Advertisement for orthosearch.org.uk
Results 1 - 100 of 358
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. Methods. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75). Results. DM bearings were used significantly more frequently in elderly patients (p = 0.003) and in hips with abductor deficiency (p < 0.001). The re-dislocation rate was 13.2% for DM bearings compared with 17.9% for standard bearings, and 22.2% for constrained liners (p = 0.432). Re-revision-free survival for DM bearings was 84% (95% confidence interval (CI) 0.77 to 0.91) compared with 74% (95% CI 0.67 to 0.81) for standard articulations, and 67% (95% CI 0.51 to 0.82) for constrained liners (p = 0.361). Younger age (hazard ratio (HR) 0.92 (95% CI 0.85 to 0.99); p = 0.031), lower comorbidity (HR 0.44 (95% CI 0.20 to 0.95); p = 0.037), smaller heads (HR 0.80 (95% CI 0.64 to 0.99); p = 0.046), and retention of the acetabular component (HR 8.26 (95% CI 1.37 to 49.96); p = 0.022) were significantly associated with re-dislocation. All DM bearings which re-dislocated were in patients with abductor muscle deficiency (HR 48.34 (95% CI 0.03 to 7,737.98); p = 0.303). The radiological analysis did not reveal a significant relationship between restoration of the geometry of the hip and re-dislocation. The mean mHHSs significantly improved from 43 points (0 to 88) to 67 points (20 to 91; p < 0.001) at the final follow-up, with no differences between the types of bearing. Conclusion. We found that the use of DM bearings reduced the rates of re-dislocation and re-revision in revision THA for recurrent dislocation, but did not guarantee stability. Abductor deficiency is an important predictor of persistent instability. Cite this article: Bone Joint J 2024;106-B(5 Supple B):89–97


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 4 | Pages 721 - 727
1 Nov 1960
Carter C Sweetnam R

An inquiry was made of ninety-seven patients with recurrent dislocation of the patella and forty patients with recurrent dislocation of the shoulder to see how often they had a relative similarly affected, and also how often such dislocation is associated with, and perhaps caused by, familial joint laxity. Ten of those with recurrent dislocation of the patella and two of those with recurrent dislocation of the shoulder were found to have a near relative with a similar dislocation. Familial joint laxity was found in two of the ten families with more than one member affected by recurrent patellar dislocation, and in both those with more than one member with recurrent dislocation of the shoulder. Familial joint laxity was also found in two out of twenty patients with recurrent dislocation of the patella who had no family history of similar dislocation; but in none out of twenty patients with recurrent dislocation of the shoulder and who had no family history of similar dislocation. Familial joint laxity may be the only cause of recurrent dislocation of the shoulder occurring in more than one member of the family. But there are other, as yet undefined, causes of familial recurrent dislocation of the patella


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1046 - 1049
1 Aug 2015
Abdel MP Cross MB Yasen AT Haddad FS

The aims of this study were to determine the functional impact and financial burden of isolated and recurrent dislocation after total hip arthroplasty (THA). Our secondary goal was to determine whether there was a difference between patients who were treated non-operatively and those who were treated operatively. . We retrospectively reviewed 71 patients who had suffered dislocation of a primary THA. Their mean age was 67 years (41 to 92) and the mean follow-up was 3.8 years (2.1 to 8.2). . Because patients with recurrent dislocation were three times more likely to undergo operative treatment (p < 0.0001), they ultimately had a significantly higher mean Harris Hip Score (HHS) (p = 0.0001), lower mean Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores (p = 0.001) and a higher mean SF-12 score (p < 0.0001) than patients with a single dislocation. Likewise, those who underwent operative treatment had a higher mean HHS (p < 0.0001), lower mean WOMAC score (p < 0.0001) and a higher mean SF-12 score (p < 0.0001) than those who were treated non-operatively. Recurrent dislocation and operative treatment increased costs by 300% (£11 456; p < 0.0001) and 40% (£5217; p < 0.0001), respectively. The operative treatment of recurrent dislocation results in significantly better function than non-operative management. Moreover, the increase in costs for operative treatment is modest compared with that of non-operative measures. Cite this article: Bone Joint J 2015; 97-B:1046–9


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 340 - 346
1 May 1966
Osborne G Cotterill P

1. Recurrent dislocation of the elbow is caused primarily by collateral ligament laxity with secondary damage to the capitulum and head of radius. 2. The pathological changes resemble those of recurrent dislocation of the shoulder. 3. Subluxation or instability of the radial head is often associated with capsular ossification and deserves wider recognition because it may be confused with osteochondritis dissecans. 4. A simple method of soft-tissue repair has successfully prevented redislocation of eight elbows


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 39 - 46
1 Feb 1948
Eyre-Brook AL

1. The operative findings in seventeen cases of recurrent dislocation of the shoulder are presented and discussed. Detachment of the glenoid labrum (thirteen cases) and the formation of a posterior humeral groove (eleven cases) were the most consistent findings. 2. In one case recurrent dislocation of the shoulder was due to avulsion of the subscapularis muscle. 3. The surgical treatment of these cases is described, usually consisting of a modification of Bankart's operation. 4. The results of follow-up are given as an intermediate report. No post-operative dislocation has so far been reported


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 585 - 587
1 Aug 1985
Das De S Balasubramaniam P

A lesion similar to that described by Bankart in recurrent dislocation of the shoulder was seen in seven patients with recurrent dislocation of the peroneal tendons. Detachment of the periosteum had resulted in the formation of a false pouch on the surface of the lower end of the fibula; into this pouch the peroneal tendons could easily dislocate. Reattachment of the periosteum to drill holes in the fibula prevented dislocation, and this anatomical method of repair is described. This lesion is one of the causes of recurrent dislocation of the peroneal tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 26 - 38
1 Feb 1948
Adams JC

A review of the pathology, mechanism, and operative treatment of recurrent dislocation of the shoulder, based on an analysis of 180 cases, with 159 operations, is presented. From this analysis the following conclusions have been made and appear to be substantiated:. 1. The pathology comprises two important elements: (a) anterior detachment of the glenoid labrum from the bone margin of the glenoid, associated with some degree of stripping of the anterior part of the capsule from the front of the neck of the scapula, found in 87 per cent. of cases examined adequately at operation; (b) defect or flattening of the posterolateral aspect of the articular surface of the head of the humerus which engages with the glenoid cavity when the arm is in external rotation and abduction; this defect is demonstrated most readily in antero-posterior radiographs taken with the humerus in 60 to 70 degrees of internal rotation and was shown to be present in 82 per cent. of cases which had been subjected to adequate radiographic examination. 2. The frequency of the humeral head defect has been under-estimated in the past, because of the difficulty of demonstrating it, particularly when the defect is small. 3. Either type of lesion alone may predispose to recurrence of the dislocation. 4. Both types of lesion are often present in the same shoulder. When this is the case the tendency to redislocation is great. 5. The initial dislocation, which results in the development of one or both these persistent structural abnormalities, may be due to very different types of injury, the commonest of which is a fall on the outstretched hand. The factor common to all these injuries is a resultant force acting on the humeral head in the direction of the anterior glenoid margin. 6. In the treatment of recurrent dislocation of the shoulder joint the Nicola operation is unreliable, and it may be associated with a recurrence rate as high as 36 per cent. It is believed that continued instability after this operation is usually due to the presence of a defect of the humeral head. 7. Operative treatment should aim at repairing, or nullifying, the effects of both types of lesion. For anterior detachment of the labrum this involves either suturing the labrum back to the glenoid margin, or constructing some form of anterior buttress, fibrous or bony: for humeral head defects it necessitates some procedure designed to limit external rotation, thus preventing the defect from coming into engagement with the glenoid cavity. Such limitation of external rotation does not constitute a significant disability


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 4 | Pages 841 - 843
1 Nov 1968
McDougall A Brown JD

1. Attention is drawn to the importance of taking tangential radiographs of the patella in all cases of injury to the knee, especially when there is difficulty in distinguishing between recurrent dislocation of the patella and tear of a meniscus. 2. New bone formation along the medial side of the patella confirms a diagnosis of recurrent dislocation. 3. The importance of Coleman's original observations is stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 4 | Pages 664 - 667
1 Nov 1958
Carter C Sweetnam R

The family we record draws attention to an association between recurrent dislocation of the patella and joint laxity, which is not confined to the knee. This may pass unrecognised if specific inquiry is not made. In this and other families reported, the joint laxity is inherited, as though due to a dominant gene, but some only of those affected suffer recurrent dislocation of the patella. It is probable that there are other genetically determined causes of recurrent patellar dislocation. In three other families we have seen more than one subject of patellar dislocation, but none had lax ligaments, and two other families have been recorded with no mention of associated joint laxity


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 870 - 876
1 Jul 2006
Khan RJK Fick D Alakeson R Haebich S de Cruz M Nivbrant B Wood D

We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis. The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were four acetabular revisions, three for aseptic loosening and one for deep infection. Another acetabular component was radiologically loose with progressive radiolucent lines in all Gruen zones and was awaiting revision. The overall rate of aseptic loosening was 11.8% (4 of 34). Roentgen stereophotogrammetric analysis in the non-revised components confirmed migration of up to 1.06 mm of translation and 2.32° of rotation at 24 months. There was one case of dislocation and dissociation of the component in the same patient. Of the 34 patients, 33 (97.1%) had no further episodes of dislocation. The constrained acetabular component reported in our study was effective in all but one patient with instability of the hip, but the rate of aseptic loosening was higher than has been reported previously and requires further investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 4 | Pages 559 - 567
1 Nov 1955
Harrison MHM

1. A realignment operation is described for the treatment of recurrent dislocation of the patella. 2. In twenty-three patients (twenty-seven knees) operation prevented further dislocation. The physical and functional condition of the knees two to twenty years after operation is described. 3. Patello-femoral osteoarthritis was not a clinical complication in any of these patients. This finding is discussed. 4. Genu recurvatum developed in four patients operated upon between the ages of ten and thirteen years. The cause of this deformity is discussed. It is concluded that the realignment operation should not be performed under the age of fourteen years. 5. In three patients operation failed to control the recurrent dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 746 - 751
1 Jun 2007
Yamada Y Toritsuka Y Yoshikawa H Sugamoto K Horibe S Shino K

We investigated the three-dimensional morphological differences of the articular surface of the femoral trochlea in patients with recurrent dislocation of the patella and a normal control group using three-dimensional computer models. There were 12 patients (12 knees) and ten control subjects (ten knees). Three-dimensional computer models of the femur, including the articular cartilage, were created. Evaluation was performed on the shape of the articular surface, focused on its convexity, and the proximal and mediolateral distribution of the articular cartilage of the femoral trochlea. The extent of any convexity, and the proximal distribution of the articular cartilage, expressed as the height, were shown by the angles about the transepicondylar axis. The mediolateral distribution of the articular cartilage was assessed by the location of the medial and lateral borders of the articular cartilage. The mean extent of convexity was 24.9° . sd. 6.7° for patients and 11.9° . sd. 3.6° for the control group (p < 0.001). The mean height of the articular cartilage was 91.3° . sd. 8.3° for the patients and 83.3° . sd. 7.7° for the control group (p = 0.03), suggesting a wider convex trochlea in the patients with recurrent dislocation of the patella caused by the proximally-extended convex area. The lateral border of the articular cartilage of the trochlea in the patients was more laterally located than in the control group. Our findings therefore quantitatively demonstrated differences in the shape and distribution of the articular cartilage on the femoral trochlea between patients with dislocation of the patella and normal subjects


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 105 - 111
1 May 2024
Apinyankul R Hong C Hwang KL Burket Koltsov JC Amanatullah DF Huddleston JI Maloney WJ Goodman SB

Aims. Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocation. The aim of this study was to assess the risk for recurrent dislocation after revision THA for instability. Methods. Between 2009 and 2019, 163 patients underwent revision THA for instability at Stanford University Medical Center. Of these, 33 (20.2%) required re-revision due to recurrent dislocation. Cox proportional hazard models, with death and re-revision surgery for periprosthetic infection as competing events, were used to analyze the risk factors, including the size and alignment of the components. Paired t-tests or Wilcoxon signed-rank tests were used to assess the outcome using the Veterans RAND 12 (VR-12) physical and VR-12 mental scores, the Harris Hip Score (HHS) pain and function, and the Hip disability and Osteoarthritis Outcome score for Joint Replacement (HOOS, JR). Results. The median follow-up was 3.1 years (interquartile range 2.0 to 5.1). The one-year cumulative incidence of recurrent dislocation after revision was 8.7%, which increased to 18.8% at five years and 31.9% at ten years postoperatively. In multivariable analysis, a high American Society of Anesthesiologists (ASA) grade (hazard ratio (HR) 2.72 (95% confidence interval (CI) 1.13 to 6.60)), BMI between 25 and 30 kg/m. 2. (HR 4.31 (95% CI 1.52 to 12.27)), the use of specialized liners (HR 5.39 (95% CI 1.97 to 14.79) to 10.55 (95% CI 2.27 to 49.15)), lumbopelvic stiffness (HR 6.03 (95% CI 1.80 to 20.23)), and postoperative abductor weakness (HR 7.48 (95% CI 2.34 to 23.91)) were significant risk factors for recurrent dislocation. Increasing the size of the acetabular component by > 1 mm significantly decreased the risk of dislocation (HR 0.89 (95% CI 0.82 to 0.96)). The VR-12 physical and HHS (pain and function) scores improved significantly at mid term. Conclusion. Patients requiring revision THA for instability are at risk of recurrent dislocation. Higher ASA grades, being overweight, a previous lumbopelvic fusion, the use of specialized liners, and postoperative abductor weakness are significant risk factors. Cite this article: Bone Joint J 2024;106-B(5 Supple B):105–111


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 53 - 58
1 Feb 1948
Palmer I Widén A Sweden S

The purpose of this paper is to call attention to the anterior bone block method of Hybbinette-Eden for recurrent dislocation of the shoulder joint. 1. The operative technique is not difficult, and the after-treatment is short and relatively agreeable for the patient. 2. Sixty of our own cases are described, with four recurrences. The recurrences all occurred as the result of real trauma. In a total of 128 Scandinavian cases there were eight recurrences—that is 6·3 per cent. 3. In our opinion, based on the observations of radiography, arthrography, and operation, it is the compression fracture of the head of the humerus which deserves the name "essential lesion." Destruction of the anterior rim of the glenoid may be very slight, or entirely lacking. No false joint cavity or rupture big enough to receive the head of the humerus was ever observed by arthrography or by inspection during operative exploration. Recurrent dislocation is an intracapsular subluxation, which occurs when the anterior rim of the glenoid slides into the hollow in the humeral head


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 140 - 142
1 Jan 1992
Arnbjornsson A Egund N Rydling O Stockerup R Ryd L

From 1970 to 1978, 29 patients had a unilateral operation for bilateral recurrent dislocation of the patella. We examined 21 of them at a mean of 14 years postoperatively. Eighteen of these patients had evidence of generalised joint laxity. Six of the operated knees and four of the unoperated knees still had recurrent dislocations. The operated knees were clinically worse, with a significantly higher incidence of osteoarthritis. We concluded that the operations used to treat recurrent dislocation of the patella may have had short-term benefits, but did not cure the patients in the long term


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 3 | Pages 508 - 517
1 Aug 1961
Heywood AWB

1. A study has been made of the treatment of recurrent dislocation of the patella in 106 knees in seventy-six patients. 2. In young adults in whom degenerative changes in the knee were not severe at the time of operation transplant of the tibial tubercle gave the best results. 3. In older patients and in those in whom osteoarthritic changes were present in the knee transplant of the tibial tubercle was unsatisfactory, but patellectomy with rerouting of the quadriceps mechanism gave fair results. 4. Tibial tubercle transplant is contra-indicated in children because it may give a recurvatum deformity. 5. When the dislocation is permanent, operation may be unnecessary, but if it becomes inevitable simple patellectomy is the best procedure. 6. The results of plastic operations on the quadriceps expansion and of supracondylar femoral osteotomy are bad. 7. No operation can give consistently good results because the knee is usually congenitally weak, often as part of generalised ligamentous laxity


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 158 - 160
1 Feb 1948
McFarland B

Patellectomy is at present the best operation for recurrent dislocation, not only because the immediate result is excellent, but because it avoids the later arthritis which must inevitably arise if a patella so damaged is retained


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 209 - 213
1 May 1975
Hampson WGJ Hill P

The authors wished to determine the late results of the Hauser operation, with special reference to the development of osteoarthritis. Predisposing factors associated with recurrent dislocation of the patella were also investigated. Thirty-five patients with forty-our surgically treated knees attended for review, ten to twenty-fve (aerage sixteen) years after operation. Two patients had subsequently undergone excision of the patella. Ten patients gave a family history of recurrent dislocation of the patella and seven patients showed generalised joint laxity. Pain was present in eight knees before operation and was present in thirty-three knees (75 per cent) at the time of review. Patellar crepitus was present in thirty-seven out of forty-two knees (88 per cent) at review. Osteoarthritis was present in thirty out of forty-two knees (70 per cent). The incidence increases with time since operation and the present age of the patient. It is concluded that the Hauser operation prevents further dislocation but does not prevent the development of osteoarthritis. It is possible that a simple soft-tissue operation which effectively prevents dislocation might achieve the same results


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 790 - 793
1 Nov 1987
Floyd A Phillips P Khan M Webb J McInnes A Hughes S

The role of muscle function in the aetiology of recurrent dislocation of the patella has been examined. Eleven of the 12 patients we studied had joint hypermobility. Muscle biopsies from eight of nine patients treated by surgery had a predominance of abnormal Type 2C fibres, and three of six patients whose quadriceps muscles were studied by electromyography also had abnormal results. Our preliminary findings suggest that there may be a primary muscular defect in many cases of recurrent dislocation of the patella


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 342 - 345
1 May 1968
Owen R

1. Two patients with recurrent dislocation of the head of the fibula are described. 2. The difficulties in diagnosis are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 103 - 109
1 Feb 1972
Baker RH Carroll N Dewar FP Hall JE

1. Semitendinosus tenodesis with adequate lateral release for recurrent dislocation of the patella has a high success rate and a low complication rate. 2. The technique of operation is simple. 3. Its particular application is in the young patient before epiphysial closure, although it can give good results in the older patient


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 98 - 100
1 Jan 1984
Poll R Duijfjes F

Ten cases of post-traumatic recurrent dislocation of the peroneal tendons were operated on between 1974 and 1982. In all cases the disturbed superior peroneal retinaculum was reconstructed by transposition of the calcaneofibular ligament to the lateral side of the peroneal tendons. The calcaneal insertion of the calcaneofibular ligament was mobilised with a small bone block and reinserted in its bed after the transposition. After an average follow-up of four years all the results were satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 398 - 399
1 May 1986
Rashleigh-Belcher H Cannon

A patient with recurrent dislocation of the hip is described. The initial injury had been a posterior dislocation without associated fracture of the acetabular wall, and the hip had not been immobilised or protected from weight-bearing during treatment. Exploration of the hip for recurrence revealed disruption of the posterosuperior acetabular labrum with formation of a pouch between the posterior acetabular wall and the short rotator muscles. We have found no previous report of this lesion, which resembles a Bankart lesion of the shoulder. Repair using a bone block is described


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 121 - 125
1 Jan 1989
Dandy D Griffiths D

We reviewed 41 knees after arthroscopic lateral release for recurrent dislocation of the patella at a mean follow-up of four years, and graded the results according to the criteria of Crosby and Insall (1976). There were no dislocations after operation in 28 knees (68%); the less satisfactory results were in patients with subluxation of the patella on extension of the knee and those with generalised ligamentous laxity. There were no complications. A characteristic and previously unreported lesion of the patellar surface was seen in eight of the 41 knees. The results of lateral release are better than those reported for other techniques. This treatment, by either open or arthroscopic methods, is recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 648 - 649
1 Jul 1997
Mcharo CN Ochsner PE

An 18-year-old girl with moderate joint laxity presented with recurrent dislocation of the calcaneocuboid joint in both feet. We achieved successful stabilisation on both sides by reconstruction of the ligaments and capsule using the plantaris tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 1 | Pages 114 - 119
1 Feb 1957
Dickson JW Devas MB

1. Fifty cases of recurrent dislocation of the shoulder are reported, operated upon by Bankart and his colleagues from 1925 to 1954. 2. This is the first detailed survey of his patients, some of whom we were unable to trace. 3. It has been confirmed that the operation is successful, and that a full range of movement can be regained after operation, though not in every case. 4. Two cases treated unsuccessfully are described and discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 325 - 327
1 Mar 1998
Hui JHP De SD Balasubramaniam P

Recurrent dislocation of peroneal tendons is uncommon and there are few reports of the long-term results after repair. The Singapore operation, first described in 1985, is an anatomical repair based on the Bankart-like lesion seen in the superior peroneal retinaculum. We reviewed 21 patients after a mean follow-up of 9.3 years, and found no recurrence. Eighteen had good functional results and had returned to their previous levels of vocational and sports activities. The three fair results were due to painful scars or neuromas


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 274 - 276
1 Mar 1988
Bach B Warren R Fronek J

Experimental work has shown that dislocation of the shoulder may involve disruption of the capsule from its lateral humeral attachment. We report two patients with recurrent dislocation due to this injury. Lateral repair gave good results. It is suggested that this injury be considered and looked for when glenoid labral injury is minimal or absent


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 2 | Pages 240 - 243
1 May 1951
Burrows HJ

1. It is suggested that replacement of the costo-clavicular ligament is mechanically an essential part of the operative treatment of recurrent sterno-clavicular dislocation. 2. Tenodesis of the subclavius appears to be the simplest and safest way of achieving such replacement. 3. Two cases are described of recurrent sterno-clavicular dislocation treated by this procedure and capsulorrhaphy. 4. Full function was restored in both cases; and there had been no recurrence at the times of follow-up—three years and six months after operation in the first case, and twelve months after operation in the second. In this case the joint had withstood violence that had shattered the clavicle. 5. Further trial in judiciously selected cases, with report, is suggested


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 4 | Pages 740 - 743
1 Nov 1963
Jeffreys TE

1. Three cases of recurrent dislocation of the patella due to abnormal attachment of the ilio-tibial tract are described. 2. The nature of the abnormality and surgical management are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 887 - 890
1 Aug 2003
Deie M Ochi M Sumen Y Yasumoto M Kobayashi K Kimura H

We investigated the clinical outcome of a reconstructive procedure of the medial patellofemoral ligament for the treatment of habitual or recurrent dislocation of the patella in four children (6 knees), with a minimum follow-up of four years. The technique involves transfer of the tendon of semitendinosus to the patella using the posterior one-third of the femoral insertion of the medial collateral ligament as a pulley. There was no recurrence of dislocation after surgery. The mean Kujala score at follow-up was 96.3 points. Radiological assessment showed that the congruence angle, the tilt angle and the lateral shift radio were restored to normal. The lateral and medial stress shift ratios and the Insall-Salvati ratio remained abnormal. We conclude that this technique can be recommended for the treatment of habitual or recurrent patellar dislocation in children, although hypermobility and patella alta are not fully corrected


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 402 - 405
1 May 1985
Olerud S Karlstrom G

Six patients with recurrent dislocation after total hip replacement have been treated by fixing an additional sector to the acetabular component. Muscle imbalance or unsatisfactory positioning of the prosthetic components (or both) had caused the dislocations in five patients. In the sixth, a schizophrenic, the dislocations were due to the positions in which the patient placed his limb. At operation a sector was cut from another acetabular prosthesis and screwed on to the previously inserted acetabular component in such a position as to prevent further dislocation. This method has been successful and seems a simple alternative to exchange arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1581 - 1585
1 Dec 2007
McConway J O’Brien S Doran E Archbold P Beverland D

Between April 1992 and July 2005, 310 posterior lip augmentation devices were used for the treatment of recurrent dislocation of the hip in 307 patients who had received primary total hip replacements (THRs) using Charnley/Charnley Elite components with a cemented acetabulum. The mean number of dislocations before stabilisation with the device was five (1 to 16) with a mean time to this intervention from the first dislocation of 3.8 years (0 days to 22.5 years). The mean age of the patients at this reconstruction was 75.4 years (39 to 96). A retrospective clinical and radiological review was carried out at a mean follow-up of six years and nine months (4.4 months to 13 years and 7 months). Of the 307 patients, 53 had died at the time of the latest review, with a functioning THR and with the posterior lip augmentation device in situ. There were four revisions (1.3%), one for pain, two for deep infection and one for loosening of the acetabular component. Radiolucent lines around the acetabular component increased in only six cases after insertion of the device which was successful in eliminating instability in 302 patients, with only five further dislocations (1.6%) occurring after its insertion


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1141 - 1149
1 Oct 2024
Saleem J Rawi B Arnander M Pearse E Tennent D

Aims. Extensive literature exists relating to the management of shoulder instability, with a more recent focus on glenoid and humeral bone loss. However, the optimal timing for surgery following a dislocation remains unclear. There is concern that recurrent dislocations may worsen subsequent surgical outcomes, with some advocating stabilization after the first dislocation. The aim of this study was to determine if the recurrence of instability following arthroscopic stabilization in patients without significant glenoid bone loss was influenced by the number of dislocations prior to surgery. Methods. A systematic review and meta-analysis was performed using the PubMed, EMBASE, Orthosearch, and Cochrane databases with the following search terms: ((shoulder or glenohumeral) and (dislocation or subluxation) and arthroscopic and (Bankart or stabilisation or stabilization) and (redislocation or re-dislocation or recurrence or instability)). Methodology followed the PRISMA guidelines. Data and outcomes were synthesized by two independent reviewers, and papers were assessed for bias and quality. Results. Overall, 35 studies including 7,995 shoulders were eligible for analysis, with a mean follow-up of 32.7 months (12 to 159.5). The rate of post-stabilization instability was 9.8% in first-time dislocators, 9.1% in recurrent dislocators, and 8.5% in a mixed cohort. A descriptive analysis investigated the influence of recurrent instability or age in the risk of instability post-stabilization, with an association seen with increasing age and a reduced risk of recurrence post-stabilization. Conclusion. Using modern arthroscopic techniques, patients sustaining an anterior shoulder dislocation without glenoid bone loss can expect a low risk of recurrence postoperatively, and no significant difference was found between first-time and recurrent dislocators. Furthermore, high-risk cohorts can expect a low, albeit slightly higher, rate of redislocation. With the findings of this study, patients and clinicians can be more informed as to the likely outcomes of arthroscopic stabilization within this patient subset. Cite this article: Bone Joint J 2024;106-B(10):1141–1149


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 2 - 4
1 Jan 1992
Jackson A


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 1 | Pages 50 - 54
1 Feb 1953
King T


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 46 - 48
1 Feb 1948


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 6 - 8
1 Feb 1948


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 2 | Pages 203 - 204
1 May 1978
Miller G


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 1 | Pages 55 - 55
1 Feb 1953
Spring WE


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 49 - 52
1 Feb 1948
Watson-Jones R

Summary—Fifty-two cases of exposure of the glenoid labrum are recorded. Fifty-one operations with anterior exposure, followed by capsular reefing and shortening of the subscapularis, were successful. One operation with superior exposure, and without capsular reefing or shortening of the subscapularis, was unsuccessful.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 612 - 617
1 Nov 1954
Wheeldon FT


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 525 - 525
1 May 1990
Gungor T Hallin G


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 675 - 675
1 Aug 1988
Graham G Jenkins A Mintowt-Czyz W


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 632 - 637
1 Nov 1969
Liebenberg F Dommisse GF

1. Two cases of recurrent post-traumatic dislocation of the hip are reported. 2. The literature is reviewed and the rarity of the condition is emphasised. Only twenty-two cases have been previously reported, eleven in adults and eleven in children. 3. The sequence of events leading to recurrent dislocation is not understood but the following important facts emerge. The initial incident could not be distinguished from that causing uncomplicated dislocations. There was a significant delay in reduction in a number of cases. Subsequent dislocations followed minor injury. A large defect in the posterior capsule with a large synovial-lined pouch or false joint was found at operation in both our cases. The ligamentum teres was not seen at operation. The surgeon was unable to redislocate the hips during the operation. 4. In both cases reported here treatment was by excision of the posterior pouch and repair of the capsular defect. 5. Based on the above facts some tentative deductions are made


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 582 - 585
1 Jul 1995
Abe M Ishizu T Nagaoka T Onomura T

Four patients who had injured the lower end of the humerus in childhood with resulting cubitus varus developed recurrent posterior dislocation of the head of the radius after further injury to the elbow. Dislocation occurred when the forearm was supinated and spontaneous reduction took place on pronation. At operation the lateral ligament complex was seen to be lax and elongated. After tightening of the ligament and with a supracondylar osteotomy of the humerus to correct the cubitus varus the recurrent dislocation was eliminated


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1036 - 1038
1 Oct 2024
Tennent TD Watts AC Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 913 - 927
1 Nov 1962
Moseley HF Övergaard B

1 . The concept of the capsular mechanism of the shoulder joint with regard to recurrent anterior dislocation of the shoulder has been defined and a survey of the literature presented. 2. An anatomical, including an embryological, investigation of shoulder joints with special reference to the structure and function of the glenoid labrum and to the variations in the arrangement of the gleno-humeral ligaments and the synovial recesses of the anterior capsular mechanism is reported. The labrum, which is generally believed to be a consistent, fibrocartilaginous structure, is shown to be a redundant portion of capsular tissue and a continuation of the capsule as it attaches to the osseous glenoid rim. The fibrocartilaginous element is confined to a small transition zone at the capsular attachment in the great majority of cases. The great variability in the arrangement of the gleno-humeral ligaments and synovial recesses is stressed, and it is shown that an anterior pouch of variable size is present when the middle gleno-humeral ligament is attached to the scapular neck and not to the labrum. 3. The basic lesions of the anterior capsular mechanism found at operation for recurrent anterior dislocation of the shoulder in twenty-five consecutive cases using a modified Bankart procedure with a standard anterior approach to the joint are reported, and the findings are correlated with the results of the anatomical investigation. In most cases the lesions were found to be of the Bankart type with or without avulsion of the periosteum of the scapular neck. In four cases, however, the soft-tissue attachment to the anterior glenoid rim was intact; in those cases a large synovial pouch was present and the middle gleno-humeral ligament was either not discernible or it arose from the scapular neck. In all cases a postero-lateral notch on the humeral head was palpable and laxity of the subscapularis could be demonstrated. When measured, the joint capacity was always greatly augmented. 4. The present work shows, from a basic standpoint, that Bankart's original idea that the recurrent state was due to the failure of healing of the fractured fibrocartilaginous glenoid labrum is no longer tenable. 5. Finally, the anomalous attachment or the insufficient development of the middle gleno-humeral ligament in certain cases of recurrent anterior shoulder dislocation is shown to provide the anatomical basis for the recurrent state in these cases; this is the weak area in the antero-inferior part of the capsule which has been described in the literature for the past hundred years. Thus we have returned to the original view of Hippocrates


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 687 - 690
1 Sep 1995
Symeonides P Hatzokos I Christoforides J Pournaras J

We measured torsion of the humeral head in 38 patients (40 shoulders) with recurrent anterior dislocation of the shoulder (RADS) and in 40 normal subjects. We found a reduced mean retroversion in the patients with RADS at 4.3 +/- 10.56 degrees (17 degrees anteversion to 32 degrees retroversion) as compared with 16.1 +/- 11.07 degrees in the control group (0 degrees to 49 degrees) (p = 0.0001). There was anteversion in 11 of the 40 shoulders in the RADS group (27.5%) and in none of the control group. The first dislocation had occurred after minimal force in 18 of 25 patients with less than 10 degrees retroversion, but in only three of 15 with over 10 degrees retroversion. We conclude that decreased retroversion of the humeral head is often associated with RADS and with first dislocation of the shoulder caused by minimal force


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 476 - 483
1 Aug 1972
Symeonides PP

1. The pathogenesis of recurrent anterior dislocation of the shoulder has been studied at operation and by experiments on cadavers. 2. Lesions of the subscapularis muscle leading to lengthening and laxity have been demonstrated. 3. This lengthening is the prime factor in producing instability of the shoulder; capsular and bony defects are no more than subsidiary causes. 4. Good results have been obtained by a procedure based on this theory of etiology


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 798 - 801
1 Nov 1988
McAuliffe T Pangayatselvan T Bayley I

We have reviewed 36 patients who had recurrent anterior dislocation of the shoulder after a previous anterior repair and analysed the various causes of failure. It was found that failure could have been avoided in virtually all of the patients by correct pre-operative diagnosis, selection of the appropriate operation and its proper execution. The further management of these patients is described and suggestions are made as to means of reducing the incidence of failure after primary operation


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 111 - 114
1 Jan 1987
Ahmadain A

The modified Magnuson-Stack procedure of lateral and distal transfer of the insertion of the subscapularis muscle was used in 38 consecutive patients with recurrent anterior dislocation of the shoulder, all of whom have been followed-up for a minimum of three years. There was only one failure; the other 37 patients had an excellent or satisfactory result with an adequate range of movement. Bankart and Hill-Sachs lesions were not a constant finding but subscapularis laxity was detected in almost every case, an observation that helps to confirm its central role as a cause of recurrence


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 2 | Pages 203 - 207
1 May 1958
Jones V

1. A case of recurrent posterior subluxation of the shoulder is described. After failure of a soft-tissue repair, a posterior bone block operation was performed.

2. The distinction between traumatic dislocations with tearing of the capsule or of the glenoid labrum, and habitual luxations from laxity of the capsule, is emphasised. Although the anterior rim of the glenoid was detached in this case, it is considered to fall into the latter category.

3. A posterior bone block provides a simple and efficient form of repair in this type of case. It is free from the disadvantage of causing limitation of rotation at the shoulder joint; it employs a principle which might well merit more application than at present in the repair of anterior dislocations.


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 3 | Pages 531 - 532
1 Aug 1948
Zadik FR


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 2 | Pages 401 - 402
1 May 1970
Bonnin JG


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 1 | Pages 56 - 56
1 Feb 1953
Hall RM



The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 423 - 425
1 Apr 2020
Hoggett L Cross C Helm A

Aims. Dislocation remains a significant complication after total hip arthroplasty (THA), being the third leading indication for revision. We present a series of acetabular revision using a dual mobility cup (DMC) and compare this with our previous series using the posterior lip augmentation device (PLAD). Methods. A retrospective review of patients treated with either a DMC or PLAD for dislocation in patients with a Charnley THA was performed. They were identified using electronic patient records (EPR). EPR data and radiographs were evaluated to determine operating time, length of stay, and the incidence of complications and recurrent dislocation postoperatively. Results. A total of 28 patients underwent revision using a DMC for dislocation following Charnley THA between 2013 and 2017. The rate of recurrent dislocation and overall complications were compared with those of a previous series of 54 patients who underwent revision for dislocation using a PLAD, between 2007 and 2013. There was no statistically significant difference in the mean distribution of sex or age between the groups. The mean operating time was 71 mins (45 to 113) for DMCs and 43 mins (21 to 84) for PLADs (p = 0.001). There were no redislocations or revisions in the DMC group at a mean follow-up of 55 months (21 to 76), compared with our previous series of PLAD which had a redislocation rate of 16% (n = 9) and an overall revision rate of 25% (n = 14, p = 0.001) at a mean follow-up of 86 months (45 to 128). Conclusion. These results indicate that DMC outperforms PLAD as a treatment for dislocation in patients with a Charnley THA. This should therefore be the preferred form of treatment for these patients despite a slightly longer operating time. Work is currently ongoing to review outcomes of DMC over a longer follow-up period. PLAD should be used with caution in this patient group with preference given to acetabular revision to DMC. Cite this article: Bone Joint J 2020;102-B(4):423–425


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. Methods. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification. Results. A total of seven stems (4.2%) were revised during the study period: one for aseptic loosening, three for periprosthetic fracture, two for infection, and one for recurrent dislocation. At 20 years, survival with revision of the stem for any indication and for aseptic loosening as the endpoint was 96.0% (95% confidence interval (CI) 92.6 to 99.5) and 98.4% (95% CI 96.2 to 100), respectively. At 25 years, the corresponding rates of survival were 94.5% (95% CI 89.9 to 99.3) and 98.1% (95% CI 95.7 to 99.6), respectively. There was radiological evidence of stable bony fixation in 86 stems (76.1%) and evidence of loosening in four (3.5%) at 20 years. All patients with radiological evidence of loosening were asymptomatic. Conclusion. The Omnifit HA femoral stem offered promising long-term survival into the third decade. Cite this article: Bone Joint J 2024;106-B(3 Supple A):110–114


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 520 - 526
1 Apr 2015
Roberts SB Beattie N McNiven ND Robinson CM

The natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients remains unclear and there is no consensus for management of these patients. The objectives of this study were to report the natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients and to identify the risk factors for recurrent dislocation. We reviewed prospectively-collected clinical and radiological data on 133 adolescent patients diagnosed with a primary anterior dislocation of the glenohumeral joint who had been managed non-operatively at our hospital between 1996 and 2008. There were 115 male (86.5%) and 18 female patients (13.5%) with a mean age of 16.3 years (13 to 18) and a mean follow-up of 95.2 months (1 to 215). During follow-up, 102 (absolute incidence of 76.7%) patients had a recurrent dislocation. The median interval between primary and recurrent dislocation was ten months (95% CI 7.4 to 12.6). Applying survival analysis the likelihood of having a stable shoulder one year after the initial injury was 59% (95% CI 51.2 to 66.8), 38% (95% CI 30.2 to 45.8%) after two years, 21% (95% CI 13.2 to 28.8) after five years, and 7% (95% CI 1.1 to 12.9) after ten years. Neither age nor gender significantly predicted recurrent dislocation during follow-up. We conclude that adolescent patients with a primary anterior dislocation of the glenohumeral joint have a high rate of recurrent dislocation, which usually occurs within two years of their initial injury: these patients should be considered for early operative stabilisation. Cite this article: Bone Joint J 2015;97-B:520–6


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 123 - 126
1 Jun 2019
El-Husseiny M Masri B Duncan C Garbuz DS

Aims. We investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores. Patients and Methods. We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications. Results. At ten years, the Kaplan–Meier survivorship for dislocation was 95.6% (95% confidence interval (CI) 90 to 98), with 101 patients at risk. At 20 years, the survivorship for dislocation was 90.6% (95% CI 81.0 to 95.5), with one patient at risk. Eight patients (7.2%) had a dislocation of their constrained liners. At ten years, the survival to any event was 89.4% (95% CI 82 to 93.8), with 96 patients at risk. At 20 years, the survival to any event was 82.5% (95% CI 71.9 to 89.3), with one patient at risk. Five hips (4.4%) had deep infection. Two patients (1.8%) developed dissociated constraining rings with pain but without dislocation, which required re-operation. Two patients (1.8%) had periprosthetic femoral fractures, without dislocation, that were treated by revision stems along with exchange of the well-functioning constrained liners. Conclusion. Constrained tripolar liners used at revision hip arthroplasty provided favourable results in the long term for treatment of recurrent dislocation and for patients at high risk of dislocation. Cite this article: Bone Joint J 2019;101-B(6 Supple B):123–126


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 187 - 193
1 Feb 2016
Lash NJ Whitehouse MR Greidanus NV Garbuz DS Masri BA Duncan CP

Aims. We present a case series of ten metal-on-polyethylene total hip arthroplasties (MoP THAs) with delayed dislocation associated with unrecognised adverse local tissue reaction due to corrosion at the trunnion and pseudotumour formation. . Methods. The diagnosis was not suspected in nine of the ten patients (six female/four male; mean age 66 years), despite treatment in a specialist unit (mean time from index surgery to revision was 58 months, 36 to 84). It was identified at revision surgery and subsequently confirmed by histological examination of resected tissue. Pre-operative assessment and culture results ruled out infection. A variety of treatment strategies were used, including resection of the pseudotumour and efforts to avoid recurrent dislocation. . Results. The rate of complications was high and included three deep infections, two patients with recurrent dislocation, and one recurrent pseudotumour. . Conclusion. This series (mean follow-up of 76 months following index procedure and 19 months following revision THA) demonstrates that pseudotumour is an infrequent but important contributor to delayed instability following MoP THA. It is easy to overlook in the differential diagnosis, especially if the alignment of the components is less than optimal, leading to an assumption that malalignment is the cause of the dislocation. The instability is likely to be multifactorial and the revision surgery is complex. Take home message: Due to the high complication rate associated with revision in this cohort, the diagnosis should be borne in mind when counselling patients regarding the risks of revision surgery. . Cite this article: Bone Joint J 2016;98-B:187–93


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 321 - 326
1 Mar 2009
Kotwal RS Ganapathi M John A Maheson M Jones SA

We have studied the natural history of a first episode of dislocation after primary total hip replacement (THR) to clarify the incidence of recurrent dislocation, the need for subsequent revision and the quality of life of these patients. Over a six-year period, 99 patients (101 hips) presented with a first dislocation of a primary THR. A total of 61 hips (60.4%) had dislocated more than once. After a minimum follow-up of one year, seven patients had died. Of the remaining 94 hips (92 patients), 47 underwent a revision for instability and one awaits operation (51% in total). Of these, seven re-dislocated and four needed further surgery. The quality of life of the patients was studied using the Oxford Hip Score and the EuroQol-5 Dimension (EQ-5D) questionnaire. A control group of patients who had not dislocated was also studied. At a mean follow-up of 4.5 years (1 to 20), the mean Oxford Hip Score was 26.7 (15 to 47) after one episode of dislocation, 27.2 (12 to 45) after recurrent dislocation, 34.5 (12 to 54) after successful revision surgery, 42 (29 to 55) after failed revision surgery and 17.4 (12 to 32) in the control group. The EuroQol-5 dimension questionnaire revealed more health problems in patients undergoing revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1202 - 1208
1 Sep 2012
Howells NR Barnett AJ Ahearn N Ansari A Eldridge JD

We report a prospective analysis of clinical outcome in patients treated with medial patellofemoral ligament (MPFL) reconstruction using an autologous semitendinosus graft. The technique includes superolateral portal arthroscopic assessment before and after graft placement to ensure correct graft tension and patellar tracking before fixation. Between October 2005 and October 2010, a total of 201 consecutive patients underwent 219 procedures. Follow-up is presented for 211 procedures in 193 patients with a mean age of 26 years (16 to 49), and mean follow-up of 16 months (6 to 42). Indications were atraumatic recurrent patellar dislocation in 141 patients, traumatic recurrent dislocation in 50, pain with subluxation in 14 and a single dislocation with persistent instability in six. There have been no recurrent dislocations/subluxations. There was a statistically significant improvement between available pre- and post-operative outcome scores for 193 patients (all p < 0.001). Female patients with a history of atraumatic recurrent dislocation and all patients with history of previous surgery had a significantly worse outcome (all p < 0.05). The indication for surgery, degree of dysplasia, associated patella alta, time from primary dislocation to surgery and evidence of associated cartilage damage at operation did not result in any significant difference in outcome. This series adds considerably to existing evidence that MPFL reconstruction is an effective surgical procedure for selected patients with patellofemoral instability


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 918 - 921
1 Jul 2009
Finestone A Milgrom C Radeva-Petrova DR Rath E Barchilon V Beyth S Jaber S Safran O

We undertook a prospective study in 51 male patients aged between 17 and 27 years to ascertain whether immobilisation after primary traumatic anterior dislocation of the shoulder in external rotation was more effective than immobilisation in internal rotation in preventing recurrent dislocation in a physically active population. Of the 51 patients, 24 were randomised to be treated by a traditional brace in internal rotation and 27 were immobilised in external rotation of 15° to 20°. After immobilisation, the patients undertook a standard regime of physiotherapy and were then assessed clinically for evidence of instability. When reviewed at a mean of 33.4 months (24 to 48) ten from the external rotation group (37%) and ten from the internal rotation group (41.7%) had sustained a futher dislocation. There was no statistically significant difference (p = 0.74) between the groups. Our findings show that external rotation bracing may not be as effective as previously reported in preventing recurrent anterior dislocation of the shoulder


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 898 - 902
1 Jul 2018
Lachiewicz PF O’Dell JA

Aims. To report our experience with trunnion corrosion following metal-on-polyethylene total hip arthroplasty, in particular to report the spectrum of presentation and determine the mean time to presentation. Patients and Methods. We report the presenting symptoms and signs, intraoperative findings, and early results and complications of operative treatment in nine patients with a mean age of 74 years (60 to 86). The onset of symptoms was at a mean of seven years (3 to 18) after index surgery. Results. Patients presented with a variety of symptoms including pain, limp and rash. The preoperative mean serum cobalt level was 7.1 ppb (2.2 to 12.8) and mean serum chromium level was 2.2 ppb (0.5 to 5.2). Metal artifact reduction sequence (MARS) MRI showed fluid collection and possible pseudotumour formation in five hips, fluid collection in two hips, and synovitis/debris in one hip, with no MRI in one patient. Acetabular revision was performed in three patients, six patients underwent liner and head exchange only. The postoperative metal levels decreased in all patients: mean cobalt 0.5 ppb (0 to 1.8) and mean chromium 0.9 ppb (0 to 2.6) at a mean of five months (3 to 8) postoperatively. Seven patients had good pain relief and no complications at one year. There were two major complications requiring reoperation: acute infection at six weeks, for which the patient required two-stage reimplantation; and recurrent dislocation, for which the patient was revised to a dual mobility component. Conclusion. Trunnion corrosion in metal-on-polyethylene THA has a range of presenting symptoms, and may present later than previously described. A high index of suspicion is warranted, and serum cobalt and chromium levels are recommended for diagnosis. Patients should be counselled about possible postoperative complications. Cite this article: Bone Joint J 2018;100-B:898–902


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 3 | Pages 424 - 435
1 Aug 1966
Reeves B

1. Arthrography demonstrates two types of injury to the capsule in acute anterior dislocations of the shoulder. 2. The first is a capsular rupture which does not appear to lead to recurrent dislocation of the shoulder unless there is concomitant humeral head damage. In this group healing is complete in ten days and it should be safe to start exercises early. 3. The second is associated with labral detachment from the glenoid and most heal with immobilisation for three weeks. Failure to heal leads to recurrent dislocation. It is not known whether immobilisation had any influence on healing of the lesion in these patients and this remains the subject of further investigation. 4. In recurrent anterior dislocation of the shoulder there is constant enlargement of the subscapular bursa, the outline of which becomes continuous with the inferior pouch. Axial arthrographs show either an absence of the glenoid labral outline or an enlarged entrance to the subscapular bursa. 5. Ruptures of the supraspinatus portion of the tendinous cuff were seen in five patients out of a total of twenty-seven acute dislocations, suggesting that this associated injury is more common than was previously believed. POSTERIOR DISLOCATIONS. 6. When the dislocation is voluntary there is marked elasticity of the capsule but the joint is only unstable in one direction when examined under anaesthesia. Both shoulders appear equally affected when examined radiologically under general anaesthesia even though the patient only has the ability to dislocate one. 7. All patients with voluntary dislocation had a curious voluntary muscle control and were able to contract the anterior and posterior parts of deltoid separately. Each dislocation was preceded by scapular movement. 8. No evidence of increased joint laxity was found in other joints in any of the patients. 9. In two patients with acute dislocations the defect of the humeral head was seen after the initial dislocation and in the third patient it occurred at the time of the second dislocation. In all three there was a spill of fluid beneath the subscapularis but no leakage into the axilla as occurred in anterior dislocation with capsular rupture. The capacity for healing appeared greater than in anterior dislocations with labral detachment; one patient treated in a sling had a better functional result than another treated with the shoulder in lateral rotation


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1706 - 1712
1 Dec 2014
Bus MPA Boerhout EJ Bramer JAM Dijkstra PDS

Peri-acetabular tumour resections and their subsequent reconstruction are among the most challenging procedures in orthopaedic oncology. Despite the fact that a number of different pelvic endoprostheses have been introduced, rates of complication remain high and long-term results are mostly lacking. . In this retrospective study, we aimed to evaluate the outcome of reconstructing a peri-acetabular defect with a pedestal cup endoprosthesis after a type 2 or type 2/3 internal hemipelvectomy. A total of 19 patients (11M:8F) with a mean age of 48 years (14 to 72) were included, most of whom had been treated for a primary bone tumour (n = 16) between 2003 and 2009. After a mean follow-up of 39 months (28 days to 8.7 years) seven patients had died. After a mean follow-up of 7.9 years (4.3 to 10.5), 12 patients were alive, of whom 11 were disease-free. Complications occurred in 15 patients. Three had recurrent dislocations and three experienced aseptic loosening. There were no mechanical failures. Infection occurred in nine patients, six of whom required removal of the prosthesis. Two patients underwent hindquarter amputation for local recurrence. The implant survival rate at five years was 50% for all reasons, and 61% for non-oncological reasons. The mean Musculoskeletal Tumor Society score at final follow-up was 49% (13 to 87). Based on these poor results, we advise caution if using the pedestal cup for reconstruction of a peri-acetabular tumour resection. Cite this article: Bone Joint J 2014;96-B:1706–12


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 603 - 608
1 May 2012
Vasukutty NL Middleton RG Matthews EC Young PS Uzoigwe CE Minhas THA

We present our experience with a double-mobility acetabular component in 155 consecutive revision total hip replacements in 149 patients undertaken between 2005 and 2009, with particular emphasis on the incidence of further dislocation. The mean age of the patients was 77 years (42 to 89) with 59 males and 90 females. In all, five patients died and seven were lost to follow-up. Indications for revision were aseptic loosening in 113 hips, recurrent instability in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean follow-up was 42 months (18 to 68). Three hips (2%) in three patients dislocated within six weeks of surgery; one of these dislocated again after one year. All three were managed successfully with closed reduction. Two of the three dislocations occurred in patients who had undergone revision for recurrent dislocation. All three were found at revision to have abductor deficiency. There were no dislocations in those revised for either aseptic loosening or sepsis. These results demonstrate a good mid-term outcome for this component. In the 29 patients revised for instability, only two had a further dislocation, both of which were managed by closed reduction


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1031 - 1037
1 Aug 2015
da Assunção RE Pollard TCB Hrycaiczuk A Curry J Glyn-Jones S Taylor A

Periprosthetic femoral fracture (PFF) is a potentially devastating complication after total hip arthroplasty, with historically high rates of complication and failure because of the technical challenges of surgery, as well as the prevalence of advanced age and comorbidity in the patients at risk. This study describes the short-term outcome after revision arthroplasty using a modular, titanium, tapered, conical stem for PFF in a series of 38 fractures in 37 patients. The mean age of the cohort was 77 years (47 to 96). A total of 27 patients had an American Society of Anesthesiologists grade of at least 3. At a mean follow-up of 35 months (4 to 66) the mean Oxford Hip Score (OHS) was 35 (15 to 48) and comorbidity was significantly associated with a poorer OHS. All fractures united and no stem needed to be revised. Three hips in three patients required further surgery for infection, recurrent PFF and recurrent dislocation and three other patients required closed manipulation for a single dislocation. One stem subsided more than 5 mm but then stabilised and required no further intervention. . In this series, a modular, tapered, conical stem provided a versatile reconstruction solution with a low rate of complications. Cite this article: Bone Joint J 2015;97-B:1031–7


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 307 - 312
1 Mar 2016
Maggs JL Smeatham A Whitehouse SL Charity J Timperley AJ Gie GA

Aims. We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). Patients and Methods. A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. Results. There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. . Oxford and Harris hip scores demonstrated significant clinical improvement (all p < 0.001). Radiolucent lines were present in 37 (36%) of the 103 acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. . Conclusion. Kaplan–Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. Take home message: The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty. . Cite this article: Bone Joint J 2016;98-B:307–12


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1427 - 1430
1 Oct 2011
Lindgren JU Brismar BH Wikstrom AC

A 70-year-old man with an uncemented metal-on-polyethylene total hip prosthesis underwent revision arthroplasty 33 months later because of pain, swelling and recurrent dislocation. There appeared to be corrosion and metal release from the prosthetic head, resulting in pseudotumour formation and severe local soft-tissue destruction. The corrosion occurred at the junction between the titanium-molybdenum-zirconium-iron taper and the cobalt-chrome-molybdenum head, but the mechanism was unproven


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 752 - 760
1 Jun 2007
Yamada Y Toritsuka Y Horibe S Sugamoto K Yoshikawa H Shino K

We used three-dimensional movement analysis by computer modelling of knee flexion from 0° to 50° in 14 knees in 12 patients with recurrent patellar dislocation and in 15 knees in ten normal control subjects to compare the in vivo three-dimensional movement of the patella. Flexion, tilt and spin of the patella were described in terms of rotation angles from 0°. The location of the patella and the tibial tubercle were evaluated using parameters expressed as percentage patellar shift and percentage tubercle shift. Patellar inclination to the femur was also measured and patellofemoral contact was qualitatively and quantitatively analysed. The patients had greater values of spin from 20° to 50°, while there were no statistically significant differences in flexion and tilt. The patients also had greater percentage patellar shift from 0° to 50°, percentage tubercle shift at 0° and 10° and patellar inclination from 0° to 50° with a smaller oval-shaped contact area from 20° to 50° moving downwards on the lateral facet. Patellar movement analysis using a three-dimensional computer model is useful to clearly demonstrate differences between patients with recurrent dislocation of the patella and normal control subjects


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 227 - 229
1 Feb 2007
Maheshwari R Sharma H Duncan RDD

There are few reports describing dislocation of the metacarpophalangeal joint of the thumb in children. This study describes the clinical features and outcome of 37 such dislocations and correlates the radiological pattern with the type of dislocation. The mean age at injury was 7.3 years (3 to 13). A total of 33 children underwent closed reduction (11 under general anaesthesia). Four needed open reduction in two of which there was soft-tissue interposition. All cases obtained a good result. There was no infection, recurrent dislocation or significant stiffness. So-called ‘simple complete’ dislocations that present with the classic radiological finding of the joint at 90° dorsal angulation may be ‘complex complete’ injuries and require open reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1499 - 1504
1 Nov 2009
Herbertsson P Hasserius R Josefsson PO Besjakov J Nyquist F Nordqvist A Karlsson MK

A total of 14 women and seven men with a mean age of 43 years (18 to 68) who sustained a Mason type IV fracture of the elbow, without an additional type II or III coronoid fracture, were evaluated after a mean of 21 years (14 to 46). Primary treatment included closed elbow reduction followed by immobilisation in a plaster in all cases, with an additional excision of the radial head in 11, partial resection in two and suturing of the annular ligament in two. Delayed radial head excision was performed in two patients and an ulnar nerve transposition in one. The uninjured elbows served as controls. Nine patients had no symptoms, 11 reported slight impairment, and one severe impairment of the elbow. Elbow flexion was impaired by a mean of 3° (. sd. 4) and extension by a mean of 9° (. sd. 4) (p < 0.01). None experienced chronic elbow instability or recurrent dislocation. There were more degenerative changes in the formerly injured elbows, but none had developed a reduction in joint space. We conclude that most patients with a Mason type IV fracture of the elbow report a good long-term outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1172 - 1177
1 Sep 2007
Benoit B Laflamme GY Laflamme GH Rouleau D Delisle J Morin B

We retrospectively reviewed the operative treatment carried out between 1988 and 1994 of eight patients with habitual patellar dislocation. In four the condition was bilateral. All patients had recurrent dislocation with severe functional disability. The surgical technique involved distal advancement of the patella by complete mobilisation of the patellar tendon, lateral release and advancement of vastus medialis obliquus. The long-term results were assessed radiologically, clinically and functionally using the Lysholm knee score, by an independent observer. The mean age at operation was 10.3 years (7 to 14) with a mean follow-up of 13.5 years (11 to 16). One patient required revision. At the latest follow-up, all patellae were stable and knees functional with a mean Lysholm knee score of 98 points (95 to 100). In those aged younger than ten years at operation there was a statistically significant improvement in the sulcus angle at the latest follow-up (Student’s t-test, p = 0.001). Two patients developed asymptomatic patella infera as a late complication. This technique offers a satisfactory treatment for the immature patient presenting with habitual patellar dislocation associated with patella alta. If performed early, we believe that remodelling of the shallow trochlea may occur, adding intrinsic patellofemoral stability


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 158 - 162
1 Feb 2012
Sternheim A Backstein D Kuzyk PRT Goshua G Berkovich Y Safir O Gross AE

We report the use of porous metal acetabular revision shells in the treatment of contained bone loss. The outcomes of 53 patients with ≤ 50% acetabular bleeding host bone contact were compared with a control group of 49 patients with > 50% to 85% bleeding host bone contact. All patients were treated with the same type of trabecular metal acetabular revision shell. The mean age at revision was 62.4 years (42 to 80) and the mean follow-up of both groups was 72.4 months (60 to 102). Clinical, radiological and functional outcomes were assessed. There were four (7.5%) mechanical failures in the ≤ 50% host bone contact group and no failures in the > 50% host bone contact group (p = 0.068). Out of both groups combined there were four infections (3.9%) and five recurrent dislocations (4.9%) with a stable acetabular component construct that were revised to a constrained liner. Given the complexity of the reconstructive challenge, porous metal revision acetabular shells show acceptable failure rates at five to ten years’ follow-up in the setting of significant contained bone defects. This favourable outcome might be due to the improved initial stability achieved by a high coefficient of friction between the acetabular implant and the host bone, and the high porosity, which affords good bone ingrowth


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1688 - 1692
1 Dec 2014
Bouliane M Saliken D Beaupre LA Silveira A Saraswat MK Sheps DM

In this study we evaluated whether the Instability Severity Index Score (ISIS) and the Western Ontario Shoulder Instability Index (WOSI) could detect those patients at risk of failure following arthroscopic Bankart repair. Between April 2008 and June 2010, the ISIS and WOSI were recorded pre-operatively in 110 patients (87 male, 79%) with a mean age of 25.1 years (16 to 61) who underwent this procedure for recurrent anterior glenohumeral instability. . A telephone interview was performed two-years post-operatively to determine whether patients had experienced a recurrent dislocation and whether they had returned to pre-injury activity levels. In all, six (5%) patients had an ISIS > 6 points (0 to 9). Of 100 (91%) patients available two years post-operatively, six (6%) had a recurrent dislocation, and 28 (28%) did not return to pre-injury activity. No patient who dislocated had an ISIS > 6 (p = 1.0). There was no difference in the mean pre-operative WOSI in those who had a re-dislocation and those who did not (p = 0.99). The pre-operative WOSI was significantly lower (p = 0.02) in those who did not return to pre-injury activity, whereas the ISIS was not associated with return to pre-injury activity (p = 0.13). . In conclusion, neither the pre-operative ISIS nor WOSI predicted recurrent dislocation within two years of arthroscopic Bankart repair. Patients with a lower pre-operative WOSI were less likely to return to pre-injury activity. Cite this article: Bone Joint J 2014; 96-B:1688–92


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 68 - 74
1 Jan 2019
Klemt C Toderita D Nolte D Di Federico E Reilly P Bull AMJ

Aims. Patients with recurrent anterior dislocation of the shoulder commonly have an anterior osseous defect of the glenoid. Once the defect reaches a critical size, stability may be restored by bone grafting. The critical size of this defect under non-physiological loading conditions has previously been identified as 20% of the length of the glenoid. As the stability of the shoulder is load-dependent, with higher joint forces leading to a loss of stability, the aim of this study was to determine the critical size of an osseous defect that leads to further anterior instability of the shoulder under physiological loading despite a Bankart repair. Patients and Methods. Two finite element (FE) models were used to determine the risk of dislocation of the shoulder during 30 activities of daily living (ADLs) for the intact glenoid and after creating anterior osseous defects of increasing magnitudes. A Bankart repair was simulated for each size of defect, and the shoulder was tested under loading conditions that replicate in vivo forces during these ADLs. The critical size of a defect was defined as the smallest osseous defect that leads to dislocation. Results. The FE models showed a high risk of dislocation during ADLs after a Bankart repair for anterior defects corresponding to 16% of the length of the glenoid. Conclusion. This computational study suggests that bone grafting should be undertaken for an anterior osseous defect in the glenoid of more than 16% of its length rather than a solely soft-tissue procedure, in order to optimize stability by restoring the concavity of the glenoid


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1320 - 1326
1 Oct 2011
Regis D Sandri A Bonetti I Braggion M Bartolozzi P

Revision after failed femoral components may be technically demanding due to loss of peri-prosthetic bone. This retrospective study evaluated the long-term results of femoral revision using the cementless Wagner Self-Locking stem. Between 1992 and 1998, 68 consecutive hips in 66 patients underwent femoral revision using this implant. A total of 25 patients died from unrelated causes without further revision; the remaining 41 hips in 41 patients (12 men and 29 women) with a mean age of 61 years (29 to 80) were reviewed at a mean follow-up of 13.9 years (10.4 to 15.8). A transfemoral approach was used in 32 hips. A total of five stems required further revision because of infection in two, progressive subsidence in two and recurrent dislocation in one. Four hips had dislocated and eight stems had subsided ≥ 10 mm. The mean Harris hip score improved from 33 points pre-operatively to 75 points at final follow-up (p < 0.001). In all, 33 stems (91.7%) showed radiological signs of stable bone fixation. The cumulative survival rates at 15.8 years with femoral revision for any reason and for stem failure as the endpoints were 92.0% (95% confidence interval (CI) 86.0% to 98.4%) and 96.6% (95% CI 92.2% to 100%), respectively. The survivorship with revision and ≥ 10 mm migration of the stem as the endpoint was 83.6% (95% CI 76.6% to 91.4%). This study shows quite good survival and moderate clinical outcome when using a monoblock tapered titanium stem for supporting the regeneration of bone in complex revision hip surgery.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1207 - 1213
1 Sep 2014
te Stroet MAJ Bronsema E Rijnen WHC Gardeniers JWM Schreurs BW

In this retrospective study, we investigated the results of revision total hip replacement (THR) using a cemented long-stemmed Exeter femoral component, with a minimum length of 205 mm in patients with extensive femoral bone defects. The study included 37 consecutive patients with a mean age of 76 years (39 to 93) and a mean follow-up of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative Endo-Klinik score of 3 or 4. Impaction bone grafting was used in 24 patients (65%). At the time of evaluation, 22 patients (59%) were still alive and were evaluated clinically and radiologically. A total of 14 patients died during follow-up and their data were included until the time of their death. One reconstruction failed after five years and five months owing to recurrent dislocation: the hip was converted to an excision arthroplasty. Intra-operative fractures or fissures were encountered in nine patients (24%), but none occurred during impaction of the bone graft. Post-operative peri-prosthetic fractures occurred in two patients (5%); both were treated with plate fixation. At nine years, survival with the endpoint of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%). There were no re-revisions for aseptic loosening. The survival of long stem cemented femoral components following revision THR is satisfactory in a fragile population with extensive femoral defects. Cite this article: Bone Joint J 2014; 96-B:1207–13


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 59 - 65
1 May 2024
Liu WKT Cheung A Fu H Chan PK Chiu KY

Aims

Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.

Methods

Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 306 - 309
1 Mar 2005
Ito H Matsuno T Minami A

We present the medium-term results of hybrid total hip arthroplasties using pre-coated stems with a second-generation cementing technique. The 128 hips in 111 patients (18 men and 93 women) were followed up at a mean of 11 years after surgery. The mean age at the time of surgery was 61 years. Both components of one hip were removed at ten months after surgery for infection. None of the other 127 femoral components showed possible, probable, or definite loosening at the most recent follow-up. Five acetabular components were revised for aseptic loosening, recurrent dislocation, or displacement of the polyethylene liner from the metal shell. The mean Harris hip score at follow-up was 84 points. A pre-coated femoral component with a second-generation cementing technique provides good clinical function and survival in the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 916 - 920
1 Jul 2005
Ebied A Hoad-Reddick DA Raut V

A reduced femoral offset in total hip replacement has been thought to be disadvantageous. We reviewed the results of 54 consecutive primary total hip replacements in 49 patients (mean age of 68 years) performed between August 1990 and December 1994, with a mean follow-up of 8.8 years (. sd. 2.1). The mean pre-operative femoral offset for these hips was 41 mm (. sd. 7.4). All patients received a low-offset Charnley stem and a polyethylene cup inserted by a single surgeon. At their latest follow-up, surviving patients had a significant improvement in the performance of their hip. Three had undergone revision, one each for deep infection, recurrent dislocation and late pain with subluxation. No hips had been revised, or were at risk of revision, for aseptic loosening. The mean annual linear rate of wear was 0.2 mm (. sd. 0.08) for the whole group. There was no correlation between the pre-operative femoral offset and the post-operative rate of wear. Our survivorship estimate was 91% when revision for any reason was taken as an end-point, but 100% if aseptic loosening was considered as the end-point. Our study demonstrates that a low-offset femoral stem can produce good, medium-term results


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1653 - 1657
1 Dec 2005
Wedin R Bauer HCF

We report positive and negative factors associated with the most commonly-used methods of reconstruction after pathological fracture of the proximal femur. The study was based on 142 patients treated surgically for 146 metastatic lesions between 1996 and 2003. The local rate of failure was 10.3% (15 of 146). Of 37 operations involving osteosynthetic devices, six failed (16.2%) compared with nine (8.3%) in 109 operations involving endoprostheses. Of nine cases of prosthetic failure, four were due to periprosthetic fractures and three to recurrent dislocation. In the osteosynthesis group, three (13.6%) of 22 reconstruction nails failed. The two-year risk of re-operation after any type of osteosynthesis was 0.35 compared with 0.18 after any type of endoprosthetic reconstruction (p = 0.07). Endoprosthetic reconstructions are preferable to the use of reconstruction nails and other osteosynthetic devices for the treatment of metastatic lesions in the proximal third of the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 623 - 627
1 May 2005
Kim Y

Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration of the clinical and radiological follow-up was 19.4 years (18 to 20). The mean Harris hip score initially improved from 55 points before to 95 points at two years after operation, but subsequently decreased to 91 points after six years, 87 points after 11.2 years, and 85 points after 19.4 years. At the final follow-up, 23 hips (18%) of the entire cohort and 21% of survivors had undergone revision because of loosening or osteolysis of the acetabular component and eight hips (6%) of the entire cohort and 7% of survivors for loosening or osteolysis of the femoral component. Only four femoral components (4%) were revised for isolated aseptic loosening without osteolysis and two (2%) for recurrent dislocation. On the basis of these long-term results, the porous-coated anatomic femoral component survived for a minimum of 18 years after operation while the acetabular component was less durable. The findings identify the principles of uncemented joint replacement which can be applied to current practice


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 760 - 768
1 Jun 2011
ten Broeke RHM Alves A Baumann A Arts JJC Geesink RGT

Four uncemented Symax hip stems were extracted at three weeks and nine, 13 and 32 months, respectively, for reasons other than loosening. The reasons for implant removal were infection in two cases, recurrent dislocation in one and acetabular fracture in one. They were analysed to assess the effect and behaviour of an electrochemically deposited, completely resorbable biomimetic BONIT-hydroxyapatite (HA) coating (proximal part) and a DOTIZE surface treatment (distal part) using qualitative histology, quantitative histomorphometry and scanning electron microscopy (SEM). Early and direct bone-implant bonding with signs of active remodelling of bone and the HA coating were demonstrated by histology and SEM. No loose BONIT-HA particles or delamination of the coating were observed, and there was no inflammation or fibrous interposition at the interface. Histomorphometry showed bone-implant contact varying between 26.5% at three weeks and 83.5% at 13 months at the HA-coated implant surface. The bone density in the area of investigation was between 24.6% at three weeks and 41.1% at 32 months. The DOTIZE surface treatment of the distal part of the stem completely prevented tissue and bone apposition in all cases, thereby optimising proximal stress transfer. The overall features of this implant, in terms of geometry and surface texture, suggest a mechanically stable design with a highly active biomimetic coating, resulting in rapid and extensive osseo-integration, exclusively in the metaphyseal part of the stem. Early remodelling of the HA coating does not seem to have a detrimental effect on short-term bone-implant coupling. There were no adverse effects identified from either the BONIT-HA coating or the DOTIZE surface treatment


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1259 - 1264
1 Dec 2023
Hurley ET Hughes AJ Savage-Elliott I Dejour D Campbell KA Mulcahey MK Wittstein JR Jazrawi LM

Aims

The aim of this study was to establish consensus statements on the diagnosis, nonoperative management, and indications, if any, for medial patellofemoral complex (MPFC) repair in patients with patellar instability, using the modified Delphi approach.

Methods

A total of 60 surgeons from 11 countries were invited to develop consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest within patellar instability. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered to be unanimous.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1125 - 1132
1 Oct 2024
Luengo-Alonso G Valencia M Martinez-Catalan N Delgado C Calvo E

Aims

The prevalence of osteoarthritis (OA) associated with instability of the shoulder ranges between 4% and 60%. Articular cartilage is, however, routinely assessed in these patients using radiographs or scans (2D or 3D), with little opportunity to record early signs of cartilage damage. The aim of this study was to assess the prevalence and localization of chondral lesions and synovial damage in patients undergoing arthroscopic surgery for instablility of the shoulder, in order to classify them and to identify risk factors for the development of glenohumeral OA.

Methods

A total of 140 shoulders in 140 patients with a mean age of 28.5 years (15 to 55), who underwent arthroscopic treatment for recurrent glenohumeral instability, were included. The prevalence and distribution of chondral lesions and synovial damage were analyzed and graded into stages according to the division of the humeral head and glenoid into quadrants. The following factors that might affect the prevalence and severity of chondral damage were recorded: sex, dominance, age, age at the time of the first dislocation, number of dislocations, time between the first dislocation and surgery, preoperative sporting activity, Beighton score, type of instability, and joint laxity.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims

The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process.

Methods

This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 574 - 578
1 May 2008
Carroll FA Hoad-Reddick DA Kerry RM Stockley I

Between 1980 and 2000, 63 support rings were used in the management of acetabular deficiency in a series of 60 patients, with a mean follow-up of 8.75 years (2 months to 23.8 years). There was a minimum five-year follow-up for successful reconstructions. The indication for revision surgery was aseptic loosening in 30 cases and infection in 33. All cases were Paprosky III defects; IIIA in 33 patients (52.4%) and IIIB in 30 (47.6%), including four with pelvic dissociation. A total of 26 patients (43.3%) have died since surgery, and 34 (56.7%) remain under clinical review. With acetabular revision for infection or aseptic loosening as the definition of failure, we report success in 53 (84%) of the reconstructions. A total of 12 failures (19%) required further surgery, four (6.3%) for aseptic loosening of the acetabular construct, six (9.5%) for recurrent infection and two (3.2%) for recurrent dislocation requiring captive components. Complications, seen in 11 patients (18.3%), included six femoral or sciatic neuropraxias which all resolved, one grade III heterotopic ossification, one on-table acetabular revision for instability, and three early post-operative dislocations managed by manipulation under anaesthesia, with no further instability. We recommend support rings and morcellised bone graft for significant acetabular bone deficiency that cannot be reconstructed using mesh


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1180 - 1188
1 Oct 2022
Qu H Mou H Wang K Tao H Huang X Yan X Lin N Ye Z

Aims

Dislocation of the hip remains a major complication after periacetabular tumour resection and endoprosthetic reconstruction. The position of the acetabular component is an important modifiable factor for surgeons in determining the risk of postoperative dislocation. We investigated the significance of horizontal, vertical, and sagittal displacement of the hip centre of rotation (COR) on postoperative dislocation using a CT-based 3D model, as well as other potential risk factors for dislocation.

Methods

A total of 122 patients who underwent reconstruction following resection of periacetabular tumour between January 2011 and January 2020 were studied. The risk factors for dislocation were investigated with univariate and multivariate logistic regression analysis on patient-specific, resection-specific, and reconstruction-specific variables.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1306 - 1311
1 Sep 2010
Patten EW Atwood SA Van Citters DW Jewett BA Pruitt LA Ries MD

Retrieval studies of total hip replacements with highly cross-linked ultra-high-molecular-weight polyethylene liners have shown much less surface damage than with conventional ultra-high-molecular-weight polyethylene liners. A recent revision hip replacement for recurrent dislocation undertaken after only five months revealed a highly cross-linked polyethylene liner with a large area of visible delamination. In order to determine the cause of this unusual surface damage, we analysed the bearing surfaces of the cobalt-chromium femoral head and the acetabular liner with scanning electron microscopy, energy dispersive x-ray spectroscopy and optical profilometry. We concluded that the cobalt-chromium modular femoral head had scraped against the titanium acetabular shell during the course of the dislocations and had not only roughened the surface of the femoral head but also transferred deposits of titanium onto it. The largest deposits were 1.6 μm to 4.3 μm proud of the surrounding surface and could lead to increased stresses in the acetabular liner and therefore cause accelerated wear and damage. This case illustrates that dislocations can leave titanium deposits on cobalt-chromium femoral heads and that highly cross-linked ultra-high-molecular-weight polyethylene remains susceptible to surface damage


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 814 - 818
1 Jun 2005
Ince A Seemann K Frommelt L Katzer A Loehr JF

There are few reports in the literature of the diagnosis and treatment of the infected shoulder arthroplasty. Most deal with resection arthroplasty and two-stage exchange surgery. We present our results of one-stage exchange operation as treatment for the infected shoulder arthroplasty. Our group comprised 16 patients (ten men, six women) with 16 infected arthroplasties. By the time of follow-up, two patients had died (mean 5.8 years), two could not be located and three had already undergone revision surgery. Nine patients were thus available for clinical examination and assessment. The infections were largely caused by staphylococci, Propionibacterium species and streptococci. Two were early infections (within three months of surgery) and 14 were late infections. The mean follow-up was 5.8 years (13 months to 13.25 years) when the mean Constant-Murley score was 33.6 points and the mean University College of Los Angeles score 18.3 points. Further revision was performed in three patients. One sustained a peri-prosthetic humeral fracture, another developed an acromial pseudarthrosis after transacromial surgery and the third suffered recurrent dislocations. No patient had a recurrence of infection. A one-stage exchange procedure using antibiotic-loaded bone cement eradicated infection in all our patients and we suggest that such a procedure is at least as successful as either a resection arthroplasty or a two-stage exchange in the management of the infected shoulder arthroplasty


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 844 - 851
1 Jul 2022
Rogmark C Nåtman J Jobory A Hailer NP Cnudde P

Aims

Patients with femoral neck fractures (FNFs) treated with total hip arthroplasty (THA) have an almost ten-fold increased risk of dislocation compared to patients undergoing elective THA. The surgical approach influences the risk of dislocation. To date, the influence of differing head sizes and dual-mobility components (DMCs) on the risk of dislocation has not been well studied.

Methods

In an observational cohort study on 8,031 FNF patients with THA between January 2005 and December 2014, Swedish Arthroplasty Register data were linked with the National Patient Register, recording the total dislocation rates at one year and revision rates at three years after surgery. The cumulative incidence of events was estimated using the Kaplan-Meier method. Cox multivariable regression models were fitted to calculate adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) for the risk of dislocation, revision, or mortality, stratified by surgical approach.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1464 - 1473
1 Nov 2013
Vendittoli P Rivière C Roy AG Barry J Lusignan D Lavigne M

A total of 219 hips in 192 patients aged between 18 and 65 years were randomised to 28-mm metal-on-metal uncemented total hip replacements (THRs, 107 hips) or hybrid hip resurfacing (HR, 112 hips). At a mean follow-up of eight years (6.6 to 9.3) there was no significant difference between the THR and HR groups regarding rate of revision (4.0% (4 of 99) vs 5.8% (6 of 104), p = 0.569) or re-operation rates without revision (5.1% (5 of 99) vs 2.9% (3 of 104), p = 0.428). In the THR group one recurrent dislocation, two late deep infections and one peri-prosthetic fracture required revision, whereas in the HR group five patients underwent revision for femoral head loosening and one for adverse reaction to metal debris. The mean University of California, Los Angeles activity scores were significantly higher in HR (7.5 (. sd. 1.7) vs 6.9 (. sd. 1.7), p = 0.035), but similar mean Western Ontario and McMaster Universities Osteoarthritis Index scores were obtained (5.8 (. sd. 9.5) in HR vs 5.1 (. sd. 8.9) in THR, p = 0.615) at the last follow-up. Osteolysis was found in 30 of 81 THR patients (37.4%), mostly in the proximal femur, compared with two of 83 HR patients (2.4%) (p < 0.001). At five years the mean metal ion levels were < 2.5 μg/l for cobalt and chromium in both groups; only titanium was significantly higher in the HR group (p = 0.001). Although revision rates and functional scores were similar in both groups at mid-term, long-term survival analysis is necessary to determine whether one procedure is more advantageous than the other. Cite this article: Bone Joint J 2013;95-B:1464–73


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 170 - 175
1 Feb 2009
Young L Duckett S Dunn A

We describe the survivorship of the Exeter femoral component in a District General Hospital. Between 1994 and 1996, 230 Exeter Universal cemented femoral components were implanted in 215 patients who were reviewed at a mean of 11.2 years (10 to 13). We used one acetabular implant, the Elite Ogee component, in 218 of the 230 hips. During the period of this study 76 patients (79 hips) died. Of the remaining 139 patients (151 hips), 121 were able to attend for radiological analysis at a minimum of ten years. One patient was lost to follow-up. No femoral component was revised for aseptic loosening. Three hips were revised for deep infection and six acetabular components required revision, four for loosening and two for recurrent dislocation. Taking the ‘worst-case scenario’ including the one patient lost to follow-up, the overall survival rate was 94.4% at 13 years. Our results confirm excellent medium-term results for the Exeter Universal femoral component, implanted in a general setting. The excellent survival of this femoral component, when used in combination with the Ogee acetabular component, suggests that this is a successful pairing


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1061 - 1067
1 Aug 2005
Raman R Kamath RP Parikh A Angus PD

We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d’Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6°. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 38 - 43
1 Mar 2024
Buckner BC Urban ND Cahoy KM Lyden ER Deans CF Garvin KL

Aims

Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE.

Methods

From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years’ follow-up.