Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 86 - 92
1 Jan 2024
Scholte CHJ Dorleijn DMJ Krijvenaar DT van de Sande MAJ van Langevelde K

Aims. Due to its indolent clinical behaviour, the treatment paradigm of atypical cartilaginous tumours (ACTs) in the long bones is slowly shifting from intralesional resection (curettage) and local adjuvants, towards active surveillance through wait-and-scan follow-up. In this retrospective cohort study performed in a tertiary referral centre, we studied the natural behaviour of ACT lesions by active surveillance with MRI. Clinical symptoms were not considered in the surveillance programme. Methods. The aim of this study was to see whether active surveillance is safe regarding malignant degeneration and local progression. In total, 117 patients were evaluated with MRI assessing growth, cortical destruction, endosteal scalloping, periosteal reaction, relation to the cortex, and perilesional bone marrow oedema. Patients received up to six follow-up scans. Results. At the time of the first follow-up MRI, 8% of the lesions showed growth (n = 9), 86% remained stable (101), and 6% decreased in size (n = 7). During the third follow-up, with a mean follow-up time of 60 months (SD 23), 24 patients were scanned, of whom 13% had lesions that had grown and 13% lesions that had decreased in size. After 96 months (SD 37), at the sixth follow-up MRI, 100% of the lesions remained stable. None of the lesions showed malignant progression and although some lesions grew in size (mean 1 mm (SD 0.8)), no malignant progression occurred. Conclusion. We conclude that active surveillance with MRI is safe for ACTs in the long bones in the short- and mid-term follow-up. Cite this article: Bone Joint J 2024;106-B(1):86–92


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 729 - 734
1 Jul 2023
Borghi A Gronchi A

Desmoid tumours are a rare fibroblastic proliferation of monoclonal origin, arising in deep soft-tissues. Histologically, they are characterized by locally aggressive behaviour and an inability to metastasize, and clinically by a heterogeneous and unpredictable course. Desmoid tumours can occur in any anatomical site, but commonly arise in the limbs. Despite their benign nature, they can be extremely disabling and sometimes life-threatening, causing severe pain and functional limitations. Their surgical management is complex and challenging, due to uncertainties surrounding the biological and clinical behaviour, rarity, and limited available literature. Resection has been the first-line approach for patients with a desmoid tumour but, during the last few decades, a shift towards a more conservative approach has occurred, with an initial ‘wait and see’ policy. Many medical and regional forms of treatment are also available for the management of this condition, and others have recently emerged with promising results. However, many areas of controversy remain, and further studies and global collaboration are needed to obtain prospective and randomized data, in order to develop an appropriate shared stepwise approach.

Cite this article: Bone Joint J 2023;105-B(7):729–734.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 137 - 144
1 Jun 2021
Lachiewicz PF Steele JR Wellman SS

Aims

To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period.

Methods

This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 788 - 794
1 Apr 2021
Spierenburg G Lancaster ST van der Heijden L Mastboom MJL Gelderblom H Pratap S van de Sande MAJ Gibbons CLMH

Aims

Tenosynovial giant cell tumour (TGCT) is one of the most common soft-tissue tumours of the foot and ankle and can behave in a locally aggressive manner. Tumour control can be difficult, despite the various methods of treatment available. Since treatment guidelines are lacking, the aim of this study was to review the multidisciplinary management by presenting the largest series of TGCT of the foot and ankle to date from two specialized sarcoma centres.

Methods

The Oxford Tumour Registry and the Leiden University Medical Centre Sarcoma Registry were retrospectively reviewed for patients with histologically proven foot and ankle TGCT diagnosed between January 2002 and August 2019.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 383 - 387
1 Mar 2020
Wordie SJ Robb JE Hägglund G Bugler KE Gaston MS

Aims

The purpose of this study was to compare the prevalence of hip displacement and dislocation in a total population of children with cerebral palsy (CP) in Scotland before and after the initiation of a hip surveillance programme.

Patients

A total of 2,155 children with CP are registered in the Cerebral Palsy Integrated Pathway Scotland (CPIPS) surveillance programme, which began in 2013. Physical examination and hip radiological data are collected according to nationally agreed protocols.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 4 - 9
1 Jan 2013
Goyal N Miller A Tripathi M Parvizi J

Staphylococcus aureus is one of the leading causes of surgical site infection (SSI). Over the past decade there has been an increase in methicillin-resistant S. aureus (MRSA). This is a subpopulation of the bacterium with unique resistance and virulence characteristics. Nasal colonisation with either S. aureus or MRSA has been demonstrated to be an important independent risk factor associated with the increasing incidence and severity of SSI after orthopaedic surgery. Furthermore, there is an economic burden related to SSI following orthopaedic surgery, with MRSA-associated SSI leading to longer hospital stays and increased hospital costs. Although there is some controversy about the effectiveness of screening and eradication programmes, the literature suggests that patients should be screened and MRSA-positive patients treated before surgical admission in order to reduce the risk of SSI.

Cite this article: Bone Joint J 2013;95-B:4–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 39 - 46
1 Jan 2011
Sukeik M Alshryda S Haddad FS Mason JM

We report a systematic review and meta-analysis of published randomised controlled trials evaluating the efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion in total hip replacement (THR). The data were evaluated using the generic evaluation tool designed by the Cochrane Bone, Joint and Muscle Trauma Group. We identified 11 clinical trials which were suitable for detailed extraction of data. There were no trials that used TXA in revision THR. A total of seven studies (comprising 350 patients) were eligible for the blood loss outcome data. The use of TXA reduced intra-operative blood loss by a mean of 104 ml (95% confidence interval (CI) −164 to −44, p = 0.0006, heterogeneity I2 0%), postoperative blood loss by a mean of 172 ml (95% CI −263 to −81, p = 0.0002, heterogeneity I2 63%) and total blood loss by a mean of 289 ml (95% CI −440 to −138, p < 0.0002, heterogeneity I2 54%).

TXA led to a significant reduction in the proportion of patients requiring allogeneic blood transfusion (risk difference −0.20, 95% CI −0.29 to −0.11, p < 0.00001, I2 15%). There were no significant differences in deep-vein thrombosis, pulmonary embolism, infection rates or other complications among the study groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 749 - 754
1 Jun 2005
Giannoudis PV Parker J Wilcox MH