Advertisement for orthosearch.org.uk
Results 1 - 100 of 3420
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 688 - 695
1 Jul 2024
Farrow L Zhong M Anderson L

Aims. To examine whether natural language processing (NLP) using a clinically based large language model (LLM) could be used to predict patient selection for total hip or total knee arthroplasty (THA/TKA) from routinely available free-text radiology reports. Methods. Data pre-processing and analyses were conducted according to the Artificial intelligence to Revolutionize the patient Care pathway in Hip and knEe aRthroplastY (ARCHERY) project protocol. This included use of de-identified Scottish regional clinical data of patients referred for consideration of THA/TKA, held in a secure data environment designed for artificial intelligence (AI) inference. Only preoperative radiology reports were included. NLP algorithms were based on the freely available GatorTron model, a LLM trained on over 82 billion words of de-identified clinical text. Two inference tasks were performed: assessment after model-fine tuning (50 Epochs and three cycles of k-fold cross validation), and external validation. Results. For THA, there were 5,558 patient radiology reports included, of which 4,137 were used for model training and testing, and 1,421 for external validation. Following training, model performance demonstrated average (mean across three folds) accuracy, F1 score, and area under the receiver operating curve (AUROC) values of 0.850 (95% confidence interval (CI) 0.833 to 0.867), 0.813 (95% CI 0.785 to 0.841), and 0.847 (95% CI 0.822 to 0.872), respectively. For TKA, 7,457 patient radiology reports were included, with 3,478 used for model training and testing, and 3,152 for external validation. Performance metrics included accuracy, F1 score, and AUROC values of 0.757 (95% CI 0.702 to 0.811), 0.543 (95% CI 0.479 to 0.607), and 0.717 (95% CI 0.657 to 0.778) respectively. There was a notable deterioration in performance on external validation in both cohorts. Conclusion. The use of routinely available preoperative radiology reports provides promising potential to help screen suitable candidates for THA, but not for TKA. The external validation results demonstrate the importance of further model testing and training when confronted with new clinical cohorts. Cite this article: Bone Joint J 2024;106-B(7):688–695


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims. To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods. We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results. The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion. There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant. Cite this article: Bone Joint J 2024;106-B(4):359–364


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1202 - 1208
1 Nov 2022
Klasan A Rice DA Kluger MT Borotkanics R McNair PJ Lewis GN Young SW

Aims. Despite new technologies for total knee arthroplasty (TKA), approximately 20% of patients are dissatisfied. A major reason for dissatisfaction and revision surgery after TKA is persistent pain. The radiological grade of osteoarthritis (OA) preoperatively has been investigated as a predictor of the outcome after TKA, with conflicting results. The aim of this study was to determine if there is a difference in the intensity of pain 12 months after TKA in relation to the preoperative radiological grade of OA alone, and the combination of the intensity of preoperative pain and radiological grade of OA. Methods. The preoperative data of 300 patients who underwent primary TKA were collected, including clinical information (age, sex, preoperative pain), psychological variables (depression, anxiety, pain catastrophizing, anticipated pain), and quantitative sensory testing (temporal summation, pressure pain thresholds, conditioned pain modulation). The preoperative radiological severity of OA was graded according to the Kellgren-Lawrence (KL) classification. Persistent pain in the knee was recorded 12 months postoperatively. Generalized linear models explored differences in postoperative pain according to the KL grade, and combined preoperative pain and KL grade. Relative risk models explored which preoperative variables were associated with the high preoperative pain/low KL grade group. Results. Pain 12 months after TKA was not associated with the preoperative KL grade alone. Significantly increased pain 12 months after TKA was found in patients with a combination of high preoperative pain and a low KL grade (p = 0.012). Patients in this group were significantly more likely to be male, younger, and have higher preoperative pain catastrophizing, higher depression, and lower anxiety (all p ≤ 0.05). Conclusion. Combined high preoperative pain and low radiological grade of OA, but not the radiological grade alone, was associated with a higher intensity of pain 12 months after primary TKA. This group may have a more complex cause of pain that requires additional psychological interventions in order to optimize the outcome of TKA. Cite this article: Bone Joint J 2022;104-B(11):1202–1208


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims. The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results. Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion. These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids. Cite this article: Bone Joint J 2023;105-B(6):668–678


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant removal compared to 1/91 segment (1%) in the PRECICE cohort. In the STRYDE cohort, osteolysis initially increased, but decreased or resolved in almost all lengthened segments (86%) after implant removal. Implant failure was observed in 9/48 STRYDE (19%) and in 8/92 PRECICE nails (9%). Breakage of the distal locking bolts was found in 5/48 STRYDE nails (10%) compared to none in the PRECICE cohort. Treatment-associated pain was generally recorded as mild and found in 30/48 patients (63%) and 39/92 (42%) in the STRYDE and PRECICE cohorts, respectively. Temporary range of motion (ROM) limitations under distraction were registered in 17/48 (35%) segments treated with the STRYDE and 35/92 segments (38%) treated with the PRECICE nail. Conclusion. Osteolysis and periosteal reaction, implant breakage, and pain during lengthening and consolidation is more likely in patients treated with the STRYDE nail compared to the PRECICE nail. Temporary ROM limitations during lengthening occurred independent of the applied device. Implant-related osseous alterations seem to remodel after implant removal. Cite this article: Bone Joint J 2023;105-B(1):88–96


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 87 - 97
1 Jan 2021
Burssens A De Roos D Barg A Welck MJ Krähenbühl N Saltzman CL Victor J

Aims. Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity. Methods. A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant extra-articular osteotomy and case reports or expert opinions. An assessment of quality was conducted using the modified Methodological Index for Non-Randomized Studies (MINORS). The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and registered in the PROSPERO database (CRD42019106980). Results. A total of 17 studies were found to be eligible for review. They included six prospective and ten retrospective studies, and one case-control study. The effects of TKA showed a clinical improvement in the hindfoot deformity in three studies, but did not if there was osteoarthritis (OA) of the ankle (one study) or a persistent deformity of the knee (one study). The radiological alignment of the hindfoot corrected in 11 studies, but did not in the presence of a rigid hindfoot varus deformity (in two studies). The effects of a hindfoot deformity on TKA included a clinical association with instability of the knee in one study, and a shift in the radiological weightbearing axis in two studies. The mean MINORS score was 9.4 out of 16 (7 to 12). Conclusion. TKA improves both the function and alignment of the hindfoot in patients with a preoperative deformity of the hindfoot. This may not apply if there is a persistent deformity of the knee, a rigid hindfoot varus deformity, or OA of the ankle. Moreover, a persistent deformity of the hindfoot may adversely affect the stability and longevity of a TKA. These findings should be interpreted with caution due to the moderate methodological quality of the studies which were included. Therefore, further prospective studies are needed in order to determine at which stage correction of a hindfoot deformity is required to optimize the outcome of a TKA. Cite this article: Bone Joint J 2021;103-B(1):87–97


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 40 - 46
1 May 2024
Massè A Giachino M Audisio A Donis A Giai Via R Secco DC Limone B Turchetto L Aprato A

Aims. Ganz’s studies made it possible to address joint deformities on both the femoral and acetabular side brought about by Perthes’ disease. Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency, along with periacetabular osteotomy (PAO), which may enhance coverage and containment. The purpose of this study is to show the clinical and morphological outcomes of the technique and the use of an implemented planning approach. Methods. From September 2015 to December 2021, 13 FHROs were performed on 11 patients for Perthes’ disease in two centres. Of these, 11 hips had an associated PAO. A specific CT- and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiological parameters (sphericity index, extrusion index, integrity of the Shenton’s line, lateral centre-edge angle (LCEA), Tönnis angle), and clinical parameters (range of motion, visual analogue scale (VAS) for pain, Merle d'Aubigné-Postel score, modified Harris Hip Score (mHHS), and EuroQol five-dimension five-level health questionnaire (EQ-5D-5L)). Early and late complications were reported. Results. The mean follow-up was 39.7 months (standard deviation (SD) 26.4). The mean age at surgery was 11.4 years (SD 1.6). No major complications were recorded. One patient required a total hip arthroplasty. Mean femoral head sphericity increased from 46.8% (SD 9.34%) to 70.2% (SD 15.44; p < 0.001); mean LCEA from 19.2° (SD 9.03°) to 44° (SD 10.27°; p < 0.001); mean extrusion index from 37.8 (SD 8.70) to 7.5 (SD 9.28; p < 0.001); and mean Tönnis angle from 16.5° (SD 12.35°) to 4.8° (SD 4.05°; p = 0.100). The mean VAS improved from 3.55 (SD 3.05) to 1.22 (1.72; p = 0.06); mean Merle d’Aubigné-Postel score from 14.55 (SD 1.74) to 16 (SD 1.6; p = 0.01); and mean mHHS from 60.6 (SD 18.06) to 81 (SD 6.63; p = 0.021). The EQ-5D-5L also showed significant improvements. Conclusion. FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical, and morphological outcomes in Perthes’ disease. The newly introduced simulation and planning algorithm may help to further refine the technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):40–46


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1815 - 1820
1 Dec 2021
Huhnstock S Wiig O Merckoll E Svenningsen S Terjesen T

Aims. The aim of this study was to assess the prognostic value of the modified three-group Stulberg classification, which is based on the sphericity of the femoral head, in patients with Perthes’ disease. Methods. A total of 88 patients were followed from the time of diagnosis until a mean follow-up of 21 years. Anteroposterior pelvic and frog-leg lateral radiographs were obtained at diagnosis and at follow-up of one, five, and 21 years. At the five- and 21-year follow-up, the femoral heads were classified using a modified three-group Stulberg classification (round, ovoid, or flat femoral head). Further radiological endpoints at long-term follow-up were osteoarthritis (OA) of the hip and the requirement for total hip arthroplasty (THA). Results. There were 71 males (81%) and 17 females. A total of 13 patients had bilateral Perthes’ disease; thus 101 hips were analyzed. At five-year follow-up, 37 hips were round, 38 ovoid, and 26 flat. At that time, 66 hips (65%) were healed and 91 (90%) were skeletally immature. At long-term follow-up, when the mean age of the patients was 28 years (24 to 34), 20 hips had an unsatisfactory outcome (seven had OA and 13 had required THA). There was a strongly significant association between the modified Stulberg classification applied atfive-year follow-up and an unsatisfactory outcome at long-term follow-up (p < 0.001). Between the five- and 21-year follow-up, 67 hips (76%) stayed in their respective modified Stulberg group, indicating a strongly significant association between the Stulberg classifications at these follow-ups (p < 0.001). Conclusion. The modified Stulberg classification is a strong predictor of long-term radiological outcome in patients with Perthes’ disease. It can be applied at the healing stage, which is usually reached five years after the diagnosis is made and before skeletal maturity. Cite this article: Bone Joint J 2021;103-B(12):1815–1820


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1309 - 1316
1 Jul 2021
Garg B Bansal T Mehta N

Aims. To describe the clinical, radiological, and functional outcomes in patients with isolated congenital thoracolumbar kyphosis who were treated with three-column osteotomy by posterior-only approach. Methods. Hospital records of 27 patients with isolated congenital thoracolumbar kyphosis undergoing surgery at a single centre were retrospectively analyzed. All patients underwent deformity correction which involved a three-column osteotomy by single-stage posterior-only approach. Radiological parameters (local kyphosis angle (KA), thoracic kyphosis (TK), lumbar lordosis (LL), pelvic tilt (PT), sacral slope (SS), C7 sagittal vertical axis (C7 SVA), T1 slope, and pelvic incidence minus lumbar lordosis (PI-LL)), functional scores, and clinical details of complications were recorded. Results. The mean age of the study population was 13.9 years (SD 6.4). The apex of deformity was in thoracic, thoracolumbar, and lumbar spine in five, 14, and eight patients, respectively. The mean operating time was 178.4 minutes (SD 38.5) and the mean operative blood loss was 701.8 ml (SD 194.4). KA (preoperative mean 70.8° (SD 21.6°) vs final follow-up mean 24.7° (SD 18.9°); p < 0.001) and TK (preoperative mean -1.48° (SD 41.23°) vs final follow-up mean 24.28° (SD 17.29°); p = 0.005) underwent a significant change with surgery. Mean Scoliosis Research Society (SRS-22r) score improved after surgical correction (preoperative mean 3.24 (SD 0.37) vs final follow-up mean 4.28 (SD 0.47); p < 0.001) with maximum improvement in self-image and mental health domains. The overall complication rate was 26%, including two neurological and five non-neurological complications. Permanent neurological deficit was noted in one patient. Conclusion. Deformity correction employing three-column osteotomies by a single-stage posterior-only approach is safe and effective in treating isolated congenital thoracolumbar kyphosis. Cite this article: Bone Joint J 2021;103-B(7):1309–1316


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1307 - 1312
1 Oct 2019
Jacxsens M Schmid J Zdravkovic V Jost B Spross C

Aims. In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Patients and Methods. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up. Results. In 100 patients (59 female, 41 male; mean age 57 years), 91 of the fractures (91%) remained stable. In five of nine patients (55%) with secondary displacement, surgery was recommended. Comminution, present in 23 patients (23%), was identified as a predictor of secondary displacement (p < 0.001). Patients’ age, sex, fracture configuration, and bone quality were not associated with secondary displacement (p ≥ 0.438). Nonoperative treatment resulted in a mean absolute Constant score (CS) of 80 (49 to 98), relative CS of 101% (63% to 138%), median subjective shoulder value of 95% (interquartile range (IQR) 90% to 100%), and median EuroQol five-dimensional questionnaire score of 0.89 (IQR 0.80 to 1.00) with bone union in all cases at one-year follow-up. Conclusion. Radiological re-evaluation was only necessary in patients presenting with comminution and may be redundant for 77% of patients with one-part proximal humerus fractures. Nonoperative treatment of one-part proximal humerus fractures remains the mainstay of treatment with a low rate of secondary surgery, a high union rate, and good clinical results. Cite this article: Bone Joint J 2019;101-B:1307–1312


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims. To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes. Methods. A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups. Results. There were ten and 25 defects in the femur and tibia, respectively. Median LEFS improved significantly from 8 (IQR 1.5 to 19.3) preoperatively to 63.5 (IQR 57 to 73.3) at final follow-up (p < 0.001). Bone healing was achieved in all limbs, and median time from the second stage to bone healing was six months (IQR 5 to 10). Median time to bone healing, preoperative LEFS, or postoperative LEFS did not differ significantly between the defect size groups or among the treatment groups. Conclusion. IMT using β-TCP provided satisfactory clinical and radiological outcomes for segmental bone defects in the lower limbs; surgical outcomes were not influenced by bone defect size or operated part. Cite this article: Bone Joint J 2021;103-B(3):456–461


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 301 - 309
1 Mar 2020
Keenan OJF Holland G Maempel JF Keating JF Scott CEH

Aims. Although knee osteoarthritis (OA) is diagnosed and monitored radiologically, actual full-thickness cartilage loss (FTCL) has rarely been correlated with radiological classification. This study aims to analyze which classification system correlates best with FTCL and to assess their reliability. Methods. A prospective study of 300 consecutive patients undergoing unilateral total knee arthroplasty (TKA) for OA (mean age 69 years (44 to 91; standard deviation (SD) 9.5), 178 (59%) female). Two blinded examiners independently graded preoperative radiographs using five common systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlbäck. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC). Intraoperatively, anterior cruciate ligament (ACL) status and the presence of FTCL in 16 regions of interest were recorded. Radiological classification and FTCL were correlated using the Spearman correlation coefficient. Results. Knees had a mean of 6.8 regions of FTCL (SD 3.1), most common medially. The commonest patterns of FTCL were medial ± patellofemoral (143/300, 48%) and tricompartmental (89/300, 30%). ACL status was associated with pattern of FTCL (p = 0.023). All radiological classification systems demonstrated moderate ICC, but this was highest for the IKDC: whole knee 0.68 (95% confidence interval (CI) 0.60 to 0.74); medial compartment 0.84 (95% CI 0.80 to 0.87); and lateral compartment 0.79 (95% CI 0.73 to 0.83). Correlation with actual FTCL was strongest for Ahlbäck (Spearman rho 0.27 to 0.39) and KL (0.30 to 0.33) systems, although all systems demonstrated medium correlation. The Ahlbäck score was the most discriminating in severe knee OA. Osteophyte presence in the medial compartment had high positive predictive value (PPV) for FTCL, but not in the lateral compartment. Conclusion. The Ahlbäck and KL systems had the highest correlation with confirmed cartilage loss at TKA. However, the IKDC system displayed the best interobserver reliability, with favourable correlation with FTCL in medial and lateral compartments, although it was less discriminating in more severe disease. Cite this article: Bone Joint J 2020;102-B(3):301–309


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims. Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). Patients and Methods. A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m. 2. (17.3 to 66.4). Results. Greater tuberosity stress shielding was noted in 14 shoulders (two TSA and 12 RSA) and was graded as mild in nine, moderate in two, and severe in three. Medial calcar resorption was noted in 23 shoulders (seven TSA and 16 RSA), and was graded as mild in 21 and moderate in two. No humeral components were revised for loosening or considered to be loose radiologically. Nine shoulders underwent reoperation for infection (n = 3), fracture of the humeral tray (n = 2), aseptic glenoid loosening (n = 1), and instability (n = 3). No periprosthetic fractures occurred. Conclusion. Implantation of this particular short cementless humeral component at the time of TSA or RSA was associated with a low rate of adverse radiological findings on the humeral side at mid-term follow-up. Our data do not raise any concerns regarding the use of a short stem in TSA or RSA. Cite this article: Bone Joint J 2019;101-B:610–614


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 808 - 814
1 Jul 2023
Gundavda MK Lazarides AL Burke ZDC Focaccia M Griffin AM Tsoi KM Ferguson PC Wunder JS

Aims

The preoperative grading of chondrosarcomas of bone that accurately predicts surgical management is difficult for surgeons, radiologists, and pathologists. There are often discrepancies in grade between the initial biopsy and the final histology. Recent advances in the use of imaging methods have shown promise in the ability to predict the final grade. The most important clinical distinction is between grade 1 chondrosarcomas, which are amenable to curettage, and resection-grade chondrosarcomas (grade 2 and 3) which require en bloc resection. The aim of this study was to evaluate the use of a Radiological Aggressiveness Score (RAS) to predict the grade of primary chondrosarcomas in long bones and thus to guide management.

Methods

A total of 113 patients with a primary chondrosarcoma of a long bone presenting between January 2001 and December 2021 were identified on retrospective review of a single oncology centre’s prospectively collected database. The nine-parameter RAS included variables from radiographs and MRI scans. The best cut-off of parameters to predict the final grade of chondrosarcoma after resection was determined using a receiver operating characteristic curve (ROC), and this was correlated with the biopsy grade.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 483 - 489
1 Apr 2016
Tigchelaar S Rooy JD Hannink G Koëter S van Kampen A Bongers E

Aim. Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral dysfunction as a key symptom. We present the first in-depth radiological evaluation of the knee in a large series of NPS patients and describe the typical malformations. Patients and Methods. Conventional radiological examination of 95 skeletally mature patients with NPS was performed. Patellar morphology was classified according to the Wiberg classification as modified by Baumgartl and Ficat criteria, and trochlear shape was classified according to the Dejour classification. Results. Patellar aplasia was present in 4/90 (4%), and patellar hypoplasia in 77/90 (86%) of patients. The prevailing patellar shapes were type III, type IV and Hunter’s cap. No patellar shape genotype-phenotype association could be found. The malformations of the distal femur comprised shortening of the lateral femoral condyle in 46 out of 84 patients (55%), with a prominent anterior surface of the lateral femoral condyle in 47 out of 84 patients (56%) and a flat anterior surface of the medial femoral condyle in 78 out of 85 patients (92%). The trochlea was type A1 according to the Dejour classification in 79 out of 85 patients (93%). . Conclusion. An easily recognisable characteristic quartet of malformations consisting of patellar aplasiaor hypoplasia and the malformations of the distal femur was found in 22 out of 81 patients (27%), with the majority displaying at least three malformations. Take home message: The distinct malformations of the knee in nail patella syndrome are easily recognisable on conventional radiographs and lead to the correct interpretation of the aberrant morphology which is essential in the treatment of these patellofemoral disorders. Cite this article: Bone Joint J 2016;98-B:483–9


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 376 - 382
1 Mar 2017
Plant CE Parsons NR Costa ML

Aims. We conducted a study to determine whether radiological parameters correlate with patient reported functional outcome, health-related quality of life and physical measures of function in patients with a fracture of the distal radius. Patients and Methods. The post-operative palmar tilt and ulnar variance at six weeks and 12 months were correlated with the Patient Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand, and EuroQol scores, grip strength, pinch strength and range of movement at three, six and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical fixation, with either percutaneous pinning or reconstruction with a volar plate, for a fracture of the distal radius. Results. Radiological parameters were found to correlate poorly with the patient reported outcomes (r = 0.00 to 0.47) and physical measures of function (r = 0.01 to 0.51) at all intervals. Conclusion. This study raises concerns about the use of radiological parameters to determine management, and to act as a surrogates for successful treatment, in patients with a fracture of the distal radius. Restoration of ‘normal’ radiographic parameters may not be necessary to achieve a satisfactory functional outcome for the patient. Cite this article: Bone Joint J 2017;99-B:376–82


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 459 - 462
1 Apr 2009
Heinert G Hendricks J Loeffler MD

Digital templating in hip replacement is commonly performed with radiological markers to determine the magnification. The latter can also be determined by measuring the distance from the x-ray focal spot to the object and the distance from the x-ray focal spot to the radiological cassette or image receptor. We used post-operative radiographs of total hip replacements and hemiarthroplasties from 22 patients to calculate the magnification using both methods. The accuracy of each method was ascertained by measuring the size of the head of the implant projected on to the radiographs and comparing the result with the known size recorded in the medical records. The accuracy was found to be similar with a mean absolute measurement error of 2.6% (. sd. 1.4; 0.0% to 5.2%) for the radiological marker and 2.8% (. sd. 2.2; 0.4% to 10.1%) for the distance method (p = 0.75). The mean radiation dose for templating radiographs (pelvis and lateral of the hip) was similar when taken using a radiological marker (328 mSv . sd. 142) (n = 51) or using the distance measurement method (324 mSv . sd. 39) (n = 39) (p = 0.90). We conclude that the distance measuring method is as accurate as the radiological marker method, but may avoid some of the disadvantages such as misplacement of the marker or placement outside the radiological field. It may also be more acceptable to the patient and radiographer


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 950 - 956
1 Jul 2015
Tsitsilonis S Schaser KD Wichlas F Haas NP Manegold S

The incidence of periprosthetic fractures of the ankle is increasing. However, little is known about the outcome of treatment and their management remains controversial. The aim of this study was to assess the impact of periprosthetic fractures on the functional and radiological outcome of patients with a total ankle arthroplasty (TAA). A total of 505 TAAs (488 patients) who underwent TAA were retrospectively evaluated for periprosthetic ankle fracture: these were then classified according to a recent classification which is orientated towards treatment. The outcome was evaluated clinically using the American Orthopedic Foot and Ankle Society (AOFAS) score and a visual analogue scale for pain, and radiologically. . A total of 21 patients with a periprosthetic fracture of the ankle were identified. There were 13 women and eight men. The mean age of the patients was 63 years (48 to 74). Thus, the incidence of fracture was 4.17%. . There were 11 intra-operative and ten post-operative fractures, of which eight were stress fractures and two were traumatic. The prosthesis was stable in all patients. Five stress fractures were treated conservatively and the remaining three were treated operatively. . A total of 17 patients (81%) were examined clinically and radiologically at a mean follow-up of 53.5 months (12 to 112). The mean AOFAS score at follow-up was 79.5 (21 to 100). The mean AOFAS score in those with an intra-operative fracture was 87.6 (80 to 100) and for those with a stress fracture, which were mainly because of varus malpositioning, was 67.3 (21 to 93). Periprosthetic fractures of the ankle do not necessarily adversely affect the clinical outcome, provided that a treatment algorithm is implemented with the help of a new classification system. . Cite this article: Bone Joint J 2015;97-B:950–6


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 720 - 724
1 Jun 2009
Ollivere B Darrah C Brankin RC Donnell ST Walton NP

We report the follow-up at 12 years of the use of the Elite Plus total hip replacement (THR). We have previously reported the results at a mean of 6.4 years. Of the 217 patients (234 THRs), 83 had died and nine had been lost to follow-up. The patients were reviewed radiologically and clinically using the Oxford hip score. Of the 234 THRs, 19 (8.1%) had required a revision by the final follow-up in all but one for aseptic loosening. Survivorship analysis for revision showed a survival of 93.9% (95% confidence interval (CI) 89.2 to 96.5) at ten years, and of 88.0% (95% CI 81.8 to 92.3) at 12 years. At the final follow-up survival analysis showed that 37% (95% CI 37.3 to 44.7) of the prostheses had either failed radiologically or had been revised. Patients with a radiologically loose femoral component had a significantly poorer Oxford hip score than those with a well-fixed component (p = 0.03). Radiological loosening at 6.4 years was predictive of failure at 12 years. Medium-term radiographs and clinical scores should be included in the surveillance of THR to give an early indication of the performance of specific implants


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 72 - 76
1 Jan 2007
Patel V Day A Dinah F Kelly M Bircher M

Specific radiological features identified by Brandser and Marsh were selected for the analysis of acetabular fractures according to the classification of Letournel and Judet. The method employs a binary approach that requires the observer to allocate each radiological feature to one of two groups. The inter- and intra-observer variances were assessed. The presence of articular displacement, marginal impaction, incongruity, intra-articular fragments and osteochondral injuries to the femoral head were analysed by a similar method. These factors were termed ‘modifiers’ and are generally considered when planning operative intervention and, critically, they may influence prognosis. Six observers independently assessed 30 sets of plain radiographs and CT scans on two separate occasions, 12 weeks apart. They were asked to determine the presence or absence of specific radiological features. This simple binary approach to classification yields an inter- and intra-observer agreement which ranges from moderate to near-perfect (κ = 0.49 to 0.88 and κ = 0.57 to 0.88, respectively). A similar approach to the modifiers yields only slight to fair inter-observer agreement (κ = 0.20 to 0.34) and slight to moderate intra-observer agreement (κ = 0 to 0.55)


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1324 - 1328
1 Oct 2007
Chang CB Han I Kim SJ Seong SC Kim TK

We investigated the association between the radiological findings and the symptoms arising from the patellofemoral joint in advanced osteoarthritis (OA) of the knee. Four radiological features, joint space narrowing, osteophyte formation, translation of the patella and focal attrition were assessed in 151 consecutive osteoarthritic knees in 107 patients undergoing total knee replacement. The symptoms which were assessed included anterior knee pain which was scored, the ability to rise from a chair and climb stairs, and quadriceps weakness. Among the radiological features, only patellar translation and obliteration of the joint space had a statistically significant association with anterior knee pain (odds ratio (OR) 4.85; 95% confidence interval (CI) 1.83 to 12.88 and OR 11.23; 95% CI 2.44 to 51.62) respectively. Patellar translation had a statistically significant association with difficulty in rising from a chair (OR 9.06; 95% CI 1.75 to 45.11). Other radiological features, including osteophytes, joint space narrowing, and focal attrition had no significant association. Our study indicates that the radiological findings of patellar translation and significant loss of cartilage are predictive of patellofemoral symptoms and functional limitation in advanced OA of the knee


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 596 - 602
1 May 2018
Bock P Pittermann M Chraim M Rois S

Aims. Various radiological parameters are used to evaluate a flatfoot deformity and their measurements may differ. The aims of this study were to answer the following questions: 1) Which of the 11 parameters have the best inter- and intraobserver reliability in a standardized radiological setting? 2) Are pre- and postoperative assessments equally reliable? 3) What are the identifiable sources of variation?. Patients and Methods. Measurements of the 11 parameters were recorded on anteroposterior and lateral weight-bearing radiographs of 38 feet before and after surgery for flatfoot, by three observers with different experience in foot surgery (A, ten years; B, three years; C, third-year orthopaedic resident). The inter- and intraobserver reliability was calculated. Results. Preoperative interobserver reliability was high for four, moderate for five, and low for two parameters. Postoperative interobserver reliability was high for four, moderate for five, and low for two parameters. Intraobserver reliability was excellent for all parameters preoperatively as recorded by observer A (PB) and B (MP), and for eight parameters as recorded by observer C (SR). Intraobserver reliability was excellent for ten parameters postoperatively as recorded by observer A and B, and for eight parameters as recorded by observer C. Conclusion. The following parameters can be recommended. For preoperative and postoperative evaluation of flatfoot: anteroposterior, talonavicular coverage angle; lateral, talometatarsal I angle, calcaneal pitch angle, and cuneiform-medial height (high interobserver reliability); and anteroposterior, talometatarsal II angle; lateral, talocalcaneal angle,tibiocalcaneal angle (moderate interobserver reliability). For more experienced observers, we also recommend the anteroposterior talometatarsal I angle (moderate reliability). The inter- and intraobserver reliability for most parameters were similar pre- and postoperatively. The experience of the observer and the definition and ability to measure the parameters themselves were sources of variation. Cite this article: Bone Joint J 2018;100-B:596–602


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1217 - 1222
1 Sep 2009
King RJ Makrides P Gill JA Karthikeyan S Krikler SJ Griffin DR

We have developed a novel method of calculating the radiological magnification of the hip using two separate radio-opaque markers. We recruited 74 patients undergoing radiological assessment following total hip replacement. Both the new double marker and a conventional single marker were used by the radiographer at the time of x-ray. The predicted magnification according to each marker was calculated, as was the true radiological magnification of the components. The correlation between true and predicted magnification was good using the double marker (r = 0.90, n = 74, p < 0.001), but only moderate for the single marker (r = 0.50, n = 63, p < 0.001). The median error was significantly less for the double marker than for the single (1.1% vs 4.8%, p < 0.001). The double marker method demonstrated excellent validity (intraclass correlation coefficient = 0.89), in contrast to the single marker (0.32). The double marker method appears to be superior to the single marker method when used in the clinical environment


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1321 - 1329
1 Oct 2012
Sarmah SS Patel S Hossain FS Haddad FS

Radiological assessment of total and unicompartmental knee replacement remains an essential part of routine care and follow-up. Appreciation of the various measurements that can be identified radiologically is important. It is likely that routine plain radiographs will continue to be used, although there has been a trend towards using newer technologies such as CT, especially in a failing knee, where it provides more detailed information, albeit with a higher radiation exposure. The purpose of this paper is to outline the radiological parameters used to evaluate knee replacements, describe how these are measured or classified, and review the current literature to determine their efficacy where possible


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 337 - 343
1 Mar 2017
Ahmed I Salmon L Roe J Pinczewski L

Aims. The aim of this study was to investigate the long-term clinical and radiological outcome of patients who suffer recurrent injuries to the anterior cruciate ligament (ACL) after reconstruction and require revision surgery. Patients and Methods. From a consecutive series of 200 patients who underwent primary reconstruction following rupture of the ACL, we identified 36 who sustained a further rupture, 29 of whom underwent revision surgery. Patients were reviewed prospectively at one, two, seven, 15 and about 20 years after their original surgery. Primary outcome measures were the number of further ruptures, the posterior tibial slope (PTS), and functional and radiological outcomes. These were compared with a gender and age matched cohort of patients who underwent primary ACL reconstruction only. Results. At a mean follow-up of 18.3 years (14.3 to 20.2), 29 patients had undergone revision surgery and within this revision group 11 had sustained more than three ruptures of the ACL (3 to 6). The mean age at the time of revision reconstruction was 26.4 years (14 to 54). The mean PTS was significantly higher in those patients who suffered a further injury to the ACL (11°) compared with the control group (9°) (p < 0.001). The mean PTS in those patients who sustained more than three ruptures was 12°. Conclusion. Patients who suffer recurrent injuries to the ACL after reconstruction have poorer functional and radiological outcomes than those who suffer a single injury. The causes of further injury are likely to be multifactorial but an increased PTS appears to have a significant association with recurrent ACL injuries. Cite this article: Bone Joint J 2017;99-B:337–43


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1435 - 1440
1 Oct 2015
Heidt C Hollander K Wawrzuta J Molesworth C Willoughby K Thomason P Khot A Graham HK

Pelvic obliquity is a common finding in adolescents with cerebral palsy, however, there is little agreement on its measurement or relationship with hip development at different gross motor function classification system (GMFCS) levels. . The purpose of this investigation was to study these issues in a large, population-based cohort of adolescents with cerebral palsy at transition into adult services. . The cohort were a subset of a three year birth cohort (n = 98, 65M: 33F, with a mean age of 18.8 years (14.8 to 23.63) at their last radiological review) with the common features of a migration percentage greater than 30% and a history of adductor release surgery. . Different radiological methods of measuring pelvic obliquity were investigated in 40 patients and the angle between the acetabular tear drops (ITDL) and the horizontal reference frame of the radiograph was found to be reliable, with good face validity. This was selected for further study in all 98 patients. . The median pelvic obliquity was 4° (interquartile range 2° to 8°). There was a strong correlation between hip morphology and the presence of pelvic obliquity (effect of ITDL on Sharpe’s angle in the higher hip; rho 7.20 (5% confidence interval 5.59 to 8.81, p < 0.001). This was particularly true in non-ambulant adolescents (GMFCS IV and V) with severe pelvic obliquity, but was also easily detectable and clinically relevant in ambulant adolescents with mild pelvic obliquity. . The identification of pelvic obliquity and its management deserves closer scrutiny in children and adolescents with cerebral palsy. Cite this article: Bone Joint J 2015;97-B:1435–40


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1096 - 1099
1 Aug 2010
Sutherland AG Cooper K Alexander LA Nicol M Smith FW Scotland TR

We identified a series of 128 patients who had unilateral open reconstruction of the anterior cruciate ligament (ACL) by a single surgeon between 1993 and 2000. In all, 79 patients were reviewed clinically and radiologically eight to 15 years after surgery. Assessment included measurement of the Lysholm and Tegner scores, the ACL quality-of-life score and the Short Form-12 score, as well as the International Knee Documentation Committee clinical assessment, measurement of laxity by the KT-1000 arthrometer, a single-leg hop test and standardised radiography of both knees using the uninjured knee as a control. Of the injured knees, 46 (57%) had definite radiological evidence of osteoarthritis (Kellgren-Lawrence grade 2 or 3), with a mean difference between the injured and non-injured knees of 1.2 grades. The median ACL quality-of-life score was 80 (interquartile range (IQR) 60 to 90), the Lysholm score 84 (IQR 74 to 95), the Short Form-12 physical component score 54 (IQR 49 to 56) and the mean Hop Index 0.94 (0.52 to 1.52). In total 58 patients were graded as normal, 20 as nearly normal and one as abnormal on the KT-1000 assessment and pivot-shift testing. Taking the worst-case scenario of assuming all non-attenders (n = 48), two septic failures and one identified unstable knee found at review to be failures, the failure rate was 40%. Only two of the patients reviewed stated that they would not have similar surgery again. Open reconstruction of the ACL gives good, durable functional results, but with a high rate of radiologically evident osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 743 - 746
1 May 2010
Colegate-Stone T Allom R Singh R Elias DA Standring S Sinha J

The aim of this study was to establish a classification system for the acromioclavicular joint using cadaveric dissection and radiological analyses of both reformatted computed tomographic scans and conventional radiographs centred on the joint. This classification should be useful for planning arthroscopic procedures or introducing a needle and in prospective studies of biomechanical stresses across the joint which may be associated with the development of joint pathology. We have demonstrated three main three-dimensional morphological groups namely flat, oblique and curved, on both cadaveric examination and radiological assessment. These groups were recognised in both the coronal and axial planes and were independent of age


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 560 - 564
1 Apr 2010
Miller AN Prasarn ML Lorich DG Helfet DL

We have examined the accuracy of reduction and the functional outcomes in elderly patients with surgically treated acetabular fractures, based on assessment of plain radiographs and CT scans. There were 45 patients with such a fracture with a mean age of 67 years (59 to 82) at the time of surgery. All patients completed SF-36 questionnaires to determine the functional outcome at a mean follow-up of 72.4 months (24 to 188). All had radiographs and a CT scan within one week of surgery. The reduction was categorised as ‘anatomical’, ‘imperfect’, or ‘poor’. Radiographs classified 26 patients (58%) as anatomical,13 (29%) as imperfect and six (13%) as poor. The maximum displacement on CT showed none as anatomical, 23 (51%) as imperfect and 22 (49%) as poor, but this was not always at the weight-bearing dome. SF-36 scores showed functional outcomes comparable with those of the general elderly population, with no correlation with the radiological reduction. Perfect anatomical reduction is not necessary to attain a good functional outcome in acetabular fractures in the elderly


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 980 - 983
1 Jul 2010
Hong JY Suh SW Modi HN Hur CY Song HR Park JH

In order to determine the epidemiology of adult scoliosis in the elderly and to analyse the radiological parameters and symptoms related to adult scoliosis, we carried out a prospective cross-sectional radiological study on 1347 adult volunteers. There were 615 men and 732 women with a mean age of 73.3 years (60 to 94), and a mean Cobb angle of 7.55° (. sd. 5.95). In our study, 478 subjects met the definition of scoliosis (Cobb angle ≥10°) showing a prevalence of 35.5%. There was a significant difference in the epidemiological distribution and prevalence between the age and gender groups. The older adults showed a larger prevalence and more severe scoliosis, more prominent in women (p = 0.004). Women were more affected by adult scoliosis and showed more linear correlation with age (p < 0.001). Symptoms were more severe in those with scoliosis than in the normal group, but were similar between the mild, moderate and severe scoliosis groups (p = 0.224) and between men and women (p = 0.231). Adult scoliosis showed a significant relationship with lateral listhesis, vertebral rotation, lumbar hypolordosis, sagittal imbalance and a high level of the L4–5 disc (p < 0.0001, p < 0.0001, p = 0.002, p = 0.002, p < 0.0001 respectively). Lateral listhesis, lumbar hypolordosis and sagittal imbalance were related to symptoms (p < 0.0001, p = 0.001, p < 0.0001 respectively)


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis. Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 145 - 150
1 Feb 2011
Ng CY McQueen MM

The fracture most commonly treated by orthopaedic surgeons is that of the distal radius. However, as yet there is no consensus on what constitutes an ‘acceptable’ radiological position before or after treatment. This should be defined as the position that will predict good function in the majority of cases. In this paper we review the radiological indices that can be measured in fractures of the distal radius and try to identify potential predictors of functional outcome. In patients likely to have high functional demands, we recommend that the articular reconstruction be achieved with less than 2 mm of gap or step-off, the radius be restored to within 2 mm of its normal length, and that carpal alignment be restored. The ultimate aim of treatment is a pain-free, mobile wrist joint without functional limitation


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 334 - 338
1 Mar 2012
Hooper GJ Maxwell AR Wilkinson B Mathew J Woodfield TBF Penny ID Burn PJ Frampton C

We carried out a prospective investigation into the radiological outcomes of uncemented Oxford medial compartment unicondylar replacement in 220 consecutive patients (231 knees) performed in a single centre with a minimum two-year follow-up. The functional outcomes using the mean Oxford knee score and the mean high-activity arthroplasty score were significantly improved over the pre-operative scores (p < 0.001). There were 196 patients with a two-year radiological examination performed under fluoroscopic guidance, aiming to provide images acceptable for analysis of the bone–implant interface. Of the six tibial zones examined on each knee on the anteroposterior radiograph, only three had a partial radiolucent line. All were in the medial aspect of the tibial base plate (zone 1) and all measured < 1 mm. All of these patients were asymptomatic. There were no radiolucent lines seen around the femoral component or on the lateral view. There was one revision for loosening at one year due to initial inadequate seating of the tibial component. These results confirm that the early uncemented Oxford medial unicompartmental compartmental knee replacements were reliable and the incidence of radiolucent lines was significantly decreased compared with the reported results of cemented versions of this implant. These independent results confirm those of the designing centre



The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1704 - 1710
1 Dec 2016
Nakamura N Inaba Y Aota Y Oba M Machida J N. Aida Kurosawa K Saito T

Aims. To determine the normal values and usefulness of the C1/4 space available for spinal cord (SAC) ratio and C1 inclination angle, which are new radiological parameters for assessing atlantoaxial instability in children with Down syndrome. Patients and Methods. We recruited 272 children with Down syndrome (including 14 who underwent surgical treatment), and 141 children in the control group. All were aged between two and 11 years. The C1/4 SAC ratio, C1 inclination angle, atlas-dens interval (ADI), and SAC were measured in those with Down syndrome, and the C1/4 SAC ratio and C1 inclination angle were measured in the control group. Results. The mean C1/4 SAC ratio in those requiring surgery with Down syndrome, those with Down syndrome not requiring surgery and controls were 0.63 (standard deviation (. sd. ) 0.1), 1.15 (. sd . 0.13) and 1.29 (. sd. 0.14), respectively, and the mean C1 inclination angles were -3.1° (. sd.  10.7°), 15.8° (. sd. 7.3) and 17.2° (. sd. 7.3), in these three groups, respectively. The mean ADI and SAC in those with Down syndrome requiring surgery and those with Down syndrome not requiring surgery were 9.8 mm (. sd. 2.8) and 4.3 mm (. sd. 1.0), and 11.1 mm (. sd. 2.6) and 18.5 mm (. sd. 2.4), respectively. Conclusion. The normal values of the C1/4 SAC ratio and the C1 inclination angle were found to be about 1.2° and 15º, respectively. Cite this article: Bone Joint J 2016;98-B:1704–10


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1224 - 1227
1 Sep 2006
Arumilli BRB Koneru P Garg NK Davies R Saville S Sampath J Bruce C

The practice of regular radiological follow-up of infants with a positive family history of developmental dysplasia of the hip is based on the widespread belief that primary acetabular dysplasia is a genetic disorder which can occur in the absence of frank subluxation or dislocation. We reviewed all infants who were involved in our screening programme for developmental dysplasia of the hip, between November 2002 and January 2004, and who had a normal clinical and ultrasound examination of the hip at six to eight weeks of age, but who, because of a family history of developmental dysplasia of the hip, had undergone further radiography after an interval of 6 to 12 months. The radiographs of 89 infants were analysed for signs of late dysplasia of the hip and assessed independently by three observers to allow for variability of measurement. There were 11 infants (11%) lost to follow-up. All the patients had normal radiographs at the final follow-up and none required any intervention. We therefore question the need for routine radiological follow-up of infants with a positive family history of developmental dysplasia of the hip, but who are normal on clinical examination and assessment by ultrasound screening when six to eight weeks old


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1369 - 1374
1 Oct 2007
Nelson D Zenios M Ward K Ramachandran M Little DG

The deformity index is a new radiological measurement of the degree of deformity of the femoral head in unilateral Perthes’ disease. Its values represent a continuous outcome measure of deformity incorporating changes in femoral epiphyseal height and width compared with the unaffected side. The sphericity of the femoral head in 30 radiographs (ten normal and 20 from patients with Perthes’ disease) were rated blindly as normal, mild, moderate or severe by three observers. Further blinded measurements of the deformity index were made on two further occasions with intervals of one month. There was good agreement between the deformity index score and the subjective grading of deformity. Intra- and interobserver agreement for the deformity index was high. The intraobserver intraclass correlation coefficient for each observer was 0.98, 0.99 and 0.97, respectively, while the interobserver intraclass correlation coefficient was 0.98 for the first and 0.97 for the second set of calculations. We also reviewed retrospectively 96 radiographs of children with Perthes’ disease, who were part of a multicentre trial which followed them to skeletal maturity. We found that the deformity index at two years correlated well with the Stulberg grading at skeletal maturity. A deformity index value above 0.3 was associated with the development of an aspherical femoral head. Using a deformity index value of 0.3 to divide groups for risk gives a sensitivity of 80% and specificity of 81% for predicting a Stulberg grade of III or IV. We conclude that the deformity index at two years is a valid and reliable radiological outcome measure in unilateral Perthes’ disease


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 304 - 309
1 Mar 2006
Macheras GA Papagelopoulos PJ Kateros K Kostakos AT Baltas D Karachalios TS

Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component and the acetabular host bed which ranged from 1 to 5 mm. All patients were followed up clinically and radiologically for a mean of 7.3 years (7 to 7.5). The 25 hips with the 1 to 5 mm gaps were studied for component migration at two years using the Einzel-Bild-Roentgen-Analyse (EBRA) digital measurement method. At 24 weeks all the post-operative gaps were filled with bone and no acetabular component had migrated. The radiographic outcome of all 86 components showed no radiolucent lines and no evidence of lysis. No acetabular implant was revised. There were no dislocations or other complications. The bridging of the interface gaps (up to 5 mm) by the trabecular metal monoblock acetabular component indicates the strong osteoconductive, and possibly osteoinductive, properties of trabecular metal


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°. Cite this article: Bone Joint J 2013;95-B:1101–5


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 893 - 899
1 Jul 2013
Diaz-Ledezma C Novack T Marin-Peña O Parvizi J

Orthopaedic surgeons have accepted various radiological signs to be representative of acetabular retroversion, which is the main characteristic of focal over-coverage in patients with femoroacetabular impingement (FAI). Using a validated method for radiological analysis, we assessed the relevance of these signs to predict intra-articular lesions in 93 patients undergoing surgery for FAI. A logistic regression model to predict chondral damage showed that an acetabular retroversion index (ARI) > 20%, a derivative of the well-known cross-over sign, was an independent predictor (p = 0.036). However, ARI was less significant than the Tönnis classification (p = 0.019) and age (p = 0.031) in the same model. ARI was unable to discriminate between grades of chondral lesions, while the type of cam lesion (p = 0.004) and age (p = 0.047) were able to. Other widely recognised signs of acetabular retroversion, such as the ischial spine sign, the posterior wall sign or the cross-over sign were irrelevant according to our analysis. Regardless of its secondary predictive role, an ARI > 20% appears to be the most clinically relevant radiological sign of acetabular retroversion in symptomatic patients with FAI. Cite this article: Bone Joint J 2013;95-B:893–9


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1602 - 1607
1 Dec 2007
Beard DJ Pandit H Ostlere S Jenkins C Dodd CAF Murray DW

Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthritis, pre-operative anterior knee pain and the radiological status of the patellofemoral joint were defined using the Altman and Ahlback systems. Outcome was evaluated at two years with the Oxford knee score and the American Knee Society score. Pre-operatively 54 knees (54%) had anterior knee pain. The clinical outcome was independent of the presence or absence of pre-operative anterior knee pain. Degenerative changes of the patellofemoral joint were seen in 54 patients (54%) on the skyline radiographs, including ten knees (10%) with joint space obliteration. Patients with medial patellofemoral degeneration had a similar outcome to those without. For some outcome measures patients with lateral patellofemoral degeneration had a worse score than those without, but these patients still had a good outcome, with a mean Oxford knee score of 37.6 (SD 9.5). These results show that neither anterior knee pain nor radiologically-demonstrated medial patellofemoral joint degeneration should be considered a contraindication to Oxford unicompartmental knee replacement. With lateral patellofemoral degeneration the situation is less well defined and caution should be observed


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 745 - 749
1 Sep 1994
Dejour H Bonnin M

Anterior tibial translation was measured in both knees using the radiological Lachman test and the lateral monopodal stance tests in 281 patients with unilateral anterior cruciate ligament (ACL) rupture. Measurements of translation in the medial compartment were more useful than those in the lateral compartment. Measurement of anterior tibial translation in the medial compartment using the radiological Lachman test showed ACL rupture in 92% of cases compared with 70% for the lateral monopodal stance test. In normal and in ACL-ruptured knees the monopodal stance test showed that every 10 degrees increase in posterior inclination of the tibial plateau was associated with a 6 mm increase in anterior tibial translation; the radiological Lachman test showed a 3 mm increase for every 10 degrees increase in tibial slope


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 650 - 657
1 May 2011
Hasegawa K Shimoda H Kitahara K Sasaki K Homma T

We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone > 2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped. Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 889 - 894
1 Jul 2012
Burston BJ Barnett AJ Amirfeyz R Yates PJ Bannister GC

We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21 patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 6 - 8
1 Jan 1989
Broughton N Brougham D Cole W Menelaus M

We investigated the reproducibility of the various radiological methods of assessment of hip dysplasia by making 474 assessments of hips and quantifying the inter-observer and intra-observer variation. There was a wide range of variability between the readings made by different observers and by one observer on two occasions. A measurement of acetabular index has to be given a range of +/- 6 degrees in order to be 95% confident of including the true measurement. We found the most helpful measurements to be the acetabular index, up to the age of eight years; the centre-edge angle, over the age of five years; and Smith's c/b ratio and neck-shaft angle. We feel, however, that the change in value over a series of radiographs in the same child is much more valuable. Single readings of all the radiological measurements investigated in this study were unreliable


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 323 - 326
1 Mar 1999
Aboulafia AJ Monson DK Kennon RE

The systemic effects of diabetes mellitus are well recognised. The heart, kidney, central and peripheral nervous systems, and the distal parts of the limbs are often the site of end-organ damage resulting from ischaemia. Infarction of large muscle groups in the limb, not associated with gangrene, is uncommon. There have been few reported cases other than radiological descriptions of diabetic muscle infarcts. While previous reports have illustrated some of the clinical and radiological characteristics of this condition, the paucity of published cases makes it difficult to determine the most appropriate methods of diagnosis and treatment. During a five-year period we treated 14 patients with diabetes mellitus, aged from 32 to 59 years, who were referred to a musculoskeletal oncology service for suspected soft-tissue sarcoma, but were subsequently found to have a diabetic muscle infarct. Closed needle biopsy was performed in 13 without complications. In 12 patients, the symptoms resolved without surgical treatment


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1617 - 1625
1 Dec 2013
Schmitz MWJL Timmer C Rijnen WHC Gardeniers JWM Schreurs BW

Despite the worldwide usage of the cemented Contemporary acetabular component (Stryker), no published data are available regarding its use in patients aged < 50 years. We undertook a mid- to long-term follow-up study, including all consecutive patients aged < 50 years who underwent a primary total hip replacement using the Contemporary acetabular component with the Exeter cemented stem between January 1999 and January 2006. There were 152 hips in 126 patients, 61 men and 65 women, mean age at surgery 37.6 years (16 to 49 yrs). One patient was lost to follow-up. Mean clinical follow-up of all implants was 7.6 years (0.9 to 12.0). All clinical questionnaire scores, including Harris hip score, Oxford hip score and several visual analogue scales, were found to have improved. The eight year survivorship of all acetabular components for the endpoints revision for any reason or revision for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2 to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up was complete for 146 implants. The eight year survival for the endpoint radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving implants were considered radiologically loose but were asymptomatic. The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent lines (n = 20, 13.9%) in the 144 surviving cups indicates a need for continued observation in the second decade of follow-up in order to observe their influence on long-term survival. The clinical and radiological data resulting in a ten-year survival rate > 90% in young patients support the use of the Contemporary acetabular component in this specific patient group. Cite this article: Bone Joint J 2013;95-B:1617–25


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 506 - 512
1 Apr 2020
de Bodman C Ansorge A Tabard A Amirghasemi N Dayer R

Aims

The direct posterior approach with subperiosteal dissection of the paraspinal muscles from the vertebrae is considered to be the standard approach for the surgical treatment of adolescent idiopathic scoliosis (AIS). We investigated whether or not a minimally-invasive surgery (MIS) technique could offer improved results.

Methods

Consecutive AIS patients treated with an MIS technique at two tertiary centres from June 2013 to March 2016 were retrospectively included. Preoperative patient deformity characteristics, perioperative parameters, power of deformity correction, and complications were studied. A total of 93 patients were included. The outcome of the first 25 patients and the latter 68 were compared as part of our safety analysis to examine the effect of the learning curve.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 661 - 663
1 Aug 1989
Charnley R Bickerstaff D Wallace W Stevens A

In a prospective study of the measurement of osteoporosis in patients with fracture of the femoral neck, we compared a histological with a radiological method. We found no significant correlation between histological planimetry and the radiological six metacarpal hand index in patients with either cervical or trochanteric fractures. This demonstrates that metacarpal morphometry cannot predict histological osteoporosis of the iliac crest


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1403 - 1408
1 Oct 2012
Hannemann PFW Göttgens KWA van Wely BJ Kolkman KA Werre AJ Poeze M Brink PRG

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks. A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group. We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 504 - 506
1 Jul 1992
Benli I Akalin S Boysan E Mumcu E Kis M Turkoglu D

Osteopoikilosis is a rare condition showing characteristic sclerotic lesions on radiographic examination, which are diagnostic for the trait. We report four patients presenting with various complaints and 49 members of their families who later were found to have osteopoikilosis. The mean age of all 53 was 27.5 years and the male:female ratio was 33:20. Most had lesions in the small tubular bones. We studied the epidemiological, clinical and radiological features of these patients and from the pedigrees conclude that the disease is inherited as an autosomal dominant


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1618 - 1624
1 Dec 2006
Bhandari M Matta J Ferguson T Matthys G

We aimed to identify variables associated with clinical and radiological outcome following fractures of the acetabulum associated with posterior dislocation of the hip. Using a prospective database of 1076 such fractures, we identified 109 patients with this combined injury managed operatively within three weeks and followed up for two or more years. The patients had a mean age of 42 years (15 to 79), 78 (72%) were male, and 84 (77%) had been involved in motor vehicle accidents. Using multivariate analysis the quality of reduction of the fracture was identified as the only significant predictor of radiological grade, clinical function and the development of post-traumatic arthritis (p < 0.001). All patients lacking anatomical reduction developed arthritis whereas only 25.5% (24 patients) with an anatomical reduction did so (p = 0.05). The quality of the reduction of the fracture is the most important variable in forecasting the outcome for patients with this injury. The interval to reduction of the dislocation of the hip may be less important than previously described


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 31 - 36
1 Jan 2003
Müller U Gautier E Roeder C Busato A

We assessed differences in the incidence and appearance of the radiological signs of loosening of the cup for various types of design. This was an observational study based on hip registry data of 15 340 patients with 17 951 total hip arthroplasties collected over a period of 33 years in 49 hospitals in Central Europe. The threaded and the press-fit titanium cups showed significantly less aseptic loosening than the other systems. The direction of migration and the frequency of the radiological signs of loosening differed between the cup systems and were time-dependent. Our findings indicate the superiority of uncemented threaded cups and press-fit titanium cups over other designs of cup


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 872 - 874
1 Nov 1993
Williams W McCullough C

We assessed 57 total hip arthroplasties in 34 adolescents with juvenile chronic arthritis using standard radiological techniques at an average of 4.7 years (20 months to 9 years) after surgery. The incidence of overall loosening was 24.6% (14 hips), but hips with a follow-up of more than five years had a loosening rate of 43.5% (10 hips; p < 0.01)


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 80 - 84
1 Jan 1999
Trail IA Nuttall D Stanley JK

We undertook a radiological analysis of 186 standard Souter implants to determine survivorship and to analyse the pattern of failure in those needing revision. The implants had been inserted as a primary procedure in patients with rheumatoid arthritis of the elbow at our hospital over the last 12 years. Taking revision as an endpoint, the survivorship after 12 years was 87%. If, however, revision and loosening, defined as the Hindex value equivalent to demarcation of 1 mm around the whole implant, are also included, the survivorship falls to 80%. Of the 24 implants revised, 18 (75%) were for problems with the humeral component, three (12.5%) with the ulnar component and three (12.5%) for instability. Loosening of the humeral component occurred when the implant extended into the humerus, with the tip moving anteriorly on to the anterior humeral cortex. Our study indicates that loosening can be predicted by the rate of change in this angle of extension of the prosthesis


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1704 - 1709
1 Dec 2015
Drexler M Gortzak Y Sternheim A Kollender Y Amar E Bickels J

Excision of the proximal femur for tumour with prosthetic reconstruction using a bipolar femoral head places a considerable load on the unreplaced acetabulum. . We retrospectively reviewed the changes which occur around the affected hip joint by evaluating the post-operative radiographs of 65 consecutive patients who underwent proximal prosthetic arthroplasty of the femur, and in whom an acetabular component had not been used. There were 37 men and 28 women with a mean age of 57.3 years (17 to 93). Radiological assessment included the extent of degenerative change in the acetabulum, heterotopic ossification, and protrusio acetabuli. . The mean follow-up was 9.1 years (2 to 11.8). Degenerative changes in the acetabulum were seen in three patients (4.6%), Brooker grade 1 or 2 heterotopic ossification in 17 (26%) and protrusion of the prosthetic head in nine (13.8%). . A total of eight patients (12.3%) needed a revision. Five were revised to the same type of prosthesis and three (4.6%) were converted to a total hip arthroplasty. . We conclude that radiological evidence of degenerative change, heterotopic ossification and protrusion occur in a few patients who undergo prosthetic arthroplasty of the proximal femur for tumour. The limited extent of these changes and the lack of associated symptoms do not justify the routine arthroplasty of the acetabulum in these patients. . Cite this article: Bone Joint J 2015;97-B:1704–9


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1106 - 1110
1 Aug 2014
Malhotra R Kiran Kumar GN K. Digge V Kumar V

Giant cell tumour is the most common aggressive benign tumour of the musculoskeletal system and has a high rate of local recurrence. When it occurs in proximity to the hip, reconstruction of the joint is a challenge. Options for reconstruction after wide resection include the use of a megaprosthesis or an allograft-prosthesis composite. We performed a clinical and radiological study to evaluate the functional results of a proximal femoral allograft-prosthesis composite in the treatment of proximal femoral giant cell tumour after wide resection. This was an observational study, between 2006 and 2012, of 18 patients with a mean age of 32 years (28 to 42) and a mean follow-up of 54 months (18 to 79). We achieved excellent outcomes using Harris Hip Score in 13 patients and a good outcome in five. All allografts united. There were no complications such as infection, failure, fracture or resorption of the graft, or recurrent tumour. Resection and reconstruction of giant cell tumours with proximal femoral allograft–prosthesis composite is a better option than using a prosthesis considering preservation of bone stock and excellent restoration of function. A good result requires demanding bone banking techniques, effective measures to prevent infection and stability at the allograft-host junction. . Cite this article: Bone Joint J 2014; 96-B:1106–10


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1309 - 1315
1 Oct 2006
Shetty N Hamer AJ Stockley I Eastell R Willkinson JM

Bisphosphonates reduce peri-prosthetic bone loss in the short term after total hip replacement but the mid- and longer term effects are not known. The aims of this randomised trial were to examine the effect of a single dose of 90 mg of pamidronate on the clinical and radiological outcome and peri-prosthetic bone mineral density in 50 patients (56 hips) over a five-year period, following total hip replacement. At five years, 37 patients (42 hips) returned for assessment. The Harris hip scores were similar in the pamidronate and placebo groups throughout the study. Also at five years, four patients, two from each group had osteolytic lesions on plain radiography. These were located around the acetabular component in three patients and in the femoral calcar in one. The femoral and acetabular peri-prosthetic bone mineral density in the pamidronate group and the control group was similar at five years. Pamidronate given as a single post-operative dose does not appear to influence the clinical outcome or prevent the development of osteolytic lesions at five years after total hip replacement


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1544 - 1550
1 Nov 2013
Uchiyama S Itsubo T Nakamura K Fujinaga Y Sato N Imaeda T Kadoya M Kato H

This multicentre prospective clinical trial aimed to determine whether early administration of alendronate (ALN) delays fracture healing after surgical treatment of fractures of the distal radius. The study population comprised 80 patients (four men and 76 women) with a mean age of 70 years (52 to 86) with acute fragility fractures of the distal radius requiring open reduction and internal fixation with a volar locking plate and screws. Two groups of 40 patients each were randomly allocated either to receive once weekly oral ALN administration (35 mg) within a few days after surgery and continued for six months, or oral ALN administration delayed until four months after surgery. Postero-anterior and lateral radiographs of the affected wrist were taken monthly for six months after surgery. No differences between groups was observed with regard to gender (p = 1.0), age (p = 0.916), fracture classification (p = 0.274) or bone mineral density measured at the spine (p = 0.714). The radiographs were assessed by three independent assessors. There were no significant differences in the mean time to complete cortical bridging observed between the ALN group (3.5 months (. se. 0.16)) and the no-ALN group (3.1 months (. se. 0.15)) (p = 0.068). All the fractures healed in the both groups by the last follow-up. Improvement of the Quick-Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, grip strength, wrist range of movement, and tenderness over the fracture site did not differ between the groups over the six-month period. Based on our results, early administration of ALN after surgery for distal radius fracture did not appear to delay fracture healing times either radiologically or clinically. Cite this article: Bone Joint J 2013;95-B:1544–50


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1034 - 1037
1 Sep 2000
Kothari P Freeman B Grevitt M Kerslake R

Injury to the spinal cord without radiological abnormality often occurs in the skeletally immature cervical and thoracic spine. We describe four adult patients with this diagnosis involving the cervical spine with resultant quadriparesis. The relevant literature is reviewed. The implications for initial management of the injury, the role of MRI and the need for a high index of suspicion are highlighted


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 326 - 333
1 Mar 2016
Morvan A Moreau S Combourieu B Pansard E Marmorat JL Carlier R Judet T Lonjon G

Aims. The primary aim of this study was to analyse the position of the acetabular and femoral components in total hip arthroplasty undertaken using an anterior surgical approach. . Patients and Methods. In a prospective, single centre study, we used the EOS imaging system to analyse the position of components following THA performed via the anterior approach in 102 patients (103 hips) with a mean age of 64.7 years (. sd. 12.6). Images were taken with patients in the standing position, allowing measurement of both anatomical and functional anteversion of the acetabular component. . Results. The mean inclination of the acetabular component was 39° (standard deviation (. sd). 6), the mean anatomical anteversion was 30° (. sd. 10), and the mean functional anteversion was 31° (. sd. 8) five days after surgery. The mean anteversion of the femoral component was 20° (. sd.  11). Anatomical and functional anteversion of the acetabular component differed by >  10° in 23 (22%) cases. Pelvic tilt was the only pre-operative predictive factor of this difference. Conclusion. Our study showed that anteversion of the acetabular component following THA using the anterior approach was greater than the recommended target value, and that substantial differences were observed in some patients when measured using two different measurement planes. If these results are confirmed by further studies, and considering that the anterior approach is intended to limit the incidence of dislocation, a new correlation study for each reference plane (anatomical and functional) will be necessary to define a ‘safe zone’ for use with the anterior approach. Take home message: EOS imaging system is helpful in the pre-operative and post-operative radiological analysis of total hip arthroplasty. Cite this article: Bone Joint J 2016;98-B:326–333


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 439 - 443
1 May 1990
Kobayashi S Terayama K

We studied the radiographs of 211 low-friction arthroplasties, followed for five to 15 years after operation. The first 92 simple hemispherical sockets were fixed with an old technique: eburnated bone in the acetabular roof was removed and only a few large anchor holes were bored for cement fixation. With the next 119 sockets, 111 of which were flanged, the eburnated and subchondral bone was preserved and multiple small anchor holes were used. The modified technique and the use of flanged sockets significantly improved the late radiological findings as regards socket demarcation and wear. On the femoral side, the intramedullary canal filling ratio, the distal packing of cement, calcar resorption and atrophy of the femoral cortex were correlated with prosthetic subsidence


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1240 - 1246
1 Sep 2011
Melis B DeFranco M Lädermann A Molé D Favard L Nérot C Maynou C Walch G

Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs. A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p < 0.001), as was resorption of the greater (p < 0.001) and lesser tuberosities (p = 0.009)


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 297 - 302
1 Mar 2019
Tamura K Takao M Hamada H Ando W Sakai T Sugano N

Aims

The aim of this study was to examine whether hips with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH) have significant asymmetry in femoral length, and to determine potential related factors.

Patients and Methods

We enrolled 90 patients (82 female, eight male) with DDH showing unilateral OA changes, and 43 healthy volunteers (26 female, 17 male) as controls. The mean age was 61.8 years (39 to 93) for the DDH groups, and 71.2 years (57 to 84) for the control group. Using a CT-based coordinate measurement system, we evaluated the following vertical distances: top of the greater trochanter to the knee centre (femoral length GT), most medial prominence of the lesser trochanter to the knee centre (femoral length LT), and top of the greater trochanter to the medial prominence of the lesser trochanter (intertrochanteric distance), along with assessments of femoral neck anteversion and neck shaft angle.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1106 - 1111
1 Aug 2018
Knapik DM Sanders JO Gilmore A Weber DR Cooperman DR Liu RW

Aims

Using 90% of final height as a benchmark, we sought to develop a quick, quantitative and reproducible method of estimating skeletal maturity based on topographical changes in the distal femoral physis.

Patients and Methods

Serial radiographs of the distal femoral physis three years prior to, during, and two years following the chronological age associated with 90% of final height were analyzed in 81 healthy children. The distance from the tip of the central peak of the distal femoral physis to a line drawn across the physis was normalized to the physeal width.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 25 - 30
1 Feb 1976
Marklund T Tillberg B

Subtrochanteric osteotomy has been reported to interrupt the destructive phase of coxa plana and speed up the rate of healing. The aim of this investigation was to test the validity of these statements. The material comprised twenty-five patients treated by osteotomy and thirty-three patients treated by support in a Thomas's splint. For every patient the extent of the radiological changes was estimated and plotted against time as a percentage of the normal epiphysial volume. The graph so obtained represents the rate of destruction and re-ossification, as well as the maximum involvement of the epiphysis. The curves for each group of patients were superimposed in a graph with all the minima coincident in time. The two patterns of curves are closely similar. It was confirmed statistically that the rates of destruction and re-ossification did not differ between the two groups. The results afford no evidence that osteotomy interrupts the disease or speeds up healing


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1610 - 1616
1 Dec 2013
Epinette J Asencio G Essig J Llagonne B Nourissat C

We report a multicentre prospective consecutive study assessing the long-term outcome of the proximally hydroxyapatite (HA)-coated ABG II monobloc femoral component in a series of 1148 hips in 1053 patients with a mean age at surgery of 64.77 years (22 to 80) at a mean follow-up of 10.84 years (10 to 15.25). At latest follow-up, the mean total Harris hip score was 94.7 points (. sd. ; 6.87; 49 to 100), and the mean Merle d’Aubigné–Postel score was 17.6 points (. sd. 1.12; 7 to 18). The mean total Engh radiological score score was 21.54 (. sd. 5.77; 3.5 to 27), with 95.81% of ‘confirmed ingrowth’, according to Engh’s classification. With aseptic loosening or pain as endpoints, three AGB II stems (0.26%) failed, giving a 99.7% survival rate (. se. 0.002; 95% confidence interval (CI) 0.994 to 1) at 14 years’ follow-up. The survival of patients ≤ 50 years of age (99.0% (. se. 0.011; 95% CI 0.969 to 1)) did not differ significantly from those of patients aged > 50 years (99.8% (. se. 0.002; 95% CI 0.994 to 1)). This study confirmed the excellent long-term results currently achieved with the ABG II proximally HA-coated monobloc stem. Cite this article: Bone Joint J 2013;95-B:1610–16


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 844 - 844
1 Jun 2009
Challis J


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 909 - 914
1 Jul 2018
Sheth NP Melnic CM Brown N Sporer SM Paprosky WG

Aims

The aim of this study was to examine the results of the acetabular distraction technique in achieving implantation of a stable construct, obtaining biological fixation, and producing healing of chronic pelvic discontinuity at revision total hip arthroplasty.

Patients and Methods

We identified 32 patients treated between 2006 and 2013 who underwent acetabular revision for a chronic pelvic discontinuity using acetabular distraction, and who were radiographically evaluated at a mean of 62 months (25 to 160). Of these patients, 28 (87.5%) were female. The mean age at the time of revision was 67 years (44 to 86). The patients represented a continuous series drawn from two institutions that adhered to an identical operative technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1043 - 1043
1 Nov 1997
Smith RM


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance. There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4). Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic. No medium-term difference in function or radiological outcome was identified between the two treatment groups


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1681 - 1688
1 Dec 2017
Jones CW Shatrov J Jagiello JM Millington S Hong A Boyle R Stalley PD

Aims

We present a retrospective review of patients treated with extracorporeally irradiated allografts for primary and secondary bone tumours with the mid- and long-term survivorship and the functional and radiographic outcomes.

Patients and Methods

A total of 113 of 116 (97.4%) patients who were treated with extracorporeally irradiated allografts between 1996 and 2014 were followed up. Forms of treatment included reconstructions, prostheses and composite reconstructions, both with and without vascularised grafts. Survivorship was determined by the Kaplan-Meier method. Clinical outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) scoring system, the Toronto Extremity Salvage Score (TESS) and Quality of Life-C30 (QLQ-30) measures. Radiographic outcomes were assessed using the International Society of Limb Salvage (ISOLS) radiographic scoring system.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1358 - 1363
1 Oct 2015
Hooper N Snell D Hooper G Maxwell R Frampton C

This study reports on the first 150 consecutive Oxford cementless unicompartmental knee arthroplasties (UKA) performed in an independent centre (126 patients). All eligible patients had functional scores (Oxford knee score and high activity arthroplasty score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically aligned radiographs were taken at five years and analysed for any evidence of radiolucent lines (RLLs), subsidence or loosening. The mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%) males. Excellent functional scores were maintained at five years and there were no progressive RLLs demonstrated on radiographs. Two patients underwent revision to a total knee arthroplasty giving a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84) component years with overall component survivorship of 98.7% at five years. There were a further four patients who underwent further surgery on the same knee, two underwent bearing exchanges for dislocation and two underwent lateral UKAs for disease progression. This was a marked improvement from other UKAs reported in New Zealand Joint Registry data and supports the designing centre’s early results.

Cite this article: Bone Joint J 2015;97-B:1358–63.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 934 - 934
1 Aug 2001
Angel J


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 978 - 983
1 Jul 2014
Wadsten MÅ Sayed-Noor AS Englund E Buttazzoni GG Sjödén GO

This paper investigates whether cortical comminution and intra-articular involvement can predict displacement in distal radius fractures by using a classification that includes volar comminution as a separate parameter.

A prospective multicentre study involving non-operative treatment of distal radius fractures in 387 patients aged between 15 and 74 years (398 fractures) was conducted. The presence of cortical comminution and intra-articular involvement according to the Buttazzoni classification is described. Minimally displaced fractures were treated with immobilisation in a cast while displaced fractures underwent closed reduction with subsequent immobilisation. Radiographs were obtained after reduction, at 10 to 14 days and after union. The outcome measure was re-displacement or union.

In fractures with volar comminution (Buttazzoni type 4), 96% (53 of 55) displaced. In intra-articular fractures without volar comminution (Buttazzoni 3), 72% (84 of 117) displaced. In extra-articular fractures with isolated dorsal comminution (Buttazzoni 2), 73% (106 of 145) displaced while in non-comminuted fractures (Buttazzoni 1), 16 % (13 of 81 ) displaced.

A total of 32% (53 of 165) of initially minimally displaced fractures later displaced. All of the initially displaced volarly comminuted fractures re-displaced. Displacement occurred in 31% (63 of 205) of fractures that were still in good alignment after 10 to 14 days.

Regression analysis showed that volar and dorsal comminution predicted later displacement, while intra-articular involvement did not predict displacement. Volar comminution was the strongest predictor of displacement.

Cite this article: Bone Joint J 2014;96-B:978–83.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 517 - 519
1 Aug 1986
Pemberton J


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 4 | Pages 781 - 781
1 Nov 1974
Lloyd-Roberts GC


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 2 | Pages 362 - 362
1 May 1971
Bonnin JG


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 320 - 332
1 May 1966
Golding C


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 353 - 355
1 Aug 1976
Matev I

Two boys with entrapment of the median nerve in the elbow joint after closed reduction of a posterior dislocation with fracture of the medial epicondyle showed a characteristic radiological sign in the anteroposterior radiograph after two to three months. The sign was a depression in the cortex on the ulnar side of the distal humeral metaphysis, with interruption of the local periosteal reaction. At operation in both patients the depression was found to correspond with the place where the median nerve reached the posterior surface of the humerus. Radiographs taken after transverse section of the nerve above and below the joint capsule and end-to-end suture showed gradual disappearance of the cortical depression


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 520 - 529
1 Aug 1985
Watt I


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1309 - 1316
1 Oct 2007
Gosvig KK Jacobsen S Palm H Sonne-Holm S Magnusson E

Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip.

The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (α) angle and the triangular index, a new measure of asphericity of the femoral head. In addition, the α-angle and the triangular index were assessed on the AP and lateral hip radiographs of 82 men and 82 women randomly selected from patients scheduled for total hip replacement (THR). The influence of varying femoral rotation on the α angle and the triangular index was also determined in femoral specimens under experimental conditions.

From the 2803 radiographs the mean AP α-angle was 55° (30° to 100°) in men and 45° (34° to 108°) in women. Approximately 6% of men and 2% of women had cam malformation. The α-angle and triangular index were highly inter-related. Of those patients scheduled for THR, 36 men (44%) and 28 women (35%) had cam malformation identifiable on the AP radiographs. The triangular index proved to be more reliable in detecting cam malformation when the hip was held in varying degrees of rotation.

The combination of the α-angle and the triangular index will allow examination of historical radiographs for epidemiological purposes in following the natural history of the cam deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1013 - 1018
1 Aug 2008
Goto K Kawanabe K Akiyama H Morimoto T Nakamura T

We reviewed 44 consecutive revision hip replacements in 38 patients performed using the cement-in-cement technique. All were performed for acetabular loosening in the presence of a well-fixed femoral component. The mean follow-up was 5.1 years (2 to 10.1). Radiological analysis at final follow-up indicated no loosening of the femoral component, except for one case with a continuous radiolucent line in all zones and peri-prosthetic fracture which required further revision. Peri-operative complications included nine proximal femoral fractures (20.4%) and perforation of the proximal femur in one hip. In five hips wiring or fixation with a braided suture was undertaken but no additional augmentation was required. There was an improvement in the mean Japanese Orthopaedic Association score from 55.5 (28 to 81) pre-operatively to 77.8 (40 to 95) at final follow-up (p < 0.001). Revision using a cement-in-cement technique allows increased exposure for acetabular revision and is effective in the medium term. Further follow-up is required to assess the long-term results in the light of in vitro studies which have questioned the quality of the cement-in-cement bond.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 222 - 226
1 Feb 2012
Rodrigues-Pinto R Freitas D Costa LD Sousa R Trigueiros M Lemos R Silva C Oliveira A

Radial osteotomy is currently advocated for patients with Lichtman’s stages II and IIIA of Kienböck’s disease; its place in the treatment of patients with stage IIIB disease remains controversial. The purpose of this study was to evaluate the medium-term results of this procedure and to compare the outcome in patients with stage IIIB disease and those with earlier stages (II and IIIA). A total of 18 patients (18 osteotomies) were evaluated both clinically and radiologically at a mean follow-up of 10.3 years (4 to 18). Range of movement, grip strength and pain improved significantly in all patients; the functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability (Disabilities of Arm, Shoulder and Hand questionnaire) was low at the final follow-up in all patients evaluated. Patients with stage IIIB disease, however, had a significantly lower grip strength, lower NSSK scores and higher disability than those in less advanced stages. Radiological progression of the disease was not noted in either group, despite the stage. Radial osteotomy seems effective in halting the progression of disease and improving symptoms in stages II, IIIA and IIIB. Patients with less advanced disease should be expected to have better clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 513 - 514
1 May 1996
Grahame R


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 388 - 388
1 May 1972
Devas MB


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 471 - 476
1 Apr 2012
Holland JP Langton DJ Hashmi M

We present the clinical results and survivorship of consecutive 100 Birmingham Hip Resurfacings in 90 patients at a minimum follow-up of ten years. All procedures were carried out by an independent surgeon who commenced a prospective study in 1998. Patients were assessed clinically using the Western Ontario and McMaster Universities osteoarthritis index, Short-Form 36, Harris hip score and University of California, Los Angeles activity score. Radiological analysis was performed by an independent observer and blood metal ion levels concentrations were measured at ten years post-operatively in 62 patients. The median acetabular component inclination was 46.2° (34° to 59°) and anteversion 11.0° (0° to 30°). The median chromium concentration in the unilateral group was 1.74 (0.41 to 15.23) and for the bilateral group was 2.98 (1.57 to 18.01). The equivalent values for cobalt were 1.67 (0.54 to 20.4) and 1.88 (1.38 to 19.32).

In total there were eight failures giving an overall survival at ten years of 92% (95% confidence interval (CI) 86.7 to 97.3). BHR in male patients had an improved survivorship of 94.6% (95% CI 89.4 to 100) compared with females at 84.6% (95% CI 70.7 to 98.5), but this did not reach statistical significance (p = 0.119). Four of the nine BHRs with a bearing diameter of 42 mm failed.

The overall results were consistent with data produced from other centres in that the clinical outcome of large male patients was extremely encouraging, whereas the survival of the smaller joints was less satisfactory.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 786 - 792
1 Jun 2016
Schotanus MGM Sollie R van Haaren EH Hendrickx RPM Jansen EJP Kort NP

Aims

This prospective randomised controlled trial was designed to evaluate the outcome of both the MRI- and CT-based patient-specific matched guides (PSG) from the same manufacturer.

Patients and Methods

A total of 137 knees in 137 patients (50 men, 87 women) were included, 67 in the MRI- and 70 in the CT-based PSG group. Their mean age was 68.4 years (47.0 to 88.9). Outcome was expressed as the biomechanical limb alignment (centre hip-knee-ankle: HKA-axis) achieved post-operatively, the position of the individual components within 3° of the pre-operatively planned alignment, correct planned implant size and operative data (e.g. operating time and blood loss).


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 515 - 516
1 May 1991
Saleh M Harriman P Edwards D


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 977 - 982
1 Jul 2013
Wu AM Tian NF Wu LJ He W Ni WF Wang XY Xu HZ Chi YL

The purpose of this study was to determine whether it would be feasible to use oblique lumbar interbody fixation for patients with degenerative lumbar disease who required a fusion but did not have a spondylolisthesis.

A series of CT digital images from 60 patients with abdominal disease were reconstructed in three dimensions (3D) using Mimics v10.01: a digital cylinder was superimposed on the reconstructed image to simulate the position of an interbody screw. The optimal entry point of the screw and measurements of its trajectory were recorded. Next, 26 cadaveric specimens were subjected to oblique lumbar interbody fixation on the basis of the measurements derived from the imaging studies. These were then compared with measurements derived directly from the cadaveric vertebrae.

Our study suggested that it is easy to insert the screws for L1/2, L2/3 and L3/4 fixation: there was no significant difference in measurements between those of the 3-D digital images and the cadaveric specimens. For L4/5 fixation, part of L5 inferior articular process had to be removed to achieve the optimal trajectory of the screw. For L5/S1 fixation, the screw heads were blocked by iliac bone: consequently, the interior oblique angle of the cadaveric specimens was less than that seen in the 3D digital images.

We suggest that CT scans should be carried out pre-operatively if this procedure is to be adopted in clinical practice. This will assist in determining the feasibility of the procedure and will provide accurate information to assist introduction of the screws.

Cite this article: Bone Joint J 2013;95-B:977–82.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 126 - 130
1 Jan 2011
Bruins MJ Zwiers JH Verheyen CCPM Wolfhagen MJHM

Aspiration arthrography using an iodinated contrast medium is a useful tool for the investigation of septic or aseptic loosening of arthroplasties and of septic arthritis. Previously, the contrast media have been thought to cause false negative results in cultures when present in aspirated samples of synovial fluid, probably because free iodine is bactericidal, but reports have been inconclusive.

We examined the influence of the older, high osmolar contrast agents and the low osmolar media used currently on the growth of ten different micro-organisms capable of causing deep infection around a prosthesis. Five media were tested, using a disc diffusion technique and a time-killing curve method in which high and low inocula of micro-organisms were incubated in undiluted media. The only bactericidal effects were found with low inocula of Escherichia coli and Pseudomonas aeruginosa in ioxithalamate, one of the older ionic media.

The low and iso-osmolar iodinated contrast media used currently do not impede culture. Future study must assess other causes of false negative cultures of synovial fluid and new developments in enhancing microbial recovery from aspirated samples.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1234 - 1240
1 Sep 2012
Willcox NMJ Clarke JV Smith BRK Deakin AH Deep K

We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m2 (19 to 49). Pre-implant Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability coefficient of 9.0°. The Bland–Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0° to 5.4° with a repeatability coefficient of 5.2°. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees.

The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1454 - 1458
1 Nov 2009
Eswaramoorthy VK Biant LC Field RE

We report the outcome of total hip replacement in 29 failed metal-on-metal resurfacing hip replacements in which the primary surgery was performed between August 1995 and February 2005. The mean length of follow-up was five years (1.7 to 11.7). Of the 29 hip resurfacings, 19 acetabular components and all the femoral components were revised (28 uncemented stems and one cemented stem). There were no deaths and none of the patients was lost to follow-up. None of the hips underwent any further revision. The results of the revision resurfacing group were compared with those of a control group of age-matched patients. In the latter group there were 236 primary total hip replacements and 523 resurfacings performed during the same period by the same surgeons.

The outcome of the revision resurfacing group was comparable with that of the stemmed primary hip replacement group but was less good than that of the primary hip resurfacing group. Long-term follow-up is advocated to monitor the outcome of these cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 779 - 779
1 Jul 2003
Tillman RM


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1083 - 1083
1 Nov 1999
HEUREUX F DELGRANGE E DONCKIER J


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1247 - 1252
1 Sep 2011
Sinha A Edwin J Sreeharsha B Bhalaik V Brownson P

This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively.

An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle.