Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 137 - 137
1 Mar 2017
Schaller G Waters T Davies N Whittingham-Jones P
Full Access

Introduction

Trabecular titanium implants are 3D printed with a high-friction ingrowth surface that is continuous with the rest of the acetabular shell. The ability to “face-change” following optimum seating of the component allows unprecedented levels of versatility in acetabular orientation. Bolt-on augments enable rapid trialling and definitive insertion of a monobloc construct. The use of these implants has rapidly increased in the National Joint Registry over the last three years with little published outcome data. We present one of the largest studies using this material.

Objectives

This study assesses the early stability, ingrowth and clinical outcome of revision acetabular reconstruction with trabecular titanium.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 24 - 24
1 Jan 2016
St Mart J Whittingham-Jones P Davies N Waters T
Full Access

Introduction

Bone loss in the distal femur and proximal tibia is frequently encountered with both complex primary and revision knee replacement surgery. Metaphyseal sleeves provide a good option for enhanced fixation in managing such defects on both the tibia and femur. We present our results in 48 patients (50 knees) with a minimum 12 month follow up (range 12 to 45).

Methods

48 patients (50 knees) who had revision knee arthroplasty for either septic or aseptic loosening. All were graded Type II or III using the Anderson Orthopaedic Research Institute (AORI) grading system of both femoral and tibial defects. A large portion of aseptic loosening revisions were for extreme osteolysis of a bicondylar knee prosthesis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 104 - 104
1 Jan 2013
Patel N Luff T Whittingham-Jones P Iliadis A Gooding C Hashemi-Nejad A
Full Access

Total hip arthroplasty (THA) in teenagers is uncommon and previously associated with poor survival rates. However it is sometimes the only option remaining to relieve pain and improve function in patients with advanced hip disease. We report on the clinical and radiological outcomes of THA in teenage patients. Medical records and radiographs of all consecutive teenage patients undergoing THA at a tertiary referral centre between 2006–2011 were reviewed. Mean follow-up was 3.4 years (range 0.6–6.8) with 9 patients having at least 5 years follow-up. Post-operative Harris hip, Oxford hip (OHS) and University of California Los Angeles (UCLA) activity scores were recorded. 51 THAs were performed in 43 patients (21 male, 22 female) with a mean age of 17 years (range 12–19). The 5 most common indications were slipped upper femoral epiphysis osteonecrosis 15 (29.4%), developmental hip dysplasia osteonecrosis 5 (9.8%), multiple/spondylo-epiphyseal dysplasia 5 (9.8%), chemotherapy-induced osteonecrosis 4 (7.8%) and idiopathic osteonecrosis 4 (8.2%). 46 (90%) were uncemented THAs and 5 (10%) were reverse hybrid THAs with 7 computer assisted design/manufacture (CADCAM) femoral implants. Articular bearings were ceramic/ceramic in 40 (78.4%), metal/metal 6 (11.8%), metal/polyethylene 3 (5.9%) and ceramic/polyethylene 2 (3.9%). The survival rate was 96% with 2 acute head revisions for 1 sciatic nerve palsy and 1 instability. Other complications (8.2%) included 1 dislocation, 1 sciatic nerve palsy that resolved, 1 surgical site infection and 1 unexplained pain. At latest follow-up, the mean Harris hip score was 90 (68–99), OHS was 42 (32–48) and UCLA activity score was 6 (4–9). Radiological analysis showed 2 patients with lucent lines around the acetabular component, but no signs of osteolysis or wear. As one of the largest studies on teenagers undergoing THA, we report good clinical and radiological outcomes at short to intermediate term follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 69 - 69
1 Aug 2012
Picardo N Nawaz Z Gallagher K Whittingham-Jones P Parratt T Briggs T Carrington R Skinner J Bentley G
Full Access

The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure.

With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively.

An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 570 - 573
1 Apr 2012
Whittingham-Jones P Mann B Coward P Hart AJ Skinner JA

Fracture of a ceramic component in total hip replacement is a rare but potentially catastrophic complication. The incidence is likely to increase as the use of ceramics becomes more widespread. We describe such a case, which illustrates how inadequate initial management will lead to further morbidity and require additional surgery. We present the case as a warning that fracture of a ceramic component should be revised to another ceramic-on-ceramic articulation in order to minimise the risk of further catastrophic wear.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 62 - 62
1 Feb 2012
Dunstan E Ladon D Whittingham-Jones P Cannon S Briggs T Case P
Full Access

Purpose

Metal-on-Metal (MoM) hip bearings are being implanted in ever-increasing numbers and into ever-younger patients. The consequence of chronic exposure to metal ions is a cause for concern. Therefore, using cytogenetic biomarkers, we investigated a group of patients who have had MoM bearings in situ for in excess of 30 years.

Method

Whole blood specimens were obtained from an historical group of patients who have had MoM bearings in situ for in excess of 30 years. Blood was also obtained from an age and sex matched control group and from patients with Metal-on-Polyethylene (MoP) components of the same era. The whole blood was cultured with Pb-Max karyotyping medium and harvested for cytogenetics after 72 hrs. The 24 colour FISH (Fluorescent In Situ Hybridisation) chromosome painting technique was performed on the freshly prepared slides, allowing chromosomal mapping. Each slide was evaluated for chromosomal aberrations (deletions, fragments and translocations) against the normal 46 (22 pairs and two sex) chromosomes. At least 20 metaphases per sample were scored and the number of aberrations per cell calculated.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 363 - 364
1 Jul 2008
Dunstan E Ladon D Whittingham-Jones P Cannon S Case P Briggs T
Full Access

Background: Metal-on-Metal (MoM) hip bearings are being implanted in ever increasing numbers and into ever-younger patients. The consequence of chronic exposure to metal ions is a cause for concern. Therefore, by using cytogenetic biomarkers, we investigated a group of patients who have had MoM bearings in-situ for in excess of 30 years.

Method: Whole blood specimens were obtained from an historical group of patients who have had MoM bearings in-situ for in excess of 30 years. Blood was also obtained from an age and sex matched control group and from patients with Metal-on-Polyethylene (MoP) components of the same era.

The whole blood was cultured with Pb-Max karyotyping medium and harvested for cytogenetics after 72 h. The 24 colour FISH (Fluorescent In Situ Hybridisation) chromosome painting technique was performed on the freshly prepared slides allowing chromosomal mapping. Each slide was evaluated for chromosomal aberrations (deletions, fragments and translocations) against the normal 46 (22 pairs and two sex) chromosomes. At least 20 metaphases per sample were scored and the number of Aberrations per cell calculated.

Results: Chromosomal aberrations, including deletions, fragments and translocations were only detected in the peripheral blood lymphocytes isolated from the group that had MoM bearings. These changes were not present in the age and sex matched control group. The chromosomal aberrations were also detected in the patients previously exposed to MoM bearings who have been revised to a MoP articulation.

Conclusion: We have detected dramatic chromosomal aberrations in peripheral blood lymphocytes in a group of patients chronically exposed (over 30 years) to elevated metal ions. It is not known whether these aberrations have clinical consequences or whether they are reproduced in other cells in the body. The results emphasise the need for further investigations into the effect of chronic exposure to elevated metal ions produced by Orthopaedic implants.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 409 - 409
1 Oct 2006
Caruana J Hon C Whittingham-Jones P Briggs T Blunn G
Full Access

Introduction A consensus exists regarding the optimal range of femoral cement mantle thickness in hip replacement. However, within this range surgical preferences differ, surgeons in Europe generally preferring thinner cement mantles whilst those in the US prefer a thicker mantle. For a given implant size, the rasps provided in the US for use with the Stanmore Hip are larger than those used in Europe, producing a thicker cement mantle. The integrity of the femoral cement is considered to be crucial to the long-term survival of cemented hip replacements. Previous studies have used cement cracking under fatigue loading as a comparative measure of implant survival. Damage accumulation levels between different implants are associated with clinical failure rates. The aim of this study was to compare the cracking behaviour of cement mantles of different thicknesses around Stanmore Hip replacements. We hypothesised that a thicker cement mantle would lead to reduced cement cracking.

Methods Ten synthetic femurs (Sawbones) were prepared following standard surgical practice for the Stan-more Hip. Five of these were rasped using the larger US rasp, and five using the European version. Stanmore Hip femoral components were then cemented into the femurs with Palacos-R cement and using a custom insertion rig to ensure good alignment and centralisation, confirmed by radiographs. The femurs were then cyclically loaded with an aggressive 4 kN stair-climbing load for 4 million cycles at 3 Hz. The femurs were sectioned at 5 mm intervals and dye penetrant used to highlight cement cracks. Image analysis software was used to measure cement thickness and crack lengths under light microscopy.

Results The minimum cement mantle thickness per section was found to average 0.8 mm and 2.0 mm for the thin and thick mantle groups respectively, measured around the proximal half of the implant. This was significantly different (p< 0.05). Cracks in the cement mantle were irregularly distributed along the length of the prostheses. We found no significant difference in either the total number or total length of cracks found in each group. These were investigated over the whole mantle and by Gruen Zone.

Discussion The geometric and mechanical properties of human femurs vary considerably, which might be expected to increase dramatically the scatter in any clinical trend relating cement thickness to cracking. Our study, using identical synthetic femurs and well-centralised prostheses to minimise experimental variability, found no difference in cracking. Given this experimental consistency, it is thought that there would be no clinically significant difference in cracking rates between different cement thicknesses within the normal range for the Stanmore Hip replacement. The Stanmore Hip is designed to minimise cement stress. A collar prevents subsidence-related hoop stresses, and smooth corners minimise stress concentration in the cement. It is likely that, for a sub-optimal implant design with higher stress risers, cement thickness might have a more noticeable effect on crack propagation.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 292 - 292
1 May 2006
Whittingham-Jones P Sanghrajka A Briggs T Cannon S
Full Access

Introduction: Chondrosarcoma is the second most common malignant solid tumour of bone. The management of extra-axial low grade chondrosarcomas remains a controversial issue. Many groups advocate wide excision, necessitating substantial reconstructive surgery, often requiring massive endoprostheses or allografts. Our unit favours intralesional curettage, as it is less invasive and results in smaller defects affecting only the medulla, which can be reconstructed using simpler methods. The purpose of this study was to assess the oncological and functional outcomes of this treatment strategy.

Methods: Using our database, we identified patients with long bone chondrosarcoma that had undergone intralesional curettage between 1999 and 2001. The resultant defects had been filled with PMMA cement in 22 cases and bone graft in 2 cases. A review of all notes and radiographs was performed, with functional assessment of all available patients using the Musculoskeletal Tumour Society Scoring (MSTS).

Results: 24 consecutive cases were identified; 11 cases affecting the distal femur, 8 in the proximal humerus, 3 in the tibia and 1 each of the scapula and radius. Average age was 47 years, (range 22–75). Tumour grade was: grade 1 – 22 cases and grade 2 in 2 cases. Mean follow-up was 52 months, (range 38–73 months). There was a single case of local recurrence in a patient that had a grade 2 lesion; there were no incidences of metastases. Functional outcome was assessed in 20 of the 23 remaining cases, scoring a mean 93.7% (range 53–100) on the MSTS.

Conclusion: This study suggests intralesional curettage is an effective treatment strategy for extra-axial low grade chondrosarcoma with excellent oncological and functional results. Careful case selection, with stringent clinical and radiographic follow-up is recommended.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 228 - 228
1 May 2006
Whittingham-Jones P Molloy S Edge G Lehovsky J
Full Access

Background: There are conflicting reports regarding the effect of scoliosis surgery on respiratory function in Duchenne Muscular Dystrophy (DMD)1,2. Galasko et al2 found that the Percentage Predicted Forced Vital Capacity (%PFVC), remained static for thirty six months following surgery, in patients with DMD that underwent spinal stabilisation for scoliosis. The aim of the current study was to support or refute the above finding in a large series of patients with DMD.

Methods: A retrospective analysis of data on 55 consecutive patients with DMD that underwent single stage posterior surgical correction for scoliosis. We analysed the data of 55 boys with DMD who underwent scoliosis surgery between 1990 and 2002. Age at surgery, pre-operative Cobb angles, pre-operative %PFVC, and post-operative %PFVC at 6 months, 12-18 months and 2–3 years were collected. We documented the pre-operative Cobb angle ± SD to assess the difficulty level of our surgical cases. Percentage PFVC was used as our outcome measure to assess respiratory function. The mean pre-operative %PFVC was compared to the post –operative mean %PFVC at three different time intervals; at 6 months, 12 to 18 months and at 2 to 3 years.

Results: The mean age was 14.6 years (range 11.2–18yrs). The mean pre-operative Cobb angle was 65.4 degrees ± 14.8. The mean %PFVC pre-operatively was 33.9 ± 10.4. The mean post-operative %PFVC’s were: 6 months (29.1 ± 10.4), 12 to 18 months (27.6 ± 12.1) and 2 to 3 years (25.4 ± 8.7). Therefore the mean % PFVC following surgery at 6 months, 12 to 18 months and 2 to 3 years decreased from the mean pre-operative % PFVC by 4.8%, 6.3% and 8.5% respectively.

Conclusion: The natural history of patients with DMD is a gradual decline in respiratory function. In the current study the mean post –operative %PFVC was less than the mean pre-operative %PFVC at 6 months, 12 to 18 months and at 2 to 3 years post surgery. Our series would suggest that respiratory function declines post-operatively, even in the short term, in patients with DMD that undergo spinal stabilisation. The decline in respiratory function in our study was progressive over the 3 year follow up period.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 294 - 294
1 May 2006
Dunstan E Whittingham-Jones P Cannon S
Full Access

To reduce the disability after hip disarticulation customised endoprostheses have been used in our unit to preserve a proximal femoral above knee amputation stump. This procedure involves preservation of a musculocutaneous flap and insertion of a customised stump prosthesis that articulates with the acetabulum. This procedure has been performed not only for primary malignancy but also in the reconstructive setting. Six patients have undergone the above procedure with a good functional outcome-allowing mobilisation with an appropriate orthosis. We will discuss the complications of such a procedure that includes disassociation of the femoral head from the customised prosthesis.

We present the technique as a useful adjunct not only in the treatment of large proximal femoral tumours but also in the end stage reconstructive setting.