Bacterial biofilms play a key role in prosthetic infection (PI) pathogenesis. Establishment of the biofilm phenotype confers the bacteria with significant tolerance to systemic antibiotics and the host immune system meaning thorough debridement and prosthesis removal often remain the only possible course of treatment. Protection of the prosthesis and dead-space management may be achieved through the use of antibiotic loaded cements and beads to release high concentrations of antibiotics at the surgical site. The antibacterial and antibiofilm efficacy of these materials is poorly understood in the context of mixed species models, such as are often encountered clinically. A Aim
Methods
To evaluate the ability of different combinations of antibiotic loaded cement to inhibit bacteria growth and biofilm formation. Cement beads were aseptically prepared using Palacos R (plain 40g PMMA cement) or Palacos R+G (40g PMMA cement containing industrially added 0.5g of gentamicin), with or without supplementary antibiotics as follows: Palacos R; Palacos R+G; Palacos R The group 2 cement beads were initially eluted in broth at 37o C for 72hours then transferred to fresh broth containing a known concentration of bacteria. The group 1 samples were not eluted but directly immerse in culture broth containing bacteria. All samples were thereafter incubated at 37oC for 24 hours. After incubation, group 1 samples were visually assessed for bacterial growth, while for the group 2 samples, biofilm formation were quantified using ultrasonication and viable bacteria counting technique. Three proficient biofilm forming Aim
Method
Cement-in-cement femoral component revision is a useful and commonly practised technique. Onerous and hazardous re-shaping of the original cement mantle is required if the new stem does not seat easily. Furthermore, without removing the entirety of the original cement mantle, the freedom to alter anteversion or leg length is difficult to predict preoperatively. We present data from in vitro experiments testing the compatibility of the top cemented stems according to UK registry figures (NJR 2013). This data augments preoperative planning by indicating which revision stems require minimal or no cement reshaping when being inserted into another stem's mantle. We also present the maximum shortening and anteversion that can be achieved without reshaping the original cement mantle.
Prosthetic joint infection(PJI) still remains a concern in orthopaedic practice. Antibiotic-loaded acrylic-cement(ALAC) is a proven means of lowering the incidence of PJI. However, increasing antimicrobial resistance has complicated both prophylaxis and treatment, prompting the use of combination antimicrobial therapy, with the addition of vancomycin to gentamicin-containing ALAC commonly used. The new antimicrobial, daptomycin, has better activity than vancomycin and we studied its elution from ALAC in comparison with vancomycin, along with its impact on the co-elution of gentamicin. Cement beads were prepared from PalacosRG containing, 1g/2g daptomycin, 1g/2g vancomycin and without additional antibiotics. Six replicates of each combination were eluted in PBS at 37oC, at timed intervals, for up to 90days, the antibiotic loss was assessed using validated assays. The mean recovery of gentamicin after 90days was 1.1mg with half eluted within the first 6 hours. Recovery was significantly increased by 60% and 40% with addition of 1g&2g of daptomycin(two-tail t-test: p=0.004 and p=0.02), respectively. Although there was a slight increase in gentamicin recovery in vancomycin loaded samples, this was not statistically significant(p>0.05). The significant increases in gentamicin elution from Palacos RG when supplemented with daptomycin, along with a superior activity, may provide a better synergistic effect than PalacosRG supplemented with vancomycin in the management of PJI.
Unstable fractures of the distal tibia are being increasingly treated by open reduction and internal fixation using pre-contoured locking plates. Functional outcome following this type of fixation has not been reported previously. The aim of this study was to functionally assess patients following MIPO fixation of distal tibial fractures. Case notes of 26 patients treated at a single centre were reviewed. The fracture type, fixation technique, complications, time to union and subsequent treatment were documented. All patients returned for functional scoring using the validated American Academy of Orthopedic Surgeons (AAOS) foot and ankle core score. Twenty-six consecutive patients were treated between 2002-2005. The majority were male, and 5 were open fractures. There were 13 AO type A, 4 type B and 9 type C fractures. Mean follow up was 20 months. Average time from injury to surgery was 2.5 days. All fractures were treated by a MIPO technique. A pre-contoured distal locking plate was used for the distal tibial reconstruction. Secondary surgical procedures e.g. 2nd look, delayed primary closure, or skin grafting were necessary in 3 cases. The fibula was plated in 60% of cases. Four patients developed wound infections requiring antibiotics, and all resolved. The commonest rehabilitation regime was 6 weeks non weight bearing in plaster. Mean time to union was 18 weeks. There were 3 cases of delayed union, requiring bone grafting. One patient required removal of the plate due to local irritation, and one required a broken screw to be removed. Mean range of movement was 10 degrees dorsiflexion, 30 plantarflexion. The mean normalised AAOS foot and ankle core score was 41 (SD +/− 8). We conclude that MIPO fixation of distal tibial fractures is a safe and effective method of treatment. Functional outcome does not significantly differ from that of the general population.
High velocity vertical aircraft ejection seat systems are credited with aircrew survival of 80-95% in modern times. Use of these systems is associated with exposure of the aircrew to vertical acceleration forces in the order of 15-25G. The rate of application of these forces may be up to 250G per sceond. Up to 85% of crew ejecting suffer skeletal injury and vertebral fracture is relatively common (20-30%) when diagnosed by plain radiograph. The incidence of subtle spinal injury may not be as apparent. A prospective study to evaluate spinal injury following high velocity aircraft ejection.Background
Aim
We report a prospective case-series study to evaluate the results of non-operative and operative treatment of symptomatic unilateral lumbar spondylolysis. Non-operative treatment results in healing in most patients with symptomatic unilateral spondylolysis. Surgery however is indicated when symptoms persist beyond a reasonable time affecting the quality of life in young patients particularly the athletic population. We treated 41 patients [31 male, 10 female] with suspected unilateral lumbar spondylolysis. Thirty-one patients were actively involved in sports at various levels. Patients with a positive stress reaction on SPECT imaging underwent a strict protocol of activity restriction, bracing and physical therapy for 6 months. At the end of six months, patients who remained symptomatic underwent a Computed Tomography [CT] scan to confirm the persistence of a spondylolysis. Seven patients subsequently underwent a direct repair of the defect using the modified Buck's Technique. Baseline Oswestry disability index [ODI] and Short-Form-36 [SF-36] scores were compared to two year ODI and SF-36 scores for all patients. In the non-operated group, the mean pre-treatment ODI was 36 [SD=10.5], improving to 6.2 [SD=8.2] at two years. In SF-36 scores, the physical component of health [PCS] improved from 30.7 [SD=3.2] to 53.5 [SD =6.5] [p<0.001], and the mean score for the mental component of health [MCS] improved from 39 [SD=4.1] to56.5 [SD=3.9] [p<0.001] at two years. 20/31 patients resumed their sporting career within 6 months of onset of treatment, a further 4/31 patients returned to sports within one year. The seven patients who remained symptomatic at six months underwent a unilateral modified Buck's Repair. The most common level of repair was L5 (n=4). The mean pre-operative ODI was 39.4 (SD=3.6) improving to 4.4 (SD=4) at the latest follow-up. The mean score of PCS [SF-36] improved from 29.6 [SD=4.4] to 51.2 [SD=5.2] (SD=5.2) (p<0.001) and the mean score of MCS (SF-36) improved from 38.7 (SD=1.9) to 55.5 (SD=5.4) (p<0.001). A specific protocol of conservative treatment for patients with a unilateral lumbar spondylolysis resulted in a high rate of success with 83% of patients avoiding surgery. If symptoms persist beyond a reasonable period (i.e. 6 months) and reverse gantry CT scan confirms a non-healing defect of the pars interarticularis one may consider a unilateral direct repair of the defect with good outcome ultimately.
Our prospective observational study of patients treated for Thoracolumbar Adolescent Idiopathic Scoliosis (AIS) by anterior instrumentation aimed at investigating the correlation between the radiographic outcome and the recently-developed scoliosis research society self-reported outcomes instrument (SRS-22) which has been validated as a tool for self-assessment in scoliosis patients. Previous patient based questionnaires demonstrated poor correlation with the radiological parameters. Pre-operative, post-operative and two years follow-up radiographs of 30 patients were assessed. Thirteen radiographic parameters including Cobb angles and balance were recorded. The percentage improvements for each were noted. The SRS-22 questionnaire was completed by all patients at final follow-up. Correlation was sought between each radiographic parameter, total SRS score and each of the five domains by quantifying Pearson's Correlation Coefficient ( Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165), apical vertebra translation of the primary curve (r = -0.353), thoracic kyphosis (r = 0.043) and lumbar lordosis (r = 0.147) showed little or no correlation with the SRS-22 total score and its five individual domains. Significant inverse correlation was found between the upper instrumented vertebra angle and at follow-up and SRS-22 (r = -0.516). The same was true for Sagittal plumb line shift at final follow up (r = -0.447).Materials and Methods
Results