Advertisement for orthosearch.org.uk
Results 1 - 100 of 188
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1285 - 1289
1 Sep 2013
Inglis M McClelland B Sutherland LM Cundy PJ

Fractures of the forearm (radius or ulna or both) in children have traditionally been immobilised in plaster of Paris (POP) but synthetic cast materials are becoming more popular. There have been no randomised studies comparing the efficacy of these two materials. The aim of this study was to investigate which cast material is superior for the management of these fractures. We undertook a single-centre prospective randomised trial involving 199 patients with acute fractures of the forearm requiring general anaesthesia for reduction. Patients were randomised by sealed envelope into either a POP or synthetic group and then underwent routine closed reduction and immobilisation in a cast. The patients were reviewed at one and six weeks. A satisfaction questionnaire was completed following the removal of the cast. All clinical complications were recorded and the cast indices were calculated. There was an increase in complications in the POP group. These complications included soft areas of POP requiring revision and loss of reduction with some requiring re-manipulation. There was an increased mean padding index in the fractures that lost reduction. Synthetic casts were preferred by the patients. This study indicates that the clinical outcomes and patient satisfaction are superior using synthetic casts with no reduction in safety. Cite this article: Bone Joint J 2013;95-B:1285–9


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims. Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm. Methods. An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score. Results. Of the 18 patients (nine male, nine female) who met the inclusion criteria, the median follow-up was 8.5 years (interquartile range (IQR) 5.6 to 10). Their mean age was 49 years (SD 11). The mean extension improved significantly from 38° (SD 15°) to 24° (SD 9°) (p = 0.027), with a mean flexion-extension arc change from 81° (SD 27°) to 93° (SD 30°) (p = 0.172) but with no forearm rotational improvement (p = 0.233) at latest follow-up. The QuickDASH functional score improved significantly from 80 (SD 14) to 52 (SD 26) following reconstruction (p = 0.031), but generally the level of disability remains high. Radiological assessment showed no progression of proximal migration of the radius, with a stable interbutton distance and ulnar variance from immediate postoperative radiograph to the latest follow-up. Conclusion. Central band interosseus membrane reconstruction using a synthetic braided cross-linked graft can improve patient-rated arm function and range of motion, but significant functional deficits remain in patients with chronic injuries. Cite this article: Bone Joint J 2024;106-B(2):182–188


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1405 - 1411
3 Oct 2020
Martynov I Klink T Slowik V Stich R Zimmermann P Engel C Lacher M Boehm R

Aims. This exploratory randomized controlled trial (RCT) aimed to determine the splint-related outcomes when using the novel biodegradable wood-composite splint (Woodcast) compared to standard synthetic fibreglass (Dynacast) for the immobilization of undisplaced upper limb fractures in children. Methods. An exploratory RCT was performed at a tertiary paediatric referral hospital between 1 June 2018 and 30 September 2019. The intention-to-treat population consisted of 170 patients (mean age 8.42 years (SD 3.42); Woodcast (WCG), n = 84, 57 male (67.9%); Dynacast (DNG), n = 86, 58 male (67.4%)). Patients with undisplaced upper limb fractures were randomly assigned to WCG or DNG treatment groups. Primary outcome was the stress stability of the splint material, defined as absence of any deformations or fractures within the splint during study period. Secondary outcomes included patient satisfaction and medical staff opinion. Additionally, biomechanical and chemical analysis of the splint samples was carried out. Results. Of the initial 170 patients, 168 (98.8%) completed at least one follow-up, and were included for analysis of the primary endpoint. Both treatment groups were well-matched regarding to age, sex, and type and localization of the fracture. Splint breakage occurred in three patients (3.6%; 95% confidence interval (CI), 0.007% to 0.102%) in the WCG and in three children (3.5%, 95% CI 0.007% to 0.09%) in the DNG (p > 0.99). The incidence of splint-related adverse events did not differ between the WCG (n = 21; 25.0%) and DNG (n = 24; 27.9%; p = 0.720). Under experimental conditions, the maximal tensile strength of Dynacast samples was higher than those deriving from Woodcast (mean 15.37 N/mm² (SD 1.37) vs 10.75 N/mm² (SD 1.20); p = 0.002). Chemical analysis revealed detection of polyisocyanate-prepolymer in Dynacast and polyester in Woodcast samples. Conclusion. Splint-related adverse events appear similar between WCG and DNG treatment groups during the treatment of undisplaced forearm fractures. Cite this article: Bone Joint J 2020;102-B(10):1405–1411


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1657 - 1661
1 Dec 2015
Taranu R Rushton PRP Serrano-Pedraza I Holder L Wallace WA Candal-Couto JJ

Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer. Cite this article: Bone Joint J 2015;97-B:1657–61


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 258 - 264
1 Feb 2007
Nagura I Fujioka H Kokubu T Makino T Sumi Y Kurosaka M

We developed a new porous scaffold made from a synthetic polymer, poly(DL-lactide-co-glycolide) (PLG), and evaluated its use in the repair of cartilage. Osteochondral defects made on the femoral trochlear of rabbits were treated by transplantation of the PLG scaffold, examined histologically and compared with an untreated control group. Fibrous tissue was initially organised in an arcade array with poor cellularity at the articular surface of the scaffold. The tissue regenerated to cartilage at the articular surface. In the subchondral area, new bone formed and the scaffold was absorbed. The histological scores were significantly higher in the defects treated by the scaffold than in the control group (p < 0.05). Our findings suggest that in an animal model the new porous PLG scaffold is effective for repairing full-thickness osteochondral defects without cultured cells and growth factors


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 13 - 18
1 Jan 1998
Ransford AO Morley T Edgar MA Webb P Passuti N Chopin D Morin C Michel F Garin C Pries D

We have evaluated the use of a synthetic porous ceramic (Triosite) as a substitute for bone graft in posterior spinal fusion for idiopathic scoliosis. In a prospective, randomised study 341 patients at five hospitals in the UK and France were randomly allocated either to autograft from the iliac crest or rib segments (171) or to receive Triosite blocks (170). All patients were assessed after operation and at 3, 6, 12 and 18 months. The two groups were similar with regard to all demographic and baseline variables, but the 184 treated in France (54%) had Cotrel-Dubouset instrumentation and the 157 treated in the UK usually had Harrington-Luque implants. In the Triosite group the average Cobb angle of the upper curve was 56°, corrected to 24° (57%). At 18 months, the average was 26° (3% loss). In the autograft group the average preoperative upper curve of 53° was corrected to 21° (60%). At 18 months the mean curve was 25° (8% loss). Pain levels after operation were similar in the two groups, being mild in most cases. In the Triosite group only three patients had problems of wound healing, but in the autograft group, 14 patients had delayed healing, infection or haematoma in the spinal wound. In addition, 15 autograft patients had pain at the donor site at three months. Seven had infections, two had haematoma and four had delayed healing. The haematological and serum biochemistry results showed no abnormal trends and no significant differences between the groups. There were no adverse events related to the graft material and no evidence of allergenicity. Our results suggest that Triosite synthetic porous ceramic is a safe and effective substitute for autograft in these patients. Histological findings on biopsy indicate that Triosite provides a favourable scaffolding for the formation of new bone and is gradually incorporated into the fusion mass


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 617 - 623
1 May 2010
McNamara I Deshpande S Porteous M

The clinical and radiological results of 50 consecutive acetabular reconstructions in 48 patients using impaction grafting have been retrospectively reviewed. A 1:1 mixture of frozen, ground irradiated bone graft and Apapore 60, a synthetic bone graft substitute, was used in all cases. There were 13 complex primary and 37 revision procedures with a mean follow-up of five years (3.4 to 7.6). The clinical survival rate was 100%, with improvements in the mean Harris Hip Scores for pain and function. Radiologically, 30 acetabular grafts showed evidence of incorporation, ten had radiolucent lines and two acetabular components migrated initially before stabilising. Acetabular reconstruction in both primary and revision surgery using a 1:1 mixture of frozen, ground, irriadiated bone and Apapore 60 appears to be a reliable method of managing acetabular defects. Longer follow-up will be required to establish whether this technique is as effective as using fresh-frozen allograft


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1003 - 1007
1 Nov 1997
Oka M Chang Y Nakamura T Ushio K Toguchida J Gu H

We have studied damage to the tibial articular surface after replacement of the femoral surface in dogs. We inserted pairs of implants made of alumina, titanium and polyvinyl alcohol (PVA) hydrogel on titanium fibre mesh into the femoral condyles.

The two hard materials caused marked pathological changes in the articular cartilage and menisci, but the hydrogel composite replacement caused minimal damage. The composite osteochondral device became rapidly attached to host bone by ingrowth into the supporting mesh.

We discuss the clinical implications of the possible use of this material in articular resurfacing and joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 747 - 747
1 Jul 1998
MOLANO CB


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 592 - 596
1 Jul 1990
Bostman O Hirvensalo E Makinen J Rokkanen P

Biodegradable rods of polyglycolide or lactide-glycolide copolymer were used in the internal fixation of a variety of fractures and osteotomies in 516 patients. A clinically manifest foreign-body reaction occurred in 41 patients (7.9%), producing a fluctuant swelling at the implantation site after an average of 12 weeks. Spontaneous sinus formation or surgical drainage yielded a sterile exudate containing liquid remnants of the degrading implants. After prompt drainage this discharge subsided within three weeks. Histological examination showed a typical nonspecific foreign-body reaction with abundant giant cells both in patients with the reaction and in some patients with an uneventful clinical course. The factors determining the nature of the reaction were probably related to the local capacity of the tissues to clear the polymeric debris. The reactions did not influence the clinical or radiographic results, but recognition of the incidence and the features of the reaction is necessary in view of the increasing use of such implants.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 242 - 248
1 Feb 2022
Smolle MA Fischerauer SF Zötsch S Kiegerl AV Sadoghi P Gruber G Leithner A Bernhardt GA

Aims. The aim of this prospective study was to assess the long-term clinical, radiological, functional, and quality of life (QoL)-related outcome of patients treated with the synthetic Ligament Advanced Reinforcement System (LARS) device for anterior cruciate ligament (ACL) rupture. Methods. A total of 41 patients who underwent ACL reconstruction with the LARS device (mean age 39.8 years (SD 12.1 ); 32% females (n = 13)) were prospectively included between August 2001 and March 2005. MRI scans and radiographs were performed at a median follow-up of 2.0 years (interquartile range (IQR) 1.3 to 3.0; n = 40) and 12.8 years (IQR 12.1 to 13.8; n = 22). Functional and QoL-related outcome was assessed in 29 patients at a median follow-up of 12.8 years (IQR 12.0 to 14.0) and clinically reconfirmed at latest median follow-up of 16.5 years (IQR 15.5 to 17.9). International Knee Documentation Committee (IKDC) and Tegner scores were obtained pre- and postoperatively, and Lysholm score postoperatively only. At latest follow-up, range of motion, knee stability tests, 36-Item Short Form Health Survey (SF-36), and IKDC scores were ascertained. Complications and reoperations during follow-up were documented. Results. Cumulative complication rate was 66% (n = 27), with 11 developing within one year from surgery and 16 after one year (including five patients with both early and late complications). Ten graft failures (24%) and eight cases of reactive synovitis were observed (20%). All 11 patients with early complications and ten with late complications underwent reoperation (including five with another surgical procedure for early complications), amounting to a cumulative reoperation rate of 51% (n = 21). Revision ACL reconstruction was performed in one patient (2.4%). Median IKDC at latest follow-up was 89.7 (IQR 78.2 to 93.1), being significantly worse in the event of previous complications. Lachman test was positive in 56% (n = 15) of reconstructed knees. All norm-based SF-36 items were at or above median at latest follow-up, and did not differ depending on development of complications. Conclusion. Despite good functional and QoL-related results in the long term, the cumulative complication rate of 66%, including graft failures and reactive synovitis, has to be viewed with great concern. Cite this article: Bone Joint J 2022;104-B(2):242–248


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims. To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. . Patients and Methods. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (. sd. ) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. . Results. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). Conclusion. In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. . Take home message: Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Cite this article: Bone Joint J 2016;98-B:512–18


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 713 - 718
1 May 2012
Kaiser MM Zachert G Wendlandt R Eggert R Stratmann C Gros N Schulze-Hessing M Rapp M

Elastic stable intramedullary nailing (ESIN) is generally acknowledged to be the treatment of choice for displaced diaphyseal femoral fractures in children over the age of three years, although complication rates of up to 50% are described. Pre-bending the nails is recommended, but there are no published data to support this. Using synthetic bones and a standardised simulated fracture, we performed biomechanical testing to determine the influence on the stability of the fracture of pre-bending the nails before implantation. Standard ESIN was performed on 24 synthetic femoral models with a spiral fracture. In eight cases the nails were inserted without any pre-bending, in a further eight cases they were pre-bent to 30° and in the last group of eight cases they were pre-bent to 60°. Mechanical testing revealed that pre-bending to 60° produced a significant increase in the stiffness or stability of the fracture. Pre-bending to 60° showed a significant positive influence on the stiffness compared with unbent nails. Pre-bending to 30° improved stiffness only slightly. These findings validate the recommendations for pre-bending, but the degree of pre-bend should exceed 30°. Adopting higher degrees of pre-bending should improve stability in spiral fractures and reduce the complications of varus deformity and shortening


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims

Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries.

Methods

A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 531 - 537
1 Apr 2017
Henderson ER Keeney BJ Pala E Funovics PT Eward WC Groundland JS Ehrlichman LK Puchner SSE Brigman BE Ready JE Temple HT Ruggieri P Windhager R Letson GD Hornicek FJ

Aims. Instability of the hip is the most common mode of failure after reconstruction with a proximal femoral arthroplasty (PFA) using an endoprosthesis after excision of a tumour. Small studies report improved stability with capsular repair of the hip and other techniques, but these have not been investigated in a large series of patients. The aim of this study was to evaluate variables associated with the patient and the operation that affect post-operative stability. We hypothesised an association between capsular repair and stability. Patients and Methods. In a retrospective cohort study, we identified 527 adult patients who were treated with a PFA for tumours. Our data included demographics, the pathological diagnosis, the amount of resection of the abductor muscles, the techniques of reconstruction and the characteristics of the implant. We used regression analysis to compare patients with and without post-operative instability. Results. A total of 20 patients out of 527 (4%) had instability which presented at a mean of 35 days (3 to 131) post-operatively. Capsular repair was not associated with a reduced rate of instability. Bivariate analysis showed that a posterolateral surgical approach (odds ratio (OR) 0.11, 95% confidence interval (CI) 0.02 to 0.86) and the type of implant (p = 0.046) had a significant association with reduced instability; age > 60 years predicted instability (OR 3.17, 95% CI 1.00 to 9.98). Multivariate analysis showed age > 60 years (OR 5.09, 95% CI 1.23 to 21.07), female gender (OR 1.73, 95% CI 1.04 to 2.89), a malignant primary bone tumour (OR 2.04, 95% CI 1.06 to 3.95), and benign condition (OR 5.56, 95% CI 1.35 to 22.90), but not metastatic disease or soft-tissue tumours, predicted instability, while a posterolateral approach (OR 0.09, 95% CI 0.01 to 0.53) was protective against instability. No instability occurred when a synthetic graft was used in 70 patients. Conclusion. Stability of the hip after PFA is influenced by variables associated with the patient, the pathology, the surgical technique and the implant. We did not find an association between capsular repair and improved stability. Extension of the tumour often dictates surgical technique; however, our results indicate that PFA using a posterolateral approach with a hemiarthroplasty and synthetic augment for soft-tissue repair confers the lowest risk of instability. Patients who are elderly, female, or with a primary benign or malignant bone tumour should be counselled about an increased risk of instability. Cite this article: Bone Joint J 2017;99-B:531–7


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 623 - 630
1 Jun 2024
Perry DC Dritsaki M Achten J Appelbe D Knight R Widnall J Roland D Messahel S Costa ML Mason J

Aims

The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius.

Methods

A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of ‘willingness-to-pay’ thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 632 - 638
1 Jun 2024
Hart CM Kelley BV Mamouei Z Turkmani A Ralston M Arnold M Bernthal NM Sassoon AA

Aims

Delayed postoperative inoculation of orthopaedic implants with persistent wound drainage or bacterial seeding of a haematoma can result in periprosthetic joint infection (PJI). The aim of this in vivo study was to compare the efficacy of vancomycin powder with vancomycin-eluting calcium sulphate beads in preventing PJI due to delayed inoculation.

Methods

A mouse model of PJI of the knee was used. Mice were randomized into groups with intervention at the time of surgery (postoperative day (POD) 0): a sterile control (SC; n = 6); infected control (IC; n = 15); systemic vancomycin (SV; n = 9); vancomycin powder (VP; n = 21); and vancomycin bead (VB; n = 19) groups. Delayed inoculation was introduced during an arthrotomy on POD 7 with 1 × 105 colony-forming units (CFUs) of a bioluminescent strain of Staphylococcus aureus. The bacterial burden was monitored using bioluminescence in vivo. All mice were killed on POD 21. Implants and soft-tissue were harvested and sonicated for analysis of the CFUs.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 261 - 268
1 Mar 2023
Ruhr M Huber G Niki Y Lohner L Ondruschka B Morlock MM

Aims

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure.

Methods

Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 696 - 704
1 Jul 2024
Barvelink B Reijman M Smidt S Miranda Afonso P Verhaar JAN Colaris JW

Aims

It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer fracture redisplacements and better one-year outcomes compared to plaster splinting.

Methods

In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1595 - 1602
1 Dec 2013
Modi CS Beazley J Zywiel MG Lawrence TM Veillette CJH

The aim of this review is to address controversies in the management of dislocations of the acromioclavicular joint. Current evidence suggests that operative rather than non-operative treatment of Rockwood grade III dislocations results in better cosmetic and radiological results, similar functional outcomes and longer time off work. Early surgery results in better functional and radiological outcomes with a reduced risk of infection and loss of reduction compared with delayed surgery. Surgical options include acromioclavicular fixation, coracoclavicular fixation and coracoclavicular ligament reconstruction. Although non-controlled studies report promising results for arthroscopic coracoclavicular fixation, there are no comparative studies with open techniques to draw conclusions about the best surgical approach. Non-rigid coracoclavicular fixation with tendon graft or synthetic materials, or rigid acromioclavicular fixation with a hook plate, is preferable to fixation with coracoclavicular screws owing to significant risks of loosening and breakage. The evidence, although limited, also suggests that anatomical ligament reconstruction with autograft or certain synthetic grafts may have better outcomes than non-anatomical transfer of the coracoacromial ligament. It has been suggested that this is due to better restoration horizontal and vertical stability of the joint. Despite the large number of recently published studies, there remains a lack of high-quality evidence, making it difficult to draw firm conclusions regarding these controversial issues. Cite this article: Bone Joint J 2013;95-B:1595–1602


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 215 - 219
1 Feb 2023
Buchan SJ Lindisfarne EA Stabler A Barry M Gent ED Bennet S Aarvold A

Aims

Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide.

Methods

All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 474 - 480
1 May 2023
Inclan PM Brophy RH

Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral extra-articular augmentation, and/or osteotomy. Although revision ACLr reliably restores knee stability and function, clinical outcomes and reoperation rates are worse than for primary ACLr.

Cite this article: Bone Joint J 2023;105-B(5):474–480.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 516 - 521
1 Jun 2024
Al-Hourani K Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 59 - 65
1 May 2024
Liu WKT Cheung A Fu H Chan PK Chiu KY

Aims

Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.

Methods

Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 688 - 695
1 Jul 2024
Farrow L Zhong M Anderson L

Aims

To examine whether natural language processing (NLP) using a clinically based large language model (LLM) could be used to predict patient selection for total hip or total knee arthroplasty (THA/TKA) from routinely available free-text radiology reports.

Methods

Data pre-processing and analyses were conducted according to the Artificial intelligence to Revolutionize the patient Care pathway in Hip and knEe aRthroplastY (ARCHERY) project protocol. This included use of de-identified Scottish regional clinical data of patients referred for consideration of THA/TKA, held in a secure data environment designed for artificial intelligence (AI) inference. Only preoperative radiology reports were included. NLP algorithms were based on the freely available GatorTron model, a LLM trained on over 82 billion words of de-identified clinical text. Two inference tasks were performed: assessment after model-fine tuning (50 Epochs and three cycles of k-fold cross validation), and external validation.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims

There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation.

Methods

We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75).


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1339 - 1347
1 Oct 2013
Scott CEH Eaton MJ Nutton RW Wade FA Pankaj P Evans SL

As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves (‘hits’) produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint. . Cite this article: Bone Joint J 2013;95-B:1339–47


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 529 - 531
1 May 2022
Rajput V Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 958 - 965
1 Jul 2008
Leong JJH Leff DR Das A Aggarwal R Reilly P Atkinson HDE Emery RJ Darzi AW

The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device. The video scores were significantly different for the three groups in all three procedures (p < 0.05), with excellent inter-rater reliability (α = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p < 0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p > 0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment. This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 786 - 791
1 Jul 2022
Jenkinson MRJ Peeters W Hutt JRB Witt JD

Aims

Acetabular retroversion is a recognized cause of hip impingement and can be influenced by pelvic tilt (PT), which changes in different functional positions. Positional changes in PT have not previously been studied in patients with acetabular retroversion.

Methods

Supine and standing anteroposterior (AP) pelvic radiographs were retrospectively analyzed in 69 patients treated for symptomatic acetabular retroversion. Measurements were made for acetabular index (AI), lateral centre-edge angle (LCEA), crossover index, ischial spine sign, and posterior wall sign. The change in the angle of PT was measured both by the sacro-femoral-pubic (SFP) angle and the pubic symphysis to sacroiliac (PS-SI) index.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1227 - 1231
1 Sep 2009
Abuhassan FO Shannak AO

We describe the treatment by subperiosteal resection of an aneurysmal bone cyst in the distal fibula in eight patients and highlight the role of the periosteum in the regeneration of bone defects. The mean age of the patients was 13.5 years (12 to 17). Seven had an open growth plate. The mean size of the resected specimen was 5.12 cm (3.5 to 8.0). None of the patients received instillation of bone marrow, autogenous bone graft, allograft or any synthetic bone substitutes. All had complete regeneration of the bone defect within three to nine months, with no joint instability or recurrence. The mean length of follow-up was 11.5 years (2 to 18). At the final follow-up there was no difference in the range of movement, alignment or stability of the ankle when compared with the opposite side. The periosteum played a major role in the complete filling of the bone defects and avoided the morbidity of other techniques


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims

Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided.

Methods

This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model. A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads. All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (. sd. 1500), 28 800 cycles (. sd.  6300), and 26 400 cycles (. sd. 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (. sd. 10 700), 36 000 cycles (. sd. 7200), and 36 600 cycles (. sd.  10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution. In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 401 - 408
1 May 1968
Prasad GC Reynolds JJ

1. The use of a protein-free synthetic medium has provided a new technical approach to the study of fracture healing in vitro. 2. The tibiae of fourteen-day embryonic chicks were cut in half in the middle of the shaft, the fragments were placed in apposition and the explants grown in vitro for up to sixteen days. The process of bone repair was studied by means of histology and biochemical estimations. 3. The rate of growth in length of fractured bones was greater in an atmosphere containing 50 per cent of oxygen than in one with 20 per cent oxygen, thus emphasising the importance of an adequate oxygen supply for the regeneration of osteogenic cells. 4. The effect of varying the concentration of glucose in the medium was investigated. Two milligrams of glucose per millilitre was the most favourable for healing; higher levels caused fibroblastic changes in the cartilage cells and inhibited the proliferation of osteogenic cells at the fracture site. 5. Histological examination showed that many of the phenomena that occur in the repair of fractures in vivo can be reproduced in vitro in synthetic medium. Similar results were obtained whether the fracture was made in whole bones or in isolated shafts from which the cartilaginous ends had been removed; the latter are more favourable for biochemical study


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 939 - 945
1 May 2021
Kakar S Logli AL Ramazanian T Gaston RG Fowler JR

Aims

The purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability.

Methods

We studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims

The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols.

Methods

A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.


Aims

The study was undertaken to compare the efficacy of Woodcast splints and plaster-of-Paris casts in maintaining correction following sequential manipulation of idiopathic clubfeet.

Methods

In this randomized prospective trial, 23 idiopathic clubfeet were immobilized with plaster-of-Paris casts and 23 clubfeet were immobilized with a splint made of Woodcast that encircled only two-thirds the circumference of the limb. The number of casts or splints needed to obtain full correction, the frequency of cast or splint-related complications, and the time taken for application and removal of the casts and splints were compared.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 442 - 448
1 Mar 2021
Nikolaou VS Masouros P Floros T Chronopoulos E Skertsou M Babis GC

Aims

The aim of this study was to investigate the hypothesis that a single dose of tranexamic acid (TXA) would reduce blood loss and transfusion rates in elderly patients undergoing surgery for a subcapital or intertrochanteric (IT) fracture of the hip.

Methods

In this single-centre, randomized controlled trial, elderly patients undergoing surgery for a hip fracture, either hemiarthroplasty for a subcapital fracture or intramedullary nailing for an IT fracture, were screened for inclusion. Patients were randomly allocated to a study group using a sealed envelope. The TXA group consisted of 77 patients, (35 with a subcapital fracture and 42 with an IT fracture), and the control group consisted of 88 patients (29 with a subcapital fracture and 59 with an IT fracture). One dose of 15 mg/kg of intravenous (IV) TXA diluted in 100 ml normal saline (NS,) or one dose of IV placebo 100 ml NS were administered before the incision was made. The haemoglobin (Hb) concentration was measured before surgery and daily until the fourth postoperative day. The primary outcomes were the total blood loss and the rate of transfusion from the time of surgery to the fourth postoperative day.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 43 - 48
1 Jun 2020
D’Lima DP Huang P Suryanarayan P Rosen A D’Lima DD

Aims

The extensive variation in axial rotation of tibial components can lead to coronal plane malalignment. We analyzed the change in coronal alignment induced by tray malrotation.

Methods

We constructed a computer model of knee arthroplasty and used a virtual cutting guide to cut the tibia at 90° to the coronal plane. The virtual guide was rotated axially (15° medial to 15° lateral) and with posterior slopes (0° to 7°). To assess the effect of axial malrotation, we measured the coronal plane alignment of a tibial tray that was axially rotated (25° internal to 15° external), as viewed on a standard anteroposterior (AP) radiograph.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 469 - 478
1 Mar 2021
Garland A Bülow E Lenguerrand E Blom A Wilkinson M Sayers A Rolfson O Hailer NP

Aims

To develop and externally validate a parsimonious statistical prediction model of 90-day mortality after elective total hip arthroplasty (THA), and to provide a web calculator for clinical usage.

Methods

We included 53,099 patients with cemented THA due to osteoarthritis from the Swedish Hip Arthroplasty Registry for model derivation and internal validation, as well as 125,428 patients from England and Wales recorded in the National Joint Register for England, Wales, Northern Ireland, the Isle of Man, and the States of Guernsey (NJR) for external model validation. A model was developed using a bootstrap ranking procedure with a least absolute shrinkage and selection operator (LASSO) logistic regression model combined with piecewise linear regression. Discriminative ability was evaluated by the area under the receiver operating characteristic curve (AUC). Calibration belt plots were used to assess model calibration.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 88 - 91
1 Jan 1991
Wytch R Ashcroft G Ledingham W Wardlaw D Ritchie I

We have assessed the current range of synthetic splinting bandages, using physical and mechanical tests and the subjective opinions of patients, volunteers and orthopaedic staff. Modern bandages have some better properties than standard plaster bandage but do not conform as well, are more expensive, and potentially more hazardous


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 3 | Pages 392 - 398
1 Aug 1951
Newman PH Scales JT

In addition to its orthopaedic interest, this case illustrates the special behaviour of fine particles of a synthetic material when implanted in the human body. These results may interest those engaged in the control of dusts in the plastics industry, for the inhalation of such dusts may well result in "implantation" of the material in the lung, with consequent histological changes


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 1 | Pages 100 - 103
1 Feb 1965
Gleave JAE

1. This is a report on the production of sockets for above-knee prostheses utilising a composite laminate of synthetic and natural materials and using a principle of total stump contact with the socket, which before fitting is shaped to suit individual stump contours. 2. A new method of taking casts is described, as is the production of the socket, and observations on the use of the prosthesis over the last two and a half years are made


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 907 - 908
1 Sep 1998
Hutchinson JW Tierney GM Parsons SL Davis TRC

In a series of 12 patients with inoperable gastric carcinoma who had treatment with a synthetic matrix metalloproteinase inhibitor (Marimastat) for more than one month, six developed a frozen shoulder or a condition resembling Dupuytren’s disease. This suggests that the matrix metalloproteinases, a family of naturally occurring proteinases, may be involved in the pathogenesis of these two conditions. Our observation opens avenues for further research which could lead to local or systemic therapeutic interventions for frozen shoulder and Dupuytren’s disease


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 379 - 382
1 May 1989
Martini A Fromm B

A stump neuroma is caused by the disorganised growth of axon cylinders into proliferating granulation tissue, but this is stopped by an undamaged epineural sleeve. We report experiments in the rat in which the epineural sleeve of the stump of the sciatic nerve was freed from nerve fascicles for about 5 mm and then sealed with a synthetic tissue adhesive. Neuroma formation was largely prevented in comparison with the results of other methods. This new technique has been used to treat 68 painful neuromas in 36 patients. All but three of the patients were cured or improved and none were made worse


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 126 - 134
1 Jan 2004
Clarke SA Brooks RA Lee PT Rushton N

Synthetic bone substitutes provide an alternative to autograft but do not give equivalent clinical results. Their performance may be enhanced by adding osteogenic growth factors. In this study, TGFβ1 was absorbed on to a carrier of β tricalcium phosphate and Gelfoam® and used to fill a defect around a tibial implant in a rat model of revision arthoplasty. We added 0.0, 0.02 μg, 0.1 μg or 1.0 μg of TGFβ1 to the carrier and then implanted it around an hydroxyapatite-coated stainless-steel pin in the proximal tibia of rats. The tibiae were harvested at three, six or 26 weeks and the amount of bone formation and ceramic resorption were assessed. TGFβ1 had no effect on the amount of bone in the defect, the amount of fluorescent label incorporated or the rate of mineral apposition. The growth factor did not significantly affect the amount of β TCP remaining in the tissue at any of the time points


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1257 - 1263
1 Sep 2006
Richter M Droste P Goesling T Zech S Krettek C

Different calcaneal plates with locked screws were compared in an experimental model of a calcaneal fracture. Four plate models were tested, three with uniaxially-locked screws (Synthes, Newdeal, Darco), and one with polyaxially-locked screws (90° ± 15°) (Rimbus). Synthetic calcanei were osteotomised to create a fracture model and then fixed with the plates and screws. Seven specimens for each plate model were subjected to cyclic loading (preload 20 N, 1000 cycles at 800 N, 0.75 mm/s), and load to failure (0.75 mm/s). During cyclic loading, the plate with polyaxially-locked screws (Rimbus) showed significantly lower displacement in the primary loading direction than the plates with uniaxially-locked screws (mean values of maximum displacement during cyclic loading: Rimbus, 3.13 mm (. sd. 0.68); Synthes, 3.46 mm (. sd. 1.25); Darco, 4.48 mm (. sd. 3.17); Newdeal, 5.02 mm (. sd. 3.79); one-way analysis of variance, p < 0.001). The increased stability of a plate with polyaxially-locked screws demonstrated during cyclic loading compared with plates with uniaxially-locked screws may be beneficial for clinical use


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1238 - 1247
1 Oct 2019
Soreide E Denbeigh JM Lewallen EA Thaler R Xu W Berglund L Yao JJ Martinez A Nordsletten L van Wijnen AJ Kakar S

Aims

Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function.

Materials and Methods

A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6).


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1151 - 1157
14 Sep 2020
Levack AE McLawhorn AS Dodwell E DelPizzo K Nguyen J Sink E

Aims

Tranexamic acid (TXA) has been shown to reduce blood loss and transfusion requirements in patients undergoing orthopaedic surgery. There remains a lack of prospective evidence for the use of TXA in patients undergoing periacetabular osteotomy (PAO). The purpose of this study was to determine if intravenous (IV) TXA is effective in reducing calculated blood loss and transfusions after PAO.

Methods

This was a single-centre prospective double-blind placebo-controlled randomized trial of 81 patients aged 12 to 45 years undergoing elective PAO by a single surgeon. The intervention group (n = 40) received two doses of IV TXA of a maximum 1 g in each dose; the control group (n = 41) received two doses of 50 ml 0.9% saline IV. The primary outcome was perioperative calculated blood loss. Secondary outcomes included allogenic transfusions and six-week postoperative complications.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 151 - 157
1 Jun 2020
Gil D Atici AE Connolly RL Hugard S Shuvaev S Wannomae KK Oral E Muratoglu OK

Aims

We propose a state-of-the-art temporary spacer, consisting of a cobalt-chrome (CoCr) femoral component and a gentamicin-eluting ultra-high molecular weight polyethylene (UHMWPE) tibial insert, which can provide therapeutic delivery of gentamicin, while retaining excellent mechanical properties. The proposed implant is designed to replace conventional spacers made from bone cement.

Methods

Gentamicin-loaded UHMWPE was prepared using phase-separated compression moulding, and its drug elution kinetics, antibacterial, mechanical, and wear properties were compared with those of conventional gentamicin-loaded bone cement.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1585 - 1592
1 Dec 2019
Logishetty K Rudran B Cobb JP

Aims

Arthroplasty skills need to be acquired safely during training, yet operative experience is increasingly hard to acquire by trainees. Virtual reality (VR) training using headsets and motion-tracked controllers can simulate complex open procedures in a fully immersive operating theatre. The present study aimed to determine if trainees trained using VR perform better than those using conventional preparation for performing total hip arthroplasty (THA).

Patients and Methods

A total of 24 surgical trainees (seven female, 17 male; mean age 29 years (28 to 31)) volunteered to participate in this observer-blinded 1:1 randomized controlled trial. They had no prior experience of anterior approach THA. Of these 24 trainees, 12 completed a six-week VR training programme in a simulation laboratory, while the other 12 received only conventional preparatory materials for learning THA. All trainees then performed a cadaveric THA, assessed independently by two hip surgeons. The primary outcome was technical and non-technical surgical performance measured by a THA-specific procedure-based assessment (PBA). Secondary outcomes were step completion measured by a task-specific checklist, error in acetabular component orientation, and procedure duration.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 699 - 708
1 Jun 2020
Nieuwenhuijse MJ Vehmeijer SBW Mathijsen NMC Keizer SB

Aims

Short, bone-conserving femoral components are increasingly used in total hip arthroplasty (THA). They are expected to allow tissue-conserving implantation and to render future revision surgery more straightforward but the long-term data on such components is limited. One such component is the global tissue-sparing (GTS) stem. Following the model for stepwise introduction of new orthopaedic implants, we evaluated early implant fixation and clinical outcome of this novel short-stem THA and compared it to that of a component with established good long-term clinical outcome.

Methods

In total, 50 consecutive patients ≤ 70 years old with end-stage symptomatic osteo-arthritis were randomized to receive THA with the GTS stem or the conventional Taperloc stem using the anterior supine intermuscular approach by two experienced hip surgeons in two hospitals in the Netherlands. Primary outcome was implant migration. Patients were followed using routine clinical examination, patient reported outcome using Harris Hip Score (HHS), Hip Disability And Osteoarthritis Outcome Score (HOOS), EuroQol five-dimension questionnaire (EQ5D), and Roentgen Stereophotogrammetric Analysis (RSA) at three, six, 12, and 24 months. This study evaluated the two-year follow-up results.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 524 - 529
1 Apr 2020
Jamshidi K Mirkazemi M Gharedaghi M Izanloo A Mohammadpour M Pisoudeh K Bagherifard A Mirzaei A

Aims

The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis composite (APC) reconstruction of the proximal femur following primary tumour resection provides more stability than total hip arthroplasty (THA). However, no comparative study has been performed. In this study, we have compared the outcome and complication rates of these two methods.

Methods

In a retrospective study, 57 patients who underwent APC reconstruction of proximal femur following the primary tumour resection, either using BHA (29) or THA (28), were included. Functional outcome was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and Harris Hip Score (HHS). Postoperative complications of the two techniques were also compared.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 371 - 375
1 Mar 2020
Cawley D Dhokia R Sales J Darwish N Molloy S

With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety.

Cite this article: Bone Joint J 2020;102-B(3):371–375.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 512 - 521
1 May 2019
Carter TH Duckworth AD White TO

Abstract

The medial malleolus, once believed to be the primary stabilizer of the ankle, has been the topic of conflicting clinical and biomechanical data for many decades. Despite the relevant surgical anatomy being understood for almost 40 years, the optimal treatment of medial malleolar fractures remains unclear, whether the injury occurs in isolation or as part of an unstable bi- or trimalleolar fracture configuration. Traditional teaching recommends open reduction and fixation of medial malleolar fractures that are part of an unstable injury. However, there is recent evidence to suggest that nonoperative management of well-reduced fractures may result in equivalent outcomes, but without the morbidity associated with surgery. This review gives an update on the relevant anatomy and classification systems for medial malleolar fractures and an overview of the current literature regarding their management, including surgical approaches and the choice of implants.

Cite this article: Bone Joint J 2019;101-B:512–521.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1093 - 1099
1 Sep 2019
Bradley KE Ryan SP Penrose CT Grant SA Wellman SS Attarian DE Green CL Risoli T Bolognesi MP

Aims

Antifibrinolytic agents, including tranexamic acid (TXA) and epsilon-aminocaproic acid (EACA), have been shown to be safe and effective for decreasing perioperative blood loss and transfusion following total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, there are few prospective studies that directly compare these agents. The purpose of this study was to compare the benefits of intraoperative intravenous TXA with EACA.

Patients and Methods

A total of 235 patients (90 THA and 145 TKA) were enrolled in this prospective, randomized controlled trial at a single tertiary-care referral centre. In the THA cohort, 53.3% of the patients were female with a median age of 59.8 years (interquartile range (IQR) 53.3 to 68.1). In the TKA cohort, 63.4% of the patients were female with a median age of 65.1 years (IQR 59.4 to 69.5). Patients received either TXA (n = 119) or EACA (n = 116) in two doses intraoperatively. The primary outcome measures included change in haemoglobin level and blood volume, postoperative drainage, and rate of transfusion. Secondary outcome measures included postoperative complications, cost, and length of stay (LOS).


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 68 - 76
1 Jun 2019
Jones CW Choi DS Sun P Chiu Y Lipman JD Lyman S Bostrom MPG Sculco PK

Aims

Custom flange acetabular components (CFACs) are a patient-specific option for addressing large acetabular defects at revision total hip arthroplasty (THA), but patient and implant characteristics that affect survivorship remain unknown. This study aimed to identify patient and design factors related to survivorship.

Patients and Methods

A retrospective review of 91 patients who underwent revision THA using 96 CFACs was undertaken, comparing features between radiologically failed and successful cases. Patient characteristics (demographic, clinical, and radiological) and implant features (design characteristics and intraoperative features) were collected. There were 74 women and 22 men; their mean age was 62 years (31 to 85). The mean follow-up was 24.9 months (sd 27.6; 0 to 116). Two sets of statistical analyses were performed: 1) univariate analyses (Pearson’s chi-squared and independent-samples Student’s t-tests) for each feature; and 2) bivariable logistic regressions using features identified from a random forest analysis.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 296 - 302
1 Mar 2018
Sprowson† AP Jensen C Parsons N Partington P Emmerson K Carluke I Asaad S Pratt R Muller S Ahmed I Reed MR

Aims

Surgical site infection (SSI) is a common complication of surgery with an incidence of about 1% in the United Kingdom. Sutures can lead to the development of a SSI, as micro-organisms can colonize the suture as it is implanted. Triclosan-coated sutures, being antimicrobical, were developed to reduce the rate of SSI. Our aim was to assess whether triclosan-coated sutures cause a reduction in SSIs following arthroplasty of the hip and knee.

Patients and Methods

This two-arm, parallel, double-blinded study involved 2546 patients undergoing elective total hip (THA) and total knee arthroplasty (TKA) at three hospitals. A total of 1323 were quasi-randomized to a standard suture group, and 1223 being quasi-randomized to the triclosan-coated suture group. The primary endpoint was the rate of SSI at 30 days postoperatively.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 288 - 296
1 Mar 2019
Sigmund IK Holinka J Sevelda F Staats K Heisinger S Kubista B McNally MA Windhager R

Aims

This study aimed to assess the performance of an automated multiplex polymerase chain reaction (mPCR) technique for rapid diagnosis of native joint septic arthritis

Patients and Methods

Consecutive patients with suspected septic arthritis undergoing aseptic diagnostic joint aspiration were included. The aspirate was used for analysis by mPCR and conventional microbiological analysis. A joint was classed as septic according to modified Newman criteria. Based on receiver operating characteristic (ROC) analysis, the area under the ROC curve (AUC) values of the mPCR and the synovial fluid culture were compared using the z-test. A total of 72 out of 76 consecutive patients (33 women, 39 men; mean age 64 years (22 to 92)) with suspected septic arthritis were included in this study.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 207 - 212
1 Feb 2019
Clavé A Gérard R Lacroix J Baynat C Danguy des Déserts M Gatineau F Mottier D

Aims

Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol versus the long protocol.

Patients and Methods

A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The efficacy of short- and long-TXA protocols in the reduction of perioperative RBL was compared with a placebo group.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1559 - 1564
1 Dec 2018
McConnell JS Saunders PRJ Young SK

Aims

Cementless femoral stems must be correctly sized and well-seated to obtain satisfactory biological fixation. The change in sound that occurs during impaction of the femoral broach is said to indicate good fit, but this has not been widely studied. We set out to find whether the presence or absence of these sound changes could predict correct sizing.

Patients and Methods

We recorded the sound generated during femoral broaching for 105 cementless total hip arthroplasties using the Corail stem. Four cases were excluded, leaving 101 recordings for analysis. There were 36 male patients and 65 female patients, with a mean age of 69.9 years (sd 12.3) and median body mass index (BMI) of 29 kg/m2 (interquartile range (IQR) 26 to 32). The recordings were analyzed to identify the frequencies of the sounds produced during impaction of the femoral broach.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims

The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure.

Patients and Methods

A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1175 - 1181
1 Sep 2018
Benca E Willegger M Wenzel F Hirtler L Zandieh S Windhager R Schuh R

Aims

The traditional transosseus flexor hallucis longus (FHL) tendon transfer for patients with Achilles tendinopathy requires two incisions to harvest a long tendon graft. The use of a bio-tenodesis screw enables a short graft to be used and is less invasive, but lacks supporting evidence about its biomechanical behaviour. We aimed, in this study, to compare the strength of the traditional transosseus tendon-to-tendon fixation with tendon-to-bone fixation using a tenodesis screw, in cyclical loading and ultimate load testing.

Materials and Methods

Tendon grafts were undertaken in 24 paired lower-leg specimens and randomly assigned in two groups using fixation with a transosseus suture (suture group) or a tenodesis screw (screw group). The biomechanical behaviour was evaluated using cyclical and ultimate loading tests. The Student’s t-test was performed to assess statistically significant differences in bone mineral density (BMD), displacement, the slope of the load-displacement curves, and load to failure.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 271 - 284
1 Mar 2018
Hexter AT Thangarajah T Blunn G Haddad FS

Aims

The success of anterior cruciate ligament reconstruction (ACLR) depends on osseointegration at the graft-tunnel interface and intra-articular ligamentization. Our aim was to conduct a systematic review of clinical and preclinical studies that evaluated biological augmentation of graft healing in ACLR.

Materials and Methods

In all, 1879 studies were identified across three databases. Following assessment against strict criteria, 112 studies were included (20 clinical studies; 92 animal studies).


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 867 - 874
1 Jul 2018
Makarewich CA Anderson MB Gililland JM Pelt CE Peters CL

Aims

For this retrospective cohort study, patients aged ≤ 30 years (very young) who underwent total hip arthroplasty (THA) were compared with patients aged ≥ 60 years (elderly) to evaluate the rate of revision arthroplasty, implant survival, the indications for revision, the complications, and the patient-reported outcomes.

Patients and Methods

We retrospectively reviewed all patients who underwent primary THA between January 2000 and May 2015 from our institutional database. A total of 145 very young and 1359 elderly patients were reviewed. The mean follow-up was 5.3 years (1 to 18). Logistic generalized estimating equations were used to compare characteristics and the revision rate. Survival was evaluated using Kaplan–Meier curves and hazard rates were created using Cox regression.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 455 - 460
1 Apr 2018
Mumith A Thomas M Shah Z Coathup M Blunn G

Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research.

This review describes the current position in the use of additive manufacturing in orthopaedic surgery.

Cite this article: Bone Joint J 2018;100-B:455-60.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 558 - 563
1 Apr 2015
Windolf M Fischer MF Popp AW Matthys R Schwieger K Gueorguiev B Hunter JB Slongo TF

End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure.

Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°.

In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007).

These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push–out can be effectively reduced by the use of end caps.

Cite this article: Bone Joint J 2015;97-B:558–63.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1073 - 1079
1 Aug 2017
Pauzenberger L Domej MA Heuberer PR Hexel M Grieb A Laky B Blasl J Anderl W

Aims

The purpose of the present study was to evaluate the impact of intravenous tranexamic acid on the reduction of blood loss, transfusion rate, and early post-operative clinical outcome in total shoulder arthroplasty.

Patients and Methods

A randomised, placebo-controlled trial which included 54 patients undergoing unilateral primary stemless anatomical or stemmed reverse total shoulder arthroplasty was undertaken. Patients received either 100 ml saline (placebo, n = 27), or 100 ml saline together with 1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to skin incision and during wound closure. Peri-operative blood loss via an intra-articular drain was recorded and total blood loss was calculated. The post-operative transfusion rate was documented. Assessment of early clinical parameters included the visual analogue scale for pain (VAS), documentation of haematoma formation and adverse events.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1248 - 1252
1 Sep 2016
White TO Bugler KE Appleton P Will† E McQueen MM Court-Brown CM

Aims

The fundamental concept of open reduction and internal fixation (ORIF) of ankle fractures has not changed appreciably since the 1960s and, whilst widely used, is associated with complications including wound dehiscence and infection, prominent hardware and failure. Closed reduction and intramedullary fixation (CRIF) using a fibular nail, wires or screws is biomechanically stronger, requires minimal incisions, and has low-profile hardware. We hypothesised that fibular nailing in the elderly would have similar functional outcomes to standard fixation, with a reduced rate of wound and hardware problems.

Patients and Methods

A total of 100 patients (25 men, 75 women) over the age of 65 years with unstable ankle fractures were randomised to undergo standard ORIF or fibular nailing (11 men and 39 women in the ORIF group, 14 men and 36 women in the fibular nail group). The mean age was 74 years (65 to 93) and all patients had at least one medical comorbidity. Complications, patient related outcome measures and cost-effectiveness were assessed over 12 months.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius.

We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs).

The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs).

The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques.

However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed.

Cite this article: Bone Joint J 2015;97-B:1370–6.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1063 - 1069
1 Aug 2015
Pilge H Holzapfel BM Rechl H Prodinger PM Lampe R Saur U Eisenhart-Rothe R Gollwitzer H

The aim of this study was to analyse the gait pattern, muscle force and functional outcome of patients who had undergone replacement of the proximal tibia for tumour and alloplastic reconstruction of the extensor mechanism using the patellar-loop technique.

Between February 1998 and December 2009, we carried out wide local excision of a primary sarcoma of the proximal tibia, proximal tibial replacement and reconstruction of the extensor mechanism using the patellar-loop technique in 18 patients. Of these, nine were available for evaluation after a mean of 11.6 years (0.5 to 21.6). The strength of the knee extensors was measured using an Isobex machine and gait analysis was undertaken in our gait assessment laboratory. Functional outcome was assessed using the American Knee Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores.

The gait pattern of the patients differed in ground contact time, flexion heel strike, maximal flexion loading response and total sagittal plane excursion. The mean maximum active flexion was 91° (30° to 110°). The overall mean extensor lag was 1° (0° to 5°). The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that in the non-operated leg (p < 0.001). The mean functional scores were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional score).

In summary, the results show that reconstruction of the extensor mechanism using this technique gives good biomechanical and functional results. The patients’ gait pattern is close to normal, except for a somewhat stiff knee gait pattern. The strength of the extensor mechanism is reduced, but sufficient for walking.

Cite this article: Bone Joint J 2015;97-B:1063–9.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 70 - 72
1 Nov 2014
Callaghan JJ Liu SS Phruetthiphat O

A common situation presenting to the orthopaedic surgeon today is a worn acetabular liner with substantial acetabular and pelvic osteolysis. The surgeon has many options for dealing with osteolytic defects. These include allograft, calcium based substitutes, demineralised bone matrix, or combinations of these options with or without addition of platelet rich plasma. To date there are no clinical studies to determine the efficacy of using bone-stimulating materials in osteolytic defects at the time of revision surgery and there are surprisingly few studies demonstrating the clinical efficacy of these treatment options. Even when radiographs appear to demonstrate incorporation of graft material CT studies have shown that incorporation is incomplete. The surgeon, in choosing a graft material for a surgical procedure must take into account the efficacy, safety, cost and convenience of that material.

Cite this article: Bone Joint J 2014;96-B (11 Suppl A):70–2.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1347 - 1354
1 Oct 2016
Palan J Smith MC Gregg P Mellon S Kulkarni A Tucker K Blom AW Murray DW Pandit H

Aims

Periprosthetic fracture (PF) after primary total hip arthroplasty (THA) is an uncommon but potentially devastating complication. This study aims to investigate the influence of cemented stem designs on the risk of needing a revision for a PF.

Patients and Methods

We analysed data on 257 202 primary THAs with cemented stems and 390 linked first revisions for PF recorded in the National Joint Registry (NJR) of England, Wales and Northern Ireland to determine if a cemented femoral stem brand was associated with the risk of having revision for a PF after primary THA. All cemented femoral stem brands with more than 10 000 primary operations recorded in the NJR were identified. The four most commonly used cemented femoral stems were the Exeter V40 (n = 146 409), CPT (n = 24 300), C-Stem (n = 15 113) and Charnley (n = 20 182).

We compared the revision risk ratios due to PF amongst the stems using a Poisson regression model adjusting for patient factors. Compared with the Exeter V40, the age, gender and ASA grade adjusted revision rate ratio was 3.89 for the cemented CPT stem (95% confidence interval (CI) 3.07 to 4.93), 0.89 for the C-Stem (95% CI 0.57 to 1.41) and 0.41 for the Charnley stem (95% CI 0.24 to 0.70).


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1289 - 1296
1 Sep 2016
McNally MA Ferguson JY Lau ACK Diefenbeck M Scarborough M Ramsden AJ Atkins BL

Aims

Chronic osteomyelitis may recur if dead space management, after excision of infected bone, is inadequate. This study describes the results of a strategy for the management of deep bone infection and evaluates a new antibiotic-loaded biocomposite in the eradication of infection from bone defects.

Patients and Methods

We report a prospective study of 100 patients with chronic osteomyelitis, in 105 bones. Osteomyelitis followed injury or surgery in 81 patients. Nine had concomitant septic arthritis. 80 patients had comorbidities (Cierny-Mader (C-M) Class B hosts). Ten had infected nonunions.

All patients were treated by a multidisciplinary team with a single-stage protocol including debridement, multiple sampling, culture-specific systemic antibiotics, stabilisation, dead space filling with the biocomposite and primary skin closure.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 98 - 102
1 Nov 2013
Ibrahim MS Raja S Haddad FS

The increasing need for total hip replacement (THR) in an ageing population will inevitably generate a larger number of revision procedures. The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. The failed acetabular component requires reconstruction to restore the hip centre and improve joint biomechanics. Impaction bone grafting is successful in achieving acetabular reconstruction using both cemented and cementless techniques. Bone graft incorporation restores bone stock whilst providing good component stability. We provide a summary of the evidence and current literature regarding impaction bone grafting using both cemented and cementless techniques in revision THR.

Cite this article: Bone Joint J 2013;95-B, Supple A:98–102.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1522 - 1527
1 Nov 2008
Davis ET Olsen M Zdero R Waddell JP Schemitsch EH

A total of 20 pairs of fresh-frozen cadaver femurs were assigned to four alignment groups consisting of relative varus (10° and 20°) and relative valgus (10° and 20°), 75 composite femurs of two neck geometries were also used. In both the cadaver and the composite femurs, placing the component in 20° of valgus resulted in a significant increase in load to failure. Placing the component in 10° of valgus had no appreciable effect on increasing the load to failure except in the composite femurs with varus native femoral necks. Specimens in 10° of varus were significantly weaker than the neutrally-aligned specimens.

The results suggest that retention of the intact proximal femoral strength occurs at an implant angulation of ≥ 142°. However, the benefit of extreme valgus alignment may be outweighed in clinical practice by the risk of superior femoral neck notching, which was avoided in this study.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1604 - 1607
1 Dec 2015
Wassilew GI Perka C Janz V Krämer M Renner L

We have investigated the effect of using tranexamic acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative blood loss and blood transfusion requirements. In addition we analysed whether the use of TXA was associated with an increased risk of venous thromboembolism (VTE) following this procedure.

A consecutive series of 96 PAOs, performed by a single surgeon, were reviewed. A total of 48 patients received TXA and 48 did not. The TXA group received a continuous infusion of TXA at a rate of 10 mg/kg/h. The primary outcome measure was the requirement for blood transfusion. Secondary outcomes included total blood loss, the decrease in the level of haemoglobin in the blood, the length of hospital stay, and the complications of this treatment.

The mean rate of transfusion was significantly lower in the TXA group (62.5% vs 12.5%, p < 0.001). The mean blood loss was also significantly reduced in the TXA group (1.9 L (standard deviation (sd) 0.9) vs 1.5 L (sd 0.7), p < 0.01). No post-operative episodes of VTE were identified in either group.

The use of TXA reduced the blood loss and the rate of transfusion after PAO significantly, without adverse effects such as an increased rate of VTE.

Cite this article: Bone Joint J 2015;97-B:1604–7.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 173 - 178
1 Feb 2016
Sassoon A Nam D Jackups R Johnson SR Nunley RM Barrack RL

Aims

This study investigated whether the use of tranexamic acid (TXA) decreased blood loss and transfusion related cost following surface replacement arthroplasty (SRA).

Methods

A retrospective review of patients treated with TXA during a SRA, who did not receive autologous blood (TXA group) was performed. Two comparison groups were established; the first group comprised of patients who donated their own blood pre-operatively (auto group) and the second of patients who did not donate blood pre-operatively (control). Outcomes included transfusions, post-operative haemoglobin (Hgb), complications, and length of post-operative stay.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1488 - 1492
1 Nov 2015
Tansey RJ Benjamin-Laing H Jassim S Liekens K Shankar A Haddad FS

Hip and groin injuries are common in athletes who take part in high level sports. Adductor muscle tendon injuries represent a small but important number of these injuries. Avulsion of the tendons attached to the symphysis pubis has previously been described: these can be managed both operatively and non-operatively. We describe an uncommon variant of this injury, namely complete avulsion of the adductor sleeve complex: this includes adductor longus, pectineus and rectus abdominis. We go on to describe a surgical technique which promotes a full return to the pre-injury level of sporting activity.

Over a period of ten years, 15 high-level athletes with an MRI-confirmed acute adductor complex avulsion injury (six to 34 days old) underwent surgical repair. The operative procedure consisted of anatomical re-attachment of the avulsed tissues in each case and mesh reinforcement of the posterior inguinal wall in seven patients. All underwent a standardised rehabilitation programme, which was then individualised to be sport-specific.

One patient developed a superficial wound infection, which was successfully treated with antibiotics. Of the 15 patients, four complained of transient local numbness which resolved in all cases. All patients (including seven elite athletes) returned to their previous level of participation in sport.

Cite this article: Bone Joint J 2015;97-B:1488–92.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 81 - 87
1 Jan 2016
Miska M Findeisen S Tanner M Biglari B Studier-Fischer S Grützner PA Schmidmaier G Moghaddam A

Methods

Between 2005 and 2012, 50 patients (23 female, 27 male) with nonunion of the humeral shaft were included in this retrospective study. The mean age was 51.3 years (14 to 88). The patients had a mean of 1.5 prior operations (sd 1.2;1 to 8).

All patients were assessed according to a specific risk score in order to devise an optimal and individual therapy plan consistent with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis to an angular stable locking compression plate was performed. According to the individual risk an additional bone graft and/or bone morphogenetic protein-7 (BMP-7) were applied.

Results

A successful consolidation of the nonunion was observed in 37 cases (80.4%) with a median healing time of six months (IQR 6). Younger patients showed significantly better consolidation. Four patients were lost to follow-up. Revision was necessary in a total of eight (16%) cases. In the initial treatment, intramedullary nailing was most common.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1447 - 1455
1 Nov 2015
Alshameeri Z Bajekal R Varty K Khanduja V

Vascular injuries during total hip arthroplasty (THA) are rare but when they occur, have serious consequences. These have traditionally been managed with open exploration and repair, but more recently there has been a trend towards percutaneous endovascular management.

We performed a systematic review of the literature to assess if this change in trend has led to an improvement in the overall reported rates of morbidity and mortality during the last 22 years in comparison with the reviews of the literature published previously.

We found a total of 61 articles describing 138 vascular injuries in 124 patients. Injuries because of a laceration were the most prevalent (n = 51, 44%) and the most common presenting feature, when recorded, was bleeding (n = 41, 53.3%). Delay in diagnosis was associated with the type of vascular lesion (p < 0.001) and the clinical presentation (p = 0.002).

Open exploration and repair was the most common form of management, however percutaneous endovascular intervention was used in one third of the injuries and more constantly during the last 13 years.

The main overall reported complications included death (n = 9, 7.3%), amputation (n = 2, 1.6%), and persistent ischaemia (n = 9, 7.3%). When compared with previous reviews there was a similar rate of mortality but lower rates of amputation and permanent disability, especially in patients managed by endovascular strategies.

Cite this article: Bone Joint J 2015;97-B:1447–55.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1017 - 1023
1 Aug 2015
Phan D Bederman SS Schwarzkopf R

The interaction between the lumbosacral spine and the pelvis is dynamically related to positional change, and may be complicated by co-existing pathology. This review summarises the current literature examining the effect of sagittal spinal deformity on pelvic and acetabular orientation during total hip arthroplasty (THA) and provides recommendations to aid in placement of the acetabular component for patients with co-existing spinal pathology or long spinal fusions. Pre-operatively, patients can be divided into four categories based on the flexibility and sagittal balance of the spine. Using this information as a guide, placement of the acetabular component can be optimal based on the type and significance of co-existing spinal deformity.

Cite this article: Bone Joint J 2015;97-B:1017–23.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 809 - 813
1 Jun 2015
Butt DA Hester T Bilal A Edmonds M Kavarthapu V

Charcot neuro-osteoarthropathy (CN) of the midfoot presents a major reconstructive challenge for the foot and ankle surgeon. The Synthes 6 mm Midfoot Fusion Bolt is both designed and recommended for patients who have a deformity of the medial column of the foot due to CN. We present the results from the first nine patients (ten feet) on which we attempted to perform fusion of the medial column using this bolt. Six feet had concurrent hindfoot fusion using a retrograde nail. Satisfactory correction of deformity of the medial column was achieved in all patients. The mean correction of calcaneal pitch was from 6° (-15° to +18°) pre-operatively to 16° (7° to 23°) post-operatively; the mean Meary angle from 26° (3° to 46°) to 1° (1° to 2°); and the mean talometatarsal angle on dorsoplantar radiographs from 27° (1° to 48°) to 1° (1° to 3°).

However, in all but two feet, at least one joint failed to fuse. The bolt migrated in six feet, all of which showed progressive radiographic osteolysis, which was considered to indicate loosening. Four of these feet have undergone a revision procedure, with good radiological evidence of fusion. The medial column bolt provided satisfactory correction of the deformity but failed to provide adequate fixation for fusion in CN deformities in the foot.

In its present form, we cannot recommend the routine use of this bolt.

Cite this article: Bone Joint J 2015; 97-B:809–13


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months.

The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery.

The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used.

The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less.

Cite this article: Bone Joint J 2015; 97-B:836–41


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 353 - 357
1 Mar 2015
Maffulli N Oliva F Costa V Del Buono A

We hypothesised that a minimally invasive peroneus brevis tendon transfer would be effective for the management of a chronic rupture of the Achilles tendon. In 17 patients (three women, 14 men) who underwent minimally invasive transfer and tenodesis of the peroneus brevis to the calcaneum, at a mean follow-up of 4.6 years (2 to 7) the modified Achilles tendon total rupture score (ATRS) was recorded and the maximum circumference of the calf of the operated and contralateral limbs was measured. The strength of isometric plantar flexion of the gastrocsoleus complex and of eversion of the ankle were measured bilaterally. Functional outcomes were classified according to the four-point Boyden scale.

At the latest review, the mean maximum circumference of the calf of the operated limb was not significantly different from the pre-operative mean value, (41.4 cm, 32 to 50 vs 40.6 cm, 33 to 46; p = 0.45), and not significantly less than that of the contralateral limb (43.1 cm, 35 to 52; p = 0.16). The mean peak torque (244.6 N, 125 to 367) and the strength of eversion of the operated ankle (149.1 N, 65 to 240) were significantly lower (p < 0.01) than those of the contralateral limb (mean peak torque 289, 145 to 419; strength of eversion: 175.2, 71 to 280). The mean ATRS significantly improved from 58 pre-operatively (35 to 68) to 91 (75 to 97; 95% confidence interval 85.3 to 93.2) at the time of final review. Of 13 patients who practised sport at the time of injury, ten still undertook recreational activities.

This procedure may be safely performed, is minimally invasive, and allows most patients to return to pre-injury sport and daily activities.

Cite this article: Bone Joint J 2015;97-B:353–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46).

The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex.

All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients.

This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 115 - 117
1 Nov 2014
Mullaji A Shetty GM

Stems may improve fixation and stability of components during revision total knee replacement. However, the choice between cemented and cementless stems is not a clear one. Cemented stems offer several advantages in terms of versatility, mechanical stability, surgical technique and clinical outcome over their cementless counterpart.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):115–7.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 442 - 448
1 Apr 2015
Kosuge D Barry M

The management of children’s fractures has evolved as a result of better health education, changes in lifestyle, improved implant technology and the changing expectations of society. This review focuses on the changes seen in paediatric fractures, including epidemiology, the increasing problems of obesity, the mechanisms of injury, non-accidental injuries and litigation. We also examine the changes in the management of fractures at three specific sites: the supracondylar humerus, femoral shaft and forearm. There has been an increasing trend towards surgical stabilisation of these fractures. The reasons for this are multifactorial, including societal expectations of a perfect result and reduced hospital stay. Reduced hospital stay is beneficial to the social, educational and psychological needs of the child and beneficial to society as a whole, due to reduced costs.

Cite this article: Bone Joint J 2015; 97-B:442–8.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 295 - 300
1 Mar 2013
Cawley DT Kelly N McGarry JP Shannon FJ

The optimum cementing technique for the tibial component in cemented primary total knee replacement (TKR) remains controversial. The technique of cementing, the volume of cement and the penetration are largely dependent on the operator, and hence large variations can occur. Clinical, experimental and computational studies have been performed, with conflicting results. Early implant migration is an indication of loosening. Aseptic loosening is the most common cause of failure in primary TKR and is the product of several factors. Sufficient penetration of cement has been shown to increase implant stability.

This review discusses the relevant literature regarding all aspects of the cementing of the tibial component at primary TKR.

Cite this article: Bone Joint J 2013;95-B:295–300.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 83 - 88
1 Jan 2015
Kocsis G McCulloch TA Thyagarajan D Wallace WA

The LockDown device (previously called Surgilig) is a braided polyester mesh which is mostly used to reconstruct the dislocated acromioclavicular joint. More than 11 000 have been implanted worldwide. Little is known about the tissue reaction to the device nor to its wear products when implanted in an extra-articular site in humans. This is of importance as an adverse immunological reaction could result in osteolysis or damage to the local tissues, thereby affecting the longevity of the implant.

We analysed the histology of five LockDown implants retrieved from five patients over the last seven years by one of the senior authors. Routine analysis was carried out in all five cases and immunohistochemistry in one.

The LockDown device acts as a scaffold for connective tissue which forms an investing fibrous pseudoligament. The immunological response at the histological level seems favourable with a limited histiocytic and giant cell response to micron-sized wear particles. The connective tissue envelope around the implant is less organised than a native ligament.

Cite this article: Bone Joint J 2015;97-B:83–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 565 - 576
1 May 2009
Getgood A Brooks R Fortier L Rushton N

Articular cartilage repair remains a challenge to surgeons and basic scientists. The field of tissue engineering allows the simultaneous use of material scaffolds, cells and signalling molecules to attempt to modulate the regenerative tissue. This review summarises the research that has been undertaken to date using this approach, with a particular emphasis on those techniques that have been introduced into clinical practice, via in vitro and preclinical studies.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 427 - 431
1 Mar 2015
Wu C Hsieh P Fan Jiang J Shih H Chen C Hu C

Fresh-frozen allograft bone is frequently used in orthopaedic surgery. We investigated the incidence of allograft-related infection and analysed the outcomes of recipients of bacterial culture-positive allografts from our single-institute bone bank during bone transplantation. The fresh-frozen allografts were harvested in a strict sterile environment during total joint arthroplasty surgery and immediately stored in a freezer at -78º to -68º C after packing. Between January 2007 and December 2012, 2024 patients received 2083 allografts with a minimum of 12 months of follow-up. The overall allograft-associated infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts taken before implantation revealed 21 (1.0%) positive findings. The 21 recipients were given various antibiotics at the individual orthopaedic surgeon’s discretion. At the latest follow-up, none of these 21 recipients displayed clinical signs of infection following treatment. Based on these findings, we conclude that an incidental positive culture finding for allografts does not correlate with subsequent surgical site infection. Additional prolonged post-operative antibiotic therapy may not be necessary for recipients of fresh-frozen bone allograft with positive culture findings.

Cite this article: Bone Joint J 2015;97-B:427–31.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1525 - 1529
1 Nov 2014
Thangarajah T Alexander S Bayley I Lambert SM

We report our experience with glenohumeral arthrodesis as a salvage procedure for epilepsy-related recurrent shoulder instability. A total of six patients with epilepsy underwent shoulder fusion for recurrent instability and were followed up for a mean of 39 months (12 to 79). The mean age at the time of surgery was 31 years (22 to 38). Arthrodesis was performed after a mean of four previous stabilisation attempts (0 to 11) in all but one patient in whom the procedure was used as a primary treatment. All patients achieved bony union, with a mean time to fusion of 2.8 months (2 to 7). There were no cases of re-dislocation. One revision was undertaken for loosening of the metalwork, and then healed satisfactorily. An increase was noted in the mean subjective shoulder value, which improved from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively although it decreased in two patients. The mean Oxford shoulder instability score improved from 13 pre-operatively (7 to 21) to 24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis eliminated recurrent instability and improved functional outcome. Fusion surgery should therefore be considered in this patient population. However, since the majority of patients are young and active, they should be comprehensively counselled pre-operatively given the functional deficit that results from the procedure.

Cite this article: Bone Joint J 2014;96-B:1525–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 421 - 425
1 Mar 2005
Blom AW Cunningham JL Hughes G Lawes TJ Smith N Blunn G Learmonth ID Goodship AE

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery.

Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens.

There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 583 - 597
1 May 2013
Kurien T Pearson RG Scammell BE

We reviewed 59 bone graft substitutes marketed by 17 companies currently available for implantation in the United Kingdom, with the aim of assessing the peer-reviewed literature to facilitate informed decision-making regarding their use in clinical practice. After critical analysis of the literature, only 22 products (37%) had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita), Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question the need for so many different products, especially with limited published clinical evidence for their efficacy, and conclude that there is a considerable need for further prospective randomised trials to facilitate informed decision-making with regard to the use of current and future bone graft substitutes in clinical practice.

Cite this article: Bone Joint J 2013;95-B:583–97.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 508 - 512
1 Apr 2014
van Amerongen EA Creemers LB Kaoui N Bekkers JEJ Kon M Schuurman AH

Damage to the cartilage of the distal radioulnar joint frequently leads to pain and limitation of movement, therefore repair of this joint cartilage would be highly desirable. The purpose of this study was to investigate the fixation of scaffold in cartilage defects of this joint as part of matrix-assisted regenerative autologous cartilage techniques. Two techniques of fixation of collagen scaffolds, one involving fibrin glue alone and one with fibrin glue and sutures, were compared in artificially created cartilage defects of the distal radioulnar joint in a human cadaver. After being subjected to continuous passive rotation, the methods of fixation were evaluated for cover of the defect and pull out force.

No statistically significant differences were found between the two techniques for either cover of the defect or integrity of the scaffold. However, a significantly increased mean pull out force was found for the combined procedure, 0.665 N (0.150 to 1.160) versus 0.242 N (0.060 to 0.730) for glue fixation (p = 0.001).

This suggests that although successful fixation of a collagen type I/III scaffold in a distal radioulnar joint cartilage defect is feasible with both forms of fixation, fixation with glue and sutures is preferable.

Cite this article: Bone Joint J 2014;96-B:508–12.