The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 713 - 719
1 Jul 2024
Patel MS Shah S Elkazaz MK Shafafy M Grevitt MP

Aims

Historically, patients undergoing surgery for adolescent idiopathic scoliosis (AIS) have been nursed postoperatively in a critical care (CC) setting because of the challenges posed by prone positioning, extensive exposures, prolonged operating times, significant blood loss, major intraoperative fluid shifts, cardiopulmonary complications, and difficulty in postoperative pain management. The primary aim of this paper was to determine whether a scoring system, which uses Cobb angle, forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and number of levels to be fused, is a valid method of predicting the need for postoperative critical care in AIS patients who are to undergo scoliosis correction with posterior spinal fusion (PSF).

Methods

We retrospectively reviewed all AIS patients who had undergone PSF between January 2018 and January 2020 in a specialist tertiary spinal referral centre. All patients were assessed preoperatively in an anaesthetic clinic. Postoperative care was defined as ward-based (WB) or critical care (CC), based on the preoperative FEV1, FVC, major curve Cobb angle, and the planned number of instrumented levels.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 12 - 12
1 Jun 2012
Noordeen H Shah S Elsebaie H Garrido E Farooq N Mukhtar M
Full Access

Introduction

Growing rods are used in the treatment of early-onset scoliosis. The aim of this technique is to achieve deformity correction while maintaining spinal growth. Gradual stiffening or spontaneous fusion of the spine can interfere with the ability to lengthen. Furthermore, diminished acquired length with serial distraction is common and needs to be evaluated and quantified. The purpose of this prospective study was to measure the forces and amount of distraction over time in patients with early-onset scoliosis treated with growing rods.

Methods

Distraction forces were measured prospectively during 60 consecutive lengthening procedures in 26 patients. All patients had single submuscular rod constructs with side-to-side connectors. For every measurement, output from a transducer on a dedicated pair of distraction calipers was recorded at zero load status, and the force was then recorded at every 1 mm lengthening; length was obtained at each event and was recorded in millimeters.