Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 162 - 162
1 May 2012
Hughes J Malone A Zarkadas P Jansen S
Full Access

This study reviews the early results of Distal Humeral Hemiarthroplasty(DHH) for distal humeral fracture and proposed a treatment algorithm incorporating the use of this technique in the overall management of distal humeral fractures.

DHH was performed on 30 patients (mean 65 years; 29-91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A triceps on approach was used in six and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Latitude (Tornier) in 16. Clinical review at a mean of 25 months (3–88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES), Mayo Elbow Performance Index (MEPI) and radiological assessment.

At follow up of 28 patients mean flexion deformity was 25 degrees, flexion 128 degrees, range of pronosupination 165 degrees, mean ASES 83, MEPI 77 and satisfaction 8/10. Acute cases scored better than salvage cases. Re- operation was required in 16 patients (53%); two revisions to a linked prosthesis for periprosthetic fracture and aseptic loosening at 53 and 16 months, 12 metalwork removals and four ulnar nerve procedures. Posterolateral rotatory instability was present in one elbow, four had laxity and mild pain on loading (two with prosthesis or pin loosening), four had laxity associated with column fractures (two symptomatic) and 10 had asymptomatic mild laxity only. The triceps on approach had worse instability and clinical scores. Uncomplicated union occurred in all olecranon osteotomies and 86% of column fractures. One elbow had an incomplete cement mantle and seven had lucencies >1 mm; one was loose but acceptable. Five prostheses were in slight varus. Two elbows had early degenerative changes and 15 developed a medial spur on the trochlea.

This is the largest reported experience of DHH. Early results of DHH show good outcomes after complex distal humeral fractures, despite a technically demanding procedure. Better results are obtained for treatment in the acute setting and with use of an olecranon osteotomy. As a result of this experience anatomical and clinical pre-requisites and advise on technique are outlined. An algorithm for use of DHH in relation to total elbow arthroplasty and ORIF for the treatment of complex intra-articular distal humeral fractures with or without column fractures is proposed.