Although total knee replacement became a widespread procedure for the purpose of knee reconstruction, osteotomies around the knee were regularly performed. Total knee arthroplasty should be performed for advanced arthritis of the knee. With the advent of biplanar open wedge high tibial osteotomy (HTO) combined with locking plate fixation, HTO has been expanded and its surgical outcome has been improved in recent years. However, post-operative joint-line obliquity has been raised as a concern with this procedure, which may affect the outcome especially in the knees with severe varus deformity. Hence the purpose of this study is to analyze the compression and shear stresses in the knee cartilage with joint line obliquity after HTO. Using a three-dimensional computer aided design software, the digital knee model with soft tissues was developed. The geometrical bone data used in this study were derived from commercially available human bone digital anatomy media (3972 and 3976, Pacific Research Laboratories, Inc., WA, USA). The three-dimensional knee model was transferred to finite element model. Material properties of the soft tissues and bones were derived from previous studies. The loading condition was adjusted to the load during a single-leg stance of the gait cycle, which resulted in an axial compressive load of 1200 N. Two different conditions were subjected to the analysis: normal alignment and joint-line obliquity after HTO. For the normal alignment, a static force of 1200 N was applied along the mechanical axis. For the joint-line obliquity models, a single force of 1200 N was applied rotating force directions in the frontal plane from the normal direction by 2.5º, 5º, 7.5º, and 10º, respectively.Introduction
Methods
In recent literatures dealing with optimisation of prosthetic alignment in total hip arthroplasty (THA), the concept of combined anteversion (CA), sum of acetabular anteversion (AV) and femoral antetorsion (AT), has been addressed. We have been using an image-free THA navigation system?OrthoPilot THAPro?to achieve improved overall alignment with both stem and cup. In the use of this system, we have used the stem-first procedure so-called CA technique. In this technique, the femur was prepared first with the target angle corresponding to the native femoral AT and the cup AV was decided considering CA calculated with the formula of Widmer (37.3°= cup AV + 0.7 stem AT). The purpose of this study was to evaluate the accuracy of CA by using CA technique with image-free navigated THA. Fifty hips underwent primary THA using OrthoPilot THApro with CA technique. In CA technique, the femur was prepared first and the target angle of AT value was basically determined by for the individual native femoral AT angle. After the femur was prepared, the cup AV was decided based on the formula of Widmer. All included patients underwent postoperative CT examination, and the prosthetic alignment was assessed using the 3D-Template system (Zed Hip, LEXI).Introduction
Methods
Implant positioning is one of the critical factors influencing the postoperative outcome in total hip arthroplasty (THA). Conventional (manual) intraoperative stem adjustment may result in variability and inaccuracy of stem antetorsion (AT). Since March 2013, we have measured stem antetorsion with CT free Navigation system (OrthoPilot Navigation System THA Pro Ver4.2, B/Braun Aesculap Germany: Navi). We have developed a simple instrument, the Gravity-guide (G-guide), for intraoperative assessment and adjustment of stem AT. We evaluated the accuracy and effectiveness of G-guide and navigation software as referenced to postoperative CT evaluation with 3D template system (Zed hip, LEXI, Japan). Between March 2013 and December 2014, 50 patients underwent primary THA were evaluated. Surgeries were performed with routine techniques with a modified Hardinge approach with the patient at a lateral decubitus position in all cases. The G-guide consists of two parts: one attached to the lower leg and the other attached to the handle of the rasp. During surgery, AT value was determined with navigation at the time of final rasping of the femur. Additionally, the G-guide was utilised at the time of final rasp insertion. In intraoperative AT assessment using this instrument, a correction was required considering the discrepancy between the perpendicular to the posterior condylar axis and the longitudinal axis of the lower leg. The angle of discrepancy between posterior condylar line and femoral trans-epicondyler axis needs to be taken into consideration. Therefore, correction by the angle between the trans-epicondylar and posterior condylar lines (correction angle) was required for each patient when the intraoperative AT as measured by the G-guide. Therefore, the correction angle should be added to the AT value obtained from the G-guide for comparison with postoperative value measured with Zed Hip.Purpose
Method