1 Dec 2022
Lapner P Pollock J Hodgdon T Zhang T McIlquham K Coupal S Bouliane M McRae S Dubberley J Berdusco R Stranges G Marsh J Old J MacDonald PB
Full Access

Our primary objective was to compare healing rates in patients undergoing arthroscopic rotator cuff repair for degenerative tears, with and without bone channeling. Our secondary objectives were to compare disease-specific quality of life and patient reported outcomes as measured by the Western Ontario Rotator Cuff Index (WORC), American Shoulder and Elbow Surgeons (ASES) score and Constant score between groups.

Patients undergoing arthroscopic rotator cuff repair at three sites were randomized to receive either bone channeling augmentation or standard repair. Healing rates were determined by ultrasound at 6 and 24 months post operatively. WORC, ASES, and Constant scores were compared between groups at baseline and at 3, 6, 12 and 24 months post operatively.

One hundred sixty-eight patients were recruited and randomized between 2013 to 2018. Statistically significant improvements occurred in both groups from pre-operative to all time points in all clinical outcome scores (p < 0 .0001). Intention to treat analysis revealed no statistical differences in healing rates between the two interventions at 24 months post-operative. No differences were observed in WORC, ASES or Constant scores at any time-point.

This trial did not demonstrate superiority of intra-operative bone channeling in rotator cuff repair surgery at 24 months post-operative. Healing rates and patient-reported function and quality of life measures were similar between groups.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 49 - 49
1 Jul 2020
Lapner P Laneuville O Uhthoff HK Zhang T Howard L Pollock J Ruggiero S Trudel G
Full Access

Tears of the rotator cuff tendons are a very common entity. Despite recent advances in arthroscopic rotator cuff repair, the re-tear rate remains high. Thus, new methods to improve healing rates following rotator cuff repair must be sought. The purpose of this prospective randomized double-blind controlled study is to compare the functional outcomes and healing rates of an adjuvant pre-operative bone microfracture technique prior to arthroscopic cuff repair.

Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a percutaneous bone microfracture of the supraspinatus footprint or a “soft tissue needling” technique, in which the pin was passed through the peripheral edges of the rotator cuff, five-seven days prior to index surgery, under ultrasound guidance. Follow-ups were completed at 3, 6, 12 and 24 months post-operatively. Healing status was determined by ultrasound at 6 and 24 months. The primary objective was to compare the WORC score at 24 months. Secondary objectives included the healing status via ultrasound, the Constant, and the ASES scores. A sample size calculation determined that 90 patients provided 80% power to detect a statistical difference between groups.

Baseline demographic data did not differ between groups. No statistical differences were detected in the WORC outcome at any time points (p=0.47, baseline, p=0.60, 3 months, p=0.79, 6 months, p=0.50, 12 months, p=0.54, 24 months). Healing rates did not differ between groups (P=0.34) and no differences were observed in the ASES or Constant Scores at all time-points. Statistically significant improvements occurred in both groups from baseline to all time points in all clinical outcome scores (p < 0 .0001).

No statistically significant differences in primary or secondary outcomes were identified between pre-operative bone microfracture and soft tissue needling techniques prior to arthroscopic rotator cuff repair. This study does not support pre-operative microfracture as a adjuvant technique prior to arthroscopic cuff repair.