header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 258 - 267
1 Jun 2020
Yao X Zhou K Lv B Wang L Xie J Fu X Yuan J Zhang Y

Aims

Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy trauma. In the present study, we aimed to define the distribution and frequency of TPF lines using a 3D mapping technique and analyze the rationalization of divisions employed by frequently used classifications.

Methods

In total, 759 adult patients with 766 affected knees were retrospectively reviewed. The TPF fragments on CT were multiplanar reconstructed, and virtually reduced to match a 3D model of the proximal tibia. 3D heat mapping was subsequently created by graphically superimposing all fracture lines onto a tibia template.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 123 - 123
1 Mar 2017
Zhou K Zhou Z Chen Z Wang D Zeng W Pei F
Full Access

Purpose

The aim of this study was to compare the accuracy of limb alignment and component positioning after total knee arthroplasty(TKA) performed using fixed or individual distal femoral valgus correction angle(VCA)in valgus knees.

Materials and Methods

One hundred and twenty-four patients were randomised to undergo TKA with either of the clinical baseline, radiological outcomes and subsequent outcome such as knee HSS scores, knee range of motion (ROM) and visual analogue scale (VAS) scores were assessed. Knees in the individual group (n=62) were performed with a tailored VCA. Knees in the fixed group (n=62) were performed utilizing a 4°VCA.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 124 - 124
1 Mar 2017
Zhou K Zhou Z Chen Z Wang D Pei F
Full Access

Purpose

Recently many authors have questioned the role of tourniquets in primary knee arthroplasty (TKA). Meanwhile, whether the use of an intra-articular wound drainage is an advance over the lack of a drain in TKA is controversial in the literature. This study aimed to investigate the efficacy and safety of drainage or not in TKA without a tourniquet.

Methods

Eighty participants who underwent primary unilateral TKA were prospectively enrolled and were randomized to one of two techniques during surgery without a tourniquet: drainage (Group A) or non-drainage (Group B). Blood loss was monitored perioperatively. The operating time, allogeneic blood transfusion rate, thigh pain, knee pain, limb swelling, clinical outcome as measured by the hospital for special surgery (HSS) score, the ability to straight-leg raise, visual analog scale (VAS) in pain, length of stay and knee active range of motion (ROM) were also recorded. The digital radiographs taken at 6 months postoperatively were assessed for cement mantle thickness and radiolucency using the Knee Society radiographic zones.