Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Full Access

We report the outcome of 320 primary Total Hip Arthroplasties (THA) with minimum 10-year follow-up (range 10–17 years, mean 12.6 years), performed by a single surgeon in Tauranga New Zealand, with the Exeter Contemporary Flanged all-polyethylene cup and Exeter femoral stem via a posterior approach. The aim of the study is to compare the results with the published results from the design centre and create a baseline cohort for further outcomes research in this centre.

All patients were prospectively followed at 6 weeks, 1 year, 5 years, 10 years, (and 15 years when available). Of 333 cases that matched the inclusion criteria, 13 procedures in 12 patents were excluded because of concomitant bone grafting and/or supplementary cage fixation, leaving 320 primary THA procedures in 280 patients, including 26 bilateral procedures in 13 patients.

Mean follow-up of the surviving cases was 12.6 (range 5.0-17.1) years. There were 12 revisions – 2 for fracture, 5 for instability, 1 for impingement pain and 4 for infection. There were no revisions for aseptic cup loosening. Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 100% at 15.0 years (with minimum 40 cases remaining at risk). All-cause acetabular revision in 12 cases result in a Kaplan-Meier survival of 95.9% (95% CI: 93.5 to 98.3%).

Cemented THA with the Exeter Contemporary Flanged cup and the Exeter stem is a durable combination with results that can be replicated outside of the design centre. The Exeter Contemporary Flanged cup has excellent survivorship at 15 years when used with the Exeter stem. Cemented THA with well-proven components should be considered the benchmark against which newer designs and materials should be compared.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 69 - 69
1 Sep 2012
McDougall CJ Gray HS Simpson PM Whitehouse SL Crawford R Donnelly W
Full Access

Bleeding related wound complications including deep infection, superficial infection and haematoma cause significant morbidity in lower limb joint arthroplasty surgery. It has been observed anecdotally that patients requiring therapeutic anti-coagulation within the peri-operative period have higher rates of bleeding related complications and those requiring intravenous heparin particularly appear to do poorly.

The aim of this study is to investigate the relationship between post-operative bleeding and wound complications in the patient requiring therapeutic warfarin, plus or minus heparin, in total hip arthroplasty surgery.

This is a retrospective cohort study reviewing 1047 primary total hip replacements performed in a single centre over a five year period and comparing outcomes of the patients on warfarin (89) with a double-matched control group of patients not on warfarin (179). Outcomes included rates of deep infection, excessive wound ooze or haematoma, superficial infection, return to OT for washout and need for revision operation. The study group was then sub analysed comparing those on IV heparin plus oral warfarin, to those on warfarin alone.

The warfarin group had significantly higher risk of deep joint infection (9% vs 2.2% p= 0.023), haematoma/wound ooze (28% vs 4% p < 0.001) and superficial infection (13.5% vs 2.2% p < 0.001) compared to the control group. In the sub analysis of the study group, those on IV heparin had significantly higher risk of haematoma/wound ooze (44% vs 28% p= 0.023) than those on warfarin alone.

The requirement of therapeutic anti-coagulation in the peri-operative period is a tenuous balance between the complications of thrombo-embolic disease and bleeding-related morbidity. In the past, perhaps the full burden of bleeding related complications has not been appreciated, but now improved understanding will enable the both the surgeon and the patient to make more informed decisions regarding therapeutic anticoagulation in elective arthroplasty surgery.