Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 51 - 51
1 May 2016
Moon K Yang J Yang S
Full Access

Purpose

The results of ceramic-on-ceramic (CoC) bearing surfaces in primary total hip arthroplasty (THA) were well known. However, it was not known in revision THA. The purpose of this study is to report the results of revision THA with ceramic articulation.

Materials and Methods

112 revision THAs with ceramic articulation were evaluated. The mean age at the time of surgery was 58.3 years (28 to 97). The mean duration of the follow-up periods was 6.4 years (2 to 11.8 years).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 140 - 140
1 Jan 2016
Yang J Yoon JR
Full Access

Purpose

In vivo comparative gap measurements were performed in 3 different patella positions (reduced, subluxated and everted) using offset-type-force-controlled-spreader-system.

Methods

Prospectively, 50 knees were operated by TKA using a navigation-assisted gap balancing technique. The offset-type-force-controlled-spreader-system was used for gap measurements. This commercially-available instrument allows controllable tension in patella reduced position. The mediolateral gaps of knee extension (0°) and flexion (90°) angle were recorded in 3 different patella positions; reduced, subluxated and everted. Any gap differences of more than 3 mm were considered as a meaningful difference. Correlation between the difference with the demographic data, preoperative radiologic alignment and intraoperative data was analyzed. For statistical analysis, ANOVA and Pearson correlation test were used.


The purpose of this prospective randomized study was to compare the visible, hidden, total blood loss and postoperative haemodynamic change of subcutaneous and intra-articular indwelling closed suction drainage method after total knee arthroplasty (TKA). Patients with primary osteoarthritis, who underwent unilateral TKA were enrolled; Group A with subcutaneous (n=78) and group B with intra-articular (n=79) indwelling closed suction drainage method. Total blood loss, visible blood loss, internal blood loss, postop (day 1), 5th, 10th day hemoglobin, hematocrit levels were compared. Allogenic blood transfusion rate and complications related to soft tissue hematoma formation were additionally compared. Subcutaneous indwelling closed suction drainage method reduced both the visible blood loss and total blood loss (hemovac drainage + internal blood loss) thus decreasing the rate of allogenic transfusion. Although the minor complications such as the incidence of bullae formation and the ecchymosis were higher in the subcutaneous indwelling group, the functional outcome at postoperative 2 year did not demonstrate difference from intra-articular drainage group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 370 - 370
1 Mar 2013
Zhou C Zhou Z He J Sun J Shen B Yang J Kang P Pei F
Full Access

Background

Recent anthropometric studies have suggested that current design of total knee arthroplasty (TKA) does not cater to racial anthropometric differences. The purpose of this study was to investigate the exact sizing and rotational landmarks of the distal femur collected and its gender differences from a large group of healthy Southern Chinese using 3D-CT measurements, and then compare these measurements to the five total knee prostheses conventionally used in China.

Methods

This study evaluated distal femoral geometry in 85 healthy Southern Chinese, included 39 females (78 knees) and 46 males (92 knees) with a mean age of 33.9 years,a mean height of 164.7 cm and a mean weight of 59.9 kg. The width of the articular surface as projected onto the transepicondylar line(ML), anteroposterior dimension (AP), the dimensions from medial/lateral epicondyle to posterior condylar (MEP/LEP) were measured. A characterization of the aspect ratio (ML/AP) was made for distal femur. The angles between the tangent line of the posterior condylar surfaces, the Whiteside line, the transepicondylar line, and the trochlear line were measured. The sulcus angle and hip center-femoral shaft angle were also measured [Fig. 1]. The data were compared with the five total knee prostheses conventionally used in China. In analyzing the data, best-fit lines were calculated with use of least-squares regression. The dimensions are summarized as the mean and standard deviation. Comparisons of dimensions between males and females were made with use of the two-sample t test. A p value of <0.05 indicated a significant effect.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 63 - 63
1 Sep 2012
Wong M Yu Y Yang J Walsh W
Full Access

The purpose of this study was to understand the effects of terminal sterilisation and residual calcium on human demineralised bone matrix (DBM) in ectopic bone formation in nude rat.

The intramuscular implantation of human DBM prepared by the Queensland Bone Bank (QBB) from four donors into eight male athymic rats was used to assess osteoinductivity. The DBM contained different levels of residual calcium and treated with or without gamma-irradiation at 11kGy. At 6 weeks post-implantation, calcium deposition was assessed by manual palpitation and radiological imaging. Tissue morphology and cellular interactions was analysed using various histological staining methods whilst protein expression of anabolic and catabolic biomarkers were examined through immunohistochemistry. All results were then analysed in qualitative, semi-quantitative and quantitative manners and tested for statistical significance.

Bone formation was observed in all specimens at the gross level. This was confirmed by histology which revealed bony capsules surrounded by soft tissue in the muscle pockets and differences in tissue components. On a cellular level, variations in osteoclast expression were found between the two groups as well as amongst individual donors through statistical analysis which resulted in an imbalance of the expression of anabolic and catabolic markers. Furthermore, a positive relationship between residual calcium and new bone formation in gamma irradiated DBM samples was found. To date, no studies have compared the effect of calcium in gamma irradiated DBM.

Our results suggest that gamma irradiation even at low doses and residual calcium may affect new bone formation. Taken together, this study stresses the importance of selecting ideal conditions for graft processing and the need to identify an optimal level of irradiation and remaining calcium levels that confers a balance between osteoinductivity and sterility.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 224 - 224
1 Sep 2012
Zhou Z Zhou C Shen B Yang J Kang P Pei F
Full Access

Background

Recent anthropometric studies have suggested that current design of total knee arthroplasty (TKA) does not cater to racial anthropometric differences. The purpose of this study was to investigate the exact sizing and rotational landmarks of the distal femur collected from a large group of healthy Southern Chinese using three dimensional computer tomographic measurements, and then compare these measurements to the known dimensions from Caucasian populations.

Methods

This study evaluated distal femoral geometry in 125 healthy Southern Chinese, included 58 women (106 knees) and 67 men (134 knees) with a mean age of 35.2±8.11 years, a mean height of 165.5±7.94 cm, and a mean weight of 61.7±9.56 kg. The width of the articular surface as projected onto the transepicondylar line(ML), anteroposterior dimension (AP), the dimensions from medial/lateral epicondyle to posterior condylar (MEP/LEP)were measured. A characterization of the aspect ratio (ML/AP) was made for distal femur[Fig. 1]. The angles between the tangent line of the posterior condylar surfaces, the Whiteside line, the transepicondylar line, and the trochlear line were measured. The sulcus angle and hip center-femoral shaft angle were also measured. Known dimensions from Caucasian populations were compared with the morphologic data collected in this study[Fig. 2]. In analyzing the data, best-fit lines were calculated with use of least-squares regression. The dimensions are summarized as the mean and standard deviation. The differences of rotational landmarks and sizing between the Southern Chinese and Caucasians were assessed with use of the Student t test. A p value of <0.05 indicated a significant effect.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 32 - 32
1 Sep 2012
Yu Y Luk F Yang J Walsh W
Full Access

To set up an osteosarcoma mouse model with spontaneous lung metastasis and to identify a marker of osteosarcoma metastasis and to inhibit the marker against the invasive ability of an osteosarcoma cell line.

A human osteosarcoma orthotopic mouse model was set up by injecting 143B human osteosarcoma cells into mouse tibia. Type I insulin-like growth factor receptor (IGF-1R) and its downstream signalling factors were measured in samples from the primary tumor and the lung secondaries by immunohistochemistry. Human Alu mRNA expression was tested using in situ hybridization assay. A Matrigel assay was used to assess cell invasion ability under the interference of a MEK/ERK pathway specific inhibitor, U0126.

All fifteen mice showed tumour mass at the left tibia and lung metastasis. Human Alu expression in the primary and secondary tumours confirmed human origin of the tumour cells. Total IGF-1R, MEK, Akt, p38 and phosphorylated MEK (p-MEK), but not p-Akt and p-p38, were positive in both local tumours and lung secondaries. Leiomyosarcoma controls expressed p-Akt and p-MEK, but not p-p38. The 143B cells treated with U0126 had significantly lower in vitro invasion ability compared with controls.

The IGF-1R-MEK signalling pathway, particularly Ras/Raf/MEK/ERK, may play an important role in osteosarcoma lung metastasis, and the targeting MEK/ERK by its specific inhibitor may have a potential use in the effective treatment of osteosarcoma.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 171 - 171
1 Sep 2012
Shen B Lai O Yang J Pei F
Full Access

Background and Objective

Total hip arthroplasty (THA) has been applied to treat pain and disability in patients with post-traumatic arthritis after acetabular fracture for many years. However, the midterm and long-term results of THA for this unique population are still controversial. According to previous studies, we found that uncemented acetabular reconstructions were usually performed in patients who were most likely to have the best results and an abnormal acetabular structure was usually the reason for THA failure. In this study, we evaluated the midterm results of using uncement acetabular components to treat posttraumatic arthritis after acetabular fracture. In addition, we investigated the effects of different acetabular fracture treatments and fracture patterns on THA.

Materials and Methods

Between January 2000 to December 2003, 34 uncemented acetabular reconstructions were performed in 34 patients for posttraumatic arthritis after acetabular fractures. Among them, 31 patients underwent complete clinical and radiographic follow-up for an average of 6.3 years (range, 3.1–8.4 years). There were 22 men and 9 women. The patients' average age was 51 ± 12 years (range, 27–74 years) at the time of arthroplasty. The average interval from fracture to THA was 5.58 ± 4.42 years (range, 0.75–17.5 years). Of the 31 patients, 19 had undergone ORIF (open-reduction group) and 12 had received conservative treatment for the acetabular fractures (conservative-treatment group). Then, 14 had simple pattern fractures (simple group) and 17 had complex pattern fractures (complex group). After midterm follow-up, the radiographic and clinic results of the different groups were compared.