the medial malleolus. There are no reports in the literature of any case associated with any radiological abnormality. Three such cases are discussed, each presenting with the clinical findings typical of the syndrome but with associated radiological changes. These changes may pose diagnostic problems and several primary conditions need to be excluded. Surgical decompression of the tendon may be necessary to relieve symptoms, to prevent erosion and rupture of the tendon, and to establish the diagnosis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 487 - 493
1 Apr 2009
Dayer R Assal M

We studied a cohort of 26 diabetic patients with chronic ulceration under the first metatarsal head treated by a modified Jones extensor hallucis longus and a flexor hallucis longus transfer. If the first metatarsal was still plantar flexed following these two transfers, a peroneus longus to the peroneus brevis tendon transfer was also performed. Finally, if ankle dorsiflexion was < 5° with the knee extended, a Strayer-type gastrocnemius recession was performed. The mean duration of chronic ulceration despite a minimum of six months’ conservative care was 16.2 months (6 to 31). A total of 23 of the 26 patients were available for follow-up at a mean of 39.6 months (12 to 61) after surgery. All except one achieved complete ulcer healing at a mean of 4.4 weeks (2 to 8) after surgery, and there was no recurrence of ulceration under the first metatarsal. We believe that tendon balancing using modified Jones extensor hallucis longus and flexor hallucis longus transfers, associated in selected cases with a peroneus longus to brevis transfer and/or Strayer procedure, can promote rapid and sustained healing of chronic diabetic ulcers under the first metatarsal head


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 34 - 36
1 Jan 1999
Matsumoto H Kawakubo M Otani T Fujikawa K

Two men, aged 21 and 50 years, were seen with ossification of the patellar tendon after injury to the knee in adolescence. They complained of pain and had patella alta. Large bony masses were excised from below the affected patellae. The patellar tendon was then reconstructed using a Leeds-Keio ligament. The results at six and ten years, respectively, were good, with neither patient having pain or an extension lag


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1054 - 1058
1 Sep 2000
Khan U Kakar S Akali A Bentley G McGrouther DA

The formation of restrictive adhesions around the musculotendinous unit after injury is one of the most vexing processes faced by the surgeon. In flexor tendons it has been shown that the synovial tissue is the source of aggressive fibroblasts which contribute to this process. Using a rabbit model, we have examined the effects of treating the synovial sheath with the antimetabolite 5-fluorouracil (5-FU) for five minutes. Inflammatory, proliferative and molecular markers were compared in the response of the treated and control tendons to injury. Compared with a control group we found that the proliferative and inflammatory responses were significantly reduced (p < 0.001) in the treated tendons. Not only was there a reduction in the cellular and cytokine response, but there also was a significant (p < 0.001) reduction in the level of activity of the known pro-scarring agent, transforming growth factor beta 1 (TGF-β1). These pilot studies indicate that the formation of restrictive adhesions may be modulated using a simple single-touch technique in the hope of producing a better return of function


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 98 - 100
1 Jan 1984
Poll R Duijfjes F

Ten cases of post-traumatic recurrent dislocation of the peroneal tendons were operated on between 1974 and 1982. In all cases the disturbed superior peroneal retinaculum was reconstructed by transposition of the calcaneofibular ligament to the lateral side of the peroneal tendons. The calcaneal insertion of the calcaneofibular ligament was mobilised with a small bone block and reinserted in its bed after the transposition. After an average follow-up of four years all the results were satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 1 | Pages 64 - 68
1 Feb 1979
Abernethy P Dennyson W

Simple decompression of the extensor tendons at the wrist was carried out on fifty-four wrists in a total of forty-one patients with rheumatoid disease. This procedure was combined with excision of the ulnar head in forty-five wrists. Complete resolution of the synovitis occurred in 81.5 per cent of the wrists. In two patients the tendons ruptured soon after operation and in both cases this was due to prolapse of the ulnar stump after an associated Darrach procedure. The clinical results of decompression compare favourably with those of the widely accepted operation of dorsal tenosynovectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 230 - 236
1 May 1976
Matthews P Richards H

The effects of splintage, suture and excision of the tendon sheath on the healing of incompletely transected flexor tendons in the rabbit have been evaluated separately and in various combinations. When all procedures were done together, repair was accompanied by dense adhesion formation with little evidence of any healing activity by the tendon cells. The experiments indicated that the adhesions were the result not of any one single factor studied but of all three contributing in varying degrees. Suturing produced the most adhesions but synovial sheath excision and immobilisation also contributed. It is suggested that these factors are also responsible for the adhesions which occur after flexor tendon repair in clinical practice


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 198 - 199
1 Mar 1994
Dandy D Desai S

We studied changes in patellar tendon length after reconstruction of the anterior cruciate ligament using either the medial third of the patellar tendon as a graft (n = 40) or a Leeds-Keio artificial ligament (n = 40). Both types of ligament replacement had been supplemented with a MacIntosh extra-articular lateral substitution. The mean change in length in the tendon graft group was 6% (SD 5.39); in the Leeds-Keio group it was 2.4% (SD 4.93). The change in length was significant in both groups, but shortening was more frequent and more severe in the tendon graft group. There was shortening of 10% or more in 25% of knees after patellar tendon graft and 7.5% after use of a Leeds-Keio prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 471 - 472
1 Nov 1980
Dooley B Kudelka P Menelaus M

Subcutaneous rupture of the tendon of tibialis anterior immediately proximal to its insertion affects patients over the age of 45 years and is most common in the seventh decade. The symptoms at the time of rupture are milder than is the case with rupture of the calcaneal tendon and the early disability is slight. Thus, affected patients commonly present several weeks or months after rupture and at a stage when reattachment of the tendon to its normal site of insertion (the most satisfactory surgical management) is impossible. Although the disability is slight if repair is not performed, there should be no disability after surgical repair and this should be offered to those patients who lead an active life and who present in the first three months after rupture. The relevant literature is reviewed and experience with four further patients is recounted


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 204 - 205
1 Mar 2001
Thomas RH Holt MD James SH White PG

The imaging techniques available to aid the diagnosis of ruptures of tendo Achillis, the rotator cuff and the tendon of tibialis posterior in rheumatoid patients are well described. However, ruptures of tendon or muscle at other sites are uncommon and may be overlooked. Diagnosis is often made by localised tenderness, swelling and a lack of active movement associated with a palpable defect. Clinical examination may be inconclusive and can be aided by imaging studies. We report two cases in which ruptures of a tendon were suspected, and ultrasound imaging demonstrated the palpable defect to be a cleavage plane in the subcutaneous fat – a ‘fat fracture’


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 823 - 826
1 Sep 1996
Liu SH Hang DW Gentili A Finerman GAM

We performed MRI on 16 patients who had had reconstruction of the anterior cruciate ligament (ACL) with a mid-third bone-patellar-tendon-bone autograft. Our aim was to assess the tendon and the site of its insertion at an average of seven years after the original operation. In four of these patients biopsies were taken from the donor site when they had revision of their original operation. MRI showed reconstitution of the tendon into the patellar defect with no evidence of bone formation. Six patients had a persistent defect in the patellar tendon itself. Histological examination of the biopsies of the donor site showed an indirect pattern of insertion with absence of the normal fibrocartilage zone. These morphological changes may adversely affect the biomechanical properties of the healed donor site and we suggest that another graft taken from this site may not be suitable for use in a further operation for reconstruction of the ACL


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 398 - 400
1 Mar 2007
In Y Kim S Kwon Y

Patella infera can cause knee pain and lead to patellofemoral osteoarthritis. Treatment is usually unsatisfactory. We describe a case of severe patella infera after operative treatment for fracture of the patella. We used Ilizarov external fixation and gradual lengthening of the patellar tendon. The patellar height was restored and the patient’s symptoms were much improved


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 53 - 57
1 Feb 1977
Jenkins D Forster I McKibbin B Ralis Z

Experiments have been performed on rabbits and sheep which demonstrate that pure carbon, in a flexible and filamentous form of great strength, can be used successfully to induce the formation of new tendons. A concept fundamentally different from that underlying the use of other artificial tendon replacements is involved, in which rapidly developing tendon-like tissue is induced to form around the implant. This gradually takes over the function of the implant. The early results in rabbits and the late results in sheep suggest that filamentous carbon may have a place in the replacement of the calcaneal tendon and the collateral ligaments of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 301 - 307
1 Mar 2004
Özgenel GY

We have investigated the effects of the intra-operative application of a combination of hyaluronic acid and amniotic membrane on adhesions in the flexor tendons of a chicken model. We used 144 tendons which were partially divided and then repaired by a modified Kessler technique. There were four test groups: group 1, simple tendon repair, group 2, repair site wrapped with amniotic membrane, group 3, hyaluronic acid injected around the repair site, and group 4, repair site wrapped with amniotic membrane and hyaluronic acid injected within it. At three and six weeks, the extent of the adhesions and the healing of the tendon were evaluated macroscopically and histologically. The range of movement of the toe and tensile strength of the repaired tendons were measured at 20 weeks. The least adhesions were observed in group 4 but no significant difference was found in the healing of the tendons. Overall, the intra-operative application of a combination of hyaluronic acid and amniotic membrane appears to be effective in preventing adhesions of the flexor tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 316 - 319
1 May 1983
Purnell M Drummond D Engber W Breed A

Congenital dislocation of the peroneal tendons is a rare and infrequently reported deformity of the foot in the neonate. Four cases of this deformity associated with a congenital calcaneovalgus deformity of the foot have been treated and followed to the resolution of both of the deformities. The calcaneovalgus foot proved more resistant to correction and required more prolonged and aggressive treatment than was usual when it was found as an isolated deformity. All four patients demonstrated other stigmata of intra-uterine malposition and oligohydramnios or both. Our anatomical studies suggested that the superior peroneal retinacular ligament was the critical stabilising structure for the peroneal tendons. A concept of the pathogenesis of this deformity is discussed and a proven regimen for its treatment presented


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1177 - 1180
1 Nov 2000
Fitoussi F Mazda K Frajman J Jehanno P Penneçot GF

This is a retrospective study of primary repairs of flexor pollicis longus in 16 children under 15 years of age. Patients with injuries to the median or ulnar nerve at the wrist, crush injuries, skin loss or fracture were excluded. Repairs were carried out within 24 hours using a modified Kessler technique. The mean follow-up was for two years. The final results were evaluated using the criteria of Buck-Gramko and Tubiana. They were good or excellent in all except one patient who had a secondary tendon rupture. When compared with the non-injured thumb, however, there was a significant decrease in active interphalangeal flexion (> 30°) in one-third of cases. A new method of assessment is proposed for the recovery of function of the flexor pollicis tendon which is more suitable for children. Postoperative immobilisation using a short splint had a negative effect on outcome. The zone of injury, an early mobilisation programme or concurrent injury to the digital nerve had no significant effect on the final result


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1000 - 1003
1 Sep 2002
Gibbons CLMH Khwaja HA Cole AS Cooke PH Athanasou NA

Giant-cell tumour of the tendon sheath (GCT-TS) is a benign solitary tumour which usually arises in the limbs. It occurs most often in the hand where local recurrence after excision has been reported in up to 45% of cases. It is less common in the foot where the biological behaviour and risk of local recurrence have not been defined. We have studied 17 cases of GCT-TS of the foot and ankle in which treatment was by excision. Fifteen presented as a solitary, painless, slow-growing soft-tissue swelling. One lesion was associated with sensory deficit of a digital nerve and one with pain on walking. Thirteen cases originated from the periarticular tendon-sheath complex of the small joints of the toes and four from the capsule or long tendons of the ankle. A correct preoperative diagnosis was made in only three cases. MRI proved to be the most useful preoperative investigation as GCT-TS has a characteristic appearance which allows planned local excision to be carried out. None of the patients with histologically confirmed GCT-TS required further surgery. There was no local recurrence in 15 patients who were available for follow-up at a mean of 85 months


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 272 - 274
1 Mar 1989
Jozsa L Balint J Kannus P Reffy A Barzo M

We aimed to determine the distribution of the ABO and Rh blood groups in 832 patients with a tendon rupture. Among these, the frequency of blood group O (52.8%) was significantly higher than in the general population of Hungary (31.1%) and the frequency of group A was significantly lower. Of the 83 cases of multiple ruptures or re-rupture, 57 patients (68.7%) had group O blood. The dominance of group O was found for all sites of tendon rupture, but there was no significant association with the Rh groups. Individuals with blood group O appear to have an increased risk of tendon rupture


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 610 - 613
1 May 2008
Armstrong AL Dias JJ

We describe a new method of stabilising a painful unstable sternoclavicular joint using the sternocleidomastoid tendon and passing it through the medial clavicle and onto the manubrium sternum. This method is simple, reproducible and avoids the potential risks of reefing the joint to the first rib. The technique was used in seven cases of sternoclavicular joint instability in six patients who were reviewed at a mean of 39.7 months (15 to 63). Instability was markedly reduced or eliminated in all cases, but in one there was occasional persistant subluxation. There were minor scar complications after two procedures and one patient had transient ulnar neuritis. This procedure provides satisfactory results in the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 389 - 394
1 May 1991
Gerber C Krushell R

Traumatic rupture of the tendon of the subscapularis muscle was documented as an isolated lesion in the shoulders of 16 men. The injury was caused either by forceful hyperextension or external rotation of the adducted arm. The patients complained of anterior shoulder pain and weakness of the arm when it was used above and below the shoulder level. They did not experience shoulder instability. The injured shoulders exhibited increased external rotation and decreased strength of internal rotation. A simple clinical manoeuvre called the 'lift-off test', reliably diagnosed or excluded clinically relevant rupture of the subscapularis tendon. Confirmation of the clinical diagnosis was best achieved by ultrasonography or MRI, but arthrography or CT arthrography were also useful. Surgical exploration confirmed the diagnosis in every case. Repair of the ruptured tendon was technically demanding and required good exposure to identify and protect the axillary nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 882 - 888
1 Jul 2012
van der Heijden L Gibbons CLMH Dijkstra PDS Kroep JR van Rijswijk CSP Nout RA Bradley KM Athanasou NA Hogendoorn PCW van de Sande MAJ

Giant cell tumours (GCT) of the synovium and tendon sheath can be classified into two forms: localised (giant cell tumour of the tendon sheath, or nodular tenosynovitis) and diffuse (diffuse-type giant cell tumour or pigmented villonodular synovitis). The former principally affects the small joints. It presents as a solitary slow-growing tumour with a characteristic appearance on MRI and is treated by surgical excision. There is a significant risk of multiple recurrences with aggressive diffuse disease. A multidisciplinary approach with dedicated MRI, histological assessment and planned surgery with either adjuvant radiotherapy or systemic targeted therapy is required to improve outcomes in recurrent and refractory diffuse-type GCT. Although arthroscopic synovectomy through several portals has been advocated as an alternative to arthrotomy, there is a significant risk of inadequate excision and recurrence, particularly in the posterior compartment of the knee. For local disease partial arthroscopic synovectomy may be sufficient, at the risk of recurrence. For both local and diffuse intra-articular disease open surgery is advised for recurrent disease. Marginal excision with focal disease will suffice, not dissimilar to the treatment of GCT of tendon sheath. For recurrent and extra-articular soft-tissue disease adjuvant therapy, including intra-articular radioactive colloid or moderate-dose external beam radiotherapy, should be considered


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001). In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options. Cite this article: Bone Joint J 2013;95-B:523–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 777 - 780
1 Jun 2010
Contreras MEK Dani WS Endges WK De Araujo LCT Berral FJ

We undertook a prospective pilot study to determine whether arthroscopic surgery through the central compartment of the hip was effective in the management of a snapping iliopsoas tendon. Seven patients were assessed pre-operatively and at three, six, 12 and 24 months after operation. This included the assessment of pain on a visual analogue scale (VAS) and function using the modified Harris hip score. All the patients had resolution of snapping post-operatively and this persisted at follow-up at two years. The mean VAS score for pain fell from 7.7 (6 to 10) pre-operatively to 4.3 (0 to 10) by three months (p = 0.051), and to 3.6 (1 to 8) (p = 0.015), 2.4 (0 to 8) (p = 0.011) and 2.4 (0 to 8) (p = 0.011) by six, 12 and 24 months, respectively. The mean modified Harris hip score increased from 56.1 (13.2 to 84.7) pre-operatively to 88.4 (57.2 to 100) at one year (p = 0.018) and to 87.9 (49.5 to 100) at two years (p = 0.02). There were no complications and no weakness occurred in the musculature around the hip. Our findings suggest that this treatment is effective and would support the undertaking of a larger study comparing this procedure with other methods of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 208 - 213
1 May 1980
Porat S Rousso M Shoshan S

The long flexor tendons of the second, third and fourth toes of 94 chickens were cut and sutured. After operation the birds were divided into three groups. To reduce peritendinous adhesions, an aqueous solution of beta-aminopropionitrile (BAPN) was added to a solution of enriched native collagen (ECS) and applied to the cut tendons of one group; untreated controls and controls treated with collagen solution alone comprised the other groups. Chickens from each group were killed one, two, three, four and five weeks after operation. The results were evaluated both biomechanically and biochemically. It was found that the collagen solution alone had the same effect as the treatment with BAPN. It is suggested that the exogenous collagen present at the site of injury binds the collagenase inhibitor released by tendon cells, thus providing enough active collagenase to control the formation of fibrous adhesions. The inefficiency of BAPN in these experiments might have been due to either inadequate dosage or wrong timing, or both


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 591 - 595
1 Aug 1988
Chow J Thomes L Dovelle S Monsivais J Milnor W Jackson J

We present a system for treatment by controlled motion after repair of flexor tendons in the hand. This Washington regimen incorporates both controlled active extension against passive flexion by rubber band and the use of controlled passive extension and flexion. We utilise the Brooke Army Hospital modification of the rubber band passive flexion splint; this provides for maximal excursion of the tendon with full passive flexion of the finger. The 66 patients (78 fingers) who form the basis of this study all sustained complete laceration of the flexor profundus and superficialis tendons in "no man's land". Results were evaluated by the Strickland formula of total active motion (TAM) of the proximal and distal interphalangeal joints. Sixty-two fingers (80%) were rated "excellent", 14 fingers (18%) were "good", two fingers (2%) were "fair", none was rated "poor". Our regimen of controlled motion rehabilitation has also been applied with equal success to cases of flexor tendon grafting


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 630 - 637
1 May 2012
Bourke HE Gordon DJ Salmon LJ Waller A Linklater J Pinczewski LA

The purpose of this study was to report the outcome of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with ‘isolated’ ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time. ACL reconstructive surgery in patients with an ‘isolated’ rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 246 - 253
1 Feb 2020
Alluri RK Lightdale-Miric N Meisel E Kim G Kaplan J Bougioukli S Stevanovic M

Aims

To describe and analyze the mid-term functional outcomes of a large series of patients who underwent the Hoffer procedure for brachial plexus birth palsy (BPBP).

Methods

All patients who underwent the Hoffer procedure with minimum two-year follow-up were retrospectively reviewed. Active shoulder range of movement (ROM), aggregate modified Mallet classification scores, Hospital for Sick Children Active Movement Scale (AMS) scores, and/or Toronto Test Scores were used to assess functional outcomes. Subgroup analysis based on age and level of injury was performed. Risk factors for subsequent humeral derotational osteotomy and other complications were also assessed. A total of 107 patients, average age 3.9 years (1.6 to 13) and 59% female, were included in the study with mean 68 months (24 to 194) follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 4 | Pages 686 - 689
1 Nov 1965
Griffiths JC

1. An account is given of twenty patients who had sustained accidental division of one or more foot tendons (other than tendo calcaneus). 2. Severe deformities occur when these injuries are neglected in children


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 571 - 573
1 May 2000
Kotwal PP Gupta V Malhotra R

Giant-cell tumour of the tendon sheath, also called pigmented villonodular synovitis, is a benign tumour with a high incidence of recurrence. We have tried to identify risk factors for recurrence. Of the 48 patients included in the study, 14 received radiotherapy after surgery. Only two (4%) had a recurrence. This compares favourably with previously reported incidences of between 25% and 45%


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 583 - 587
1 Aug 1988
Amis A Jones M

We examined the structure of the digital flexor sheath by dissection and histology. The inner aspect of the sheath was found not to be a continuous smooth surface, as depicted in anatomical and surgical texts. The thin parts of the sheath often overlapped the pulleys before attaching to their superficial aspects, so that the pulleys possessed free edges within the sheath. The frequency of occurrence and sizes of these overlaps were studied in 48 cadaveric fingers; the largest and most frequent overlap was at the distal end of the A2 pulley. Functional studies showed an intricate mechanism of pulley approximation and sheath bulging during flexion. Sutured or partly cut tendons triggered on the free edges; this could be a major contributor to the failures of tendon repairs in "no man's land"


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1262 - 1266
1 Sep 2010
Carda S Molteni F Bertoni M Zerbinati P Invernizzi M Cisari C

This study assessed if transfer of the extensor hallucis longus is a valid alternative treatment to split transfer of the tibialis anterior tendon in adult hemiplegic patients without overactivity of the tibialis anterior. One group of 15 patients had overactivity of tibialis anterior in the swing phase, and underwent the split transfer. A further group of 14 patients had no overactivity of tibialis anterior, and underwent transfer of extensor hallucis longus. All patients had lengthening of the tendo Achillis and tenotomies of the toe flexors. All were evaluated clinically and by three-dimensional gait analysis pre- and at one year after surgery. At this time both groups showed significant reduction of disability in walking. Gait speed, stride length and paretic propulsion had improved significantly in both groups. Dorsiflexion in the swing phase, the step length of the healthy limb and the step width improved in both groups, but only reached statistical significance in the patients with transfer of the extensor hallucis longus. There were no differences between the groups at one year after operation. When combined with lengthening of the tendo Achillis, transfer of the extensor hallucis longus can be a valid alternative to split transfer of the tibialis anterior tendon to correct equinovarus foot deformity in patients without overactivity of tibialis anterior


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 881 - 883
1 Sep 1990
Magnussen P Harvey F Tonkin M

We reviewed 21 patients with 22 ruptures of the extensor pollicis longus at a mean of 5.3 years after transfer of the extensor indicis proprius tendon. Of these, 19 with 21 transfers described the result as good, and two as fair. The mean deficit of extension between the operated and unoperated thumbs was 1.4 cm, and the mean flexion deficit 0.6 cm. Pressure gauge measurements showed that the strength of the transfer was 51% of that of the uninjured extensor. The two fair results had an extensor lag of over 1.5 cm. Independent extension of the index was maintained in all patients, none having a discernible lag, but the strength of index extension was reduced to 49% of that of the normal finger. There was no evidence of functional loss. Extensor indicis proprius transfer for rupture of the extensor pollicis longus tendon is a simple and reliable procedure with few complications. It gives satisfactory long-term extension of the thumb


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 225 - 226
1 Mar 1998
Bell JSP Wollstein R Citron ND

We report three complete ruptures and one partial rupture of the flexor pollicis longus tendon in association with the insertion of a volar plate for the treatment of fracture of the distal radius. Rupture was associated with the chronic use of steroids


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 3 | Pages 446 - 447
1 Aug 1955
Holden NT

1. Two cases of deposition of calcium on the outer side of the knee are described. 2. The condition is believed to be uncommon and does not appear to have been described before. 3. One case resolved with conservative treatment, the other after an operation at which the deposit was found in the tendon of popliteus


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 781 - 784
1 Sep 1998
Borton DC Lucas P Jomha NM Cross MJ Slater K

Rupture of the tendons of both peroneus longus and peroneus brevis results in considerable disability. We have performed transfer of flexor digitorum longus (FDL) to peroneus brevis in two patients with lateral instability of the hindfoot due to chronic transverse tears of both tendons for which end-to-end repair was not possible. Both patients had excellent function when reviewed after eight and six years, respectively, with no symptoms. CT showed a normal appearance of the FDL in both patients, but the peroneal muscles looked abnormal. Transfer of the FDL provides a reliable solution to lateral instability of the hindfoot resulting from loss of function of both peronei


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 206 - 212
1 May 1977
Eskeland G Eskeland T Hovig T Teigland J

Three normal digital flexor tendon sheaths and the corresponding tissue formed around five silicone rod tendon implants, two silicone rubber mammary prostheses and one polyethylene tubing implant have been examined by light microscopy and by transmission and scanning electron microscopy. No principal difference in morphology was found. The surface facing tendon or implant was almost invariably covered with an irregular layer of amorphous material and filaments; only occasionally were collagen fibrils or cells exposed. Beneath the surface there were abundant collagen fibrils and some cells; besides fibroblasts, cells rich in filaments and often with numerous glycogen granules, mitochondria and peripherally located vesicles were found. These cells were frequently surrounded by a thick layer of an amorphous matrix. The results indicate that the implants caused remarkably little tissue reaction


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 150 - 151
1 Feb 1968
Nava BE

1. A case of traumatic forward dislocation of the tibialis posterior tendon at the ankle is described. 2. A possible mechanism of the injury is suggested


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 128 - 130
1 Jan 1984
Addison A

A case of Dupuytren's contracture is described, in which, both clinically and histologically, knuckle pad lesions involved the extensor tendons. Surgical excision of the Dupuytren's tissue from the dorsal aspect of the proximal interphalangeal joints, freeing of the lateral extensor slips and posterior capsulotomy resulted in marked functional improvement


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 325 - 327
1 Mar 1998
Hui JHP De SD Balasubramaniam P

Recurrent dislocation of peroneal tendons is uncommon and there are few reports of the long-term results after repair. The Singapore operation, first described in 1985, is an anatomical repair based on the Bankart-like lesion seen in the superior peroneal retinaculum. We reviewed 21 patients after a mean follow-up of 9.3 years, and found no recurrence. Eighteen had good functional results and had returned to their previous levels of vocational and sports activities. The three fair results were due to painful scars or neuromas


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 834 - 837
1 Aug 2001
Natsu-ume T Shino K Nakata K Nakamura N Toritsuka Y Mae T

A total of 30 patients who underwent endoscopic reconstruction of the anterior cruciate ligament using quadrupled hamstring tendons, through a single drill hole in the femur, had MRI 24 to 28 months after operation. In 18 patients the scans revealed that both the anterior and posterior portions of the graft ran in parallel from the inside of the femoral to the tibial tunnel. In 12, the posterior bundle had moved anteriorly and the anterior bundle could not be identified at the anterodistal border of the femoral tunnel. The mean difference in the anterior laxity, when compared with the contralateral knee, was 2.0 ± 1.7 mm and 4.3 ± 2.8 mm for the two types, respectively. Damage to the anterior bundle may occur when using the endoscopic technique because of biomechanical disadvantages, including concentration of loading and repetitive bending stress in the anterior bundle at the opening of the femoral tunnel


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 424 - 425
1 Apr 2000
Ramesh R Britton JM

Over-zealous release of the first dorsal compartment of the wrist for de Quervain’s disease or other lesions such as ganglia, may result in volar subluxation of the tendons of abductor pollicis longus and extensor pollicis brevis. This is usually asymptomatic, but may occasionally become disabling. We describe an operation using part of the extensor retinaculum to stabilise such a subluxation