Advertisement for orthosearch.org.uk
Results 1 - 20 of 657
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 636 - 642
1 May 2013
Gøthesen Ø Espehaug B Havelin L Petursson G Lygre S Ellison P Hallan G Furnes O

We evaluated the rates of survival and cause of revision of seven different brands of cemented primary total knee replacement (TKR) in the Norwegian Arthroplasty Register during the years 1994 to 2009. Revision for any cause, including resurfacing of the patella, was the primary endpoint. Specific causes of revision were secondary outcomes. Three posterior cruciate-retaining (PCR) fixed modular-bearing TKRs, two fixed non-modular bearing PCR TKRs and two mobile-bearing posterior cruciate-sacrificing TKRs were investigated in a total of 17 782 primary TKRs. The median follow-up for the implants ranged from 1.8 to 6.9 years. Kaplan-Meier 10-year survival ranged from 89.5% to 95.3%. Cox’s relative risk (RR) was calculated relative to the fixed modular-bearing Profix knee (the most frequently used TKR in Norway), and ranged from 1.1 to 2.6. The risk of revision for aseptic tibial loosening was higher in the mobile-bearing LCS Classic (RR 6.8 (95% confidence interval (CI) 3.8 to 12.1)), the LCS Complete (RR 7.7 (95% CI 4.1 to 14.4)), the fixed modular-bearing Duracon (RR 4.5 (95% CI 1.8 to 11.1)) and the fixed non-modular bearing AGC Universal TKR (RR 2.5 (95% CI 1.3 to 5.1)), compared with the Profix. These implants (except AGC Universal) also had an increased risk of revision for femoral loosening (RR 2.3 (95% CI 1.1 to 4.8), RR 3.7 (95% CI 1.6 to 8.9), and RR 3.4 (95% CI 1.1 to 11.0), respectively). These results suggest that aseptic loosening is related to design in TKR. Cite this article: Bone Joint J 2013;95-B:636–42


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 52 - 56
1 Jan 2003
Johnson GV Worland RL Keenan J Norambuena N

As the surgical indications for total knee replacement (TKR) expand to include younger, heavier and more active patients, knowledge of the effect of these demographic variables on the outcome and survival of the implant is increasingly important.

Between November 1986 and September 1990, 402 patients underwent 562 primary cemented cruciate-retaining TKRs carried out by a single surgical team. The overall results showed a survival of 96.8% at 14 years with 1.44% lost to follow-up. Evaluating the demographics of these patients showed that certain groups fared significantly less well. The best results were seen in non-obese women with osteoarthritis who were over 60 years of age in whom there was ten-year survival of 99.4%. The worst results were in obese men with osteoarthritis who were less than 60 years of age in whom there was a ten-year survival of 35.7%. Caution should be exercised when considering TKR on a patient with this combination of poor risk factors.

By identifying demographic factors at the time of consultation the surgeon is better able to predict the survival of the TKR. This information is important when considering the best options for treatment of a patient and in providing accurate information during preoperative counselling.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 81 - 88
1 Mar 2024
Lustig S Cotte M Foissey C Asirvatham RD Servien E Batailler C

Aims. The benefit of a dual-mobility acetabular component (DMC) for primary total hip arthroplasties (THAs) is controversial. This study aimed to compare the dislocation and complication rates when using a DMC compared to single-mobility (SM) acetabular component in primary elective THA using data collected at a single centre, and compare the revision rates and survival outcomes in these two groups. Methods. Between 2010 and 2019, 2,075 primary THAs using either a cementless DM or SM acetabular component were included. Indications for DMC were patients aged older than 70 years or with high risk of dislocation. All other patients received a SM acetabular component. Exclusion criteria were cemented implants, patients treated for femoral neck fracture, and follow-up of less than one year. In total, 1,940 THAs were analyzed: 1,149 DMC (59.2%) and 791 SM (40.8%). The mean age was 73 years (SD 9.2) in the DMC group and 57 years (SD 12) in the SM group. Complications and revisions have been analyzed retrospectively. Results. The mean follow-up was 41.9 months (SD 14; 12 to 134). There were significantly fewer dislocations in the DMC group (n = 2; 0.17%) compared to the SM group (n = 8; 1%) (p = 0.019). The femoral head size did not influence the dislocation rate in the SM group (p = 0.702). The overall complication rate in the DMC group was 5.1% (n = 59) and in the SM group was 6.7% (n = 53); these were not statistically different (p = 0.214). No specific complications were attributed to the use of DMCs. In the DMC group, 18 THAs (1.6%) were revised versus 15 THAs in the SM group (1.9%) (p = 0.709). There was no statistical difference for any cause of revisions in both groups. The acetabular component aseptic revision-free survival rates at five years were 98% in the DMC group and 97.3% in the SM group (p = 0.780). Conclusion. The use of a monobloc DMC had a lower risk of dislocation in a high-risk population than SM component in a low-risk population at the mid-term follow-up. There was no significant risk of component-specific complications or revisions with DMCs in this large cohort. Cite this article: Bone Joint J 2024;106-B(3 Supple A):81–88


Aims. The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral. Methods. The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype. Results. The most common phenotype was Type I-b (mild to moderate varus alignment-medial joint line; 27.1% (n = 256)), followed by Type IV-b (23.2%; n = 219). There was no significant difference in the clinical outcomes and long-term survival between the groups. In Type IV-b phenotypes, the neutrally corrected group showed higher 15-year survival compared with the unchanged-phenotype group (94.9% (95% confidence interval (CI) 92.0 to 97.8) vs 74.2% (95% CI 98.0 to 100); p = 0.020). Conclusion. Constitutional varus was confirmed in more than half of these patients. Mechanically aligned TKA can achieve consistent clinical outcomes and long-term survival, regardless of the patient’s phenotype. The neutrally corrected group had better long-term survival compared with the unchanged phenotype group. Cite this article: Bone Joint J 2024;106-B(5):460–467


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1071 - 1076
1 Aug 2012
Lim H Bae J Song S Kim S

Medium-term survivorship of the Oxford phase 3 unicompartmental knee replacement (UKR) has not yet been established in an Asian population. We prospectively evaluated the outcome of 400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at the time of operation of 69 years (48 to 82). The mean follow-up was 5.2 years (1 to 10). Clinical and radiological assessment was carried out pre- and post-operatively. At five years, the mean Knee Society knee and functional scores had increased significantly from 56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively. The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival rate was 94% (95% confidence interval 90.1 to 98.0). A total of 14 UKRs (3.5%) required revision. The most common reason for revision was dislocation of the bearing in 12 (3%). Conversion to a total knee replacement was required in two patients who developed osteoarthritis of the lateral compartment.

This is the largest published series of UKR in Korean patients. It shows that the mid-term results after a minimally invasive Oxford phase 3 UKR can yield satisfactory clinical and functional results in this group of patients.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 25 - 31
1 May 2024
Yasunaga Y Oshima S Shoji T Adachi N Ochi M

Aims. The objective of this study was to present the outcomes of rotational acetabular osteotomy (RAO) over a 30-year period for osteoarthritis (OA) secondary to dysplasia of the hip in pre- or early-stage OA. Methods. Between September 1987 and December 1994, we provided treatment to 47 patients (55 hips) with RAO for the management of pre- or early-stage OA due to developmental hip dysplasia. Of those, eight patients (11 hips) with pre-OA (follow-up rate 79%) and 27 patients (32 hips) with early-stage OA (follow-up rate 78%), totalling 35 patients (43 hips) (follow-up rate 78%), were available at a minimum of 28 years after surgery. Results. In the pre-OA group, the mean Merle d'Aubigné score improved significantly from 14.5 points (SD 0.7) preoperatively to 17.4 points at final follow-up (SD 1.2; p = 0.004) and in the early-stage group, the mean score did not improve significantly from 14.0 (SD 0.3) to 14.6 (SD 2.4; p = 0.280). Radiologically, the centre-edge angle, acetabular roof angle, and head lateralization index were significantly improved postoperatively in both groups. Radiological progression of OA was observed in two patients (two hips) in the pre-OA group and 17 patients (18 hips) in the early-stage group. Kaplan-Meier survival analysis, with radiological progression of OA as the primary outcome, projected a 30-year survival rate of 81.8% (95% confidence interval (CI) 0.59 to 1.00) for the pre-OA group and 42.2% (95% CI 0.244 to 0.600) for the early-stage group. In all cases, the overall survival rate stood at 51.5% (95% CI 0.365 to 0.674) over a 30-year period, and when the endpoint was conversion to total hip arthroplasty, the survival rate was 74.0% (95% CI 0.608 to 0.873). Conclusion. For younger patients with pre-OA, joint preservation of over 30 years can be expected after RAO. Cite this article: Bone Joint J 2024;106-B(5 Supple B):25–31


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 783 - 791
1 Aug 2024
Tanaka S Fujii M Kawano S Ueno M Nagamine S Mawatari M

Aims. The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia. Methods. We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure. Results. This study included 127 patients (137 hips). Median follow-up period was ten years (IQR 6 to 15). The median mHHS improved from 59 (IQR 52 to 70) preoperatively to 90 (IQR 73 to 96) at the latest follow-up (p < 0.001). The survival rate was 90% (95% CI 82 to 95) at ten years, decreasing to 21% (95% CI 7 to 48) at 20 years. Fair joint congruity on preoperative hip abduction radiographs and a decreased postoperative anterior wall index (AWI) were identified as independent risk factors for failure. The survival rate for the 42 hips with good preoperative joint congruity and a postoperative AWI ≥ 0.30 was 100% at ten years, and remained at 83% (95% CI 38 to 98) at 20 years. Conclusion. Although the overall clinical outcomes of TOA in patients with advanced osteoarthritis are suboptimal, favourable results can be achieved in selected cases with good preoperative joint congruity and adequate postoperative anterior acetabular coverage. Cite this article: Bone Joint J 2024;106-B(8):783–791


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims. Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. Methods. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up. Results. The mean duration from initial revision TAA to last follow-up was 15.0 years (SD 3.0; 11.2 to 20.5). The cumulative survival rates of the revised ankles were 81% (95% confidence interval (CI) 74% to 88%), 74% (65% to 82%), and 70% (61% to 79%) at five, ten, and 15 years, respectively. Comorbidities prior to primary TAA, aseptic loosening, instability, or grafting of cysts were found to be the most common risk factors for secondary revision. The median value for preoperative pain, as assessed using the visual analogue scale, declined from 6 (interquartile range (IQR) 5 to 8) to 2 (IQR 0 to 5) (p < 0.001) and the mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 43 (SD 17) preoperatively to 70 (SD 20) (p < 0.001) at last follow-up. Conclusion. Revision TAA offers acceptable survival rates after 15 years; it therefore offers a valuable option for treatment of implant failure in carefully selected cases. Although patient-reported outcomes improve substantially, the degree of improvement reported following primary TAA is not achieved. Cite this article: Bone Joint J 2024;106-B(1):46–52


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 767 - 774
1 Jul 2022
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M

Aims. Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome measures (PROMs) are still unclear. Accordingly, we assessed hip survival and PROMs at 20 years after transpositional osteotomy of the acetabulum (TOA). Methods. A total of 172 hips in 159 patients who underwent TOA were followed up at a mean of 21.02 years (16.6 to 24.6) postoperatively. Kaplan-Meier analysis was used to assess survivorship with an endpoint of total hip arthroplasty (THA). PROMs included the visual analogue scale (VAS) Satisfaction, VAS Pain, Oxford Hip Score (OHS), and Forgotten Joint Score-12 (FJS-12). Thresholds for favourable outcomes for OHS (≥ 42) and FJS-12 (≥ 51) were obtained using the receiver operating characteristic curve with VAS Satisfaction ≥ 50 and VAS Pain < 20 as anchors. Results. THA was performed on 37 hips (21.5%) by the latest follow-up. Kaplan-Meier analysis indicated that the hip survival rate at 20 years was 79.7% (95% confidence interval (CI) 73.7 to 86.3). Multivariate analysis showed that preoperative Tönnis grade significantly influenced hip survival. Tönnis grades 0, 1, and 2 were associated with 20-year survival rates of 93.3% (95% CI 84.8 to 100), 86.7% (95% CI 79.8 to 94.3), and 54.8% (95% CI 41.5 to 72.3), respectively. More than 60% of the patients exhibited favourable PROMs. An advanced Tönnis grade at the latest follow-up and a higher BMI were both significantly associated with unfavourable OHS, but not with other PROMs. Conclusion. This study demonstrated the durability of TOA for hips with Tönnis grades 0 to 1 at 20 years. While the presence of advanced osteoarthritis and higher BMI was associated with lower hip functions (OHS), it was not necessarily associated with worse patient satisfaction and joint awareness. Cite this article: Bone Joint J 2022;104-B(7):767–774


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 665 - 671
1 Apr 2021
Osawa Y Seki T Okura T Takegami Y Ishiguro N Hasegawa Y

Aims. We compared the clinical outcomes of curved intertrochanteric varus osteotomy (CVO) with bone impaction grafting (BIG) with CVO alone for the treatment of osteonecrosis of the femoral head (ONFH). Methods. This retrospective comparative study included 81 patients with ONFH; 37 patients (40 hips) underwent CVO with BIG (BIG group) and 44 patients (47 hips) underwent CVO alone (CVO group). Patients in the BIG group were followed-up for a mean of 12.2 years (10.0 to 16.5). Patients in the CVO group were followed-up for a mean of 14.5 years (10.0 to 21.0). Assessment parameters included the Harris Hip Score (HHS), Oxford Hip Score (OHS), Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ), complication rates, and survival rates, with conversion to total hip arthroplasty (THA) and radiological failure as the endpoints. Results. There were no significant differences in preoperative and postoperative HHS or postoperative OHS and JHEQ between the BIG group and the CVO group. Complication rates were comparable between groups. Ten-year survival rates with conversion to THA and radiological failure as the endpoints were not significantly different between groups. Successful CVO (postoperative coverage ratio of more than one-third) exhibited better ten-year survival rates with radiological failure as the endpoint in the BIG group (91.4%) than in the CVO group (77.7%), but this difference was not significant (p = 0.079). Conclusion. Long-term outcomes of CVO with BIG were favourable when proper patient selection and accurate surgery are performed. However, this study did not show improvements in treatment results with the concomitant use of BIG. Cite this article: Bone Joint J 2021;103-B(4):665–671


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 200 - 205
1 Feb 2022
Orita K Goto K Kuroda Y Kawai T Okuzu Y Matsuda S

Aims. The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA). Methods. We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up. Results. The mean follow-up period was 19.1 years (SD 0.6; 17.3 to 20.1). The 19-year overall survival rate with the end point of all-cause revision was 97.0% (95% confidence interval (CI) 91 to 100). The mean JOA score improved from 43.2 (SD 10.6; 30 to 76) before surgery to 90.2 (SD 6.4; 76 to 98) at the final follow-up (p < 0.001). There was no osteolysis or loosening of the acetabular or femoral components. The overall steady-state wear rate was 0.013 mm/year (SD 0.012). There was no hip with a steady-state wear rate of > 0.1 mm/year. There was no significant difference in wear rates for each period. We found no significant correlation between the wear rate and age, body weight, BMI, or cup inclination. Conclusion. First-generation annealed HXLPE shows excellent wear resistance and no acceleration of wear for approximately 20 years, with low all-cause revision rates. Cite this article: Bone Joint J 2022;104-B(2):200–205


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1000 - 1007
1 Sep 2024
Gong T Lu M Sheng H Li Z Zhou Y Luo Y Min L Tu C

Aims. Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. Methods. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively. Results. Overall, 21 patients (16%) encountered complications, and the rate of aseptic loosening was 7% (9/134). The survival rate up to 8.5 years was 93% for aseptic loosening as the endpoint, and 88% for any reason as the endpoint, retrospectively. Conclusion. The use of an uncemented distal femoral endoprosthesis with a short, curved stem demonstrated a low incidence of aseptic loosening and achieved long-term survivorship of up to nine years. Meanwhile, aseptic loosening typically occurs in the early stage postoperatively. Cite this article: Bone Joint J 2024;106-B(9):1000–1007


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants. Cite this article: Bone Joint J 2023;105-B(3):301–306


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 11 - 16
1 Jan 2023
San-Julián M Gómez-Álvarez J Idoate MÁ Aquerreta JD Vázquez-García B Lamo-Espinosa JM

Paediatric bone sarcomas are a dual challenge for orthopaedic surgeons in terms of tumour resection and reconstruction, as it is important to minimize functional and growth problems without compromising survival rates. Cañadell’s technique consists of a Type I epiphysiolysis performed using continuous distraction by an external fixator prior to resection. It was designed to achieve a safe margin due to the ability of the physeal cartilage to be a barrier to tumour spread in some situations, avoiding the need for articular reconstruction, and preserving the growth capacity most of the times. Despite initial doubts raised in the scientific community, this technique is now widely used in many countries for the treatment of metaphyseal paediatric bone sarcomas. This annotation highlights the importance of Cañadell’s work and reviews the experience of applying it to bone sarcoma patients over the last 40 years. Cite this article: Bone Joint J 2023;105-B(1):11–16


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results. We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion. This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential. Cite this article: Bone Joint J 2023;105-B(7):775–782


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1216 - 1225
1 Nov 2023
Fujiwara T Kunisada T Nakata E Mitsuhashi T Ozaki T Kawai A

Aims. Clear cell sarcoma (CCS) of soft-tissue is a rare melanocytic subtype of mesenchymal malignancy. The aim of this study was to investigate the clinical and therapeutic factors associated with increased survival, stratified by clinical stage, in order to determine the optimal treatment. Methods. The study was a retrospective analysis involving 117 patients with histologically confirmed CCS, between July 2016 and November 2017, who were enrolled in the Bone and Soft Tissue Tumour Registry in Japan. Results. The five- and ten-year survival rates were 41% (95% confidence interval (CI) 29 to 52) and 37% (95% CI 25 to 49), respectively. On multivariable analysis, the size of the tumour of > 10 cm (p = 0.006), lymph node metastasis at the time of diagnosis (p < 0.001), distant metastases at the time of diagnosis (p < 0.001), and no surgery for the primary tumour (p = 0.019) were independently associated with a poor survival. For N0M0 CCS (n = 68), the development of distant metastases was an independent prognostic factor for survival (early (< 12 months), hazard ratio (HR) 116.78 (95% CI 11.69 to 1,166.50); p < 0.001; late (> 12 months), HR 14.79 (95% CI 1.66 to 131.63); p = 0.016); neoadjuvant/adjuvant chemotherapy (p = 0.895) and/or radiotherapy (p = 0.216) were not significantly associated with survival. The five-year cumulative incidence of local recurrence was 19% (95% CI 8 to 35) and the size of the tumour was significantly associated with an increased rate of local recurrence (p = 0.012). For N1M0 CCS (n = 18), the risk of mortality was significantly lower in patients who underwent surgery for both the primary tumour and lymph node metastases (HR 0.03 (95% CI 0.00 to 0.56); p = 0.020). For M1 CCS (n = 31), excision of the primary tumour was independently associated with better survival (HR 0.26 (95% CI 0.09 to 0.76); p = 0.013). There was no significant difference in survival between the different types of systemic treatment (p = 0.523). Conclusion. Complete excision of the primary tumour and lymph nodes is associated with a better survival in patients with CCS. Systemic treatment appears to provide limited benefits, demonstrating a pressing need for novel systemic agents. Cite this article: Bone Joint J 2023;105-B(11):1216–1225


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. Results. Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm. 3. /year (95% CI -6.5 to 28.7). Conclusion. Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners. Cite this article: Bone Joint J 2023;105-B(1):29–34


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims. The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit. Methods. Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis. Results. Mean follow-up was 20.9 years (19.3 to 22.4). Registry data revealed that 19 hips (8.1%) had been revised and 26 patients (12%) had died from causes unrelated to the BHR. Among the remaining 189 hips, 61% were available for clinical follow-up at 20 years (n = 115) and 70% of patients had biochemical follow-up (n = 132). The cumulative implant survival rate at 20 years for male patients was 96.5% (95% confidence interval (CI) 93.5 to 99.6), and for female patients 87% (95% CI 79.7 to 94.9). The difference was statistically significant (p = 0.029). The mean Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, and Forgotten Joint Score were 45 (29 to 48), 89 (43 to 100), and 84 (19 to 100), respectively. The mean scores for each of the five domains of the EuroQol five-dimension three-level questionnaire were 1.2, 1.0, 1.2, 1.3, and 1.1, and mean overall score 82.6 (50 to 100). Ultrasound showed no pseudotumour. Mean cobalt and chromium levels were 32.1 nmol/l (1 to 374) and 45.5 nmol/l (9 to 408), respectively. Conclusion. This study shows that BHRs provide excellent survivorship and functional outcomes in young male patients. At 20 years, soft-tissue imaging and serum metal ion studies suggest that a metal-on-metal resurfacing implant can be well tolerated in a group of young patients. Cite this article: Bone Joint J 2023;105-B(9):946–952


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims. We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients. Methods. A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up. Results. We included 428 primary aTSAs with a mean follow-up of 2.4 years (SD 0.6). Our cohort consisted of 251 non-smokers, 138 former smokers who quit a mean 21 years (SD 14) prior to surgery (25 pack-years (SD 22)), and 39 current smokers (23 pack-years (SD 20)). At two- to four-year follow-up, former smokers had less favourable SPADI, SST, and FE strength compared to non-smokers, and current smokers had less favourable SPADI, SST, ASES score, UCLA score, Constant-Murley score, FE, abduction, and ER strength compared to non-smokers. Non-smokers exhibited higher revision-free survival rates at two, five, eight, and ten years postoperatively compared to former smokers and current smokers, who had similar rates. Conclusion. Our study suggests that smoking has a negative effect on aTSA functional outcomes that may persist even after quitting. Cite this article: Bone Joint J 2024;106-B(11):1263–1272