Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 42 - 42
1 Aug 2021
Wyatt M Frampton C Whitehouse M Deere K Sayers A Kieser D
Full Access

The aim of this study was to compare the relative performance of total hip replacement constructs and discern if there is substantial variability in performance in currently commonly used prostheses.

All patients who underwent a primary total hip replacement (THR) registered in the NZJR between 1st January 1999 to June 2020 were identified. Using a noninferiority analysis, the performance of hip prostheses were compared with the best performing contemporary construct. Construct failure was estimated using the 1-Kaplan Meier survival function method to estimate net failure. The difference in failure between the contemporary benchmark and other constructs was examined.

In total 135 432 THR were recorded comprising 1 035 different THR constructs. Notably 328 constructs were used just once. 48 constructs (62 251 THR) had >500 procedures at risk at 3 years post-primary of which 28 were inferior by at least 20% relative risk of which, 10 were inferior by at least 100% relative risk. 16 constructs were identified with >500 procedures at risk at 10 years with 9 inferior by at least 20%, of which one was inferior by >100% relative risk. There were fewer constructs noninferior to the best practice benchmark when we performed analysis by gender. In females at 10 years, from 5 constructs with >500 constructs at risk, 2 were inferior at the 20% margin. In males at 10 years, there were only 2 eligible constructs of which one was inferior at the 20% margin.

We discerned that there is substantial variability in construct performance and at most time points, just over half of constructs are inferior to the best performing construct by at least 20%. These results can facilitate informed decision-making when considering THR surgery.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 27 - 27
1 Jul 2020
Wyatt M Whitehouse M Kieser D Frampton C Hooper G
Full Access

Background

Reduced dislocation rates using lipped polyethylene (PE) liners in modular uncemented acetabular components has been shown, yet there may be increased wear because of impingement, which may lead to aseptic loosening. We used New Zealand Joint Registry (NZJR) data to compare survival rates, revision rates for dislocation and aseptic loosening between lipped and neutral liners.

Methods

31,247 primary THAs using the four commonly used uncemented modular cups were identified (January 1, 1999 to December 31, 2018). The lipped liner group comprised 49% males vs 42% in the neutral group (p < 0.001); 96% had OA vs 95% in the neutral group (p < 0.001). There was no difference in other patient characteristics. Mean follow-up was 5.1 years (SD 3.9); longest follow-up 19.3 years. Kaplan Meier survival rates were compared (20,240 lipped and 11,007 neutral PE liners). Highly cross-linked PE was used in 99% of lipped liner cups vs 85% of neutral liner cups. Associated hazard ratios were calculated using a Cox regression analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1578 - 1584
1 Dec 2019
Batailler C Weidner J Wyatt M Pfluger D Beck M

Aims

A borderline dysplastic hip can behave as either stable or unstable and this makes surgical decision making challenging. While an unstable hip may be best treated by acetabular reorientation, stable hips can be treated arthroscopically. Several imaging parameters can help to identify the appropriate treatment, including the Femoro-Epiphyseal Acetabular Roof (FEAR) index, measured on plain radiographs. The aim of this study was to assess the reliability and the sensitivity of FEAR index on MRI compared with its radiological measurement.

Patients and Methods

The technique of measuring the FEAR index on MRI was defined and its reliability validated. A retrospective study assessed three groups of 20 patients: an unstable group of ‘borderline dysplastic hips’ with lateral centre edge angle (LCEA) less than 25° treated successfully by periacetabular osteotomy; a stable group of ‘borderline dysplastic hips’ with LCEA less than 25° treated successfully by impingement surgery; and an asymptomatic control group with LCEA between 25° and 35°. The following measurements were performed on both standardized radiographs and on MRI: LCEA, acetabular index, femoral anteversion, and FEAR index.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 712 - 719
1 Jun 2018
Batailler C Weidner J Wyatt M Dalmay F Beck M

Aims

The primary aim of this study was to define and quantify three new measurements to indicate the position of the greater trochanter. Secondary aims were to define ‘functional antetorsion’ as it relates to abductor function in populations both with and without torsional abnormality.

Patients and Methods

Three new measurements, functional antetorsion, posterior tilt, and posterior translation of the greater trochanter, were assessed from 61 CT scans of cadaveric femurs, and their reliability determined. These measurements and their relationships were also evaluated in three groups of patients: a control group (n = 22), a ‘high-antetorsion’ group (n = 22) and a ‘low-antetorsion’ group (n = 10).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 6 - 6
1 Jun 2017
Wyatt M Weidner J Pfluger D Beck M
Full Access

The definition of osseous instability in radiographic borderline dysplastic hips is difficult. A reliable radiographic tool that aids decision-making specifically, a tool that might be associated with instability-therefore would be very helpful for this group of patients. The aims of this study were:

(1) To compare a new radiographic measurement, which we call the Femoro-Epiphyseal Acetabular Roof (FEAR) index, with the lateral centre-edge angle (LCEA) and acetabular index (AI), with respect to intra- and interobserver reliability; (2) to correlate AI, neck-shaft angle, LCEA, iliocapsularis volume, femoral antetorsion, and FEAR index with the surgical treatment received instable and unstable borderline dysplastic hips; and (3) to assess whether the FEAR index is associated clinical instability in borderline dysplastic hips.

We defined and validated the FEAR index in 10 standardized radiographs of asymptomatic controls using two blinded independent observers. Interrater and intrarater coefficients were calculated, supplemented by Bland-Altman plots. We compared its reliability with LCEA and AI. We performed a case-control study using standardized radiographs of 39 surgically treated symptomatic borderline radiographically dysplastic hips and 20 age-matched controls with asymptomatic hips (a 2:1 ratio), the latter were patients attending our institution for trauma unrelated to their hips but who had standardized pelvic radiographs between January 1, 2016 and March 1, 2016.

Patient demographics were assessed using univariate Wilcoxon two-sample tests. There was no difference in mean age (overall: 31.5 ± 11.8 years [95% CI, 27.7–35.4 years]; stable borderline group: mean, 32.1± 13.3 years [95%CI, 25.5–38.7 years]; unstable borderline group: mean, 31.1 ± 10.7 years [95% CI, 26.2–35.9 years]; p = 0.96) among study groups. Treatment received was either a periacetabular osteotomy (if the hip was unstable) or, for patients with femoroacetabular impingement, either an open or arthroscopic femoroacetabular impingement procedure. The association of received treatment categories with the variables AI, neck-shaft angle, LCEA, iliocapsularis volume, femoral antetorsion, and FEAR index were evaluated first using Wilcoxon two-sample tests (two-sided) followed by stepwise multiple logistic regression analysis to identify the potential associated variables in a combined setting. Sensitivity, specificity, and receiver operator curves were calculated. The primary endpoint was the association between the FEAR index and instability, which we defined as migration of the femoral head either already visible on conventional radiographs or recentering of the head on AP abduction views, a break of Shenton's line, or the appearance of a crescent-shaped accumulation of gadolinium in the posteroinferior joint space at MR arthrography.

The FEAR index showed excellent intra- and interobserver reliability, superior to the AI and LCEA. The FEAR index was lower in the stable borderline group (mean, −2.1 ± 8.4; 95% CI, −6.3 to 2.0) compared with the unstable borderline group (mean, 13.3 ± 15.2; 95% CI, 6.2–20.4) (p < 0.001) and had the highest association with treatment received. A FEAR index less than 5° had a 79% probability of correctly assigning hips as stable and unstable, respectively (sensitivity 78%; specificity 80%).

A painful hip with a LCEA of 25° or less and FEAR index less than 5° is likely to be stable, and in such a situation, the diagnostic focus might more productively be directed toward femoroacetabular impingement.