Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 39 - 39
1 Apr 2018
Jenny J De Gori M
Full Access

INTRODUCTION

The goal of the study was to perform quality control with a commercially available navigation system when introducing PST technique at our academic department. The learning curve was assessed by the Cumulative Sum (CUSUM) test. We hypothesized that the PST process for TKA was immediately under control after its introduction when analyzed with the CUSUM technique.

MATERIAL AND METHODS

The first 50 TKAs implanted with the use of PST at an academic department were scheduled to enter in a prospective, observational study. All TKAs were implanted by an experienced, high volume senior consultant with high experience in knee navigation. PSTs were carefully positioned over the bone and articular surfaces to the best fit position, without any navigated information. Then the 3D femoral and tibia PSTs positioning were recorded. The surgical procedure was then completed following the routine navigated procedure with standard navigated templates.

To assess the 3D positioning of each template individually and of both templates together as a surrogate of the final TKA positioning, one point was given for each item inside the target, giving a maximal femur and tibia scores of 4 points, and a maximal knee score of 8 points, when all items were fulfilled. Following dataset was used for CUSUM chart plotting: allowable slack = 0.5SD, acceptable limit score = 6 points for knee score and 2 points for femur and tibia scores. For each measurement Mx, two CUSUMs (upper and lower CUSUMs) were calculated. These sums were plotted against the rank of the observation i. A trend in the process results in a change in the slope of the CUSUM, whereas the values are expected to fluctuate around a horizontal line if the process is in control. The process was considered out of control if upper CUSUM or lower CUSUM is outside the acceptable deviation interval.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 4 - 4
1 Dec 2017
Jenny J De Gori M
Full Access

INTRODUCTION

The patient-specific templates (PST) for total knee arthroplasty (TKA) have been developed to improve accuracy of implantation, decrease operating time and decrease costs. There remains controversy about the accuracy of PST in comparison with either navigated or conventional instruments. Furthermore, the learning curve after introducing PST has not been well defined. The goal of the present study was to perform quality control with a commercially available navigation system and the CUCUM test when introducing PST technique at our academic department.

MATERIAL AND METHODS

The first 50 TKAs implanted with the use of PST at an academic department were scheduled to enter in a prospective, observational study. PSTs were designed to obtain a neutral coronal alignment. All TKAs were implanted by an experienced, high volume senior consultant with high experience in knee navigation. PSTs were carefully positioned over the bone and articular surfaces to the best fit position, without any navigated information. Then the 3D femoral and tibia PSTs positioning were recorded by the navigation system. The difference between expected and achieved position was calculated, and an accuracy score was calculated and plotted according to the rank of observation into a CUSUM test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 40 - 40
1 Feb 2016
Jenny J Diesinger Y de Gori M
Full Access

Introduction

An appropriate positioning of a total knee replacement (TKR) is a prerequisite for a good functional outcome and a prolonged survival. Navigation systems may facilitate this proper positioning. Patient specific templates have been developed to achieve at least the same accuracy than conventional instruments at a lower cost. We hypothesised that there was no learning curve at our academic department when using patient specific templates for TKR instead of the routinely used navigation system.

Material

The first 20 patients operated on for TKR at our academic department using a patient specific template entered the study. All patients had a pre-operative CT-scan planning with a dedicated software.

The patient specific templates were positioned on the bone according to the best fit technique. The position of the templates was controlled at each step of the procedure by the navigation system, and eventually corrected to achieve the expected goal. The discrepancy between the initial and the final positioning was recorded. The paired difference between each set of measurement was analysed with appropriate statistical tests at a 0.05 level of significance.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 145 - 145
1 Jan 2016
Galasso O De Gori M Russo R Gasparini G
Full Access

High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing periprosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians towards alternative antimicrobial formulations to the routinely used antibiotics. To date, few studies simultaneously investigated the elution properties of a broad range of antibiotics. The aim of thepresent in-vitrostudy was to determine the elution kinetics of 14 different high-dose ALACs.

All the ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing overtime, and elution curves strictly adhered to a non-linear regression analysis formula. Among aminoglycosides, commonly addressed as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, commonly used to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution in comparison with teicoplanin. Clindamycin, that can be associated with aminoglycosides to prepare ALACsshowed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multi-drug resistant bacteria.

The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics notroutinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent an useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study.