The origin of surgical site and biomaterial-associated infection is still elusive. Microorganisms contaminating the wound may come from the air, the surgical team, or from the skin of the patient. Prior to surgery the skin of patients is disinfected, but bacteria deeper in the skin ( To study if cutaneous microbiota colonize the wound when released from the skin upon cutting, we isolated, quantified and identified aerobic and anaerobic bacteria from the skin of 99 patients undergoing trauma surgery, before and after skin disinfection, from the knife blades and from the wound directly after the first cut.Aim
Method
The use of medical devices has grown significantly over the last decades, and has become a major part of modern medicine and our daily life. Infection of implanted medical devices (biomaterials), like titanium orthopaedic implants, can have disastrous consequences, including removal of the device. For still not well understood reasons, the presence of a foreign body strongly increases susceptibility to infection. These so-called biomaterial-associated infections (BAI) are mainly caused by Medical grade titanium implants (10×4×1 mm) were dip-coated in a solution of 10% (Aim
Method