header advert
Results 121 - 140 of 258
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 858 - 860
1 Aug 2002
Reed MR Bliss W Sher JL Emmerson KP Jones SMG Partington PF

We undertook a prospective, randomised study of 135 total knee arthroplasties to determine the most accurate and reliable technique for alignment of the tibial prosthesis. Tibial resection was guided by either intramedullary or extramedullary alignment jigs.

Of the 135 knees, standardised postoperative radiographs suitable for assessment were available in 100. Correct tibial alignment was found in 85% of the intramedullary group compared with 65% of the extramedullary group (p = 0.019).

We conclude that intramedullary guides are superior to extramedullary instruments for alignment of the tibial prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 151 - 151
1 Jan 2002
Jones JWM Eckersley JRT


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 619 - 621
1 May 2001
ALI F JONES S SHELBROOKE K


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 448 - 458
1 Apr 2001
Jones LC Frondoza C Hungerford DS

The pathogenesis of aseptic loosening of total joint prostheses is not clearly understood. Two features are associated with loosened prostheses, namely, particulate debris and movement of the implant. While numerous studies have evaluated the cellular response to particulate biomaterials, few have investigated the influence of movement of the implant on the biological response to particles. Our aim was therefore to test the hypothesis that excessive mechanical stimulation of the periprosthetic tissues induces an inflammatory response and that the addition of particulate biomaterials intensifies this.

We allocated 66 adult Beagle dogs to four groups as follows: stable implants with (I) and without (II) particulate polymethylmethacrylate (PMMA) and moving implants with (III) and without (IV) particulate PMMA. They were then evaluated at 2, 4, 6, 12 and 24 weeks.

The stable implants were well tolerated and a thin, fibrous membrane of connective tissue was observed. There was evidence of positive staining in some cells for interleukin-6 (IL-6). Addition of particulate PMMA around the stable implants resulted in an increase in the fibroblastic response and positive staining for IL-6 and tumour necrosis factor-alpha (TNF-α). By contrast, movement of the implant resulted in an immediate inflammatory response characterised by large numbers of histiocytes and cytokine staining for IL-1ß, TNF-α and IL-6. Introduction of particulate PMMA aggravated this response. Animals with particulate PMMA and movement of the implant have an intense inflammatory response associated with accelerated bone loss.

Our results indicate that the initiation of the inflammatory response to biomaterial particles was much slower than that to gross mechanical instability. Furthermore, when there was both particulate debris and movement, there was an amplification of the adverse tissue response as evidenced by the presence of osteolysis and increases in the presence of inflammatory cells and their associated cytokines.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 345 - 347
1 Apr 2001
Harcourt WGV White SH Jones P

There is a need for the accurate measurement of the outcome after knee surgery. The Oxford Knee Score is being increasingly used since it is reported to be short, simple, inexpensive and validated.

We sent the questionnaire to 346 patients awaiting surgery to the hip or lumbar spine. Only 11% of 141 patients with proximal pathology who denied knee problems gave a maximum score. Their mean score was substantially lower than expected at 28.7 (maximum 48), and was significantly lower than the score of 36.5 obtained from patients after total knee replacement.

We therefore suggest that the frequent coexistence of hip or spinal pathology will significantly alter both the absolute score and any improvement to be expected after knee surgery. Although sensitive to disability originating from the knee the Oxford Knee Score is not sufficiently specific since it is heavily influenced by more proximal pathology.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 106 - 111
1 Jan 2001
Brown R Hussain M McHugh K Novelli V Jones D

Discitis is uncommon in children and presents in different ways at different ages. It is most difficult to diagnose in the uncommunicative toddler of one to three years of age. We present 11 consecutive cases. The non-specific clinical features included refusal to walk (63%), back pain (27%), inability to flex the lower back (50%) and a loss of lumbar lordosis (40%). Laboratory tests were unhelpful and cultures of blood and disc tissue were negative.

MRI reduces the diagnostic delay and may help to avoid the requirement for a biopsy. In 75% of cases it demonstrated a paravertebral inflammatory mass, which helped to determine the duration of the oral therapy given after initial intravenous antibiotics.

At a mean follow-up of 21 months (10 to 40), all the spines were mobile and the patients free from pain. Radiological fusion occurred in 20% and was predictable after two years. At follow-up, MRI showed variable appearances: changes in the vertebral body usually resolved at 24 months and recovery of the disc was seen after 34 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1204 - 1204
1 Nov 2000
JONES S ALI F FERNDANDES J


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1207 - 1207
1 Nov 2000
JONES DH


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1085 - 1085
1 Sep 2000
JONES S ALI F FERNDANDEZ J


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1083 - 1083
1 Sep 2000
JONES DHA


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 160 - 164
1 Mar 2000
Jones DH Dezateux CA Danielsson LG Paton RW Clegg J


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 991 - 994
1 Nov 1999
Morgan-Jones RL Cross MJ

Thirty cruciate ligaments were retrieved from either cadavers or limbs which had been amputated. Each specimen was sectioned and stained to demonstrate the presence of collagen, nerves and vessels.

All 30 specimens contained an interconnecting band of collagen fibres between the anterior and posterior cruciate ligaments. Vascular structures were present in all specimens and nerve fibres were identified in 26 (86%). We have called this structure the ‘intercruciate band’. The anterior and posterior cruciate ligaments should no longer be thought of in isolation, but together as a ‘cruciate complex’.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1023 - 1028
1 Nov 1999
Williams PR Jones DA Bishay M

Between January 1987 and December 1988 there were 7575 births in the Swansea maternity unit. Of these 823 (10.9%) were considered to be at ‘high risk’ for developmental dysplasia of the hip (DDH). Static ultrasound examination was performed in each case and the results classified on the basis of the method of Graf. A total of 117 type III–IV hips in 83 infants was splinted using the Aberdeen splint.

Radiographs of these hips were taken at six and 12 months. Hilgenreiner’s measurements of the acetabular angle were made in all cases and the development of the femoral capital epiphysis was assessed by measuring the epiphyseal area. The effect of splintage on the acetabular angle and the epiphyseal area between the normal and abnormal splinted hips was compared. Radiographs of 16 normal infants (32 normal unsplinted hips) were used as a control group.

This cohort has now been followed up for a minimum of nine years. There have been no complications as a result of splintage. The failure rate was 1.7% or 0.25 per 1000 live births. No statistical difference was found when comparing the effect of splintage on the acetabular angle and epiphyseal area between normal and abnormal splinted hips and normal unsplinted hips.

Our study has shown that while the Aberdeen splint had a definite but small failure rate, it was safe in that it did not produce avascular necrosis. The current conventional view that a low rate of splintage is always best is therefore brought into question if the Aberdeen splint is chosen for the management of neonatal DDH.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 744 - 744
1 Jul 1999
JONES D


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 560 - 560
1 May 1999
JONES D


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 943 - 945
1 Nov 1998
Jones D


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 184 - 184
1 Jan 1998
Jones DHA


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 576 - 582
1 Jul 1997
Haddad FS Jones DHA Vellodi A Kane N Pitt MC

Children with a mucopolysaccharidosis or mucolipidosis suffer progressive disability of the hands, particularly in relation to dysfunction of the median nerve. This is an increasing problem because bone-marrow transplantation has dramatically improved survival without apparently changing the musculoskeletal manifestations. We have reviewed 48 children with these syndromes who required carpal tunnel decompression, recording symptoms, signs, radiological, electrophysiological and operative findings, histology and upper-limb function. In these children the carpal tunnel syndrome differs from that seen in adults. Symptoms are rare but signs such as decreased sweating, pulp atrophy, thenar wasting and manual clumsiness are much more common. At operation, the flexor retinaculum was thickened and a mass of white tenosynovium engulfed the flexor tendons. Most patients had some definite nerve constriction with a thickened epineurium.

Functional improvement was seen after early decompression, with some benefit from simultaneous tendon release. Regular physiotherapy helped to maintain increased hand movement.

We describe our assessment protocol, the physiotherapy and operative regime and the standard functional review which helps to maximise function in the hands and upper limbs of these children.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 471 - 476
1 May 1996
Haidar RK Jones RS Vergroesen DA Evans GA

We have studied retrospectively 37 hips in 36 children at an average of 91 months after simultaneous open reduction and Salter innominate osteotomy for developmental hip dysplasia. At the latest review 97.3% were clinically and 83.8% radiologically good or excellent. In three hips (8%) there were signs of avascular necrosis, but only one had been symptomatic. There were no cases of recurrent posterior displacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 640 - 644
1 Jul 1995
Li P Jones N Gregg P

The early diagnosis of aseptic loosening of a total hip replacement by plain radiography, scintigraphy and arthrography has been shown to be unreliable. It has been suggested that it may be possible to distinguish between a secure and a loose prosthesis using a vibration technique. We have assessed the use of this technique in vitro using models of early and late loosening. Late loosening with an unstable prosthesis can be reliably detected by vibration analysis, but this method was shown to have a very poor diagnostic sensitivity in early loosening when there is no obvious prosthetic instability.