Vol. 99-B, Issue SUPP_3 | Pages 76 - 76
1 Feb 2017
Cobb J Wiik A Brevadt MJ Auvinet E Van Der Straeten C
Full Access

Intro

Across much of medicine, activity levels predict life expectancy, with low levels of activity being associated with increased mortality, and higher levels of activity being associated with longer healthier lives. Resurfacing is a technically demanding procedure that has suffered significant fallout from the failure of a couple of poorly performing designs. However strong evidence associates resurfacing with improved life expectancy in both the short and longer term following surgery.

We wondered if there was any relationship between the function of hips following surgery and the extent of that surgery. Could a longer stem inside the femur be the reason for a slightly reduced step length? We proposed the nul hypothesis that there was no clinically relevant difference between stem length and gait.

Method

After informed consent each subject was allowed a 5 minute acclimatisation period at 4km/hr on the instrumented treadmill (Kistler Gaitway, Amherst, NY). Their gait performance on an increasing incline at 5, 10 and 15%. At all 0.5km incremental intervals of speed, the vertical component of the ground reaction forces, center of pressure and temporal measurements were collected for both limbs with a sampling frequency of 100Hz over 10sec.

They were also asked to log onto our JointPRO website and report their function using Oxford, EQ5D, and Imperial scores.

Owing to current restrictions in indications, the patient groups selected were not comparable. However, from our database of over 800 patients who have been through the gait lab. 82 subjects were tested from 2 diagnostic groups (29 conventional THR, 27 hip resurfacing) and compared with a slightly younger group of 26 healthy controls. Patients were excluded if less than 12 months postop, or with any other documented joint disease or medical comorbidities which might affect gait performance.

Body weight scaling was also applied to the outputted mechanical data to correct for mass differences. All variables for each subject group were compared to each other using an analysis of variance (ANOVA) with Tukey post hoc test with significance set at α=0.05.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 34 - 34
1 Feb 2017
Brevadt MJ Wiik A Aqil A Auvinet E Loh C Johal H Van Der Straeten C Cobb J
Full Access

Introduction

Financial and human cost effectiveness is an increasing evident outcome measure of surgical innovation. Considering the human element, the aim is to restore the individual to their “normal” state by sparing anatomy without compromising implant performance. Gait lab studies have shown differences between different implants at top walking speed, but none to our knowledge have analysed differing total hip replacement patients through the entire range of gait speed and incline to show differences. The purpose of this gait study was to 1) determine if a new short stem femoral implant would return patients back to normal 2) compare its performance to established hip resurfacing and long stem total hip replacement (THR) implants.

Method

110 subjects were tested on an instrumented treadmill (Kistler Gaitway), 4 groups (short-stem THR, long-stem THR, hip resurfacing and healthy controls) of 28, 29, 27, and 26 respectively. The new short femoral stem patients (Furlong Evolution, JRI) were taken from the ongoing Evolution Hip trial that have been tested on the treadmill minimum 12months postop. The long stem total hip replacements and hip resurfacing groups were identified from our 800+ patient treadmill database, and only included with tests minimum 12 months postop and had no other joint disease or medical comorbidities which would affect gait performance.

All subjects were tested through their entire range of gait speeds and incline after having a 5 minute habituation period. Speed were increased 0.5kmh until maximum walking speed achieved and inclines at 4kmh for 5,10,15%. At all incremental intervals of speed 10seconds ere collected, including vertical ground reaction forces (normalized to body mass), center of pressure and temporal measurements were for both limbs (fs=100Hz). Symmetry Index(SI) were calculated on a range of features comparing leg with implanted hip to the contralateral normal hip. Group means for each feature for each subject group were compared using an analysis of variance (ANOVA) with Tukey post-hoc test with significance set at α=0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 58 - 58
1 May 2016
Brevadt M Manning V Wiik A Aqil A Dadia S Cobb J
Full Access

Introduction

Femoral component design is a key part of hip arthroplasty performance. We have previously reported that a hip resurfacing offered functional improved performance over a long stem. However resurfacing is not popular for many reasons, so there is a growing trend towards shorter femoral stems, which have the added benefit of ease of introduction through less invasive incisions. Concern is also developing about the impact of longer stems on lifetime risk of periprosthetic fracture, which should be reduced by the use of a shorter stem. For these reasons, we wanted to know whether a shorter stem offered any functional improvement over a conventional long stem. We surmised that longer stems in hip implants might stiffen the femoral shaft, altering the mechanical properties.

Materials and Methods

From our database of over 800 patients who have been tested in the lab, we identified 95 patients with a hip replacement performed on only one side, with no other lower limb co-morbidities, and a control group:

19 with long stem implant, age 66 ± 14 (LONG)

40 with short stem implant, age 69 ± 9 (SHORT)

26 with resurfacing, age 60 ± 8 (RESURF)

43 healthy control with no history of arthroplasty, age 59 ± 10 (CONTROL)

All groups were matched for BMI and gender.

Participants were asked to walk on an instrumented treadmill. Initially a 5 minute warm up at 4 km/h, then tests at increasing speed in 0.5 km/h increments. Maximum walking speed was determined by the patients themselves, or when subjects moved from walking to running.

Ground reaction forces (GRF) were measured in 20 second intervals at each speed. Features were calculated based on the mean GRF for each trial, and on symmetry measures such as first peak force (heel strike), second peak force (toe-off), the rate at which the foot was loaded and unloaded, and step length.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 89 - 89
1 May 2016
Cobb J Collins R Wiik A Brevadt M Auvinet E Manning V
Full Access

Any arthroplasty that offers superior function needs to be assessed using metrics that are capable of detecting those functions. The Oxford Hip Score (OHS), the Harris Hip Score (HHS) and WOMAC are patient reported outcome measures (PROMs) with well documented ceiling effects: following hip arthroplasty, many patients are clustered close to full marks following surgery. Two recent well conducted randomised clinical trials made exactly this error, by using OHS and WOMAC to detect a differences in outcome between hip resurfacing and hip arthroplasty despite published data already showing in single arm studies that these two procedures score close to full marks using either of these PROMS.

We have already reported that patients with hip resurfacing arthroplasty (HRA) were able to walk faster and with more normal stride length than patients with well performing hip replacements. In an attempt to relate this functional superiority to an outcome measure that does not rely upon the use of expensive machinery, we developed a patient centred outcome measure (PCOM) based upon a method developed by Philip Noble's group, and the University of Arizona's Metabolic Equivalent of Task Index (MET). This PCOM allows patients to select the functions that matter to them personally against which the success of their own operation will be measured, with greater sensitivity to intensity than is achieved by the UCLA.

Our null hypothesis was that this PCOM would be no more successful than the PROMs in routine use in discriminating between types of hip arthroplasty, and that there would be no difference in gait between patients following these procedures.

From our database of over 800 patients whose gait has been assessed in the lab, we identified 22 patients with a well performing conventional THAs, and matched them for age, sex, BMI, height, preop diagnosis with 22 patients with a well performing conventional THA. Both were compared with healthy controls using the novel PCOM and in a gait lab.

Results

PROMs for the two groups were almost identical, while HRA scored higher in the PCOM. The 9% difference was significant (p<0.05). At top walking speed, HRA were 10% faster, with a 9% longer stride length, both of these metrics also reached significance.

Discussion

Function following hip replacement is very good, with high satisfaction rates, but the use of a PCOM, and objective measures of function reveal substantial inferiority of THA over THR in two well matched groups. This 9% difference is well over the 5% difference that is considered ‘clinically relevant’. When coupled with the very strong data regarding life expectancy and infection, this functional data makes a compelling case for the use of resurfacing in active adults.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 91 - 91
1 Jan 2016
Cobb J Boey J Manning V Wiik A
Full Access

Introduction

Our primary hypothesis was simple: does gait on a downhill gradient distinguish between types of knee arthroplasty? Our secondary hypotheses were these: are stride length and other kinematic variables affected by cruciate ligament integrity following knee arthroplasty?

Participants

Ethical approval was sought and gained prior to commencement of the study. 52 subjects were tested on the instrumented treadmill, 3 groups (UKA, TKA, and young healthy control) of 19, 14, and 19 respectively. The two high performing arthroplasty groups were recruited from a database of patient related outcome measures (PROMs) and were chosen based on high Oxford knee scores (OKS) with a minimum 12 months post hip arthroplasty.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2013
Wiik A Tankard S Lewis A Krishnan S Amis A Cobb J
Full Access

Background

High functional aspirations and an active ageing population equate to a growing number of patients awaiting hip arthroplasty demanding superior biomechanical function. The purpose of this study was to compare the biomechanics of top walking speed between two commonly used hip arthroplasty procedures to determine if a performance advantage existed.

Methods

A retrospective comparative study was performed using sixty-seven subjects, twenty-two subjects in both hip resurfacing and total hip arthroplasty groups along with twenty-three healthy controls. All arthroplasty subjects were recruited based on high psychometric scoring and had been performed through a posterior approach, and had been discharged from follow-up. On an instrumented treadmill each subject was measured by a researcher blinded to which procedure that patient had undergone. After a six minute acclimatization period, the speed was increased incrementally until top walking performance had been attained. At all increments, ground reaction forces and temporospatial measurements were collected.