Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 49 - 49
1 Feb 2012
Wimsey S Lien C Sharma S Brennan P Harper G Gorecki D
Full Access

Introduction

Osteoarthritis (OA) has historically been thought of as a degenerative joint disease, but inflammation and angiogenesis are increasingly being recognised as contributing to the pathogenesis, symptoms and progression of OA. b-dystroglycan (b-DG) is a pivotal element of the transmembrane adhesion molecule involved in cell-extracellular matrix adhesion and angiogenesis. Matrix metalloproteinases (MMPs) are the main enzymes responsible for cartilage extracellular matrix breakdown and are also implicated in both angiogenesis and b-DG degradation in a number of malignancies. We aimed to investigate the expression and localisation of b-DG and MMP-3, -9, and -13 within cartilage, synovium and synovial fluid and establish their roles in the pathogenesis of OA.

Methods

Following ethical committee approval, cartilage, synovium and synovial fluid were obtained from the hip joints of 5 osteoarthritic (patients undergoing total hip replacement) and 5 control hip joints (patients undergoing hemiarthroplasty for femoral neck fracture). The samples were analysed for b-DG expression using Western Blotting and for the distribution of b-DG, MMP-3, -9, and -13 using immunohistochemistry on paraffin embedded tissue.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery.